At least 865 records · Page 48

Uncertainty and Intelligence in Computational Stochastic Mechanics

Classical structural reliability assessment techniques are based on precise and crisp (sharp) definitions of failure and non-failure (survival) of a structure in meeting a set of strength, function and serviceability criteria. These definitions are provided in the form of performance functions and limit state equations. Thus, the criteria provide a dichotomous definition of what real physical situations represent, in the form of abrupt change from structural survival to failure. However, based on observing the failure and survival of real structures according to the serviceability and strength criteria, the transition from a survival state to a failure state and from serviceability criteria to strength criteria are continuous and gradual rather than crisp and abrupt. That is, an entire spectrum of damage or failure levels (grades) is observed during the transition to total collapse. In the process, serviceability criteria are gradually violated with monotonically increasing level of violation, and progressively lead into the strength criteria violation. Classical structural reliability methods correctly and adequately include the ambiguity sources of uncertainty (physical randomness, statistical and modeling uncertainty) by varying amounts. However, they are unable to adequately incorporate the presence of a damage spectrum, and do not consider in their mathematical framework any sources of uncertainty of the vagueness type. Vagueness can be attributed to sources of fuzziness, unclearness, indistinctiveness, sharplessness and grayness; whereas ambiguity can be attributed to nonspecificity, one-to-many relations, variety, generality, diversity and divergence. Using the nomenclature of structural reliability, vagueness and ambiguity can be accounted for in the form of realistic delineation of structural damage based on subjective judgment of engineers. For situations that require decisions under uncertainty with cost/benefit objectives, the risk of failure should depend on the underlying level of damage and the uncertainties associated with its definition. A mathematical model for structural reliability assessment that includes both ambiguity and vagueness types of uncertainty was suggested to result in the likelihood of failure over a damage spectrum. The resulting structural reliability estimates properly represent the continuous transition from serviceability to strength limit states over the ultimate time exposure of the structure. In this section, a structural reliability assessment method based on a fuzzy definition of failure is suggested to meet these practical needs. A failure definition can be developed to indicate the relationship between failure level and structural response. In this fuzzy model, a subjective index is introduced to represent all levels of damage (or failure). This index can be interpreted as either a measure of failure level or a measure of a degree of belief in the occurrence of some performance condition (e.g., failure). The index allows expressing the transition state between complete survival and complete failure for some structural response based on subjective evaluation and judgment.

Ayyub, Bilal M.↗

Review of SiC material development for nuclear fusion applications: Cross-cutting research and emerging opportunities

The SiC-based materials, particularly SiC-fiber-reinforced SiC matrix (SiC/SiC) composites, show strong potential for structural and functional applications in future fusion power plants because they can operate at high temperatures with a range of coolants and breeders, thereby enabling higher energy conversion efficiency. Here, this paper presents recent advancements in the development of SiC-based materials, focusing on processing techniques and material performance and resistance under fusion-relevant environments. The processing activities have emphasized near-net-shape fabrication and the joining of SiC subcomponents, with processing methods and material compositions informed by previous irradiation experiments on various grades of SiC. Research on irradiation effects has remained focused on degradation mechanisms and the microstructural optimization of SiC/SiC composites irradiated to high neutron damage levels. Analysis of irradiation defects in SiC has advanced via the application of cutting-edge characterization methods, among which Raman spectroscopy is becoming a common tool to assess atomic-scale chemical disorder. Fusion–fission crosscutting irradiation research has explored combined effects in SiC/SiC composites with application-relevant geometries, including bowing of SiC/SiC composite channels under neutron flux gradients, stress evolution in SiC/SiC composite tubes under through-thickness temperature gradients, and irradiation-enhanced corrosion in SiC. Finally, research opportunities for component testing and assessment under fusion-relevant conditions, in support of emerging concepts from the private fusion sector, are discussed.

