Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Automated System for Early Breast Cancer Detection in Mammograms

The increasing demand on mammographic screening for early breast cancer detection, and the subtlety of early breast cancer signs on mammograms, suggest an automated image processing system that can serve as a diagnostic aid in radiology clinics. We present a fully automated algorithm for detecting clusters of microcalcifications that are the most common signs of early, potentially curable breast cancer. By using the contour map of the mammogram, the algorithm circumvents some of the difficulties encountered with standard image processing methods. The clinical implementation of an automated instrument based on this algorithm is also discussed.

Bankman, Isaac N.↗

Width Criterion For Weld-Seam-Tracking Data

Image-processing algorithm in "through-torch-vision" (T3V) system developed to guide gas/tungsten arc welding robot along weld seam modified, according to proposal, reducing incidence of inaccurate tracking of weld seam. Developmental system intended to provide closed-loop control of motion of welding robot along weld seam on basis of lines in T3V image identified by use of image-processing algorithm and assumed to coincide with edges of weld seam. Use of width criterion prevents tracking of many false pairs of lines, with consequent decrease in incidence of inaccurate tracking and increase in confidence in weld-tracking capability of robotic welding system.

Lincir, Mark R.↗

Processing Near-Infrared Imagery of the Orion Heatshield During EFT-1 Hypersonic Reentry

The Scientifically Calibrated In-Flight Imagery (SCIFLI) team captured high-resolution, calibrated, near-infrared imagery of the Orion capsule during atmospheric reentry of the EFT-1 mission. A US Navy NP-3D aircraft equipped with a multi-band optical sensor package, referred to as Cast Glance, acquired imagery of the Orion capsule's heatshield during a period when Orion was slowing from approximately Mach 10 to Mach 7. The line-of-sight distance ranged from approximately 65 to 40 nmi. Global surface temperatures of the capsule's thermal heatshield derived from the near-infrared intensity measurements complemented the in-depth (embedded) thermocouple measurements. Moreover, these derived surface temperatures are essential to the assessment of the thermocouples' reliance on inverse heat transfer methods and material response codes to infer the surface temperature from the in-depth measurements. The paper describes the image processing challenges associated with a manually-tracked, high-angular rate air-to-air observation. Issues included management of significant frame-to-frame motions due to both tracking jerk and jitter as well as distortions due to atmospheric effects. Corrections for changing sky backgrounds (including some cirrus clouds), atmospheric attenuation, and target orientations and ranges also had to be made. The image processing goal is to reduce the detrimental effects due to motion (both sensor and capsule), vibration (jitter), and atmospherics for image quality improvement, without compromising the quantitative integrity of the data, especially local intensity (temperature) variations. The paper will detail the approach of selecting and utilizing only the highest quality images, registering several co-temporal image frames to a single image frame to the extent frame-to-frame distortions would allow, and then co-adding the registered frames to improve image quality and reduce noise. Using preflight calibration data, the registered and averaged infrared intensity images were converted to surface temperatures on the Orion capsule's heatshield. Temperature uncertainties will be discussed relative to uncertainties of surface emissivity and atmospheric transmission loss. Comparison of limited onboard surface thermocouple data to the image derived surface temperature will be presented.

Spisz, Thomas S.↗

Benefits of utilizing CellProfiler as a characterization tool for U–10Mo nuclear fuel

Automated image processing techniques have the potential to aid in the performance evaluation of nuclear fuels by eliminating judgment calls that may vary from person-to-person or sample-to-sample. Analysis of in-core fuel performance is required for design and safety evaluations related to almost every aspect of the nuclear fuel cycle. This study presents a methodology for assessing the quality of uranium–molybdenum fuel images and describes image analysis routines designed for the characterization of several important microstructural properties. The analyses are performed in CellProfiler, an open-source program designed to enable biologists without training in computer vision or programming to automatically extract cellular measurements from large image sets. The quality metric scores an image based on three parameters: the illumination gradient across the image, the overall focus of the image, and the fraction of the image that contains scratches. The metric presents the user with the ability to ‘pass’ or ‘fail’ an image based on a reproducible quality score. Passable images may then be characterized through a separate CellProfiler pipeline, which enlists a variety of common image analysis techniques. The results demonstrate the ability to reliably pass or fail images based on the illumination, focus, and scratch fraction of the image, followed by automatic extraction of morphological data with respect to fission gas voids, interaction layers, and grain boundaries. - Graphical abstract: Display Omitted - Highlights: • A technique is developed to score U–10Mo FIB-SEM image quality using CellProfiler. • The pass/fail metric is based on image illumination, focus, and area scratched. • Automated image analysis is performed in pipeline fashion to characterize images. • Fission gas void, interaction layer, and grain boundary coverage data is extracted. • Preliminary characterization results demonstrate consistency of the algorithm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Backscatter x-ray development for space vehicle thermal protection systems

