Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Critical parameters in the faculty application process: A data-driven analysis

We report the process of applying for science and engineering faculty positions requires a significant time investment for both the applicant and hiring committees. Applicants face the daunting task of sifting through a seemingly endless amount of information related to crafting their application packages in preparation for a review process that is inherently highly subjective. Furthermore, while scientific supervisors are often the most valuable resource during this stage of career development, many years may have passed since they went through this process themselves, and they may not have experience with recent developments in the application process. Because expectations and job responsibilities of new faculty members are rapidly evolving, certain guidelines are often not clearly specified, and it is therefore becoming difficult for applicants to most effectively prepare their application documents. Without access to adequate information and assistance, early-career researchers in particular can be placed at a significant disadvantage in the hiring process. Several recent articles can help prospective applicants in materials science and engineering land a faculty position,1,2,3 but there is nevertheless a need for clarification on expectations for different aspects of the faculty application materials.

36 MATERIALS SCIENCE↗

A Project Lifetime Approach to the Management of Induced Seismicity Risk at Geologic Carbon Storage Sites

The geologic storage of carbon dioxide (CO 2 ) is one method that can help reduce atmospheric CO 2 by sequestering it into the subsurface. Large-scale deployment of geologic carbon storage, however, may be accompanied by induced seismicity. We present a project lifetime approach to address the induced seismicity risk at these geologic storage sites. This approach encompasses both technical and nontechnical stakeholder issues related to induced seismicity and spans the time period from the initial consideration phase to postclosure. These recommendations are envisioned to serve as general guidelines, setting expectations for operators, regulators, and the public. They contain a set of seven actionable focus areas, the purpose of which are to deal proactively with induced seismicity issues. Although each geologic carbon storage site will be unique and will require a custom approach, these general best practice recommendations can be used as a starting point to any site-specific plan for how to systematically evaluate, communicate about, and mitigate induced seismicity at a particular reservoir.

58 GEOSCIENCES↗

Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018

Ground-based transient electromagnetic (TEM) data were acquired in selected locations around Belle Creek, Montana to define the resistivity structure of the near surface. Data were acquired using the ABEM WalkTEM system (Guideline Geo Ab, Sundbyberg, Sweden). TEM data were processed and numerically inverted to derive one-dimensional resistivity structure using SPIA (Aarhus Geosoftware, Aarhus, Denmark). This release includes raw and processed TEM data and resistivity models for each data location using the following structure: Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.xml SBC_TEM_2019_SoundingLocationsModels.gdb.zip - file geodatabase with all models and plots attached. This is a mirror of the contents of the model directory. Ground-based_transient_electromagnetic_data_and_resistivity_models_for_SubTER_BelleCreek_2017-2018.zip Data SBC_USF - raw data USF_format_description.pdf - manual describing the USF file format SBC_SoundingID-USF_lookup.csv - table describing the USF file naming convention and channel mapping *.usf files - raw, unprocessed data files SBC_TEM - processed data AarhusInv_manual.pdf - manual describing the TEM file format *.tem files - processed data files Models SBC_Model_Plots - plots of the data and the models for each sounding location TEM_model_data_dictionary.csv - data dictionary describing tabulated models SBC_TEM_models.csv - tabulated models

geophysical surveying↗

The Evaluation of Mechanical Properties of LB650 Cavities

The 650 MHz cavities have a stronger requirement of niobium mechanical properties because of the geometric shape of the cavity due to reduced beta. The mechanical property of the niobium half-cell was measured following various heat treatments. The 5-cell cavities were tested in a controlled drop test fashion and the real-world road test. The result showed that the 900C heat treatment was compatible with cavity handling and transportation during production. The test provides the bases of the transportation specification and shipping container design guidelines.

