Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

The Role of Auroral Imaging in Understanding Ionosphere-Inner Magnetosphere Interactions

The more ways we probe the ionosphere and inner magnetosphere, the better we can understand their interaction. For example, the multifaceted imaging of geospace with the IMAGE mission complements the more traditional in situ measurements made with many previous missions. Together they have enabled new knowledge of the ionosphere-magnetosphere (IM) coupling. The role of imaging the aurora in understanding this interaction has received renewed attention recently. Based on in situ data, such as FAST or DMSP, and our recent theories, we believe that imaging multiscale features of the aurora is a key component to gaining insight into the processes and mechanisms at work. This talk will explore how auroral imaging can be used to provide improved insight of the dynamics of IM interaction on micro and meso scales, with an emphasis on the current limitations and future possibilities of quantitative analyses.

Spann, Jim↗

Comparison of treatment strategies for Space Motion Sickness

Treatment strategies for Space Motion Sickness were compared using the results of postflight oral debriefings. Standardized questionnaires were administered to all crewmembers immediately following Space Shuttle flights by NASA flight surgeons. Cases of Space Motion Sickness were graded as mild, moderate or severe based on published criteria, and medication effectiveness was judged based on subjective reports of symptom relief. Since October 1989, medication effectiveness is reported inflight through Private Medical Conferences with the crew. A symptom matrix was analyzed for 19 crewmembers treated with an oral combination of scopolamine and dextroamphetamine (scopdex) and 15 crewmembers treated with promethazine delivered by intramuscular (IM) or suppository routes. Scopdex has been given preflight as prophaxis for Space Motion Sickness but analysis showed delayed symptom presentation in 9 crewmembers or failed to prevent symptoms in 7. Only three crewmembers who took scopdex had no symptoms inflight. Fourteen out of 15 crewmembers treated with IM promethazine and 6 of 8 treated with promethazine suppositories after symptom development had immediate (within 12 h) symptom relief and required no additional medication. There were no cases of delayed symptom presentation in the crewmembers treated with promethazine. This response is in contrast to untreated crewmembers who typically have slow symptom resolution over 72-96 h. We conclude that promethazine is an effective treatment of Space Motion Sickness symptoms inflight. NASA policy currently recommends treating crewmembers with Space Motion Sickness after symptom development, and no longer recommends prophylaxis with scopdex due to delayed symptom development and apparent variable absorption of oral medications during early flight days.

STS Shuttle Project↗

Insulin attenuates atrophy of unweighted soleus muscle by amplified inhibition of protein degradation

Unweighting atrophy of immature soleus muscle occurs rapidly over the first several days, followed by slower atrophy coinciding with increased sensitivity to insulin of in vitro protein metabolism. This study determined whether this increased sensitivity might account for the diminution of atrophy after 3 days of tall-cast hindlimb suspension. The physiological significance of the increased response to insulin in unweighted muscle was evaluated by analyzing in vivo protein metabolism for day 3 (48 to 72 hours) and day 4 (72 to 96 hours) of unweighting in diabetic animals either injected with insulin or not treated. Soleus from nontreated diabetic animals showed a similar loss of protein during day 3 (-16.2%) and day 4 (-14.5%) of unweighting, whereas muscle from insulin-treated animals showed rapid atrophy (-14.5%) during day 3 only, declining to just -3.1% the next day. Since fractional protein synthesis was similar for both day 3 (8.6%/d) and day 4 (7.0%/d) of unweighting in insulin-treated animals, the reduction in protein loss must be accounted for by a slowing of protein degradation due to circulating insulin. Intramuscular (IM) injection of insulin (600 nmol/L) stimulated in situ protein synthesis similarly in 4-day unweighted (+56%) and weight-bearing (+90%) soleus, even though unweighted muscle showed a greater in situ response of 2-deoxy-[3H]glucose uptake to IM injection of either insulin (133 nmol/L) or insulin-like growth factor-I (IGF-I) (200 nmol/L) than control muscle. These findings suggest that unweighted muscle is selectively more responsive in vivo to insulin, and that the slower atrophy after 3 days of unweighting was due to an increased effect of insulin on inhibiting protein degradation.

