Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HELICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Nucleon momentum fraction, helicity and transversity from 2+1-flavor lattice QCD

A detailed analysis of the systematic uncertainties in the calculation of the isovector momentum fraction, ( x ) u - d , helicity moment, ( x ) Δ u - Δ d , and the transversity moment, ( x ) δu - δd , of the nucleon is presented using high-statistics data on seven ensembles of gauge configurations generated by the JLab/W&M/LANL/MIT collaborations using 2 + 1-flavors of dynamical Wilson-clover quarks. The much higher statistics have facilitated better control over all systematics compared to previous lattice calculations. The least understood systematic — excited-state contamination — is quantified by studying the variation of the results as a function of different estimates of the mass gap of the first excited state, obtained from two- and three-point correlation functions, and as a function of the pion mass M π . The final results are obtained using a simultaneous fit in the lattice spacing a , pion mass M π and the finite volume parameter M π L keeping leading order corrections. The data show no significant dependence on the lattice spacing and some evidence for finite-volume corrections. Our final results, in the $ \overline{\mathrm{MS}} $ scheme at 2 GeV, are ( x ) u - d = 0 . 155(17)(20), ( x ) Δ u - Δ d = 0 . 183(14)(20) and ( x ) δu - δd = 0 . 220(18)(20), where the first error is the overall analysis uncertainty assuming excited-state contributions have been removed, and the second is an additional systematic uncertainty due to possible residual excited-state contributions. These results are consistent with phenomenological global fit values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

All-helicity symbol alphabets from unwound amplituhedra

Here we review an algorithm for determining the branch points of general amplitudes in planar N = 4 super-Yang-Mills theory from amplituhedra. We demonstrate how to use the recent reformulation of amplituhedra in terms of ‘sign flips’ in order to streamline the application of this algorithm to amplitudes of any helicity. In this way we recover the known branch points of all one-loop amplitudes, and we find an ‘emergent positivity’ on boundaries of amplituhedra.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Helicity amplitude analysis of χcJ → ϕϕ

Using (447.9 ± 2.3) million ψ(3686) events collected with the BESIII detector, the decays of χcJ → ΦΦ (J = 0, 1, 2) have been studied via the decay ψ(3686) → γχcJ. The branching fractions of the decays χcJ → ΦΦ (J = 0, 1, 2) are determined to be (8.59 ± 0.27 ± 0.20) × 10-4, (4.26 ± 0.13 ± 0.15) × 10-4, and (12.67 ± 0.28 ± 0.33) × 10-4, respectively, which are the most precise measurements to date. From a helicity amplitude analysis of the process ψ(3686) → γχcJ , χcJ → ΦΦ, Φ → K+K-, the polarization parameters of the χcJ → ΦΦ decays are determined for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Split-helicity tree amplitudes and flag cluster algebras

Recent work has uncovered a connection between the symbol letters of general massless scattering and (permutations of) cluster variables of partial flag varieties. In this paper we explore the cluster adjacency of tree-level gluon amplitudes, specifically focusing on split-helicity amplitudes which can be written in closed form in terms of zigzag diagrams. We check in several cases, and conjecture in general, that the poles in each term satisfy cluster adjacency under a set of permutations that is built from arc permutations of the corresponding zigzag.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dispersion relations for γ*γ* → ππ: helicity amplitudes, subtractions, and anomalous thresholds