The Backscatter X-Ray (BSX) imaging technique is used for various single sided inspection purposes. Previously developed BSX techniques for spray-on-foam insulation (SOFI) have been used for detecting defects in Space Shuttle External Tank foam insulation. The developed BSX hardware and techniques are currently being enhanced to advance Non-Destructive Evaluation (NDE) methods for future space vehicle applications. Various Thermal Protection System (TPS) materials were inspected using the enhanced BSX imaging techniques, investigating the capability of the method to detect voids and other discontinuities at various locations within each material. Calibration standards were developed for the TPS materials in order to characterize and develop enhanced BSX inspection capabilities. The ability of the BSX technique to detect both manufactured and natural defects was also studied and compared to through-transmission x-ray techniques. The energy of the x-ray, source to object distance, angle of x-ray, focal spot size and x-ray detector configurations were parameters playing a significant role in the sensitivity of the BSX technique to image various materials and defects. The image processing of the results also showed significant increase in the sensitivity of the technique. The experimental results showed BSX to be a viable inspection technique for space vehicle TPS systems.

07 ISOTOPE AND RADIATION SOURCES↗

Synchrotron X-ray based particle image velocimetry to measure multiphase streamflow and densitometry

Synchrotron-based radiation techniques are increasingly used in the field of flow condition measurements. As a complicated multiphase flow, cavitation has been investigated in a wide variety of industrial fields, to prevent damages on spillways at large dams or intensify the bacteria eradication rate during water treatments. To control the detrimental effects of cavitating flows, the dynamics of and mechanisms affecting cavitation development shall be visualized and identified in real-time. Due to the large reflection and scattering effects of multiphase flow, standard visible-light imaging technologies cannot penetrate vapor bubbles and provide extremely limited information. In this study, the synchrotron source emitted high-flux X-ray pulses are used to capture flow motion and visualize internal structures with sufficiently high spatial and temporal resolutions. The image processing procedures on raw x-ray images are developed using 2D Fourier transform (FT) and wavelet transform (WT) to implement the contrast enhancement and de-noising. Through the edge detection algorithm, tracking either seeded particles or phase interfaces inside the opaque multiphase flow can be achieved to perform the particle image velocimetry. Further, with decomposing particle-only and particle-eliminated subplots from the X-ray phase-contrast image, the time-resolved velocity and void fraction fields are obtained simultaneously, paving a way for further flow condition analysis such as densitometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The simulation of 3D microcalcification clusters in 2D digital mammography and breast tomosynthesis

Purpose: This work proposes a new method of building 3D models of microcalcification clusters and describes the validation of their realistic appearance when simulated into 2D digital mammograms and into breast tomosynthesis images. Methods: A micro-CT unit was used to scan 23 breast biopsy specimens of microcalcification clusters with malignant and benign characteristics and their 3D reconstructed datasets were segmented to obtain 3D models of microcalcification clusters. These models were then adjusted for the x-ray spectrum used and for the system resolution and simulated into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. Six radiologists were asked to distinguish between 40 real and 40 simulated clusters of microcalcifications in two separate studies on 2D mammography and tomosynthesis datasets. Receiver operating characteristic (ROC) analysis was used to test the ability of each observer to distinguish between simulated and real microcalcification clusters. The kappa statistic was applied to assess how often the individual simulated and real microcalcification clusters had received similar scores (''agreement'') on their realistic appearance in both modalities. This analysis was performed for all readers and for the real and the simulated group of microcalcification clusters separately. ''Poor'' agreement would reflect radiologists' confusion between simulated and real clusters, i.e., lesions not systematically evaluated in both modalities as either simulated or real, and would therefore be interpreted as a success of the present models. Results: The area under the ROC curve, averaged over the observers, was 0.55 (95% confidence interval [0.44, 0.66]) for the 2D study, and 0.46 (95% confidence interval [0.29, 0.64]) for the tomosynthesis study, indicating no statistically significant difference between real and simulated lesions (p > 0.05). Agreement between allocated lesion scores for 2D mammography and those for the tomosynthesis series was poor. Conclusions: The realistic appearance of the 3D models of microcalcification clusters, whether malignant or benign clusters, was confirmed for 2D digital mammography images and the breast tomosynthesis datasets; this database of clusters is suitable for use in future observer performance studies related to the detectability of microcalcification clusters. Such studies include comparing 2D digital mammography to breast tomosynthesis and comparing different reconstruction algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes

Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and high patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software TEMA Motion is used to track the spot which marked the cage surface. Finally, by developing the MATLAB program, a Lissajous’ figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental data display

Methods for using a combination of computer-generated color graphics and image processing techniques to display a large data base of environment information are described. The data source can be either field data or mathematical models, reduced to summary statistics that characterize the data field as a whole. Sharp gradients are plotted into contour plots, which can also feature shades, degree of brightness, and saturation levels for fine-tuning the image. The basic concepts of digital image processing are reviewed, including location of the pixels, intensity mapping operations, pseudocolor enhancements, neighborhood averaging, and smoothing. Sample applications are presented in terms of emissions and air quality distributions over the south coast air basin of southern California.