NASA Discipline Musculoskeletal↗

Isotopic Investigations of Nebular and Parent Body Processes with a High Sensitivity Ion Microprobe

NASA supported the development of the CAMECA ims 1270 ion microprobe at UCLA for applications in cosmochemistry. The primary investigations centered on measuring the microscopic distributions of key isotopic abundances in primitive meteoritic materials as a means of constraining the nature of important thermal and chemical processes in the solar nebula and the timescales associated with those processes. Our prior work on oxygen isotope anomalies in a wide variety of meteoritic materials had led us to a view of a spatially heterogeneous nebula, and in particular, a restricted region for CAI formation that is characterized by O-16-rich gas. Because of its production of CAIs in the energetic local environment near the protosun, the existence of a natural transport mechanism via bipolar outflows, and a general astrophysical plausibility, we were attracted to the fluctuating X-wind model which had been put forward by Frank Shu, Typhoon Lee, and colleagues. With our collaborators, we undertook a series of investigations to test the viability of this hypothesis; this work led directly to the discovery of live Be in CAIs and a clear demonstration of the existence of 160-rich condensates, which necessarily implies an O-16-rich gaseous reservoir in the nebula. Both of these observations fit well within the context of X-wind type models, i.e. formation of CAIs (or condensation of their precursors) in the reconnection ring sunward of the inner edge of the accretion disk, however much work remains to be done to test whether the physical parameters of the model can quantitatively predict not only the thermal histories of CAIs but also their radioactivity. The issue of spatial heterogeneity in the nebula, central to the X-wind model, is also at the heart of any chronology based on short-lived radioisotopes. In this work, we followed up on strong hints for presence of exireme:j: (53 day) short-lived Be-7, and have prepared a manuscript (in revision). We also measured A1-Mg systematics by a combined approach of high-precision multiple-collector SIMS analyses, traditional analyses on the UCLA ims 1270, and high-spatial resolution analyses using a NanoSIMS instrument. The data help to deconvolve effects due to partial resetting of the A1-Mg system by multiple thermal events. Finally, we initiated investigations related to nebular heterogeneity with a new initiative of in situ high-precision sulfur isotope analyses of sulfides from a wide variety of components of chondrites. The ultimate goal of all this work is to help develop a better understanding of the relationships between CAIs and chondrules, the astrophysical environments in which they formed, and the timescales of nebular processes. As detailed in Table 1, for the project period, 14 manuscripts were published and 17 abstracts were presented describing the work.

McKeegan, Kevin D.↗

Mars Geochemical Instrument (MarGI): An instrument for the analysis of the Martian surface and the search for evidence of life

The Mars Geochemical Instrument, MarGI, was developed to provide a comprehensive analysis of the rocks and surface material on Mars. The instrument combines Differential Thermal Analysis (DTA) with miniature Gas Chromatography-Ion Mobility Spectrometry (GC-IMS) to identify minerals, the presence and state of water, and organic compounds. Miniature pyrolysis ovens are used to both, conduct DTA analysis of soil or crushed rocks samples, and pyrolyze the samples at temperatures up to 1000 degrees C for GC-IMS analysis of the released gases. This combination of analytical processes and techniques, which can characterize the mineralogy of the rocks and soil, and identify and quantify volatiles released during pyrolysis, has applications across a wide range of target sites including comets, planets, asteroids, and moons such as Titan and Europa. The MarGI analytical approach evolved from the Cometary Ice and Dust Experiment (CIDEX) selected to fly on the Comet Rendezvous Asteroid Flyby Mission (CRAF).

Kojiro, Daniel R.↗

Paramagnetic Attraction of Impurity-Helium Solids

Impurity-helium solids are formed when a mixture of impurity and helium gases enters a volume of superfluid helium. Typical choices of impurity gas are hydrogen deuteride, deuterium, nitrogen, neon and argon, or a mixture of these. These solids consist of individual impurity atoms and molecules as well as clusters of impurity atoms and molecules covered with layers of solidified helium. The clusters have an imperfect crystalline structure and diameters ranging up to 90 angstroms, depending somewhat on the choice of impurity. Immediately following formation the clusters aggregate into loosely connected porous solids that are submerged in and completely permeated by the liquid helium. Im-He solids are extremely effective at stabilizing high concentrations of free radicals, which can be introduced by applying a high power RF dis- charge to the impurity gas mixture just before it strikes the super fluid helium. Average concentrations of 10(exp 19) nitrogen atoms/cc and 5 x 10(exp 18) deuterium atoms/cc can be achieved this way. It shows a typical sample formed from a mixture of atomic and molecular hydrogen and deuterium. It shows typical sample formed from atomic and molecular nitrogen. Much of the stability of Im-He solids is attributed to their very large surface area to volume ratio and their permeation by super fluid helium. Heat resulting from a chance meeting and recombination of free radicals is quickly dissipated by the super fluid helium instead of thermally promoting the diffusion of other nearby free radicals.

