Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

ILC Polarized Electron Source Design and R&D Program

The R and D program for the ILC electron focuses on three areas. These are the source drive laser system, the electron gun and photo cathodes necessary to produce a highly polarized electron beam. Currently, the laser system and photo cathode development take place at SLAC's 'ILC Injector Test facility', which is an integrated lab (laser and gun) that allows the production of the electron beam and is equipped with a set of diagnostics, necessary to characterize the source performance. Development of the ILC electron gun takes place at Jefferson Lab, where advanced concepts and technologies for HV DC electron guns for polarized beams are being developed. The goal is to combine both efforts at one facility to demonstrate an electron beam with ILC specifications, which are electron beam charge and polarization as well as the cathode's lifetime. The source parameters are summarized in Table 1. The current schematic design of the ILC central complex is depicted in Figure 1. The electron and positron sources are located and laid out approximately symmetric on either side of the damping rings.

43 PARTICLE ACCELERATORS↗

Baryon Spectroscopy and Resonances

A short review of current efforts to determine the highly excited state spectrum of QCD, and in particular baryons, using lattice QCD techniques is presented. The determination of the highly excited spectrum of QCD is a major theoretical and experimental challenge. The experimental investigation of the excited baryon spectrum has been a long-standing element of the hadronic-physics program, an important component of which is the search for so-called 'missing resonances', baryonic states predicted by the quark model based on three constituent quarks but which have not yet been observed experimentally. Should such states not be found, it may indicate that the baryon spectrum can be modeled with fewer effective degrees of freedom, such as in quark-diquark models. In the past decade, there has been an extensive program to collect data on electromagnetic production of one and two mesons at Jefferson Lab, MIT-Bates, LEGS, MAMI, ELSA, and GRAAL. To analyze these data, and thereby refine our knowledge of the baryon spectrum, a variety of physics analysis models have been developed at Bonn, George Washington University, Jefferson Laboratory and Mainz. To provide a theoretical determination and interpretation of the spectrum, ab initio computations within lattice QCD have been used. Historically, the calculation of the masses of the lowest-lying states, for both baryons and mesons, has been a benchmark calculation of this discretized, finite-volume computational approach, where the aim is well-understood control over the various systematic errors that enter into a calculation; for a recent review. However, there is now increasing effort aimed at calculating the excited states of the theory, with several groups presenting investigations of the low-lying excited baryon spectrum, using a variety of discretizations, numbers of quark flavors, interpolating operators, and fitting methodologies. Some aspects of these calculations remain unresolved and are the subject of intense effort, notably the ordering of the Roper resonance in the low-lying Nucleon spectrum.

43 PARTICLE ACCELERATORS↗

Development of Bayesian analysis program for extraction of polarisation observables at CLAS

At the mass scale of a proton, the strong force is not well understood. Various quark models exist, but it is important to determine which quark model(s) are most accurate. Experimentally, finding resonances predicted by some models and not others would give valuable insight into this fundamental interaction. Several labs around the world use photoproduction experiments to find these missing resonances. The aim of this work is to develop a robust Bayesian data analysis program for extracting polarisation observables from pseudoscalar meson photoproduction experiments using CLAS at Jefferson Lab. This method, known as nested sampling, has been compared to traditional methods and has incorporated data parallelisation and GPU programming. It involves an event-by-event likelihood function, which has no associated loss of information from histogram binning, and results can be easily constrained to the physical region. One of the most important advantages of the nested sampling approach is that data from different experiments can be combined and analysed simultaneously. Results on both simulated and previously analysed experimental data for the K{sup +}Λ channel will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the (e,e') cross section for12C, 48Ti, 27Al and 40Ar

Many experiments have found that neutrinos have three different flavors, and they can transform from each other. Each flavor is a mixture of three nonzero mass states. In neutrino oscillation experiments, the uncertainty of the extracted oscillation parameters is dependent on the neutrino-nucleus cross section. In recent years various experiments provided precise neutrino and anti-neutrino cross section measurements and they have shown the inability of current Monte Carlo simulations to reproduce the data. A more accurate nuclear structure model of the target employed in neutrino detector is urgently needed to improve the precision of long baseline neutrino experiments. Electron scattering has been one of the most powerful methods of obtaining information about cross sections in the past. In the upcoming deep underground neutrino experiment (DUNE), Liquid Argon Time Projection Chambers (LArTPCs) will be used as the detector technology and argon will be used as the nuclear target. There are very few data available on argon and there is not an accurate nuclear model that describes them accurately, at ~5% level. We have performed an electron-argon scattering experiment at Jefferson Lab (E12-14-012) to provide accurate data that will help build a reliable nuclear model for describing neutrino-argon scattering. The JLab E12-14-012 experiment has successfully taken data in Hall A at the Thomas Jefferson National Accelerator Facility between February and March of 2017. We collected data for the inclusive (e,e') and exclusive (e,e'p) processes for a variety of targets (argon, titanium, aluminum, carbon) at a wide range of kinematic settings. This thesis will present the results of the inclusive double differential cross sections for carbon, titanium, aluminum and argon at beam energy E = 2:222 GeV and scattering angle theta = 15:541 deg with total uncertainties smaller than 5%. The kinematic settings covered a broad range of energy transfers, including deep inelastic scattering (DIS), delta production, and quasielastic scattering.

