Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LCLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Investigation into the transport properties of planetary interiors through inelastic X-ray scattering experiments and quantum molecular dynamics (Final Technical Report)

This was a two-year research project for the period 08/15/2018 - 08/14/2020 conducted at the University of Nevada, Reno using Pronghorn, a newly built high-performance cluster located at the University. The short-term project goal was to provide computational support for the experimental campaigns at LCLS through data analysis of previous and upcoming scheduled experiments, along with performing state-of-the-art atomistic simulations of dense plasmas. The longer-term goal was to create a new computational high energy density physics group located at the University of Nevada, Reno. Guided by results from past and future high-resolution scattering experiments, we aimed to research and develop non-equilibrium and non-adiabatic atomistic simulations of dense plasmas that went beyond the Born-Oppenheimer approximation

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NNSA Light Source Enhancements: Coupling a High Energy Laser Driver to an XFEL

NNSA has an unmet capability gap to predict how changes in material microstructure, due to aging and new manufacturing practices, can affect performance at extremes. This capability gap is the basis for the Dynamic Mesoscale Material Science Capability (DMMSC) CD-0 that was signed in 2015 [1]. Because of the delay to the MaRIE facility approach, the Tri-Lab in March 2020 proposed separate complementary investments at the APS and LCLS to address portions of the DMMSC mission need [2].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging Wavepackets in Real-Space & Disentangling Ultrafast Solvation Dynamics with High-Energy Ultrafast X-ray Scattering

The microscopic information of solute and solute-solvent motions can be measured using ultrafast diffuse x-ray scattering, and compared to molecular dynamics simulations, as demonstrated in studies of solvated molecular systems done in X-ray free-electron lasers. However, for the typical photon energies used in these experiments, the photon momentum transfer range was limited to lower Q values where the signals arising from different parts of the studied system overlap significantly. Recently, this limitation was greatly alleviated by extending the photon energy at the Linac Coherent Light-Source (LCLS), significantly increasing the accessible momentum transfer range. This improvement is transformative for ultrafast diffuse x-ray scattering measurements, enabling for the first time to disentangle the solute scattering difference signal, that persists to higher Q values, from the bulk solvent and solute-solvent cross-terms difference signals. In addition, it enhances the prediction ability of modeling and simulation methods such as the hybrid QM/MM approach. The extended Q range also opens the way to resolve in real-space details regarding coherent wavepackets motions beyond their center-of-mass positions. Here, we present the first results on high-energy (18keV) diffuse x-ray scattering in solution, demonstrating high fidelity time-resolved scattering and analysis of the photoexcited model photocatalysts PtPOP ([Pt2(POP)4]4-), and IrDimen ([Ir2(dimen)4]2+) in several solvents. These complexes provide ideal systems for demonstrating the ability of high-Q ultrafast scattering and QM/MM simulations to decompose ultrafast solvation dynamics into specific changes in the solute-solvent pair distribution function with a particular focus on how electronically excited states change the interaction between the solvent and photo-catalytically active metal sites. We introduce an approach to further utilize the high-energy capability and demonstrate a single-shot ultra-wide-angle X-ray Scattering modality using two perpendicular detectors, spanning a scattering angle range of more than 100 degrees, allowing to extend the accessible momentum transfer range up to Q~14 Å-1. We develop a model-free method to invert the x-ray scattering signals and enable the recovery of multiple pair-density motions that happen simultaneously, allowing us to directly measure in real-space nuclear wavepacket motions. . [1] Natan, Adi. "Real-Space Inversion and Super-Resolution of Ultrafast X-ray Scattering using Natural Scattering Kernels." arXiv preprint arXiv:2107.05576 (2021)

Natan, Adi↗

Noncolinear Synthesis of Picosecond Flat-Top Laser Pulses to Increase Electron Photoinjector Brightness

Next-generation electron photoinjector accelerators, such as the LCLS-II photoinjector, have increasingly tight requirements on the excitation lasers, often calling for tens of picosecond, temporally flat-top, ultraviolet (UV) pulse trains to be delivered at up to 1 MHz[1]. We present a numerical and experimental implementation of a non-colinear sum frequency generation scheme wherein the incident optical pulses have equal and opposite amounts of spectral dispersion resulting in a spectrally narrowband pulse with flat-top temporal profile[2]. In preliminary experiments we achieve upwards of 40% conversion efficiency with this process. We additionally demonstrate the ability for the narrowband pulses to be directly upconverted to the UV for driving a photocathode.