We present a comprehensive analysis of the dispersion relations for the doubly-virtual process γ * γ * → ππ . Starting from the Bardeen-Tung-Tarrach amplitudes, we first derive the kernel functions that define the system of Roy-Steiner equations for the partial-wave helicity amplitudes. We then formulate the solution of these partial-wave dispersion relations in terms of Omnès functions, with special attention paid to the role of subtraction constants as critical for the application to hadronic light-by-light scattering. In particular, we explain for the first time why for some amplitudes the standard Muskhelishvili-Omnès solution applies, while for others a modified approach based on their left-hand cut is required unless subtractions are introduced. In the doubly-virtual case, the analytic structure of the vector-resonance partial waves then gives rise to anomalous thresholds, even for space-like virtualities. We develop a strategy to account for these effects in the numerical solution, illustrated in terms of the D -waves in γ * γ * → ππ , which allows us to predict the doubly-virtual responses of the f 2 (1270) resonance. In general, our results form the basis for the incorporation of two-meson intermediate states into hadronic light-by-light scattering beyond the S -wave contribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Baryogenesis from decaying magnetic helicity in axiogenesis

Generating axion dark matter through the kinetic misalignment mechanism implies the generation of large asymmetries for Standard Model fermions in the early universe. Even if these asymmetries are washed out at later times, they can trigger a chiral plasma instability in the early universe. Similarly, a direct coupling of the axion with the hypercharge gauge field can trigger a tachyonic instability. These instabilities produce helical magnetic fields, which are preserved until the electroweak phase transition. At the electroweak phase transition, these become a source of baryon asymmetry, which can be much more efficient than the original axiogenesis proposal. We discuss constraints on axion dark matter production from the overproduction of the baryon asymmetry as well as a minimal, albeit fine-tuned setup, where both the correct dark matter abundance and baryon asymmetry can be achieved. For a given axion decay constant, this leads to a sharp prediction for the mass of the radial direction of the Peccei Quinn field, which is a soft mass scale in supersymmetric theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A complete basis of helicity operators for subleading factorization

Factorization theorems underly our ability to make predictions for many processes involving the strong interaction. Although typically formulated at leading power, the study of factorization at subleading power is of interest both for improving the precision of calculations, as well as for understanding the all orders structure of QCD. We use the SCET helicity operator formalism to construct a complete power suppressed basis of hard scattering operators for e + e - → dijets, e - p → e - jet, and constrained Drell-Yan, including the first two subleading orders in the amplitude level power expansion. We analyze the field content of the jet and soft function contributions to the power suppressed cross section for e + e - → dijet event shapes, and give results for the lowest order matching to the contributing operators. These results will be useful for studies of power corrections both in fixed order and resummed perturbation theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Helical-Tip Needle for Transthoracic Percutaneous Image-Guided Biopsy of Lung Tumors: Results of a Pilot Prospective Comparative Study with a Standard Tru-Cut Needle

PurposeTo prospectively evaluate feasibility and diagnostic performance of the 14-gauge helical-tip (Spirotome™, Cook{sup ®} Medical, Bloomington, USA) needle in transthoracic needle biopsy (TTNB) of lung lesions, compared to a conventional 18-gauge Tru-Cut needle.Materials and MethodsStudy was institutional review board approved, with informed consent obtained. Data from synchronous Spirotome and Tru-Cut image-guided TTNB of 20 consecutive patients with malignant peripheral lung tumors larger than 3 cm were enrolled for pathologic characterization and mutational analysis. Samples obtained with Spirotome and Tru-Cut needle were compared for fragmentation, length, weight, morphologic and immunohistochemistry typifying, tumor cellularity (TC) and DNA concentration.ResultsThe technical success rate for TTNB with Spirotome was 100%, and no major complications occurred. Less fragmentation (mean 2 vs. 3 fragments, P = .418), greater weight (mean 13 vs. 8.5 mg, P = .027) and lower length (mean 10.2 vs. 12.6 mm, P = .174) were observed with Spirotome compared to Tru-Cut needle. Accuracy of Spirotome and Tru-Cut needle in defining cancer histotype was similar (90%). Absolute and relative TC (mean 42 vs. 38, 124 vs. 108/10HPF), and DNA concentration (mean 49.6 vs. 39.0 ng/μl) were higher with Spirotome compared to Tru-Cut needle, with no statistical significance (P = .787 and P = .140, respectively).Conclusions Percutaneous 14-gauge Spirotome TTNB of selected lesions is feasible and accurate. It provides adequate samples for diagnosis, comparable to 18-gauge Tru-Cut needle, with a higher amount of tumor tissue (weight, TC, DNA concentration) even in shorter samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Turbulent flow and vortex characteristics in a blocked subchannel of a helically wrapped rod bundle

