Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Isotope Program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

High Radiation Environment Nuclear Fragment Separator Magnet (Final Report)

Dipole magnets with a field of 2 T are needed for the 30° bend in the Facility for Rare Isotope Beams (FRIB) fragment separator. This magnet will be subjected to extremely high radiation and heat loads from the high radiation. Superconducting coils for this magnet would allow low power operation but traditional NbTi and Nb3Sn superconductors are sensitive to quenches from beam loss and must operate near 4.5 K where the removal of thermal heat generated by beam loss is inefficient due to basic Carnot principles. High Temperature Superconductor (HTS) offers a unique solution for the magnets in the high radiation environment expected at FRIB. These conductors can operate at 40 K where heat removal is an order of magnitude more efficient than at 4.5 K. The curved separator dipoles subtend a large angular bend which introduces some complications in the winding of the coils. One approach would be to wind the coils with a curved section on the inner and outer radial segments (banana shaped). The inner radial segment would be wound with a negative curvature that would tend to unwind. An alternate approach would be to use a straight segment on the inner segment to avoid the negative curvature (D-shaped). In Phase I coils with a limited number of turns were successfully wound for both configurations described. These coils were tested at 77 K in liquid nitrogen. The Phase II program concentrated on the design, structural analysis, prototyping and test of the HTS curved dipole coils required for the high radiation environment of the FRIB fragment separator region. A thermal analysis was performed to simulate that the heat load can be removed. A test coil containing 500 m of HTS conductor was constructed to be tested at the 40 K operating temperature. The anticipated heat load was simulated with heater strips to demonstrate that the heat can be removed and that the coil can operate in a stable state.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Uranium Measurements in Water by Various Methods - 13571

In December 2000, EPA amended its drinking water regulations for radionuclides by adding a Maximum Contaminant Level (MCL) for uranium (so called MCL Rule)[1] of 30 micrograms per liter (μg/L). The MCL Rule also included MCL goals of zero for uranium and other radionuclides. Many radioactively contaminated sites must test uranium in wastewater and groundwater to comply with the MCL rule as well as local publicly owned treatment works discharge limitations. This paper addresses the relative sensitivity, accuracy, precision, cost and comparability of two EPA-approved methods for detection of total uranium: inductively plasma/mass spectrometry (ICP-MS) and alpha spectrometry. Both methods are capable of measuring the individual uranium isotopes U-234, U- 235, and U-238 and both methods have been deemed acceptable by EPA. However, the U-238 is by far the primary contributor to the mass-based ICP-MS measurement, especially for naturally-occurring uranium, which contains 99.2745% U-238. An evaluation shall be performed relative to the regulatory requirement promulgated by EPA in December 2000. Data will be garnered from various client sample results measured by ALS Laboratory in Fort Collins, CO. Data shall include method detection limits (MDL), minimum detectable activities (MDA), means and trends in laboratory control sample results, performance evaluation data for all methods, and replicate results. In addition, a comparison will be made of sample analyses results obtained from both alpha spectrometry and the screening method Kinetic Phosphorescence Analysis (KPA) performed at the U.S. Army Corps of Engineers (USACE) FUSRAP Maywood Laboratory (UFML). Many uranium measurements occur in laboratories that only perform radiological analysis. This work is important because it shows that uranium can be measured in radiological as well as stable chemistry laboratories and it provides several criteria as a basis for comparison of two uranium test methods. This data will indicate which test method is the most accurate and most cost effective. This paper provides a benefit to Formerly Utilized Sites Remedial Action Program (FUSRAP) and other Department of Defense (DOD) programs that may be performing uranium measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality assurance for the clinical implementation of kilovoltage intrafraction monitoring for prostate cancer VMAT