Lemons, R.↗

Particulate Study on Materials for Cleanroom Assembly of SRF Cavities

Reducing particulates is an important aspect for cleanroom operation. Knowing that it is impossible to completely eliminate all particulates in a clean room, efforts have been made to prevent particulate from entering SRF cavities during high pressure rinsing (HPR) and assembly. At Jefferson Lab, one practice to achieve this goal has been clamping covers to cavity open flanges during assembly. Several cover materials that have been used are examined and alternative candidate materials are under development. Clamps as a known particulate generator are carefully examined and cleaning efficiency of different methods is studied. Assembly and cover tests were done on a dummy flange as well as real cavity flanges, which may help further understand the generation of particulate during assembly. Authored by Jefferson Science Associates, LLC under U.S. DOE Contracts DE-AC05-06OR23177 and DE-AC02-76SF00515 for the LCLS-II Project.

Zhao, Liang↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

aThe increase over the last years of the testing activities related to superconducting quantum materials, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4kL Dewar and two Mycom compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three regulatory valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing Supercritical Phase Transition using Ultrafast X-ray Diagnostics (Final Technical Report)

Over recent years, several hypotheses have been put forward to elucidate supercritical transition states. Despite significant progress on the fundamental understanding of fluids at these supercritical conditions, important questions concerning the microstructure and dynamical processes remain. A particular research issue is hereby the fundamental understanding of the morphology of the molecular microstructure and its effect on the macroscopic behaviour and thermodynamic response functions. It is widely believed that the supercritical state is homogeneous without structural and dynamic observables to distinguish between a liquid and a vapor. However, recent investigations have identified regions of distinct liquid-like or vapor-like properties even under supercritical conditions. Specifically, it was shown that the transition between liquid-like and vapor-like states occurs across an extension to the coexistence line, marked by almost discontinuous changes in fluid properties. This transition was first identified experimentally by Nishikawa and Tanaka and stands in contrast to the classical presentation of the supercritical state space as a featureless, homogeneous domain. Structurally, the most important properties of supercritical fluids are the dynamic heterogeneities and local density fluctuations that are present within the fluid state at the microscopic level. These inhomogeneities are associated with the formation of molecular clusters of various sizes with liquid-like properties separated by voids of unbound gas-phase molecules which continuously restructure itself at picosecond timescales. By utilizing ultrafast X-ray Photon Correlation Spectroscopy (XPCS) at the Linac Coherent Light Source (LCLS) and X-ray synchrotron measurements as an experimental probe of these structural changes at the molecular level we seek to elucidate the higher-order phase transition from a liquid-like to a vapor-like state in the region extending the critical point. Open questions we seek to address particularly with XPCS are: (i) the underlying mechanisms responsible for the density fluctuations at supercritical conditions and how these dynamical processes at the molecular level affect the thermodynamic response functions and (ii) on what timescales do dynamical processes evolve that are associated with thermalization, molecular diffusion, and intermolecular cluster transfer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of Materials at Extreme Pressure

The original proposal defined two classes of work: (1) shock dynamics in materials at the MEC endsta9on at LCLS x-ray laser at SLAC, and (2) study of the effect of shell structure and ioniza9on on the equa9on of state of carbon up to 1 Gbar at the NIF laser at LLNL. Support was requested for a graduate student and postdoc. This work, plus addi9onal science in related areas, was accomplished. The effort was funded 9/15/17 – 9/14/22 (through a no-cost extension).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the Interaction of Laser-Produced Proton Beams with Matter

A major goal of this project is to significantly increase our understanding of isochoric heating of matter using laser produced proton beams, and the associated high energy density (HED) and warm dense matter (WDM) regimes generated. This will benefit research fields such as planetary science, fusion energy, plasma physics, and material science. For example, it will enhance our understanding of WDM properties of iron and silica under conditions encountered in planetary interiors and diagnostic components in fusion devices exposed to high fluxes of energetic plasma ions. The project is motivated by recent experiments that irradiated Si targets with proton beams generated by the 20 TW-laser at the SLAC MEC end-station. The HED/WDM states are probed using the 50 fs hard X-rays available in the 3rd harmonic of the LCLS. As part of this project, results from the phase contrast X-ray imaging, which shows the generation of compression waves that produces rear surface spallation, are compared with results from the 3D multi-physics multi- material code, PISALE, that combines Arbitrary Lagrangian-Eulerian (ALE) hydrodynamics with Adaptive Mesh Refinement (AMR). This comparison required modifications to several physics models in the PISALE (Pacific Island Structured-AMR with ALE) code. An important aspect of this project is the continued training of graduate students in HED physics and in conducting complex multiphysics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pathway to tune sputter coated Nb$_3$Sn with Zr