Bernard, E. P.↗

Modeling and Simulation Verification, Validation and Accreditation (VV&A): A New Undertaking for the Exploration Systems Mission Directorate

and Accreditation (VV&A) session audience, a snapshot review of the Exploration Space Mission Directorate s (ESMD) investigation into implementation of a modeling and simulation (M&S) VV&A program. The presentation provides some legacy ESMD reference material, including information on the then-current organizational structure, and M&S (Simulation Based Acquisition (SBA)) focus contained therein, to provide a context for the proposed M&S VV&A approach. This reference material briefly highlights the SBA goals and objectives, and outlines FY05 M&S development and implementation consistent with the Subjective Assessment, Constructive Assessment, Operator-in-the-Loop Assessment, Hardware-in-the-Loop Assessment, and In Service Operations Assessment M&S construct, the NASA Exploration Information Ontology Model (NExIOM) data model, and integration with the Windchill-based Integrated Collaborative Environment (ICE). The presentation then addresses the ESMD team s initial conclusions regarding an M&S VV&A program, summarizes the general VV&A implementation approach anticipated, and outlines some of the recognized VV&A program challenges, all within a broader context of the overarching Integrated Modeling and Simulation (IM&S) environment at both the ESMD and Agency (NASA) levels. The presentation concludes with a status on the current M&S organization s progress to date relative to the recommended IM&S implementation activity. The overall presentation was focused to provide, for the Verification, Validation,

Prill, Mark E.↗

Titan Ion Composition at Magnetosphere-Ionosphere Transition Region

Using Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS) ion composition data, we will investigate the compositional changes at the transition region between Saturn's magnetospheric flow and Titan's upper ionosphere. It is this region where scavenging of Titan's upper ionosphere can occur, where it is then dragged away by the magnetospheric flow as cold plasma for Saturn's magnetosphere. This cold plasma may form plumes as originally proposed by (1) during the Voyager 1 epoch. This source of cold plasma may have a unique compositional signature such as methane group ions. Water group ions that are observed in Saturn's outer magnetosphere (2,3) are relatively hot and probably come from the inner magnetosphere where they are born from fast neutrals escaping Enceladus (4) and picked up in the outer magnetosphere as hot plasma (5). This scenario will be complicated by pickup methane ions within Titan's mass loading region, as originally predicted by (6) based on Voyager 1 data and observationally confirmed by (3,7) using CAPS IMS data. But, CH4(+) ions or their fragments can only be produced as pickup ions from Titan's exosphere which can extend beyond the transition region of concern here, while CH5(+) ions can be scavenged from Titan's ionosphere. We will investigate these possibilities.

Sittler, Edward C.↗

Proton-transfer-reaction/ion-mobility-spectrometer and method of using the same

A high-pressure hollow cathode ionizer is combined with an ion-mobility-spectrometer (IMS) for the detection of trace amounts of organic compounds in gas. The ionizer uses H.sub.3 0.sup.+, ions which do not react with air to ionize the organic compounds and the organic compounds are soft ionized. The ionized organic compounds are detected in the IMS at levels of parts per billion and identified using calibrated reference tables. Applications include but are not limited to the fields of: (1) medicine as a breath analyzer for detection of lung cancer, diabetes, liver cirrhosis, (2) law enforcement in drug interdiction and explosives detection, (3) food monitoring and control, (4) environmental monitoring and (5) space applications.

Kanik, Isik↗

Cassini Observations of Saturn's Dawn-Magnetotail Region: Preliminary Results

Using Cassini thermal plasma, hot plasma and magnetic field observations for several intervals between the dawn meridian of Saturn's outer magnetosphere and Saturn's magnetotail region, we investigate the structure of the magnetotail, plasma and magnetic field properties within tail-like current sheet regions and ion flows within the dawn to magnetotail regions. We use Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS) and Electron Plasma Spectrometer (ELS) observations and MIMI LEMMS ion and electron observations to characterize the plasma environment. LMS observations are used to measure plasma flow velocities from which one can infer rotation versus convective flows. IMS composition measurements are used to trace the, source of plasma from the inner magnetosphere (protons, H(2+) and water group ions) versus an external solar wind source (protons and He++ ions). A critical parameter for both models is the strength of the convection electric field with respect to the rotational electric field for the large scale magnetosphere. For example, are there significant return flows (i.e., negative radial velocities, V(sub R) < 0) and/or plasmoids (V(sub R) > 0) within the magnetotail region?

