Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Induction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Thermodynamic insight into AnO 2 + bonding from ThH + /UH + reactions studied by inductively coupled plasma tandem mass spectrometry

The bonding mechanisms of actinides have been a focus of fundamental research over the past few decades. In the present study, reactions of the simplest actinide-containing species, ThH + and UH + , with O 2 and CO 2 are investigated by inductively coupled plasma tandem mass spectrometry. The reactions of ThH + and UH + with O 2 are efficient, and the reactions of ThH + and UH + with CO 2 display reduced reaction efficiencies. For both reactions involving CO 2 , ThO 2 + and UO 2 + are observed; however, there is a clear barrier to ThO 2 + formation whereas UO 2 + forms through an exothermic, barrierless process. The experimental observations and available thermodynamic information are used to predict the outcomes of reactions involving the later AnH + . The anticipated reaction enthalpies for Pa–Am display a clear correlation with the promotion energy of An + to a 6d 2 electronic configuration, E p (6d 2 ), although a shift in the slope of the correlation of reaction enthalpies and E p (6d 2 ) suggests that there is likely a change in bonding mechanism that starts with Np + . Similar shifts have also been noted in previous studies. Beginning with Np + , the 6d orbitals become less accessible than they are for the earlier An + as measured by E p (6d 2 ), and this accessibility of the 6d orbitals may drive actinide bonding.

5f orbitals↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Range Hood Use and Effectiveness in Reducing Indoor Air Pollution During Gas and Induction Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. The study installed electric induction stoves and repeated measurements over three 2-week intensive periods, at baseline and at the end of two consecutive 3-month study phases. Stove replacements occurred at the start of Phase 1 or Phase 2 by random assignment. There were 4184 cooking events identified by automated analysis of time-series data from temperature sensors mounted above the cooktops and 1038 related range hood usage events detected from data recorded by anemometers, smart plugs, or motor loggers. Analysis of 1-minute resolved PM2.5 and NO 2 data identified and quantified 2685 PM 2.5 events and 2606 NO 2 events. Range hood use was characterized as a binary variable (>3 min vs. <3 min use). Range hood use was more common during cooking events associated with particle emissions and longer cooking durations. PM 2.5 concentrations during events with range hood use were comparable to those without use, which could result from limited effectiveness or if range hoods were preferentially used during higher-emission cooking scenarios. In homes with gas cooking, integrated NO 2 concentrations were about 45 percent higher during cooking events with no range hood use compared to those range hood use. The lowest pollutant levels were observed when the range hood operated for more than half of the cooking duration. These findings show that operation of venting range hood during cooking can substantially reduce short-term indoor exposure NO 2 in homes with gas cooking.

Fang, Yi↗

Variation of plasma parameters on boundary conditions in an inductively coupled plasma source for hyperthermal neutral beam generation

The variations of plasma parameters on the boundary conditions, especially potential, of plasmas were measured in an inductively coupled plasma source developed to generate a hyperthermal neutral beam. Hyperthermal neutrals can be produced by Auger neutralization when ions with low energy are neutralized by impinging on a metal surface called a reflector. However, the reflector is a significant source of ion drain when it is biased to a negative potential. The plasma potential can be negative with respect to the grounded chamber potential while the reflector is negatively biased, but other plasma parameters, namely density and temperature, are not sensitive to the reflector bias. If the electron loss current into the chamber wall is governed by the space charge limited current law, sustainment of the plasma with a negative potential can be explained in terms of the charge balance equations for quasineutrality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A ground-based radio frequency inductively coupled plasma apparatus for atomic oxygen simulation in low Earth orbit

A radio frequency (rf) inductively coupled plasma apparatus has been developed to simulate the atomic oxygen environment encountered in low Earth orbit (LEO). Basing on the novel design, the apparatus can achieve stable, long lasting operation, pure and high density oxygen plasma beam. Furthermore, the effective atomic oxygen flux can be regulated. The equivalent effective atomic oxygen flux may reach (2.289-2.984)x10{sup 16} at./cm{sup 2} s at an oxygen pressure of 1.5 Pa and rf power of 400 W. The equivalent atomic oxygen flux is about 100 times than that in the LEO environment. The mass loss measured from the polyimide sample changes linearly with the exposure time, while the density of the eroded holes becomes smaller. The erosion mechanism of the polymeric materials by atomic oxygen is complex and involves initial reactions at the gas-surface interface as well as steady-state material removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-induced fluorescence measurements in an inductively coupled plasma reactor