43 PARTICLE ACCELERATORS↗

Shape optimization and fluid control of near isothermal compressor for transcritical carbon dioxide cycle

The compressor holds great promise for enhanced energy efficiency over a wide range of vapor compression systems (VCS). However, the majority of them focused on liquid refrigerant injection or inter-stage cooling technologies to improve heat transfer. Increasing the heat transfer area provides another perspective to promote heat dissipation, which commonly involves shape optimization whilst bringing some limitations, mainly from the manufacturing side. To fill the research gap, this paper compares the performance of isothermal compressors under different compression chamber shapes and chamber connection configurations. Additionally, the fluid control of the liquid piston was combined with shape optimization to explore the potential for further heat transfer enhancement. The simulation results have demonstrated that the COP improvements can reach up to 9% compared with the baseline case by optimizing the chamber shape and properly controlling the liquid piston speed, which provides a guideline for designing and customizing the isothermal compression chamber.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-routine adjustments – towards standardizing M&V approach for quantifying the effects of static factors

The success of an energy management program relies on ensuring that the energy savings can be verified with an adequate level of certainty. Energy savings cannot be directly measured and hence have to be deduced by comparing the pre-retrofit energy consumption with post-retrofit energy consumption data adjusted to account for differences in conditions. These adjustments are needed, since conditions that influence energy consumption may not stay the same between pre- and postinstallation phase of the project. These adjustments can often be routine when accounting for factors like production volume and weather that are expected to change and are included in the energy consumption adjustment model. Existing measurement and verification (M&V) resources and guidance mostly concentrate on developing models for routine adjustment of one or more factors that normally change. On the other hand, there are factors (static) like product mix, operating hours, gross square area, etc. that are assumed to stay constant during normal conditions. However, in order to adapt to dynamic market conditions, the industries are forced to react thereby leading to changes to these static factors. Identifying these static factors that warrant adjustment, called non-routine event, along with quantifying their effect on energy consumption can be complex and lack of proper guidance can exacerbate this issue. This paper reviews some of the current work in terms of how non-routine events are defined, characterized, detected and quantified based on a review of existing M&V guidelines, protocols and other relevant literature. This work also reviewed some of the existing non-routine events and adjustment practices to understand how these different aspects are addressed along with a discussion on some of the key challenges and gaps in the current guidance.

Earni, Shankar↗

Enter the AHU (36th Chamber of ASHRAE): A Multi-site Field Study of ASHRAE G36

Despite being recognized as the best practice for advanced building controls, ASHRAE Guideline 36 (G36) has seen slow adoption in retrofit cases. Decisionmakers lack credible field evidence to justify the time and person-power investment. Most prior analyses have relied on software simulations, which overlook implementation challenges and fail to persuade owners to move from models to real-world deployment. This paper presents a multi-site field study of G36 performance, drawing on measured results from 17 projects across diverse building types and climate zones. The analysis disaggregates outcomes by the most widely adopted air handling unit (AHU) based G36 strategies, including trim-and-respond approaches to supply air temperature (SAT) and duct static pressure (DSP) reset, and economizer controls. Results for controls re programming implementations are encouraging, with HVAC savings ranging from 2% - 49%, with a median of 18%. The range aligns with simulation study findings showing 1% - 46% savings through these three strategies. These findings show that even without capital investment in control infrastructure upgrades, existing building owners are reaping significant benefits from updating HVAC sequences of operation to industry best-practice solutions. The results give practitioners and decisionmakers a reference point on what to expect, which strategies deliver, and how field performance may compare to simulation.

Deshpande, Reva↗

Re-Envisioning RCx: Achieving Max Potential HVAC Controls Retrofits through Modernized BAS Hardware and Software