Sittler, Edward C.↗

Utilizing Ion-Mobility Data to Estimate Molecular Masses

A method is being developed for utilizing readings of an ion-mobility spectrometer (IMS) to estimate molecular masses of ions that have passed through the spectrometer. The method involves the use of (1) some feature-based descriptors of structures of molecules of interest and (2) reduced ion mobilities calculated from IMS readings as inputs to (3) a neural network. This development is part of a larger effort to enable the use of IMSs as relatively inexpensive, robust, lightweight instruments to identify, via molecular masses, individual compounds or groups of compounds (especially organic compounds) that may be present in specific environments or samples. Potential applications include detection of organic molecules as signs of life on remote planets, modeling and detection of biochemicals of interest in the pharmaceutical and agricultural industries, and detection of chemical and biological hazards in industrial, homeland-security, and industrial settings.

Duong, Tuan↗

Saturn's Magnetosphere and Properties of Upstream Flow at Titan: Preliminary Results

Using Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS) measurements, we present the ion fluid properties and its ion composition of the upstream flow for Titan's interaction with Saturn's magnetosphere. A 3D ion moments algorithm is used which is essentially model independent with only requirement is that ion flow is within the CAPS IMS 2(pi) steradian field-of-view (FOV) and that the ion 'velocity distribution function (VDF) be gyrotropic. These results cover the period from TA flyby (2004 day 300) to T22 flyby (2006 363). Cassini's in situ measurements of Saturn's magnetic field show it is stretched out into a magnetodisc configuration for Saturn Local Times (SLT) centered about midnight local time. Under those circumstances the field is confined near the equatorial plane with Titan either above or below the magnetosphere current sheet. Similar to Jupiter's outer magnetosphere where a magnetodisc configuration applies, one expects the heavy ions within Saturn's outer magnetosphere to be confined within a few degrees of the current sheet while at higher magnetic latitudes protons should dominate. We show that when Cassini is between dusk-midnight-dawn local time and spacecraft is not within the current sheet that light ions (H, 142) tend to dominate the ion composition for the upstream flow. If true, one may expect the interaction between Saturn's magnetosphere, locally devoid of heavy ions and Titan's upper atmosphere and exosphere to be significantly different from that for Voyager 1, TA and TB when heavy ions were present in the upstream flow. We also present observational evidence for Saturn's magnetosphere interaction with Titan's extended H and H2 corona which can extend approx. 1 Rs from Titan.

Sittler, E. C., Jr.↗

Anomaly Detection for Next-Generation Space Launch Ground Operations

NASA is developing new capabilities that will enable future human exploration missions while reducing mission risk and cost. The Fault Detection, Isolation, and Recovery (FDIR) project aims to demonstrate the utility of integrated vehicle health management (IVHM) tools in the domain of ground support equipment (GSE) to be used for the next generation launch vehicles. In addition to demonstrating the utility of IVHM tools for GSE, FDIR aims to mature promising tools for use on future missions and document the level of effort - and hence cost - required to implement an application with each selected tool. One of the FDIR capabilities is anomaly detection, i.e., detecting off-nominal behavior. The tool we selected for this task uses a data-driven approach. Unlike rule-based and model-based systems that require manual extraction of system knowledge, data-driven systems take a radically different approach to reasoning. At the basic level, they start with data that represent nominal functioning of the system and automatically learn expected system behavior. The behavior is encoded in a knowledge base that represents "in-family" system operations. During real-time system monitoring or during post-flight analysis, incoming data is compared to that nominal system operating behavior knowledge base; a distance representing deviation from nominal is computed, providing a measure of how far "out of family" current behavior is. We describe the selected tool for FDIR anomaly detection - Inductive Monitoring System (IMS), how it fits into the FDIR architecture, the operations concept for the GSE anomaly monitoring, and some preliminary results of applying IMS to a Space Shuttle GSE anomaly.