Dai, Hongxia↗

A new cw-NMR Q-meter for dynamically polarized targets for particle physics

Polarized solid targets produced via Dynamic Nuclear Polarization rely on Continuous-Wave Nuclear Magnetism Resonance measurements to accurately determine the degree of polarization of bulk samples polarized to nearly 100%. Since the late 1970's phase sensitive detection methods have been utilized to observe the magnetization of a sample as a small change in inductance under RF excitation near the Larmor frequency of the nuclear species of interest, using a device known as a Q-meter. Liverpool Q-meters, produced in the UK in the 80's and 90's, have been the workhorse devices for these targets for decades, however their age and scarcity has meant new systems are needed. In conclusion, we describe a Q-meter system designed and built at Jefferson Lab in the Liverpool style to have comparable electronic performance with several improvements to update and adapt the devices for modern use.

Dynamic nuclear polarization↗

Microstructure and 77K mechanical properties of electron beam welded Cu101- Inconel 625 joints

In developing large-scale next-generation superconducting radio frequency (SRF) linear accelerators using superconducting films on Cu, the design and development of dissimilar welding and joining metals, such as Cu to Inconel, stainless steel, and Nb, are essential. In this talk, we present the development of procedures for electron-beam welding of Cu¿Inconel 625 and evaluation of the microstructure and 77K mechanical properties of the weld and base material in the welded condition and heat treatments in the 750°C ¿950°C heat treatment range. The results will be presented in the context of developing joining techniques for low-temperature applications where high conductivity and strength, vacuum hygiene, and magnetic properties of the material need consideration. The methods presented here are being deployed to thin film SRF Cu cavities at Jefferson Lab. Acknowledgment: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear

Khanal, Bashu↗

Measurement of the Elastic Ep Cross Section at Q2 = 0.66, 1.10, 1.51 and 1.65 Gev2

The nucleon form factors have been investigated by physicists for decades because of their fundamental importance. The world data of the proton magnetic form factor GMp has been focused on Q2 lower than 5 GeV2 and they have large uncertainties at higher Q2. Jefferson Lab experiment E12-07-108 aims to improve the accuracy of the e ? p elastic cross section to better than 2% over a Q2 range of 7 ? 14 GeV2. From 2015 to 2016, the e ? p elastic cross section was measured over a wide range of Q2 from 0.66 ? 12.56 GeV2 at the Thomas Jefferson National Accelerator Facility in Virginia, USA. An unpolarized electron beam was scattered o? a cryogenic hydrogen target and the scattered electron was detected in the high resolution spectrometers. This thesis focuses on the cross section calculations of the data taken in the spring of 2015, where Q2 = 0.66, 1.10, 1.51 and 1.66 GeV2. At Q2 = 0.66 GeV2, an uncertainty < 3% was achieved and < 5% was achieved for the other three Q2 at the moment. The results were compared with the world data and the good agreement provides confidence for the experimental measurements at higher Q2.

Wang, Yang↗

Compact and Handheld Radioisotope Imaging Systems for Bio-medicine*

Author: Andrew Weisenberger (Thomas Jefferson National Accelerator Facility) Thomas Jefferson National Accelerator Facility is a U.S. Department of Energy federally funded research and development center whose mission is to study quark gluon physics. The laboratory capitalizes on its unique technologies and expertise to explore ways of applying nuclear physics principles and technologies to societal needs. The Radiation Detector and Imaging Group, in collaboration with universities, industry and other government laboratories, has for several years been applying advances in nuclear physics detector technology to several applications, particularly in the development of compact and handheld nuclear imaging systems. I will provide a brief overview of Jefferson Lab and provide examples of how the group has leveraged nuclear physics to bring advances to nuclear medicine, medical research and plant biology. The group continues to develop medical devices based on both single photon emission computed tomography (SPECT) and positron emission tomography (PET), making use of technology originally developed for basic nuclear physics research. *Thomas Jefferson National Accelerator Facility is operated by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177.