The authors report on laser-induced fluorescence (LIF) measurements of ion velocity distribution functions made in an inductively coupled plasma reactor with a pulsed plasma source. Vertical and radial velocities have been measured at thousands of spatial locations within a plane, and the LIF data have been calibrated to a 96 GHz microwave interferometer. The ions are observed to approach the Bohm velocity and the inferred electric potential within the presheath agrees well with theory. A two-dimensional flow pattern of the ion velocity above the substrate is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Langmuir probe data analysis for a magnetized inductive radio-frequency discharge

The properties of an inductively coupled argon plasma in a uniform magnetic field, at pressures of the order of 0.1 Pa, in the presence of a weak current-free electric double layer, are measured with a plane Langmuir probe. The static current-voltage probe characteristics, recorded on the symmetry axis of the experimental device, both in the plasma source and in the main chamber of the setup, showed the existence of two electron populations with different temperatures. The axial profiles of plasma parameters, such as the plasma potential and the cold and hot electron temperatures, offered a new insight into such a complex system. However, both the external magnetic field and the two electron populations contribute to the difficulty of calculation of the local plasma density. A method for solving this problem, involving the definition of an effective electron temperature, is also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inductive coupled radio frequency plasma bridge neutralizer

A 13.56 MHz radio frequency plasma bridge neutralizer (rf-PBN) for ion thruster applications as well as ion beam surface processing of insulating materials is presented. The energy for the plasma excitation is inductively coupled into the plasma chamber. Because no components are located inside the plasma, the lifetime of the rf-PBN is expected to be very long. A compact tuning system adapts the input power to the plasma impedance. The electron current may be controlled over a wide range by the rf input power. An electron current of up to 1.6 A has been extracted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of the reactor wall composition on radicals' densities and total pressure in Cl{sub 2} inductively coupled plasmas: II. During silicon etching

In an industrial inductively coupled plasma reactor dedicated to silicon etching in chlorine-based chemistry, the density of Cl{sub 2} molecules and the gas temperature are measured by means of laser absorption techniques, the density of SiCl{sub x} (x{<=}2) radicals by broadband absorption spectroscopy, the density of SiCl{sub 4} and ions by mass spectrometry, and the total gas pressure with a capacitance gauge. These measurements permit us to estimate the mole fractions of Cl, SiCl{sub 4}, and etch product radicals when etching a 200 mm diameter silicon wafer. The pure Cl{sub 2} plasma is operated in well prepared chamber wall coating with a thin film of SiOCl, AlF, CCl, or TiOCl. The impact of the chemical nature of the reactor wall's coatings on these mole fractions is studied systematically. We show that the reactor wall coatings have a huge influence on the radicals densities, but this is not only from the difference on Cl-Cl recombination coefficient on different surfaces. During silicon etching, SiCl{sub x} radicals sticking on the reactor walls are etched by Cl atoms and recycled into the plasma by forming volatile SiCl{sub 4}. Hence, the loss of Cl atoms in etching the wall deposited silicon is at least as important as their wall recombination in controlling the Cl atoms density. Furthermore, because SiCl{sub 4} is produced at high rate by both the wafer and reactor walls, it is the predominant etching product in the gas phase. However, the percentage of redeposited silicon that can be recycled into the plasma depends on the amount of oxygen present in the plasma: O atoms produced by etching the quartz roof window fix Si on the reactor walls by forming a SiOCl deposit. Hence, the higher the O density is, the lower the SiCl{sub 4} density will be, because silicon is pumped by the reactor walls and the SiOCl layer formed is not isotropically etched by chlorine. As a result, in the same pure Cl{sub 2} plasma at 20 mTorr, the SiCl{sub x} mole fraction can vary from 18% in a SiOCl-coated reactor, where the O density is the highest, to 62% in a carbon-coated reactor, where there is no O. In the latter case, most of the Cl mass injected in the reactor is stored in SiCl{sub 4} molecules, which results in a low silicon etch rate. In this condition, the Cl mass balance is verified within 10%, and from the silicon mass balance we concluded that SiCl{sub x} radicals have a high surface loss probability. The impact of the reactor wall coating on the etching process is thus important, but the mechanisms by which the walls control the plasma chemistry is much more complicated than a simple control through recombination reaction of halogen atoms on these surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the growth of carbon nanofibers on glass with a Cr layer by inductively coupled plasma chemical vapor deposition: The effect of Ni film thickness