Hussey, K. J.↗

SYSTEMATIC DE-SATURATION OF IMAGES FROM THE ATMOSPHERIC IMAGING ASSEMBLY IN THE SOLAR DYNAMICS OBSERVATORY

Extreme ultraviolet (EUV) images of solar flares provided by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamics Observatory (SDO) are often affected by saturation effects in their core, physically most interesting, region. We introduce an image reconstruction procedure that allows recovering information in the primary saturation domain using the secondary images produced by the diffraction fringes as input data. Such a procedure is based on standard image-processing tools like correlation, convolution, and back-projection. Its effectiveness is tested in the case of AIA/SDO observations of the 2013 July 8 flaring event.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian K-SVD Using Fast Variational Inference

Recent work in signal processing in general and image processing in particular deals with sparse representation related problems. Two such problems are of paramount importance: an overriding need for designing a well-suited overcomplete dictionary containing a redundant set of atoms— i.e., basis signals—and how to find a sparse representation of a given signal with respect to the chosen dictionary. Dictionary learning techniques, among which we find the popular K-singular value decomposition algorithm, tackle these problems by adapting a dictionary to a set of training data. A common drawback of such techniques is the need for parameter-tuning. In order to overcome this limitation, we propose a fullyautomated Bayesian method that considers the uncertainty of the estimates and produces a sparse representation of the data without prior information on the number of non-zeros in each representation vector. We follow a Bayesian approach that uses a three-tiered hierarchical prior to enforce sparsity on the representations and develop an efficient variational inference framework that reduces computational complexity. Furthermore, we describe a greedy approach that speeds up the whole process. Lastly, we present experimental results that show superior performance on two different applications with real images: denoising and inpainting.

97 MATHEMATICS AND COMPUTING↗

Digital mammography, cancer screening: Factors important for image compression

The use of digital mammography for breast cancer screening poses several novel problems such as development of digital sensors, computer assisted diagnosis (CAD) methods for image noise suppression, enhancement, and pattern recognition, compression algorithms for image storage, transmission, and remote diagnosis. X-ray digital mammography using novel direct digital detection schemes or film digitizers results in large data sets and, therefore, image compression methods will play a significant role in the image processing and analysis by CAD techniques. In view of the extensive compression required, the relative merit of 'virtually lossless' versus lossy methods should be determined. A brief overview is presented here of the developments of digital sensors, CAD, and compression methods currently proposed and tested for mammography. The objective of the NCI/NASA Working Group on Digital Mammography is to stimulate the interest of the image processing and compression scientific community for this medical application and identify possible dual use technologies within the NASA centers.

Clarke, Laurence P.↗

BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation

Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView’s image processing algorithms.

60 APPLIED LIFE SCIENCES↗

SU-E-J-46: Evaluation of the Accuracy of a Six Degree of Freedom Robotic Couch Using ConeBeam CT Images of the Isocal Phantom

Purpose The accuracy of Varian PerfectPitch six degree of freedom (DOF) robotic couch was examined using Varian Isocal phantom and cone-beam CT (CBCT) system. Methods CBCT images of the Isocal phantom were taken at different pitch and roll angles. The pitch and roll angles were varied from 357 to 3 degrees in one degree increments by input from service console, generating a total of 49 combinations with couch angle (yaw) zero. The center positions of the 16 tungsten carbide BBs contained in the Isocal were determined with in-house image processing software. Expected BBs positions at different rotation angles were determined mathematically by applying a combined translation/rotation operator to BB positions at zero pitch and roll values. A least square method was used to minimize the difference between the expected BB positions and their measured positions. In this way rotation angles were obtained and compared with input values from the console. Results A total of 49 CBCT images with voxel sizes 0.51 mm × 0.51 mm × 1 mm were used in analysis. Among the 49 calculations, the maximum rotation angle differences were 0.1 degree, 0.15 degree, and 0.09 degree, for pitch, roll, and couch rotation, respectively. The mean ± standard-deviation angle differences were 0.028±0.001 degree, −0.043±0.003 degree, and −0.009±0.001 degree, for pitch, roll, and couch rotation, respectively. The maximum isocenter shifts were 0.3 mm, 0.5 mm, 0.4 mm in x, y, z direction respectively following IEC6127 convention. The mean isocenter shifts were 0.07±0.02 mm, −0.05±0.06 mm, and −0.12±0.02 mm in x, y and z directions. Conclusion The accuracy of the Varian PerfectPitch six DOF couch was studied with CBCTs of the Isocal phantom. The rotational errors were less than 0.15 degree and isocenter shifts were less than 0.5 mm in any direction. This accuracy is sufficient for stereotactic radiotherapy clinical applications.