Weisenberger, Andrew↗

Performance of Oak Ridge National Laboratory spallation neutron source proton power upgrade cavities and cryomodule production

The Proton Power Upgrade initiative at Oak Ridge National Lab’s Spallation Neutron Source aims to greatly boost the capability of proton beam power. This upgrade involves the integration of seven additional cryomodules, each housing four six-cell high-beta ( β = 0.81 ) superconducting radio frequency cavities. These cavities, manufactured and processed by Research Instruments in Germany, underwent meticulous treatment, including electropolishing as the bulk and final vital step. Upon delivery to Jefferson Lab, a total of 28 cavities for seven cryomodules, along with an additional four cavities for a spare cryomodule, underwent thorough vertical qualification tests, meeting the required specifications. Following cavity tanking and subsequent rf testing, the assembly of eight cryomodules was successfully executed, with all 32 cavities demonstrating compliance with acceptance criteria. The transportation of the cryomodule to SNS for high-power testing in the tunnel yielded exceptional results. Notably, the performance surpassed specifications, in terms of quality factor and accelerating gradient. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

A Compton transmission polarimeter for DC and SRF electron photo-injectors

The production of high-current and intense spin polarized electron beams is of great importance in electron-based facilities. Tests are planned to produce such beams in 2023 using GaAs-based photocathodes installed in the Brookhaven National Lab RHIC Coherent electron Cooling superconducting radiofrequency (SRF) photogun [1]. A fast and efficient electron polarimeter operating in the MeV energy range is required to measure the beam spin polarization. While Mott polarimeters provide larger measured asymmetries, a Compton Transmission polarimeter is well suited in the few MeV energy range. In this work, we report on a relatively compact and cost-effective Compton transmission polarimeter which has been built and calibrated at Jefferson Lab (JLab). First, we present the design of the polarimeter radiator, polarized target analyzing magnet, BGO detector assembly and data acquisition system. Next, results of a two-week commissioning study performed at the JLab Upgraded Injector Test Facility will be described. Here, a well-known polarized electron beam produced from a bulk GaAs photocathode in a dc high-voltage photogun was first measured in a 180 keV Mott scattering polarimeter, then used to characterize and calibrate the Compton transmission polarimeter as a function of the polarized target magnetization and beam properties. Finally, we report an effective analyzing power of the Compton polarimeter and compare experimental results with those produced via Geant4 simulations.

Blume, G.↗

The CLAS12 Torus Detector Magnet at Jefferson Laboratory

The CLAS12 Torus is a toroidal superconducting magnet, which is part of the detector for the 12-GeV accelerator upgrade at Jefferson Laboratory (JLab). The coils were wound/fabricated by Fermilab, with JLab responsible for all other parts of the project scope, including design, integration, cryostating the individual coils, installation, cryogenics, I&C, etc. This paper provides an overview of the CLAS12 Torus magnet features and serves as a status report of its installation in the experimental hall. Completion and commissioning of the magnet is expected in 2016.

43 PARTICLE ACCELERATORS↗

Particulate Study on Materials for Cleanroom Assembly of SRF Cavities

Reducing particulates is an important aspect for cleanroom operation. Knowing that it is impossible to completely eliminate all particulates in a clean room, efforts have been made to prevent particulate from entering SRF cavities during high pressure rinsing (HPR) and assembly. At Jefferson Lab, one practice to achieve this goal has been clamping covers to cavity open flanges during assembly. Several cover materials that have been used are examined and alternative candidate materials are under development. Clamps as a known particulate generator are carefully examined and cleaning efficiency of different methods is studied. Assembly and cover tests were done on a dummy flange as well as real cavity flanges, which may help further understand the generation of particulate during assembly. Authored by Jefferson Science Associates, LLC under U.S. DOE Contracts DE-AC05-06OR23177 and DE-AC02-76SF00515 for the LCLS-II Project.

Zhao, Liang↗

Particulate Study on Materials for Cleanroom Assembly of SRF Cavities

Reducing particulates is an important aspect for cleanroom operation. Knowing that it is impossible to completely eliminate all particulates in a clean room, efforts have been made to prevent particulate from entering SRF cavities during high pressure rinsing (HPR) and assembly. At Jefferson Lab, one practice to achieve this goal has been clamping covers to cavity open flanges during assembly. Several cover materials that have been used are examined and alternative candidate materials are under development. Clamps as a known particulate generator are carefully examined and cleaning efficiency of different methods is studied. Assembly and cover tests were done on a dummy flange as well as real cavity flanges, which may help further understand the generation of particulate during assembly. Authored by Jefferson Science Associates, LLC under U.S. DOE Contracts DE-AC05-06OR23177 and DE-AC02-76SF00515 for the LCLS-II Project.