Most existing buildings have sub-optimal heating, ventilation, and air conditioning (HVAC) controls, resulting in wasted energy and occupant discomfort. Retro-commissioning (RCx) addresses many of these issues, but it is a lengthy and highly customized process. Limited capabilities of existing building automation system hardware restricts the scope of most RCx projects. Incentive programs consider building automation system (BAS) hardware retrofits to be high-capital investments and do not allow them in typical RCx programs. This paper describes work that the authors are leading to facilitate technical and market innovation in the BAS industry to unlock large savings in existing commercial buildings through deep retrofits of BAS hardware and software. California and New York research projects are demonstrating BAS retrofits leveraging the American Society of Heating, Refrigeration, and Air Conditioning Engineers’ (ASHRAE) new Guideline 36 high performance sequences of operation to achieve greater than 20 percent whole building energy savings, while saving costs and reducing risk through streamlined processes and standardization across BAS manufacturer product lines and across implementation practices. This paper describes market barriers that impede achieving deep savings from BAS retrofits in custom incentive and traditional RCx programs and presents a new maximum potential BAS retrofit model that addresses these barriers. The new model leverages the authors’ efforts in market enablement through open standards, BAS industry partnerships, and tools for cost-effective scaling that includes tools for project screening, savings calculations, and measurement and verification (M&V). This approach is widely applicable and will be ready for at-scale implementation within two years.

Paliaga, Gwelen↗

Use of carbon electrodes to reduce mobile ion concentration and improve reliability of metal halide perovskite photovoltaics

Ion migration is one of the prime reasons for the rapid degradation of metal halide perovskite solar cells (PSCs), and we report on a method for quantifying mobile ion concentration (No) using a transient dark current measurement. We perform both ex-situ and in-situ measurements on PSCs and study the evolution of No in films and devices under a range of temperatures. We also study the effect of device architecture, top electrode chemistry, and metal halide perovskite composition and dimensionality on No. Two-dimensional perovskites are shown to reduce the ion concentration along with inert C electrodes that do not react with halides by ~99% while also improving mechanical reliability by ~250%. We believe this work can provide design guidelines for the development of stable PSCs through the lens of minimizing mobile ions and their evolution over time under operational conditions.

14 SOLAR ENERGY↗

Assessment of Lost Circulation Material Particle-Size Distribution on Fracture Sealing: A Numerical Study

Summary Lost circulation materials (LCMs) are essential to combat fluid loss while drilling and may put the whole operation at risk if a proper LCM design is not used. The focus of this research is understanding the function of LCMs in sealing fractures to reduce fluid loss. One important consideration in the success of fracture sealing is the particle-size distribution (PSD) of LCMs. Various studies have suggested different guidelines for obtaining the best size distribution of LCMs for effective fracture sealing based on limited laboratory experiments or field observations. Hence, there is a need for sophisticated numerical methods to improve the LCM design by providing some predictive capabilities. In this study, computational fluid dynamics (CFD) and discrete element methods (DEM) numerical simulations are coupled to investigate the influence of PSD of granular LCMs on fracture sealing. Dimensionless variables were introduced to compare cases with different PSDs. We validated the CFD-DEM model in reproducing specific laboratory observations of fracture-sealing experiments within the model boundary parameters. Our simulations suggested that a bimodally distributed blend would be the most effective design in comparison to other PSDs tested here.

Engineering↗

Analytical methods for online data quality assessment

This chapter provides a comprehensive overview of the main steps for algorithmic sensor signal quality assessment, which can enhance the decision-making process for water resource recovery facility (WRRF) operation and optimization. It introduces the concept of redundancy as the basis for data quality assessment. It also explains the typical data processing pipeline, which consists of preliminary analysis, data pre-processing, and specific algorithmic approaches. Each of these processes is presented and discussed in three separate sections. Importantly, this chapter introduces the main approaches for data quality assessment, provides guidelines for selecting the most suitable one and the key performance indicators to evaluate them and explains how to collect metadata through such an algorithmic approach.

Aguado, Daniel↗

Scan of an Unpublished Report: "Fission Product Behavior During Severe LWR Accidents: Recommendations for the MELCOR Code System"

This document provides a scanned version of a 1987 SAND report that was never formally published. However, this report was referenced within the MELCOR Reference Manual and, therefore, provides historical information and technical basis for the MELCOR code. This document is being made available to permit users of the MELCOR code access to the information. The title page has been edited to prevent any confusion with regards to the possible documentation identifiers, such as the SAND report number or the intended date of publication. Beyond these modifications, a cover, distribution, and back cover are prepended and appended to the document to conform to modern SAND report style guidelines. The first four chapters of this report were updated and released under the title "Fission Product Behavior During Severe LWR Accidents: Recommendations for the MELCOR Code System. Volume I" and were made available by the U.S. NRC through the Adams database under accession number ML19227A327. No prior release of the remaining content of this report has occurred.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Continuous Water Quality Sensing for FGD Wastewater