The study of flow and heat transfer through a bundle of rods is important, as this type of configuration is widely used in many engineering applications, for example, in heat exchangers, clusters of support structures, steam generators, and nuclear power reactors. This work experimentally investigated the flow-field characteristics of rod bundles with helically wrapped wires (wire-wrapped rod assemblies) proposed for advanced burner reactors. Subchannel blockage is one of the most interesting accident scenarios for liquid metal fast reactors as different mechanisms can lead to a partial or total subchannel blockage. It is of paramount important to understand the thermal-hydraulic behavior of the flow in the vicinity of such blockages. The flow mixing characteristics in two interior subchannels located near the core of the bundle, one without and one with the presence of a blockage, were experimentally investigated. The velocity fields within the spatial gaps of two subchannels were obtained by applying the matched-index-of-refraction and time-resolved particle image velocimetry (TR-PIV) technique for Reynolds numbers of 4000 and 17,000. The first- and second-order statistics, including the mean velocity, root-mean-square fluctuating velocity, and Reynolds stress, were computed from the obtained TR-PIV velocity vector fields. In the blocked sub-channel, the TR-PIV results revealed a large recirculation flow region in the vicinity of the blockage that was created by the interaction between inflows from neighboring subchannels. Spectral analysis was performed and the vortex shedding frequency indicated by the Strouhal number was found to be St = 0.16 for the two Reynolds numbers investigated. The flow characteristics of the interior subchannels were investigated via the two-point cross-correlation of fluctuating velocities. In addition, proper orthogonal decomposition (POD) analysis was applied to the instantaneous vorticity fields to extract the statistically dominant flow structures. Lastly, the statistical characteristics of the vortex, such as the vortex populations, spatial distributions, and vortex strengths, were acquired by combining POD analysis and the vortex identification algorithm.

42 ENGINEERING↗

Impurity Powder Injection Experiments in the Large Helical Device

The Impurity Powder Dropper (IPD) is a device capable of injecting controlled amounts of sub-millimetre powder into the plasma under the action of gravity. In 2019 the IPD was first installed on the Large Helical Device (LHD) in Japan, with the aim of improving the plasma performances through real time boronization and assessing the compatibility of this technique with steady state operation. Extensive series of experiments have been performed using the IPD, focused on the improvement of the plasma performance via low-Z powder injection and the understanding of the underlying physical phenomena. In this article, we review the experiments that took place in the period 2019-2024. The main results include the demonstration of the improvement of the wall conditions (reduction of intrinsic impurity content, wall recycling) both on a shot-to-shot basis and in real time. Furthermore, a reduced-turbulence improved confinement regime has been observed coincident with powder injection, resulting in an increase of the plasma temperature of the order of 25%, with enhancements that can reach up to 50% for ion temperature.

Nespoli, F. [Princeton Plasma Physics Laboratory (↗

The creation of the artificial RING finger from the cross-brace zinc finger by {alpha}-helical region substitution

The creation of the artificial RING finger as ubiquitin-ligating enzyme (E3) has been demonstrated. In this study, by the {alpha}-helical region substitution between the EL5 RING finger and the Williams-Beuren syndrome transcription factor (WSTF) PHD finger, the artificial E3 (WSTF PHD{sub R}ING finger) was newly created. The experiments of the chemical modification of residues Cys and the circular dichroism spectra revealed that the WSTF PHD{sub R}ING finger binds two zinc atoms and adopts the zinc-dependent ordered-structure. In the substrate-independent ubiquitination assay, the WSTF PHD{sub R}ING finger functions as E3 and was poly- or mono-ubiquitinated. The present strategy is very simple and convenient, and consequently it might be widely applicable to the creation of various artificial E3 RING fingers with the specific ubiquitin-conjugating enzyme (E2)-binding capability.