We have studied the effect of the thickness of catalytic Ni film for the growth of vertically aligned carbon nanofibers (VA-CNFs) on glass substrates coated with a conductive underlayer of Cr. Both the pretreatment process through which the catalytic Ni nanoparticles were formed and the growth of well-aligned CNFs were carried out in an inductively coupled plasma chemical vapor deposition (ICP-CVD) system. The VA-CNFs were characterized by scanning electron microscopy, Raman spectroscopy, as well as field emission measurements. The results of VA-CNF growth shows that as the Ni film thicknesses decrease, not only the length but also the density of the CNFs drop, although the density of catalytic Ni nanoparticles increases. The variation of CNF density with Ni film thicknesses is believed to be a result of the detachment of the CNFs from the substrate, caused by the electrostatic force produced by the plasma sheath electric field, as well as an ion-enhanced chemical etching effect due to atomic/ionic hydrogen, during the ICP-CVD growth. A field emission measurement apparatus based on a metallic probe of spherical anode structure was also constructed in this study. An electrostatic image model was employed to determine the electric field distribution on the cathode surface. Along with the standard F-N field emission model, the dependence of field emission current density on the cathode surface electric field, as well as an effective field enhancement factor, were extracted from the current-voltage measurement results. The threshold electric field (E{sub threshold}, for a current density of 1 mA/cm{sup 2}) increases from 9.2 V/{mu}m to 13.1 V/{mu}m, and then drops to 11.5 V/{mu}m for the CNFs with Ni film thicknesses of 20 nm, 30 nm, and 40 nm, respectively. The electrostatic model results also indicate that the 20 nm case has the greatest space-charge effect on the emission current, consistent with the growth results that the 20 nm case has the lowest CNF density. On the other hand, the CNF length of the 40 nm case is longer than that of the 30 nm one, while the densities are nearly the same; as a result, E{sub threshold} for the 30 nm case is higher.

36 MATERIALS SCIENCE↗

Etching characteristics of LiNbO{sub 3} in reactive ion etching and inductively coupled plasma

The etching characteristics of congruent LiNbO{sub 3} single crystals including doped LiNbO{sub 3} and proton-changed LiNbO{sub 3} have been studied in reactive ion etching (RIE) and inductively coupled plasma (ICP) etching tools, using different recipes of gas mixtures. The effects of parameters including working pressure, RIE power, and ICP power are investigated and analyzed by measurement of etching depth, selectivity, uniformity, etched surface state, and sidewall profile by means of focused ion beam etching, energy-dispersive x-ray analysis, secondary ion mass spectroscopy, scanning electron microscopy, and surface profilometry. The effects of a sample carrier wafer coating have also been investigated. Optimized processes with high etching rates, good mask selectivity, and a near-vertical profile have been achieved. Ridge waveguides on proton-exchanged LiNbO{sub 3} have been fabricated and optically measured.

36 MATERIALS SCIENCE↗

Development of 40 MHz inductively coupled plasma source and frequency effects on plasma parameters

A large-area inductively coupled plasma (ICP) source capable of securing azimuthal plasma uniformity at a 40.00 MHz has been developed. The antenna, referred to as a capacitor distributed resonance antenna, minimizes the azimuthally nonuniform antenna capacitive field with eight distributed vertical capacitors. The antenna was designed to maximize the antenna current using L-C series resonance. Based on plasma diagnostics with a 13.56 MHz conventional ICP, comparative analyses were performed in terms of the plasma density, electron temperature, and frequency characteristics of the electron energy probability function (EEPF). In addition, the frequency dependency of the EEPF was found in the collisional ({nu}{sub en}>{omega}), normal skin [v{sub th}/{delta}<<({omega}{sup 2}+{nu}{sub en}{sup 2}){sup 1/2}] regime and the physical causes of were examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uniformity of internal linear-type inductively coupled plasma source for flat panel display processing