Purpose: Kilovoltage intrafraction monitoring (KIM) is a real-time 3D tumor monitoring system for cancer radiotherapy. KIM uses the commonly available gantry-mounted x-ray imager as input, making this method potentially more widely available than dedicated real-time 3D tumor monitoring systems. KIM is being piloted in a clinical trial for prostate cancer patients treated with VMAT (NCT01742403). The purpose of this work was to develop clinical process and quality assurance (QA) practices for the clinical implementation of KIM. Methods: Informed by and adapting existing guideline documents from other real-time monitoring systems, KIM-specific QA practices were developed. The following five KIM-specific QA tests were included: (1) static localization accuracy, (2) dynamic localization accuracy, (3) treatment interruption accuracy, (4) latency measurement, and (5) clinical conditions accuracy. Tests (1)–(4) were performed using KIM to measure static and representative patient-derived prostate motion trajectories using a 3D programmable motion stage supporting an anthropomorphic phantom with implanted gold markers to represent the clinical treatment scenario. The threshold for system tolerable latency is <1 s. The tolerances for all other tests are that both the mean and standard deviation of the difference between the programmed trajectory and the measured data are <1 mm. The (5) clinical conditions accuracy test compared the KIM measured positions with those measured by kV/megavoltage (MV) triangulation from five treatment fractions acquired in a previous pilot study. Results: For the (1) static localization, (2) dynamic localization, and (3) treatment interruption accuracy tests, the mean and standard deviation of the difference are <1.0 mm. (4) The measured latency is 350 ms. (5) For the tests with previously acquired patient data, the mean and standard deviation of the difference between KIM and kV/MV triangulation are <1.0 mm. Conclusions: Clinical process and QA practices for the safe clinical implementation of KIM, a novel real-time monitoring system using commonly available equipment, have been developed and implemented for prostate cancer VMAT.

07 ISOTOPE AND RADIATION SOURCES↗

TH-CD-201-10: Highly Efficient Synchronized High-Speed Scintillation Camera System for Measuring Proton Range, SOBP and Dose Distributions in a 2D-Plane

Purpose: Proton therapy (PT) delivery is complex and extremely dynamic. Therefore, quality assurance testing is vital, but highly time-consuming. We have developed a High-Speed Scintillation-Camera-System (HS-SCS) for simultaneously measuring multiple beam characteristics. Methods: High-speed camera was placed in a light-tight housing and dual-layer neutron shield. HS-SCS is synchronized with a synchrocyclotron to capture individual proton-beam-pulses (PBPs) at ∼504 frames/sec. The PBPs from synchrocyclotron trigger the HS-SCS to open its shutter for programmed exposure-time. Light emissions within 30×30×5cm3 plastic-scintillator (BC-408) were captured by a CCD-camera as individual images revealing dose-deposition in a 2D-plane with a resolution of 0.7mm for range and SOBP measurements and 1.67mm for profiles. The CCD response as well as signal to noise ratio (SNR) was characterized for varying exposure times, gains for different light intensities using a TV-Optoliner system. Software tools were developed to analyze ∼5000 images to extract different beam parameters. Quenching correction-factors were established by comparing scintillation Bragg-Peaks with water scanned ionization-chamber measurements. Quenching corrected Bragg-peaks were integrated to ascertain proton-beam range (PBR), width of Spared-Out-Bragg-Peak (MOD) and distal.

07 ISOTOPE AND RADIATION SOURCES↗

Production of Medically Important Radionuclides 52 Mn and 90 Nb

Over the final reporting period of this project, we at MGH finalized our effort on Project 2: Production and Characterization of 90 Nb which, as per our previous report led us to an interesting application of mass spectrometry in radiometal chemistry. Overall, our research has developed parameters and procedures for delivering high 90 Nb for preclinical and translational applications by initializing the cyclotron targetry and separation chemistry for delivering 90 Nb in a chemical form suitable for subsequent development of 90 Nb-based PET radiotracers, and most recently we have published on the mass spectrometry applications described in the present report. We have been working with MSKCC (PI Jason Lewis) on the 90 Nb methodology and have had input from UAB (PI Suzy Lapi). An in-person meeting was held during the upcoming funding period with 2 PIs who are co-organizing the Radiochemistry Symposium (Lapi and Vasdev) and Program Director Dr. Ethan Balkin, during the ACS National Meeting in March 2018, and 2 PIs (Lewis and Vasdev) co presented in at the World Federation of Nuclear Medicine and Biology at a symposium sponsored by the Australian Nuclear Sciences and Technology Organisation, where they are both collaborating, in Melbourne, Australia in April 2018. Future projects and collaborations are under discussion with the Lapi lab to focus on new applications of 76 Br chemistry, and a new collaboration has already resulted with the Lewis lab on 18 F radiochemistry that employ iodonium ylide based precursors developed in the Vasdev lab, for clinical production of [ 18 F]MFBG. It is noteworthy that the PI has now relocated to the University of Toronto and has 2 cyclotrons (IBA Cyclone and Scanditronix MC-17) that will also be used to explore new 11 C-radiochemistry including [ 11 C]CO.