Superconducting radio frequency (SRF) cavities are essential elements of many modern-day particle accelerators such as, European XFEL (DESY), LCLS II-HE (SLAC) and PIP II (Fermilab). Nb$_3$Sn superconducting material promises significant potential to exceed the performance of conventional niobium based SRF cavities. We aim to advance the ongoing R$&$D efforts to achieve Nb$_3$Sn coated cavities with high material quality. In this work, we have developed to achieve a route for effectively reducing the intrinsic defects in magnetron sputter coated Nb$_3$Sn SRF cavities and eventually improve the overall RF performance. We have observed that Zr is mainly being incorporated as ZrO$_2$ precipitates of average dimensions ranging from 20-100nm. By increasing the concentration of Zr, we have three major effects in the physical properties. Firstly, we noted that the density of the surface and bulk voids as well as their average dimensions are dramatically reduced on increasing the Zr content in Nb$_3$Sn. These surface voids are believed to be detrimental to cavity applications due to increase the local dissipation of electric and magnetic fields. These results indicate that inclusion of Zr in Nb$_3$Sn sputtered coating will improve the material quality and might help to reduce the overall RF power dissipation. Secondly, we observed that increasing Zr concentration from 0 to 2.4% substantially improves both superconducting transition temperature (Tc) and upper critical magnetic field (Hc2). However, on further increasing the Zr concentration to 24%, we noticed a small decrement in the Hc2 value. These results infer that the increase in Zr concentration up to an optimal concentration will be beneficial to enhance the superconducting properties. Increase in Tc promises lesser RF losses and improvement in accelerating gradient, whereas the increase in Hc2 suggests more efficient flux pinning which could give rise to high quality factors in presence of multi-Tesla magnetic field. Additionally, we also observed that increasing Zr concentration possibly prevents the oxygen diffusion and leads to thinner formation of primary surface oxide (Nb$_2$O$_5$ and SnO). This study gives a route to tune Zr fraction in Nb3Sn to modify the physical properties that control the high field performance of Nb3Sn RF cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experience of developing highly reliable Tuner components (piezo actuators and cold stepper motor actuators) for SRF Linac

The resonance control team at FNAL has led the design of the LCLS-II SRF Linac SRF cavity tuner subsystem. The Linac is expected to operate for over 30 years, and the longevity of the tuner is crucial to the overall reliability of the Linac. When the tuner's design was started, there were no active actuators (stepper and piezo) that could meet the longevity requirements of the Linac. The FNAL resonance control team, in collaboration with industrial partners (Phytron and PI), has developed actuators that have been shown to withstand a cryogenic and insulating vacuum environment for over 100 years in accelerated lifetime tests. Details of actuators design and longevity testing will be presented. Now, practically all (small and large) SRF systems that are under construction around the world are using actuators developed at FNAL. A review of possible actuators improvement will be presented.

Pischalnikov, Yuriy [Fermilab]↗

Cavity Preparation and Assembly: Challenges and Future R&D Directions

This presentation described the state of the art in cavity string assembly for the LCLS-II, HE, and PIP-II projects, as well as cavity performance statistics. The presentation also described the knowledge gap, opportunities for improvement, and future R&D recommendations.

Wu, Genfa [Fermilab]↗

Cavity Preparation and Assembly: Challenges and Future R&D Directions

This presentation described the state of the art in cavity string assembly for the LCLS-II, HE, and PIP-II projects, as well as cavity performance statistics. The presentation also described the knowledge gap, opportunities for improvement, and future R&D recommendations.

Wu, Genfa [Fermilab]↗

Girder Alignment Plan

The girders for the LCLS undulator system contain components which must be aligned with high accuracy relative to each other. The alignment is one of the last steps before the girders go into the tunnel, so the alignment must be done efficiently, on a tight schedule. This note documents the alignment plan which includes efficiency and high accuracy. The motivation for girder alignment involves the following considerations. Using beam based alignment, the girder position will be adjusted until the beam goes through the center of the quadrupole and beam finder wire. For the machine to work properly, the undulator axis must be on this line and the center of the undulator beam pipe must be on this line. The physics reasons for the undulator axis and undulator beam pipe axis to be centered on the beam are different, but the alignment tolerance for both are similar. In addition, the beam position monitor must be centered on the beam to preserve its calibration. Thus, the undulator, undulator beam pipe, quadrupole, beam finder wire, and beam position monitor axes must all be aligned to a common line. All relative alignments are equally important, not just, for example, between quadrupole and undulator. We begin by making the common axis the nominal beam axis in the girder coordinate system. All components will be initially aligned to this axis. A more accurate alignment will then position the components relative to each other, without incorporating the girder itself.

