A mini loop heat pipe suitable for Mars rovers

This paper describes the thermal design requirements, the thermal performance characteristics and the flight qualification program of a mini-LHP suitable for the Mars Rovers.

loop heat pipe Mars rover thermal control↗

Swift BAT Thermal Recovery After Loop Heat Pipe #0 Secondary Heater Controller Failure in October 2015

The Swift BAT LHP #0 primary heater controller failed on March 31, 2010. It has been disabled. On October 31, 2015, the secondary heater controller of this LHP failed. On November 1, 2015, the LHP #0 CC temperature increased to as 18.6 C, despite that the secondary heater controller set point was 8.8 C. It caused the average DM XA1 temperature to increase to 25.9 C, which was 5 C warmer than nominal. As a result, the detectors became noisy. To solve this problem, the LHP #1 secondary heater controller set point was decreased in 0.5 C decrements to 2.2 C. The set-point decrease restored the average DM XA1 temperature to a nominal value of 19.7 C on November 21.

thermal recovery in orbit↗

Heat pipe thermal switch

A thermal switch for controlling the dissipation of heat between a body is described. The thermal switch is comprised of a flexible bellows defining an expansible vapor chamber for a working fluid located between an evaporation and condensation chamber. Inside the bellows is located a coiled retaining spring and four axial metal mesh wicks, two of which have their central portions located inside of the spring while the other two have their central portions located between the spring and the side wall of the bellows. The wicks are terminated and are attached to the inner surfaces of the outer end walls of evaporation and condensation chambers respectively located adjacent to the heat source and heat sink. The inner surfaces of the end walls furthermore include grooves to provide flow channels of the working fluid to and from the wick ends. The evaporation and condensation chambers are connected by turnbuckles and tension springs to provide a set point adjustment for setting the gap between an interface plate on the condensation chamber and the heat sink.

Wolf, D. A.↗

Feedback control of variable conductance heat pipes

Feedback system monitors source temperature and makes necessary changes of area available for heat rejection by adjusting storage volume of noncondensible gas and position of vapor/gas interface.

Bienert, W. B.↗

Rewetting of Monogroove Heat Pipe in Space Station Radiators

Experimental investigation of the rewetting characteristics of a uniformly heated grooved surface was performed, the results of which are presented in this work. It was found that, for a rewetting fluid of 2-propanol, the rewetting temperature was approx. 93-96 C for the upward-facing case and about 2 C lower for the downwardfacing case. When the initial plate temperature was higher than the rewetting temperature, the rewetting speed decreased with the initial plate temperature. The rewetting speed is also faster in the upward-facing case than in the downward-facing case for the same initial plate temperatures, which indicates a gravitational effect on rewetting. This trend is found to be consistent with the previously investigated end heating condition. The rewetting distance that is predicted by the conduction controlled model is found to be in fair agreement with the experimental data. Also, an apparatus that enables experiments to be performed in a reduced gravitational environment has been built and experiments are currently being performed. The design of this apparatus is presented along with preliminary data.

Chan, S. H.↗

Poisoning of Heat Pipes

Thermal management is critical to space exploration efforts. In particular, efficient transfer and control of heat flow is essential when operating high energy sources such as nuclear reactors. Thermal energy must be transferred to various energy conversion devices, and to radiators for safe and efficient rejection of excess thermal energy. Applications for space power demand exceptionally long periods of time with equipment that is accessible for limited maintenance only. Equally critical is the hostile and alien environment which includes high radiation from the reactor and from space (galactic) radiation. In space or lunar applications high vacuum is an issue, while in Martian operations the systems will encounter a CO2 atmosphere. The effect of contact at high temperature with local soil (regolith) in surface operations on the moon or other terrestrial bodies (Mars, asteroids) must be considered.

Gillies, Donald↗

Physics of heat pipe rewetting

Although several studies have been made to determine the rewetting characteristics of liquid films on heated rods, tubes, and flat plates, no solutions are yet available to describe the rewetting process of a hot plate subjected to a uniform heating. A model is presented to analyze the rewetting process of such plates with and without grooves. Approximate analytical solutions are presented for the prediction of the rewetting velocity and the transient temperature profiles of the plates. It is shown that the present rewetting velocity solution reduces correctly to the existing solution for the rewetting of an initially hot isothermal plate without heating from beneath the plate. Numerical solutions have also been obtained to validate the analytical solutions.

Chan, S. H.↗

Heat pipe controls bearing temperature

Major design problem in integrated Power/Attitude Control System (IPACS) is effective method for transporting heat from bearing inner race of the rotating assembly to minimize inner-race temperatures and temperature differential across bearing. High-speed rotating assembly in this application is essentially device for storing energy in electrically-driven rotating flywheel.

Cormack, A., III↗

Thermal analyses of a materials processing furnace being developed for use with heat pipes

A special materials processing furnace is being developed for the forthcoming Spacelab missions to study the solidification under closely controlled conditions of various sample materials in the absence of gravity. The samples are to be rod shaped and subjected to both heating and cooling simultaneously. The thermal model is based on a developed Thermal Analyzer computer program. The model was developed to be very general to enable the simulation of variations in the furnace design and, hence, serve as an aid in finalizing the design. The thermal model is described and a user's guide given. Some preliminary results obtained in testing the model are also given.

Mcanally, J. V.↗

Transient analysis of a capillary pumped loop heat pipe

A bench-top Capillary Pumped Loop (CPL) test system has been developed and tested to investigate the transient mode operation of this system by applying a step power input to the evaporators. Tests were conducted at several power input and evaporator inlet subcooling combinations. In addition, a lumped-heat-capacity model of the CPL test system has been presented which is used for predicting qualitatively the transient operation characteristics. Good agreement has been obtained between the predicted and the measured temperature variations. A simple evaporator inlet subcooler model has also been developed to study effects of inlet subcooling on the steady-state evaporator wall temperature. Results were compared with the test data collected.

Kiper, A. M.↗

Testing of a Miniature Loop Heat Pipe Using a Thermal Electrical Cooler for Temperature Control

This paper describes the design and testing of a miniature LHP having a 7 mm O.D. evaporator with an integral CC. The vapor line and liquid line are made of 1.6mm stainless steel tubing. The evaporator and the CC are connected on the outer surface by a copper strap and a thermoelectric (TEC) is installed on the strap. The TEC is used to control the CC temperature by applying an electrical current for heating or cooling. Tests performed in ambient included start-up, power cycle, sink temperature cycle, and CC temperature control using TEC. The LHP demonstrated very robust operation in all tests where the heat load varied between 0.5W and 1OOW, and the sink temperature varied between 243K and 293K. The heat leak from the evaporator to the CC was extremely small. The TEC was able to control the CC temperature within +/-0.3K under all test conditions, and the required control heater power was less than 1W.

Ku, Jentung↗