07 ISOTOPE AND RADIATION SOURCES↗

Hauser-Feshbach Analysis of Fast Neutron-Induced Reactions on Chlorine

Neutron-induced reactions on 35Cl have recently been measured and analyzed in a Hauser-Feshbach framework at Los Alamos National Laboratory. Particular focus has been applied to the “fast” energy range above 100 keV, where these reactions become important for applications like CLYC (Cs 2 LiYCl 6 :Ce) detector characterization and the development of molten chloride fast reactors. However, challenges to applying a purely statistical analysis to this mass range have presented themselves in the form of cross section fluctuations and deviations due to low-mass structure. In this paper, these challenges and their current solutions will be highlighted, as well as preliminary extensions of the analysis to neighboring isotopes and future plans to extend the measurements down to thermal energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Invited Article: SUBGLACIOR: An optical analyzer embedded in an Antarctic ice probe for exploring the past climate

This article describes the advances made in the development of a specific optical spectrometer based on the Optical Feedback-Cavity Enhanced Absorption Spectroscopy technique for exploring past climate by probing the original composition of the atmosphere stored in the ice sheet of a glacier. Based on significant technological progresses and unconventional approaches, SUBGLACIOR will be a revolutionary tool for ice-core research: the optical spectrometer, directly embedded in the drilling probe, will provide in situ real-time measurements of deuterium isotopic variations (δ{sup 2}H ) and CH{sub 4} concentrations down to 3500 m of ice depth within a single Antarctic season. The instrument will provide simultaneous and real-time vertical profiles of these two key climate signatures in order to evaluate if a target site can offer ice cores as old as 1.5 million years by providing direct insight into past temperatures and climate cycles. The spectrometer has a noise equivalent absorption coefficient of 2.8 × 10{sup −10} cm{sup −1} Hz{sup −1/2}, corresponding to a detection limit of 0.2 ppbv for CH{sub 4} and a precision of 0.2‰ on the δ{sup 2}H of H{sub 2}O within 1 min acquisition time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Testing for a New Thermosyphon Irradiation Vehicle

The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL) requires most materials and all fuel experiments to be placed in a pressure containment vessel to ensure that internal contaminants such as fission products cannot be released into the primary coolant. It also requires that all experiments be capable of withstanding various accident conditions (e.g., loss of coolant) without generating vapor bubbles on the surface of the experiment in the primary coolant. These requirements are intended to artificially increase experiment temperatures by introducing a barrier between the experimental materials and the HFIR coolant, and by reducing heat loads to the HFIR primary coolant, thus ensuring that no boiling can occur. A proposed design for materials irradiation would remove these limitations by providing the required primary containment with an internal cooling flow. This would allow for experiments to be irradiated without concern for coolant contamination (e.g., from cladding failure of advanced fuel pins) or for specimen heat load. This report describes a new materials irradiation experiment design that uses a thermosyphon cooling system to allow experimental materials direct access to a liquid coolant. The new design also increases the range of conditions that can be tested in HFIR. This design will provide a unique capability to validate the performance of current and advanced fuels and materials. Because of limited supporting data for this kind of irradiation vehicle, a test program was initiated to obtain operating data that can be used to (1) qualify the vehicle for operation in HFIR and (2) validate computer models used to perform design- and safety-basis calculations. This report also describes the test facility and experimental data, and it provides a comparison of the experimental data to computer simulations. A total of 51 tests have been completed: four tests with pure steam, 12 tests with argon, and 35 tests with helium. A total of 10 tests were performed at subatmospheric pressure, and four of these were performed with pure steam. One test was conducted at a high power of 92.7 kW, six tests were HFIR startups, and two tests were HFIR loss of offsite power (LOOP). Pressures up to 10 MPa, vapor temperatures up to 583 K (310°C), and heater temperatures above 600 K (327°C) have been reached in these tests. Two computer programs, RELAP5-3D and TRACE, have been used to simulate the tests. The TRACE code has shown good agreement with the test data and has been used to model a variety of tests. This experimental facility has been very useful in demonstrating the viability of this new type of irradiation facility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Criticality Scoping Calculations for a Multi-Function Dissolver Insert