The coal fired plant power industry requires new solutions for on-line monitoring of flue gas desulfurization (FGD) wastewaters for regulated trace metals to reduce recurring operating and off-site laboratory analysis costs and provide a high level of confidence of compliance with state and federal discharge guidelines. The University of Alabama at Birmingham (UAB) developed an integrated water sensor package for continuous water quality monitoring of flue gas desulfurization (FGD) wastewaters for concentration measurements of Selenium (Se). UAB utilized a diverse team of University Professors/Staff Members/Student(s) (Engineering and Innovative Technology Development Group), a University Affiliated Research Institution from the local area (Southern Research), and a cost sharing Industry Partner (Metrohm). The team developed and validated a proprietary wet chemistry batch process for water sample preparation; and implemented this process as a fully automated on-line monitor prototype system. This prototype system’s performance was evaluated in both the laboratory and during in-field deployment to a coal fired power plant. In both environments it was found that the prototype system was unable to recreate the batch process’s success at preparing FGD water samples for total Se measurements with a commercial-off-the-shelf (COTS) cyclic anodic stripping voltammetry (CSV) system. Through this experience, UAB has provided insight into a number of specific areas where improvements can be made with respect to the COTS systems used in this project to yield a more complete and competitive industry solution for on-line monitoring of total Se in industrial wastewater.

01 COAL, LIGNITE, AND PEAT↗

Operationalizing Synchrophasors for Enhanced Grid Reliability and Asset Utilization

The report discusses the development of production-grade synchrophasor software applications. The objective is to improve system reliability and asset utilization for offline as well as real-time considerations, as per the Department of Energy (DOE) guidelines specified by Funding Opportunity Announcement (FOA) DE-FOA-0001492. On the one hand, we have developed grid management applications on how to transform synchrophasor-based monitoring into operator guidance, and commercial grade tools addressing industry needs such as NERC Reliability Standards (MOD 26, MOD 27 and MOD 33). On the other hand, with the wide industrial adoption in mind, the developed applications have been fully discussed with utility partners and installed in the utility partners site including 6 field tests. The Model Validation and Calibration software module has been integrated into GE’s PhasorAnalyticsTM. The first commercial contract has been signed even before the close date of this project. The Angle-based Grid Management (AGM), Fast Voltage Security Assessment (FastVSA), Enhanced Islanding Monitoring(EIM) and Enhanced Disturbance Management (EDM) have been integrated into GE’s Grid Stability Assessment line of applications in e-terra Suite of EMS product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RadResponder Nationwide Drill 2020: FRMAC participation After Action Report

On February 11th, 2020 FRMAC participated in the 2020 RadResponder nationwide drill involving survey data review and approval. During this drill, dozens of organizations from across the country participated in uploading simulated survey results to their own RadResponder event and reviewing those data given some "best-practice" guidelines. FRMAC participated in this drill to learn how this process is carried out in RadResponder and to determine some areas of improvement that will make FRMACs use of RadResponder more effective and efficient. As drill participants, the four FRMAC staff each set up their own RadResponder events so they could work independently to work through each step. Each were given an import file with 60 survey measurements to import and review. At the end of the drill a hotwash was held where users were able to ask questions and receive feedback from Chainbridge and FRMAC participants. In summary, several areas for improvement have been identified and will be categorized as items that need immediate attention (Bugs), areas for improvement in the near-term (change requests), and ideas on how the overall process can be improved (feature requests). The items presented in this report by no means reflect all the required changes FRMAC Monitoring and Sampling and Assessment will need to carry out their procedures in RadResponder but do represent a step in the right direction. A full review and exercise of the FRMAC process will need to be conducted with more subject matter experts to discover all the required features FRMAC needs to carry out their mission.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Multi-cell Failure Propagation