Zhao, Liang↗

Longitudinal spin transfer to Λ hyperons in semi-inclusive deep inelastic scattering with the CLAS12 spectrometer

The polarization of Λ hyperons is preserved in the angular distribution of their decay products. This property allows one to study the spin structure of the Λ. In semi-inclusive deep inelastic scattering where a high energy lepton interacts with a nucleon target and one or more hadrons and the scattered lepton are detected in the final state, the probability for a struck quark to impart the polarization of the lepton to the Λ may be measured. In particular, in electron-proton scattering this quantity may be related to the longitudinal light quark polarization of the Λ. Currently, limited experimental data cannot discriminate between different models of Λ spin structure. This work reports on the measurement of the longitudinal spin transfer 𝐷$^{Λ}_{𝐿⁢𝐿′}$ to the Λ using data taken by the CLAS12 spectrometer at Jefferson Lab with a 10.6 GeV longitudinally polarized electron beam and an unpolarized hydrogen target. This measurement is the most precise to date, and, in comparison with theory predictions, it offers valuable insight into the relative dominance of current and target fragmentation in Λ production.

deep inelastic scattering↗

Neutron Skin Measurement of208Pb Using Parity-Violating Electron Scattering

Nuclear stability requires large nuclei to have more neutrons than protons. While the central core of the nucleus is composed of symmetric nuclear matter, the extra neutrons in heavy nuclei are pushed out to the surface of the nucleus, forming a pure outer neutron skin layer. While the proton distribution inside a nucleus has been accurately measured using electromagnetic probes, previous measurements of neutron distributions in complex nuclei have suffered a lack of systematic precision. PREX-2 and CREX use Parity-Violating electron Scattering (PVeS), as an electroweak interaction probe, to measure the neutron distributions in208Pb and48Ca, respectively. Making use of elastic scattering of longitudinally polarized electrons from unpolarized (isotopically pure) targets, PREX-2 and CREX measure the asymmetry in scattering rates between opposite beam polarization states. Since both experiments share the same exact measurement concept and apparatus, much of this dissertation applies to both PREX-2 and CREX. However, the presented asymmetry analysis and neutron skin extraction are only for PREX-2. PREX-2 measures the parity-violating asymmetry, APV, for 953 MeV electrons scattered elastically from208Pb at?5°in the lab. The final result is APV= 550.00±16.09(stat.)±8.16(syst.)ppb. From this measurement, we report the neutron skin thickness in208Pb nuclei to be, Rskin= 0.278±0.078(exp.)±0.012(model) fm. This measurement has broad implications throughout the physics community, increasing our knowledge in neutron star structure, the equation of state of nuclear matter, nuclear baryon density, nuclear electric dipole polarizability, and more. Key Words: Neutron skin, electroweak interaction, PREX-2, CREX, parity-violating asymmetry, neutron star, quartz detector, weak charge radius, symmetry energy, Hall A, Jefferson Lab

Adhikari, Devi↗

Hydra: computer vision for data quality monitoring

Hydra, initially developed for Hall-D in 2019, is a system that utilizes computer vision to perform near real time data quality monitoring. Since then, it has been deployed across all experimental halls at Jefferson Lab, with the CLAS12 collaboration in Hall-B being the first outside of GlueX to fully utilize Hydra. The system comprises back end processes that manage the models, their inferences, and the data flow. Finally, the front-end components, accessible via web pages, allow detector experts and shift crews to view and interact with the system.

47 OTHER INSTRUMENTATION↗

The Roper Resonance and Kin

The properties of the Roper resonance N(1440) 1/ 2 + are reviewed. Quark models have long struggled to reproduce its mass relative to its negative parity partner N(1535) 1/ 2 − . This discrepancy motivated interpretations of the Roper as a dynamically generated meson–baryon state. Including its isospin partners ∆(1600) 3/ 2 + and ∆(1700) 3/ 2 − further accentuates the tension between quark-model predictions and experiment. Recent develop ments based on AdS/QCD and functional methods achieve much improved agreement, identifying the Roper as an ordinary three-quark excitation. Electroproduction experiments at Jefferson Lab have now resolved this long-standing question, revealing the Roper as a qqq core dressed by a substantial meson cloud. The Roper resonance belongs to a family of four N ∗ states with J P = 1/ 2 + ; the highest-mass member, N(2100) 1/ 2 + , likely represents a Roper-like excitation in the fourth shell.

Burkert, Volker [Thomas Jefferson National Acceler↗