As one of its missions, the Savannah River Site seeks to be a leader in the safe and productive disposition of special nuclear materials. One of the premier programs is the disposition of used nuclear fuel, primarily from research reactors, through dissolution, purification, and down blend into low enriched uranium for commercial power reactors. Prior to use, this fuel contained highly enriched uranium (HEU). In an effort to advance this expertise, this study has been performed to demonstrate the feasibility to disposition a number of special geometry HEU fuels. These fuels come from a number of different domestic and foreign research reactors which had geometries considerably different from round or square bundles of plates or rods. As such, they cannot be dispositioned in current H-Canyon dissolver inserts so a new, multi-function dissolver insert may be considered. While this is not a current mission, it is believed that this study's scoping calculations demonstrate the feasibility of the site taking such a mission. At the H-Canyon facility, a dissolver is a large stainless steel pot, loaded with a nitric acid solution into which uranium-alloy fuel is dissolved. The dissolver uses a device called an insert to feed the fuels to the acid solution in a controlled manner. Most fuel forms fit into one of the existing inserts which include one with ten {approx}5-inch diameter circular wells, one with four {approx}4.5 inch by {approx}15 inch slab wells, and one specifically designed for the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). This study considered five bounding fuel candidates for scoping the potential new insert. The fuels include a generic annular plate fuel (APF), the Tower Shield Reactor (TSR) fuel elements, the Reactor A Haute Flux (RHF) core, Knolls Atomic Power Laboratory (KAPL) reactor fuel, and SLOWPOKE cores. These are expected to bound a range of proposed fuel candidates. Scoping studies were made to establish geometric restrictions for the new dissolver insert and to determine if these fuels could safely be dissolved. Homogenous models were used for the scoping study due to time constraints. Computational modeling was performed using KENOVI in the SCALE 6.1 code package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring Radiochemical Processing Streams for the 238 Pu Supply Program with Process Pulse II

Oak Ridge National Laboratory (ORNL) is developing advanced spectroscopic and real-time monitoring capabilities to improve the timeliness of analytical measurements and process decisions for the 238Pu Supply Program. Reducing the time, resources, and costs associated with each production campaign is critical because overlapping campaigns will be required to meet the production goals of the National Aeronautics and Space Administration. Real-time, in situ analytical measurements in the heavily shielded hot cells at the Radiochemical Engineering Development Center (REDC) will allow for rapid process information feedback and operational benefits that help the 238Pu supply program scale-up production efforts. Noteworthy steps were taken during Campaign 5 to establish the ability to monitor processing streams in real time with spectrophotometry and a commercially available online monitoring software called The Unscrambler X Process Pulse II (PP) multivariate statistical process monitoring system by Camo Analytics (version 5.60). PP automates univariate-type calculations within the software itself and executes multivariate models built using The Unscrambler X (version 10.4 or newer). The Unscrambler is a commercially available data analysis software made by the same company. PP is composed of easy-to-use-tools for all personnel, including data scientists and technicians. The software can be used to plot analyte concentration profiles, spectral data, and other process variables in real time. All process data are represented in a single view with interactive charts useful for viewing how a process evolves over time.

