Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Germanium Enrichments in Sedimentary Rocks in Gale Crater, Mars: Constraining the Timing of Alteration and Character of the Protolith

Rocks enriched in Ge have been discovered in Gale Crater, Mars, by the Alpha-particle X-ray spectrometer (APXS) on the Mars Science Lab (MSL) rover, Curiosity. The Ge concentrations in Gale Crater (commonly >50 ppm) are remarkably high in comparison to Earth, where Ge ranges from 0.5-4.0 ppm in igneous rocks and 0.2-3.3 ppm in siliciclastic sediment. Primary meteoritic input is not likely the source of high Ge because Ge/Ni in chondrites (approx.0.003) and irons (<0.04) is lower than in Gale rocks (0.08-0.2). Earth studies show Ge is a useful geochemical tracer because it is coherent with Si during magmatic processes and Ge/Si varies less than 20% in basalts. Ge and Si fractionate during soil/regolith weathering, with Ge preferentially sequestered in clays. Ge is also concentrated in Cu- and Zn-rich hydrothermal sulfide deposits and Fe- and Mnrich oxide deposits. Other fluid-mobile elements (K, Zn, Cl, Br, S) are also enriched at Gale and further constrain aqueous alteration processes. Here, we interpret the sediment alteration history and present a possible model for Ge enrichments at Gale involving fluid alteration of the protolith.

Berger, J. A.↗

Alumina+Silica+/-Germanium Alteration in Smectite-Bearing Marathon Valley, Endeavour Crater Rim, Mars

Mars Exploration Rover Opportunity has been exploring Mars for 12+ years, and is presently investigating the geology of a western rim segment of 22 kilometers diameter, Noachian- aged Endeavour crater. The Alpha Particle X-ray Spectrometer has determined the compositions of a pre-impact lithology, the Matijevic fm., and polymict impact breccias ejected from the crater, the Shoemaker fm. Opportunity is now investigating a region named Marathon Valley that cuts southwest-northeast through the central portion of the rim segment and provides a window into the lower stratigraphic record. (Geographic names used here are informal.) At the head of Marathon Valley, referred to here as Upper Marathon Valley, is a shallow, ovoid depression approximately 25×35 millimeters in size, named Spirit of Saint Louis. Layering inside Spirit of Saint Louis appears continuous with the Upper Marathon Valley rocks outside, indicating they are coeval. Spirit of Saint Louis is partly bounded by approximately 10-20 centimeters wide zone containing reddish altered rocks (red zone). Red zones also form prominent curvilinear features in Marathon Valley. Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) spectra provide evidence for a really extensive Fe-Mg smectite in the Marathon Valley region, indicating distinct styles of aqueous alteration. The CRISM detections of smectites are based on metal-OH absorptions at approximately 2.3 and 2.4 micron that are at least two times the background noise level.

Mittlefehldt, D. W.↗

FOUR PI CALIBRATION AND MODELING OF A BARE GERMANIUM DETECTOR IN A CYLINDRICAL FIELD SOURCE

In reference 1 the authors described {gamma}-ray holdup assay of a Mossbauer spectroscopy instrument where they utilized two axial symmetric cylindrical shell acquisitions and two disk source acquisitions to determine Am-241 and Np-237 contamination. The measured contents of the two species were determined using a general detector efficiency calibration taken from a 12-inch point source.2 The authors corrected the raw spectra for container absorption as well as for geometry corrections to transform the calibration curve to the applicable axial symmetric cylindrical source - and disk source - of contamination. The authors derived the geometry corrections with exact calculus that are shown in equations (1) and (2) of our Experimental section. A cylindrical shell (oven source) acquisition configuration is described in reference 3, where the authors disclosed this configuration to gain improved sensitivity for holdup measure of U-235 in a ten-chamber oven. The oven was a piece of process equipment used in the Savannah River Plant M-Area Uranium Fuel Fabrication plant for which a U-235 holdup measurement was necessary for its decontamination and decommissioning in 2003.4 In reference 4 the authors calibrated a bare NaI detector for these U-235 holdup measurements. In references 5 and 6 the authors calibrated a bare HpGe detector in a cylindrical shell configuration for improved sensitivity measurements of U-235 in other M-Area process equipment. Sensitivity was vastly improved compared to a close field view of the sample, with detection efficiency of greater than 1% for the 185.7-keV {gamma}-ray from U-235. In none of references 3 - 7 did the authors resolve the exact calculus descriptions of the acquisition configurations. Only the empirical efficiency for detection of the 185.7-keV photon from U-235 decay was obtained. Not until the 2010 paper of reference 1 did the authors derive a good theoretical description of the flux of photons onto the front face of a detector from an axially symmetric cylindrical shell. Subsequent to publication of 1, the theoretical treatment of the cylindrical shell and disk source acquisition sources was recognized by the Los Alamos National Laboratory as suitable for including in the Safeguards Training Program.8 Therefore, we felt it was important to accurately demonstrate the calculus describing the cylindrical shell configuration for the HpGe detector and to theoretically account for the observed bare-detector efficiencies measured in references (3-6). In this paper we demonstrate the applicability of the cylindrical shell derivation to a flexible planar sheet of known Am-241, Eu-152, and Cs-137 activity that we rolled into a symmetrical cylindrical shell of radioactivity. Using the geometry correction equation of reference 1, we calculate geometry correction values using the known detector and source dimensions combined with source to detector distances. We then compare measured detection efficiencies from a cylindrical shell of activity for the 185.7-keV photon (U-235) and for the 414.3-keV photon (Pu-239) with those determined for a 12-inch point source(2,7) to demonstrate agreement between experiment and the theoretically calculated values derived by the Savannah River National Laboratory (SRNL) authors of reference 1. We demonstrate this geometry correction first for the 185.7- and 414.3-keV {gamma}-rays. But because the detector was point source calibrated at 12 inches for the energy range (60 -1700) keV (using two distinct sources) to map its intrinsic efficiency, the geometry correction for any acquisition configuration holds for all photon energies.2 We demonstrate that for ten photon energies in the range 121 keV to 967 keV. The good agreement between experiment and calculation is demonstrated at five source to detector distances using the identical shielded HpGe detector of references 4-7 as well as with a separate HpGe detector. We then extend the measurement to include a single acquisition where the flexible source is wrapped around the bare detector in a symmetrical cylinder that radiates on both faces of the detector as well as on to the detector's cylindrical sides of known dimensions. We derive the exact calculus to calculate the flux of the source on to the cylindrical sides of the detector. We then demonstrate outstanding agreement between the measured efficiency for the two primary U-235 and Pu-239 photons in this oven source configuration compared to the point source of activity for which the detector was originally calibrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