60 APPLIED LIFE SCIENCES↗

Cell-selectivity of tryptophan and tyrosine in amphiphilic α-helical antimicrobial peptides against drug-resistant bacteria

Highlights: • Novel peptides showed antibacterial activity in dose- and length-dependent manner. • All peptides showed membranolytic action, although mechanistic details may differ. • Most peptides were non-toxic to mammalian cells. • Presence of Trp and Tyr increased cell-specificity and antibacterial activity. The increasing emergence of drug-resistant bacteria creates a requirement for new antibiotics and various types of antibiotic materials such as proteins, peptides, polymers, and chemical compounds. Among these, antimicrobial peptides (AMPs) are considered to be promising antibiotic candidates for clinical treatments. In this study, we have designed a novel series of peptides with repeated sequences of minimum membrane-active motif, ‘XWZX’ basic sequence (X: lysine or arginine, Z: leucine, tyrosine, valine, or glycine), and an α-helical secondary structure. Some peptides displayed a potent antibacterial activity via membranolytic action and high therapeutic index (toxic dose/minimum inhibitory concentration) in vitro. Furthermore, in vivo experiments using bacterial ear-skin infection models verified that these peptides have the potential to be powerful and safe antibiotics. The present study provides a lead sequence for designing peptide antibiotics against bacterial membranes and information for cell-selectivity of hydrophobic amino acids with aromatic side chains such as Trp and Tyr.

60 APPLIED LIFE SCIENCES↗

Experimental study of mixed convection heat transfer in vertical helically coiled tube heat exchangers

In this study the mixed convection heat transfer in a coil-in-shell heat exchanger for various Reynolds numbers, various tube-to-coil diameter ratios and different dimensionless coil pitch was experimentally investigated. The experiments were conducted for both laminar and turbulent flow inside coil. Effects of coil pitch and tube diameters on shell-side heat transfer coefficient of the heat exchanger were studied. Different characteristic lengths were used in various Nusselt number calculations to determine which length best fits the data and several equations were proposed. The particular difference in this study in comparison with the other similar studies was the boundary conditions for the helical coils. The results indicate that the equivalent diameter of shell is the best characteristic length. (author)

14 SOLAR ENERGY↗

Spatial profiling of stapled α–helical peptide ATSP-7041 in mouse whole-body thin tissue sections using droplet-based liquid microjunction surface sampling-HPLC-ESI–MS/MS

Here, the application of a fully automated autosampler/HPLC-ESI–MS/MS system for spatially resolved quantitative droplet-based liquid extraction surface sampling/profiling of stapled α–helical peptide ATSP-7041 in mouse whole-body thin tissue sections is reported. 20-μm-thick serial tissue sections of an ATSP-7041 dosed mouse were prepared and the absolute concentration of the targeted peptide was first determined in different organs using 2.3-mm diameter tissue punches, standard bulk tissue extraction protocols, and subsequent HPLC separation and tandem mass spectrometric analysis. The same organs/locations were then analyzed in neighboring tissue sections using the droplet-based surface sampling approach. The observed ATSP-7041 concentration using this method was always significantly lower than that measured by the tissue punch workflow at the same tissue location of a serial section. Calculated extraction efficiencies were 10.7 ± 0.5% (brain), 11.0 ± 3.2% (liver spot 1), 10.7 ± 2.6% (liver spot 2), 15.0 ± 0.6% (lung) and 12.9 ± 0.7% (blood). While these extraction efficiency values were low, they were reproducible within a given organ. This suggests that once the extraction efficiency is established for a given tissue type and drug, the reproducibility of the droplet-based approach could provide a non-labor intensive and high-throughput means to acquire spatially resolved quantitative analysis of multiple samples of the same type.