07 ISOTOPE AND RADIATION SOURCES↗

BISON Simulated and Experimental Fission Product Release Comparisons from Reradiated AGR-3/4 Compacts During High Temperature Heating Tests

The fuel performance modeling code BISON was used to predict the release of fission products iodine-131 (131I), xenon-133 (133Xe), and krypton-85 (85Kr) from four re-irradiated AGR-3/4 fuel compacts containing tristructural isotropic (TRISO) coated particles during high-temperature isothermal heating tests. The AGR-3/4 fuel compacts were irradiated in the Advanced Test Reactor (ATR) as part of the third and fourth series of planned experiments to support the Advanced Gas Reactor (AGR) Program. They were subsequently stored and re-irradiated in the Neutron Radiography (NRAD) reactor for approximately five days and then stored for another five to eight days before being subjected to isothermal heating tests in the Fuel Accident Condition Simulation (FACS furnace) for 200 to 300 hours at temperatures between 1000°C and 1600°C to evaluate fission product release at elevated temperatures. New nuclide-specific fission product source term models for the three nuclides of interest were developed using the reactor multiphysics code Griffin and implemented into BISON to support this work. The new source term models were incorporated into coupled compact- and particle-scale BISON simulations, which predict spatially- and temporally-resolved radionuclide generation, radioactive decay, transport, and release throughout the entire irradiation history, including the initial ATR irradiation, NRAD re-irradiations, FACS heating tests, and intermediate periods spent in storage. The experimentally measured fission product release from the heating tests were compared to modeling release predictions calculated by BISON to evaluate how well the code compares to experimental results. Overall, the experimental measured and BISON predicted comparative release results varied but generally agreed to within 5 particle equivalents. Comparative release results identified general observations to take into consideration to help refine future models and reduce uncertainties associated with both the measurement results and predictive results. This includes developing new uranium oxycarbide (UCO) specific kernel diffusivities for the three isotopes examined to more accurately reflect the material properties of the fuel form. Deriving new diffusivities will aid in producing a more informed BISON model

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Collaboration and Commitment to Sealed Source Safety, Security, and Disposition - 13627

EnergySolutions, the Division of Radiation Control at the Utah Department of Environmental Quality (UDEQ), the Conference of Radiation Control Program Directors (CRCPD), and the Department of Energy's Global Threat Reduction Initiative (GTRI) are collaborating on a truly innovative effort to expand opportunities for cost-effective sealed source disposal. These entities have developed a first-of-its-kind initiative to dispose of certain sealed sources at the EnergySolutions disposal facility near Clive, Utah, which normally cannot accept sealed sources of any type. This creative and collaborative effort to improve radiation health, safety, and security exemplifies the spirit and commitment represented by the Richard S. Hodes, M.D. Honor Lecture Award, which is presented annually at the Waste Management Symposia by the Southeast Compact Commission to encourage environmental professionals and political leaders to develop innovative approaches to waste management in the United States. The participants in the collaborative initiative are honored to receive special recognition for their efforts thus far. They also recognize that the hard work remains to be done. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Thermal Neutron Die-Way-Time Studies for P and DGNAA of Radioactive Waste Drums at the MEDINA Facility