43 PARTICLE ACCELERATORS↗

Undulator Hall Air Temperature Fault Scenarios

Recent experience indicates that the LCLS undulator segments must not, at any time following tuning, be allowed to change temperature by more than about {+-}2.5 C or the magnetic center will irreversibly shift outside of acceptable tolerances. This vulnerability raises a concern that under fault conditions the ambient temperature in the Undulator Hall might go outside of the safe range and potentially could require removal and retuning of all the segments. In this note we estimate changes that can be expected in the Undulator Hall air temperature for three fault scenarios: (1) System-wide power failure; (2) Heating Ventilation and Air Conditioning (HVAC) system shutdown; and (3) HVAC system temperature regulation fault. We find that for either a system-wide power failure or an HVAC system shutdown (with the technical equipment left on), the short-term temperature changes of the air would be modest due to the ability of the walls and floor to act as a heat ballast. No action would be needed to protect the undulator system in the event of a system-wide power failure. Some action to adjust the heat balance, in the case of the HVAC power failure with the equipment left on, might be desirable but is not required. On the other hand, a temperature regulation failure of the HVAC system can quickly cause large excursions in air temperature and prompt action would be required to avoid damage to the undulator system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Undulator Transportation Test Results

A test was performed to determine whether transporting and handling the undulators makes any changes to their properties. This note documents the test. No significant changes to the test undulator were observed. After the LCLS undulators are tuned and fiducialized in the Magnetic Measurement Facility (MMF), they must be transported to storage buildings and transported to the tunnel. It has been established that the undulators are sensitive to temperature. We wish to know whether the undulators are also sensitive to the vibrations and shocks of transportation. To study this issue, we performed a test in which an undulator was measured in the MMF, transported to the tunnel, brought back to the MMF, and re-measured. This note documents the test and the results.

Wolf, Zachary↗

Triggering Klystrons

To determine if klystrons will perform to the specifications of the LCLS (Linac Coherent Light Source) project, a new digital trigger controller is needed for the Klystron/Microwave Department Test Laboratory. The controller needed to be programmed and Windows based user interface software needed to be written to interface with the device over a USB (Universal Serial Bus). Programming the device consisted of writing logic in VHDL (VHSIC (Very High Speed Integrated Circuits) hardware description language), and the Windows interface software was written in C++. Xilinx ISE (Integrated Software Environment) was used to compile the VHDL code and program the device, and Microsoft Visual Studio 2005 was used to compile the C++ based Windows software. The device was programmed in such a way as to easily allow read/write operations to it using a simple addressing model, and Windows software was developed to interface with the device over a USB connection. A method of setting configuration registers in the trigger device is absolutely necessary to the development of a new triggering system, and the method developed will fulfill this need adequately. More work is needed before the new trigger system is ready for use. The configuration registers in the device need to be fully integrated with the logic that will generate the RF signals, and this system will need to be tested extensively to determine if it meets the requirements for low noise trigger outputs.

Stefan, Kelton D.↗

Mechanical Design

The particle beam of the SXR (soft x-ray) beam line in the LCLS (Linac Coherent Light Source) has a high intensity in order to penetrate through samples at the atomic level. However, the intensity is so high that many experiments fail because of severe damage. To correct this issue, attenuators are put into the beam line to reduce this intensity to a level suitable for experimentation. Attenuation is defined as 'the gradual loss in intensity of any flux through a medium' by [1]. It is found that Beryllium and Boron Carbide can survive the intensity of the beam. At very thin films, both of these materials work very well as filters for reducing the beam intensity. Using a total of 12 filters, the first 9 being made of Beryllium and the rest made of Boron Carbide, the beam's energy range of photons can be attenuated between 800 eV and 9000 eV. The design of the filters allows attenuation for different beam intensities so that experiments can obtain different intensities from the beam if desired. The step of attenuation varies, but is relative to the thickness of the filter as a power function of 2. A relationship for this is f(n) = x{sub 0}2{sup n} where n is the step of attenuation desired and x{sub 0} is the initial thickness of the material. To allow for this desired variation, a mechanism must be designed within the test chamber. This is visualized using a 3D computer aided design modeling tool known as Solid Edge.

Shook, Richard↗