60 APPLIED LIFE SCIENCES↗

Aichi Cancer Center Initial Experience of Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer Using Helical Tomotherapy

Purpose: To assess the feasibility of helical tomotherapy (HT) for patients with nasopharyngeal carcinoma. Methods and Materials: From June 2006 to June 2007, 20 patients with nasopharyngeal carcinoma were treated with HT with (n = 18) or without (n = 2) systemic chemotherapy. The primary tumor and involved lymph node (PTV1) were prescribed 70 Gy and the prophylactic region 54 Gy at D95, respectively. The majority of patients received 2 Gy per fraction for PTV1 in 35 fractions. Parotid function was evaluated using quantitative scintigraphy at pretreatment, and posttreatment at 3 months and 1 year later. Results: The median patient age was 53 years, ranging from 15 to 83. Our cohort included 5, 8, 4, 2, and 1 patients with disease Stages IIB, III, IVA, IVB, and IVC, respectively. Histopathological record revealed two for World Health Organization Type I and 18 for Type 2 or 3. The median duration time for treatment preparation was 9.5 days, and all plans were thought to be acceptable regarding dose constraints of both the planning target volume and organ at risk. All patients completed their treatment procedure of intensity-modulated radiation therapy (IMRT). All patients achieved clinical remission after IMRT. The majority of patients had Grade 3 or higher toxicity of skin, mucosa, and neutropenia. At the median follow-up of 10.9 months, two patients recurred, and one patient died from cardiac disease. Parotid gland function at 1 year after completion of IMRT was significantly improved compared with that at 3 months. Conclusion: HT was clinically effective in terms of IMRT planning and utility for patients with nasopharyngeal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4D-Imaging of the Lung: Reproducibility of Lesion Size and Displacement on Helical CT, MRI, and Cone Beam CT in a Ventilated Ex Vivo System

Purpose: Four-dimensional (4D) imaging is a key to motion-adapted radiotherapy of lung tumors. We evaluated in a ventilated ex vivo system how size and displacement of artificial pulmonary nodules are reproduced with helical 4D-CT, 4D-MRI, and linac-integrated cone beam CT (CBCT). Methods and Materials: Four porcine lungs with 18 agarose nodules (mean diameters 1.3-1.9 cm), were ventilated inside a chest phantom at 8/min and subject to 4D-CT (collimation 24 x 1.2 mm, pitch 0.1, slice/increment 24x10{sup 2}/1.5/0.8 mm, pitch 0.1, temporal resolution 0.5 s), 4D-MRI (echo-shared dynamic three-dimensional-flash; repetition/echo time 2.13/0.72 ms, voxel size 2.7 x 2.7 x 4.0 mm, temporal resolution 1.4 s) and linac-integrated 4D-CBCT (720 projections, 3-min rotation, temporal resolution {approx}1 s). Static CT without respiration served as control. Three observers recorded lesion size (RECIST-diameters x/y/z) and axial displacement. Interobserver- and interphase-variation coefficients (IO/IP VC) of measurements indicated reproducibility. Results: Mean x/y/z lesion diameters in cm were equal on static and dynamic CT (1.88/1.87; 1.30/1.39; 1.71/1.73; p > 0.05), but appeared larger on MRI and CBCT (2.06/1.95 [p < 0.05 vs. CT]; 1.47/1.28 [MRI vs. CT/CBCT p < 0.05]; 1.86/1.83 [CT vs. CBCT p < 0.05]). Interobserver-VC for lesion sizes were 2.54-4.47% (CT), 2.29-4.48% (4D-CT); 5.44-6.22% (MRI) and 4.86-6.97% (CBCT). Interphase-VC for lesion sizes ranged from 2.28% (4D-CT) to 10.0% (CBCT). Mean displacement in cm decreased from static CT (1.65) to 4D-CT (1.40), CBCT (1.23) and MRI (1.16). Conclusions: Lesion sizes are exactly reproduced with 4D-CT but overestimated on 4D-MRI and CBCT with a larger variability due to limited temporal and spatial resolution. All 4D-modalities underestimate lesion displacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effect of Prostate Motion During Helical Tomotherapy