In Germany, radioactive waste with negligible heat production has to pass through a process of quality checking in order to check its conformance with national regulations prior to its transport, intermediate storage and final disposal. Additionally to its radioactive components, the waste may contain non-radioactive chemically toxic substances that can adversely affect human health and pollute the environment, especially the ground water. After an adequate decay time, the waste radioactivity will become harmless but the non-radioactive substances will persist over time. In principle, these hazardous substances may be quantified from traceability and quality controls performed during the production of the waste packages. As a consequence, a research and development program was initiated in 2007 with the aim to develop a nondestructive analytical technique for radioactive waste packages based on prompt and delayed gamma neutron activation analysis (P and DGNAA) employing a DT-neutron generator in pulsed mode. In a preliminary study it was experimentally demonstrated that P and DGNAA is suitable to determine the chemical composition of large samples. In 2010 a facility called MEDINA (Multi Element Detection based on Instrumental Neutron Activation) was developed for the qualitative and quantitative determination of nonradioactive, toxic elements and substances in 200-l steel drums. The determination of hazardous substances and elements is generally achieved measuring the prompt gamma-rays induced by thermal neutrons. Additional information about the composition of the waste matrix could be derived measuring the delayed gamma-rays from short life activation products. However a sensitive detection of these delayed gamma-rays requires that thermal neutrons have almost vanished. Therefore, the thermal neutron die-away-time has to be known in order to achieve an optimal discrimination between prompt and delayed gamma-ray spectra acquisition. Measurements Thermal neutron die-away times have been determined for the following cases: a) the empty chamber, b ) an empty 200-l steel drum, for a 200-l steel drum filled c) with concrete d) with polyethylene and e) with a mixture of polyethylene and concrete by measuring the prompt-gamma ray count rate of relevant isotopes like of {sup 1}H, {sup 10}B, {sup 12}C, {sup 28}Si, {sup 35}Cl, {sup 40}Ca and {sup 56}Fe which are emitted from different parts of the facility and the sample. Additionally, the average die-away-time was determined from the total detector count rate. The neutron generator was operated with a neutron emission of 8x10{sup 7} n.s{sup -1}, a neutron pulse with a length of 250 μs and a repetition time of 5 ms. The spectra were acquired between the neutron pulses over t{sub c}=500 μs after a pre-defined waiting time t{sub D} (multiple of 500 μs). The thermal neutron die-away time was ranging between 0.9 ms and 5 ms according to the sample composition. As an example the measured thermal neutron die-away-time Λ [μs] of a drum filled with concrete is presented. Detailed results of this study will be presented and discussed. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of Large Neutron Detectors Containing Lithium-Gadolinium-Borate Scintillator

This paper describes the development and testing of a neutron counter, spectrometer, and dosimeter that is compact, efficient, and accurate. A self-contained neutron detection instrument has wide applications in health physics, scientific research, and programs to detect, monitor, and control strategic nuclear materials (SNM). The 1.3 liter detector head for this instrument is a composite detector with an organic scintillator containing uniformly distributed {sup 6}Li{sub 6}{sup nat}Gd{sup 10}B{sub 3}O{sub 9}:Ce (LGB:Ce) microcrystals. The plastic scintillator acts to slow impinging neutrons and emits light proportional to the energy lost by the neutrons as they moderate in the detector body. Moderating neutrons that have slowed sufficiently capture in one of the Lithium-6, Boron-10, or Gadolinium-157 atoms in the LGB:Ce scintillator, which then releases the capture energy in a characteristic cerium emission pulse. The measured captured pulses indicate the presence of neutrons. When a scintillating fluor is present in the plastic, the light pulse resulting from the neutron moderating in the plastic is paired with the LGB:Ce capture pulse to identify the energy of the neutron. About 2% of the impinging neutrons lose all of their energy in a single collision with the detector. There is a linear relationship between the pulse areas of this group of neutrons and energy. The other 98% of neutrons have a wide range of collision histories within the detector body. When these neutrons are 'binned' into energy groups, each group contains a distribution of pulse areas. This data was used to assist in the unfolding of the neutron spectra. The unfolded spectra were then validated with known spectra, at both neutron emitting isotopes and fission/accelerator facilities. Having validated spectra, the dose equivalent and dose rate are determined by applying standard, regulatory damage coefficients to the measured neutron counts for each energy bin of the spectra. Testing at the Los Alamos Neutron Science Center (LANSCE), Edwards Accelerator Laboratory (EAL) at Ohio University and the Radiation Center at University of Massachusetts-Lowell has demonstrated that the instrument can measure neutrons and their spectra over the range between 0.8 MeV and 150 MeV with an uncertainty of only ± 8%. An independent test of the LGB:Ce neutron spectrometer was conducted by a US Defense Threat Reduction Agency (DTRA) team at the Idaho National Laboratory (INL). The results of this evaluation showed that the neutron spectrometer accurately identified bare radioactive isotopes by their spectra. Further, masking and shielding materials alter those spectra in predictable ways that permit an extrapolation from the observed spectra back to the identity of the isotopic spectrum. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validating automated resonance evaluation with synthetic data