60 APPLIED LIFE SCIENCES↗

Simulation of Laser Ultrasonics for Detection of Surface-Connected Rail Defects

Laser ultrasonic produces frequencies in the MHz range, enabling high accuracy and a strong ability to detect rail surface defects. This paper mainly studied on the simulation of detecting surface-connected rail defects on 60 kg rails with laser ultrasonic, established the finite element model of laser-excited ultrasonic Rayleigh wave, carried out the simulation, and verified the effectiveness of the technology through experiments. To solve the problem that laser ultrasonic is insensitive to the width of defects in actual detection, and unable to make quantitative detection of defects, this paper established a new model on the basis of improving the original model that has been verified, exciting ultrasonic at the two sides at the same time of a rail with two staggered beams of laser separately to detect irregular scratch defects on rail surface, and two groups of signal data were received through two probes. Each group of data can present the half-profile information of defects, and further form two detection images of the defect. At last, the two detection images were combined into a complete image through image processing. The results of the experiment indicate that the technology studied offers a new method for the effective quantitative detection of surface-connected defects on rail.

42 ENGINEERING↗

Fully depleted CMOS pixel sensor development and potential applications

CMOS pixel sensors are often opposed to hybrid pixel sensors due to their very different sensitive layer. In standard CMOS imaging processes, a thin (about 20 μm) low resistivity epitaxial layer acts as the sensitive volume and charge collection is mostly driven by thermal agitation. In contrast, the so-called hybrid pixel technology exploits a thick (typically 300 μm) silicon sensor with high resistivity allowing for the depletion of this volume, hence charges drift toward collecting electrodes. But this difference is fading away with the recent availability of some CMOS imaging processes based on a relatively thick (about 50 μm) high resistivity epitaxial layer which allows for full depletion. This evolution extents the range of applications for CMOS pixel sensors where their known assets, high sensitivity and granularity combined with embedded signal treatment, could potentially foster breakthrough in detection performances for specific scientific instruments. One such domain is the Xray detection for soft energies, typically below 10 keV, where the thin sensitive layer was previously severely impeding CMOS sensor usage. Another application becoming realistic for CMOS sensors, is the detection in environment with a high fluence of non-ionizing radiation, such as hadron colliders. However, when considering highly demanding applications, it is still to be proven that micro-circuits required to uniformly deplete the sensor at the pixel level, do not mitigate the sensitivity and efficiency required. Prototype sensors in two different technologies with resistivity higher than 1 kΩ, sensitive layer between 40 and 50 μm and featuring pixel pitch in the range 25 to 50 μm, have been designed and fabricated. Various biasing architectures were adopted to reach full depletion with only a few volts. Laboratory investigations with three types of sources (X-rays, β-rays and infrared light) demonstrated the validity of the approach with respect to depletion, keeping a low noise figure. Especially, an energy resolution of about 400 eV for 5 keV X-rays was obtained for single pixels. The prototypes have then been exposed to gradually increased fluences of neutrons, from 10{sup 13} to 5x10{sup 14} neq/cm{sup 2}. Again laboratory tests allowed to evaluate the signal over noise persistence on the different pixels implemented. Currently our development mostly targets the detection of soft X-rays, with the ambition to develop a pixel sensor matching counting rates as affordable with hybrid pixel sensors, but with an extended sensitivity to low energy and finer pixel about 25 x 25 μm{sup 2}. The original readout architecture proposed relies on a two tiers chip. The first tier consists of a sensor with a modest dynamic in order to insure low noise performances required by sensitivity. The interconnected second tier chip enhances the read-out speed by introducing massive parallelization. Performances reachable with this strategy combining counting and integration will be detailed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Virtual Diagnostic Interface: Aerospace Experimentation in the Synthetic Environment

The Virtual Diagnostics Interface (ViDI) methodology combines two-dimensional image processing and three-dimensional computer modeling to provide comprehensive in-situ visualizations commonly utilized for in-depth planning of wind tunnel and flight testing, real time data visualization of experimental data, and unique merging of experimental and computational data sets in both real-time and post-test analysis. The preparation of such visualizations encompasses the realm of interactive three-dimensional environments, traditional and state of the art image processing techniques, database management and development of toolsets with user friendly graphical user interfaces. ViDI has been under development at the NASA Langley Research Center for over 15 years, and has a long track record of providing unique and insightful solutions to a wide variety of experimental testing techniques and validation of computational simulations. This report will address the various aspects of ViDI and how it has been applied to test programs as varied as NASCAR race car testing in NASA wind tunnels to real-time operations concerning Space Shuttle aerodynamic flight testing. In addition, future trends and applications will be outlined in the paper.

Schwartz, Richard J.↗