Spirkovska, Lilly↗

Hand-Held Devices Detect Explosives and Chemical Agents

Ion Applications Inc., of West Palm Beach, Florida, partnered with Ames Research Center through Small Business Innovation Research (SBIR) agreements to develop a miniature version ion mobility spectrometer (IMS). While NASA was interested in the instrument for detecting chemicals during exploration of distant planets, moons, and comets, the company has incorporated the technology into a commercial hand-held IMS device for use by the military and other public safety organizations. Capable of detecting and identifying molecules with part-per-billion sensitivity, the technology now provides soldiers with portable explosives and chemical warfare agent detection. The device is also being adapted for detecting drugs and is employed in industrial processes such as semiconductor manufacturing.

Source record↗

Energy-Efficient Systems Eliminate Icing Danger for UAVs

Ames Research Center engineer Leonard Haslim invented an anti-icing t echnology called an electroexpulsive separation system, which uses m echanical force to shatter potentially dangerous ice buildup on an ai rcraft surface. Temecula, California-based Ice Management Systems (no w known as IMS-ESS) licensed the technology from Ames and has discov ered a niche market for the lightweight, energy-efficient technology: unmanned aerial vehicles (UAVs). IMS-ESS systems now prevent damagi ng ice accumulation on military UAVs, allowing the vehicles to carry out crucial missions year round.

Source record↗

Fault Management Technology Maturation for NASA's Constellation Program

This slide presentation reviews the maturation of fault management technology in preparation for the Constellation Program. There is a review of the Space Shuttle Main Engine (SSME) and a discussion of a couple of incidents with the shuttle main engine and tanking that indicated the necessity for predictive maintenance. Included is a review of the planned Ares I-X Ground Diagnostic Prototype (GDP) and further information about detection and isolation of faults using Testability Engineering and Maintenance System (TEAMS). Another system that being readied for use that detects anomalies, the Inductive Monitoring System (IMS). The IMS automatically learns how the system behaves and alerts operations it the current behavior is anomalous. The comparison of STS-83 and STS-107 (i.e., the Columbia accident) is shown as an example of the anomaly detection capabilities.

Waterman, Robert D.↗

A Comparison of Satellite-Derived Snow Maps with a Focus on Ephemeral Snow in North Carolina

In this paper, we focus on the attributes and limitations of four commonly-used daily snowcover products with respect to their ability to map ephemeral snow in central and eastern North Carolina. We show that the Moderate-Resolution Imaging Spectroradiometer (MODIS) fractional snow-cover maps can delineate the snow-covered area very well through the use of a fully-automated algorithm, but suffer from the limitation that cloud cover precludes mapping some ephemeral snow. The semi-automated Interactive Multi-sensor Snow and ice mapping system (IMS) and Rutgers Global Snow Lab (GSL) snow maps are often able to capture ephemeral snow cover because ground-station data are employed to develop the snow maps, The Rutgers GSL maps are based on the IMS maps. Finally, the Advanced Microwave Scanning Radiometer for EOS (AMSR-E) provides some good detail of snow-water equivalent especially in deeper snow, but may miss ephemeral snow cover because it is often very thin or wet; the AMSR-E maps also suffer from coarse spatial resolution. We conclude that the southeastern United States represents a good test region for validating the ability of satellite snow-cover maps to capture ephemeral snow cover,

Hall, Dorothy K.↗

Ion Composition of Titan's Ionosphere Observed During T9 Magnetotail Crossing

In a recent paper, Sittler et al., (2010) presented new results on the T9 encounter by the Cassini spacecraft when it passed through Titan s induced magnetotail. Two crossings were observed, but the first crossing, event 1, is thought to be out flowing ionosphere plasma. T9 is ideal for CAPS IMS probing of the ionosphere, since the ion densities at the higher altitudes of the T9 flyby approx. 10,000 km, allows measurements to be made down to 1 eV without saturating its detectors. Sittler et al., (2010) reported possible detection of NH4+ ions, but favored the detection of CH5+ and C2H5+ ions. In this report we investigate both the medium mass resolution (straight through (ST)) and high mass resolution (linear electric field (LEF)) composition data from the Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS). We present a more in depth analysis of the composition data and make comparisons with ionospheric models including nitrogen chemistry such as that by Vuitton et al. (2007). The LEF data does not support NH4+ identification, but favors a CH5+ and C2H5+ identification, but also molecular ions C2N+ and CH2NH2+ are chemically allowed possibilities.

Sittler, Edward↗