The integrity and precision of nuclear data are crucial for a broad spectrum of applications, from national security and nuclear reactor design to medical diagnostics, where the associated uncertainties can significantly impact outcomes. A substantial portion of uncertainty in nuclear data originates from the subjective biases in the evaluation process, a crucial phase in the nuclear data production pipeline. Recent advancements indicate that automation of certain routines can mitigate these biases, thereby standardizing the evaluation process and enhancing reproducibility. This research aims to provide a methodology, framework, and metrics for the validation of automated nuclear data evaluation software leveraging high-quality synthetic data that closely mimic real experimental observables. An introduced error metric provides a scale and intuitive measure of the evaluation quality by quantifying the estimate’s accuracy and performance across the specified energy range. Synthetic data provides access to experimental observables and underlying resonance parameters, enabling comparison of different evaluations. The methodology is demonstrated using Ta-181 isotope data in the resolved resonance region. The Automated Resonance Identification Subroutine (ARIS), which operates without prior resonance information, was used to test and showcase the framework’s capabilities utilizing the proposed error metrics. The results demonstrate the effectiveness of the proposed approach and framework for optimizing software parameters and testing hypotheses through “what-if” controlled experiments, such as modifying assumptions about experimental conditions or average resonance parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of material isotopics and atom number ratio with α-particle spectroscopy for a NIFFTE fission Time Projection Chamber actinide target

In this work, we present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target using α-spectroscopy and mass spectrometry. The double-sided actinide target, with predominantly 239 Pu on one side and 235 U on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is needed to extract an absolute measurement fission cross-section ratio. The 239 Pu/ 235 U atom number ratio was measured with a combination of mass spectrometry and α-spectroscopy with a planar silicon detector achieving uncertainties of less than 1%. Different strategies for estimating isotopic concentration from the α-spectrum are presented to demonstrate the potential of these methods for non-destructive target assay. We found that a combination of fitting spectra with constraints from mass spectrometry, and summing counts in a region of the spectrum provided the most consistent results with the lowest uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of a Density Law via Python for Aqueous Plutonium Nitrate

A predictive density tool has been developed in Python to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer Method and an empirical method were implemented into the tool, allowing for plutonium nitrate density calculations. Additionally, the Python tool can generate atom densities for a MCNP6.2 material card using the density from the selected method and directly the densities into a prepared MCNP6 input text file. The material card and density are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, plutonium isotope weight percentages and impurity concentrations. The Python tool has been validated and verified against the International Handbook of Evaluated Criticality Safety Benchmark Experiments to predict densities within a root mean square error of 1.0% for the Pitzer method and 1.8% for the empirical method. These errors in density were shown to lead to a ±0.5% error in MCNP6.2 calculated k effective for the Pitzer method and a ±1.7% error for the Empirical method. Simultaneous work is also being done at the University of New Mexico and Los Alamos National Laboratory to create a similar tool for plutonium chloride solutions, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also lead the way towards a better understanding of solution systems and potential relaxation in the conservatism of the current aqueous plutonium processing limits.

97 MATHEMATICS AND COMPUTING↗

Preliminary Mark-18A (Mk-18A) Target Material Recovery Program Product Acceptance Criteria

The Mk-18A Target Material Recovery Program (MTMRP) was established in 2015 to preserve the unique materials, e.g. 244 Pu, in 65 previously irradiated Mk-18A targets for future use. This program utilizes existing capabilities at SRS and Savannah River National Laboratory (SRNL) to process targets, recover materials from them, and to package the recovered materials for shipping to ORNL. It also utilizes existing capabilities at ORNL to receive and store the recovered materials, and to provide any additional processing of the recovered materials or residuals required to prepare them for future beneficial use. The MTMRP is presently preparing for the processing of these valuable targets which is expected to begin in ~2019. As part of the preparations for operations, this report documents the preliminary acceptance criteria for the plutonium and heavy curium materials to be recovered from the Mk-18A targets at SRNL for transport and storage at ORNL. These acceptance criteria were developed based on preliminary concepts developed for processing, transporting, and storing the recovered Mk-18A materials. They will need to be refined as these concepts are developed in more detail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