The variation in plasma uniformity over an extremely large size inductively coupled plasma (ICP) source of 2750x2350 mm{sup 2} was examined. An internal linear-type antenna called ''double comb-type antenna'' was used as the ICP source. A plasma density of {approx}1.4x10{sup 11}/cm{sup 3} could be obtained at 5 mTorr Ar by applying 10 kW rf power to the source at a frequency of 13.56 MHz. An increase in rf power from 1 to 10 kW improved the plasma uniformity over a substrate area of 2300x2000 mm{sup 2} from 18.1% to 11.4%. The improvement in uniformity of the internal ICP source was attributed to the increase in plasma density near the wall.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma power measurement and hysteresis in the E-H transition of a rf inductively coupled plasma system

An experimental investigation of the argon plasma behavior near the E-H transition in an inductively coupled Gaseous Electronics Conference reference cell is reported. Electron density and temperature, ion density, argon metastable density, and optical emission measurements have been made as function of input power and gas pressure. When plotted versus plasma power, applied power corrected for coil and hardware losses, no hysteresis is observed in the measured plasma parameter dependence at the E-H mode transition. This suggests that hysteresis in the E-H mode transition is due to ignoring inherent power loss, primarily in the matching system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field-reversed configuration formation scheme utilizing a spheromak and solenoid induction

A new field-reversed configuration (FRC) formation technique is described, where a spheromak transitions to a FRC with inductive current drive. The transition is accomplished only in argon and krypton plasmas, where low-n kink modes are suppressed; spheromaks with a lighter majority species, such as neon and helium, either display a terminal tilt-mode, or an n=2 kink instability, both resulting in discharge termination. The stability of argon and krypton plasmas through the transition is attributed to the rapid magnetic diffusion of the currents that drive the kink-instability. The decay of helicity during the transition is consistent with that expected from resistivity. This observation indicates a new scheme to form a FRC plasma, provided stability to low-n modes is maintained, as well as a unique situation where the FRC is a preferred state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical investigation of cooling effect on platinum nanoparticle formation in inductively coupled thermal plasmas

A mathematical model is developed to simulate the comprehensive systems of platinum nanoparticle synthesis using an argon inductively coupled thermal plasma flow with forced cooling portions. Numerical investigation using the model is conducted to clarify and discuss the effects of several cooling methods on the formation mechanisms of nanoparticles in distinctive thermofluid fields with strong two dimensionality. The computational results show that cooling by a radial gas injection, and a counterflow, engenders the remarkable promotion of nanoparticles.

36 MATERIALS SCIENCE↗

Modeling of an Inductive Negative Ion Source for Neutral Beam Injection

We present a self-consistent two-dimensional model of a high-power inductive plasma source for negative ion production in hydrogen. The model is quasi-neutral and describes the transport and chemistry of different particle species by fluid equations including inertia and viscosity terms, coupled with the electromagnetic fields from the Maxwell equations. Results for typical conditions show a depletion of the neutral density in the plasma center and a possible reduction of wall losses due to the Lorentz force from the driving field at lower frequencies (<20 MHz)

43 PARTICLE ACCELERATORS↗

Effects of impedance matching network on the discharge mode transitions in a radio-frequency inductively coupled plasma

In inductively coupled plasma sources, discharge transitions from electrostatic mode (E mode) to electromagnetic mode (H mode) and from H mode to E mode occur. In previous studies, only a few works paid attention to the effects of the impedance matching network. Cunge et al. [Plasma Sources Sci. Technol. 8, 576 (1999)] investigated the E-H and H-E mode transitions under two different impedance matching situations, but no physical mechanism or interpretation was presented. This issue is remained to be systematically and quantitatively investigated, and the underlying mechanism to be unveiled. In this paper, the effects of the impedance matching network were experimentally studied in electropositive argon gas by varying the series capacitance in an inversely L-shaped matching network. The positive and negative feedback regions are established according to the effect of varying the series capacitance on the output power of the rf power supply. It was found that under the same experimental parameters, the discharge mode transitions are apt to be discontinuous and continuous in the positive and negative feedback regions, respectively. In addition, the critical coil rf current (or applied power) at the mode transition, the hysteretic loop width, and the difference in applied power during the discharge mode transition vary with the series capacitance. The critical coil rf current at the E-H mode transition is not always higher than that at the H-E mode transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