Failure propagation testing is of increasing interest to the designers and end users of battery systems. One of the chief difficulties, however, is choosing an appropriate initiation method to perform the test. Single cell abuse testing is typically used to initiate thermal runaway but this can involve a large amount of additional energy injected into the system. It is assumed that this will have some impact on the behavior of a propagating thermal runaway event, but there is little data available as to how significant this would be. Further, it is ultimately difficult to develop viable propagation tests for compliance and public safety activities without better knowledge of how test methods will impact the results. This work looks at propagating battery failure with a variety of chemistries, formats, configurations and initiation methods to determine the level of significance of the chosen initiation method on the test results. We have ultimately found while there is some impact on the detailed results of propagation testing, in most cases other factors, particularly the energy density of the system play a much greater role in the likelihood of a propagation event consuming an entire battery. We have also provided some guidelines for test design to support best practices in testing.

25 ENERGY STORAGE↗

Intensified Flue Gas Desulfurization Water Treatment for Reuse, Solidification, and Discharge

The goal of this final project report is to summarize the work conducted on project DE-FE0031555. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Center for Applied Energy Research (UK CAER) (Recipient) developed a hybrid electrochemical-membrane technology for treating wet flue gas desulfurization (WFGD) blowdown from coal-fired power generation plants that (1) removes government-regulated species and total suspended solids (TSS) via electrocoagulation with solid/liquid separation to avoid further treatments by a biological method specifically for selenium, and (2) reduces total dissolved solids (TDS) in a nanofiltration unit to promote water recycle and reduce freshwater intake. Additional technological configurations were pursued, including (1) nanofiltration combined with zeolite dewatering for a near-zero liquid discharge (ZLD) scenario, and (2) polishing discharge from zeolite dewatering using capacitive deionization (CDI) with 90+% salt rejection to produce water with less than 100ppm TDS for more beneficial use. Project results verified that UK CAER’s hybrid approach addressed the complexities of WFGD blowdown with simplified unit operation at relatively low capital investment by demonstrating: (1) an effective in-situ generated solid sorbent material, green-rust (GR), that specifically removes regulated dissolved species in WFGD blowdown, including selenium, arsenic, and nitrates; (2) a low-cost, high flux nanofiltration treatment that removes both monovalent and divalent species at >80% rejection to adequately provide water recycle and extend the life of FGD equipment by mitigating chloride aided pitting corrosion mechanisms; and (3) a solidification and stabilization process using pozzolanic agents that retain regulated species and satisfy the Resource Conservation and Recovery Act (RCRA) leachate requirements. UK CAER proved electrocoagulation with GR to be an intensified solution for effluent limit guidelines (ELG), and based on preliminary techno-economic analysis (TEA), in comparison to DOE’s Case 1 for Biological Wastewater Treatment that had a purchased equipment cost (PEC) of $\$$5.26 million and a Total plant cost (TPC) of $\$$30.0 million, the EC process had a PEC of $\$$2.67 million and the TPC of $\$$17.0 million. While the electricity consumption for Case 1 was 53 kW, it was 110 kW for the EC process due to dissolving iron for a three-stage reaction design. However, electricity consumption for the EC process could be significantly reduced by adopting a counter-current reactor design for at least a 6-stage chemical reaction operation.

01 COAL, LIGNITE, AND PEAT↗

Observations Regarding Commonly Available Materials for Face Shield Emulated-Personal Protective Equipment

The Center for Disease Control has recommended that to reduce potential exposure to COVID-19 the public should wear cloth face coverings in public settings where other social distancing measures are difficult to maintain. These face coverings and other Emulated-Personal Protective Equipment (E-PPE) can be made by using Commonly Available Materials (CAMs). As E-PPE recommendations continue to flood the media, a Sandia COVID-19 LDRD effort, the Sandia E-PiPEline Team, systematically evaluated E-PPE design options considering their effectiveness, durability, build difficulty, build cost, and comfort. Using qualitative and semi-quantitative evaluation tools, results of the investigation are presented here to provide guidelines for home and office construction of E-PPE.

36 MATERIALS SCIENCE↗