Purpose: To assess the dosimetric consequence of intrafraction prostate motion on helical tomotherapy plans. Methods and Materials: An electromagnetic tracking device was used to measure real-time prostate motion for 515 fractions (16 patients). Motion tracks were used to retrospectively recalculate dose distributions using a four-dimensional calculation engine. The minimum dose (D{sub min}), maximum dose (D{sub max}), and dose to 95% of the volume (D{sub 95%}) were calculated for target volumes and compared with respective values from the treatment plan. The dosimetric effect was evaluated for each fraction. For each patient, the running cumulative effect was assessed throughout the course of treatment. Calculations were repeated assuming a time delay between initial patient setup and start of treatment. Results: Averaged over all fractions, the mean change in target D{sub 95%} was <1% (SD, 3-4%). Reductions in target D{sub 95%} of up to 20% were seen in individual fractions. Changes in prostate D{sub 95%} were similar in frequency and magnitude to D{sub 95%} changes in the planning target volume. The cumulative effect on target D{sub 95%} was approximately 1% (SD, 1%). The average cumulative effect after five fractions was 1% (SD, 1.5%). Conclusions: In general, the dosimetric effect of observed prostate motion on target D{sub 95%}was small. Infrequently severe D{sub 95%} degradations were observed for individual fractions, but their effect on the cumulative dose distribution was quickly reduced with minimal fractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Planning for Left-Sided Breast Cancer Patients With Positive Lymph Nodes: Comparison to Conventional Multiport Breast Technique

Purpose: To evaluate the feasibility of using helical tomotherapy for locally advanced left-sided breast cancer. Methods and Materials: Treatment plans were generated for 10 left-sided breast cancer patients with positive lymph nodes comparing a multiport breast (three-dimensional) technique with the tomotherapy treatment planning system. The planning target volumes, including the chest wall/breast, supraclavicular, axillary, and internal mammary lymph nodes, were contoured. The treatment plans were generated on the tomotherapy treatment planning system to deliver 50.4 Gy to the planning target volume. To spare the contralateral tissues, directional blocking was applied to the right breast and right lung. The optimization goals were to protect the lungs, heart, and right breast. Results: The tomotherapy plans increased the minimal dose to the planning target volume (minimal dose received by 99% of target volume = 46.2 {+-} 1.3 Gy vs. 27.9 {+-} 17.1 Gy) while improving the dose homogeneity (dose difference between the minimal dose received by 5% and 95% of the planning target volume = 7.5 {+-} 1.8 Gy vs. 37.5 {+-} 26.9 Gy). The mean percentage of the left lung volume receiving {>=}20 Gy in the tomotherapy plans decreased from 32.6% {+-} 4.1% to 17.6% {+-} 3.5%, while restricting the right-lung mean dose to <5 Gy. However, the mean percentage of volume receiving {>=}5 Gy for the total lung increased from 25.2% {+-} 4.2% for the three-dimensional technique to 46.9% {+-} 8.4% for the tomotherapy plan. The mean volume receiving {>=}35 Gy for the heart decreased from 5.6% {+-} 4.8% to 2.2% {+-} 1.5% in the tomotherapy plans. However, the mean heart dose for tomotherapy delivery increased from 7.5 {+-} 3.4 Gy to 12.2 {+-} 1.8 Gy. Conclusion: The tomotherapy plans provided better dose conformity and homogeneity than did the three-dimensional plans for treatment of left-sided breast tumors with regional lymph node involvement, while allowing greater sparing of the heart and left lung from doses associated with increased complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