Advanced manufacturing↗

Separation of packaging plastics by froth flotation in a continuous pilot plant

The objective of the research was to apply froth flotation to separate post-consumer PET (Polyethylene Terephthalate) from other packaging plastics with similar density, in a continuously operated pilot plant. A representative sample composed of 85% PET, 2.5% PVC (Polyvinyl Chloride) and 11.9% PS (Polystyrene) was subjected to a combination of alkaline treatment and surfactant adsorption followed by froth flotation. A mineral processing pilot plant, owned by a Portuguese mining company, was adapted for this purpose. The experimentation showed that it is possible to produce an almost pure concentrate of PET, containing 83% of the PET in feed, in a single bank of mechanical flotation cells. The concentrate grade attained was 97.2% PET, 1.1% PVC and 1.1% PS. By simulation it was shown that the Portuguese recycling industry specifications can be attained if one cleaning and one scavenger stages are added to the circuit.

07 ISOTOPE AND RADIATION SOURCES↗

TLSLEAF: Automatic Leaf Angle Estimates From Single-Scan Terrestrial Laser Scanning

Leaf angle distribution (LAD) in forest canopies affects estimates of leaf area, light interception, and global-scale photosynthesis, but is often simplified to a single theoretical value. Here, we present TLSLeAF (Terrestrial Laser Scanning Leaf Angle Function), an automated open-source method of deriving LADs from terrestrial laser scanning. TLSLeAF produces canopy-scale leaf angle and LADs by relying on gridded laser scanning data. The approach increases processing speed, improves angle estimates, and requires minimal user input. Key features are automation, leaf–wood classification, beta parameter output, and implementation in R to increase accessibility for the ecology community. TLSLeAF precisely estimates leaf angle with minimal distance effects on angular estimates while rapidly producing LADs on a consumer-grade machine. We challenge the popular spherical LAD assumption, showing sensitivity to ecosystem type in plant area index and foliage profile estimates that translate to c. 25% and c. 11% increases in canopy net photosynthesis (c. 25%) and solar-induced chlorophyll fluorescence (c. 11%). TLSLeAF can now be applied to the vast catalog of laser scanning data already available from ecosystems around the globe. The ease of use will enable widespread adoption of the method outside of remote-sensing experts, allowing greater accessibility for addressing ecological hypotheses and large-scale ecosystem modeling efforts.

3D↗

Prediction for Pressure Differential Across HEPA Filter Media Based on Media Characteristics and Particle Size Distribution

A new method for predicting the pressure drop across High Efficiency Particulate Air (HEPA) filter media is proposed based upon mass deposited onto the filter and known physical characteristics of the filter media. Detailed are the methods used in conjunction with current filter loading models to predict the pressure drop, as well as tests conducted to validate the methods. The benefit of a prediction model for practical use lies in the manufacturing and service life of nuclear grade HEPA filters. HEPA filters for use in nuclear facilities have a prescribed expiration date and a maximum allowable operating pressure drop. Therefore, the ability to predict the pressure drop across a filter and relate it to an expected length of service time can enable a reduction in wasted filters. This will allow for more informed decisions to be made based upon the dictated life cycle of the filters. Also, understanding and predicting how the pressure drop of HEPA filter media behaves as a function of physical characteristics and loaded mass can assist in future design and manufacturing of filter media. Currently, most existing pressure drop models are either computationally based or analytical methods relying on data gathered during tests. Neither are practical for prediction; the computational methods are difficult to implement, and the current analytical methods are more useful as tools for analysis. The current analytical model developed by Bergman et al. is based upon the pressure drop from each media fiber and modeling the deposited particles as newly formed fibers. Using Bergman's model and the media properties, air properties, and known aerosol particle size distribution, a pressure drop curve as a function of loaded mass can be created. This curve implies initial loading in the depth of the filter media with a transition to pure surface loading on the filter face, and a sensitivity to an evolving particle size distribution as mass continues to load onto the filter. To implement the predictive model, knowledge of the mean filter fiber diameter and porosity of the filter media is required. Traditionally, the mean fiber diameter is calculated as an effective diameter from prior media testing, however, in this study a Scanning Electron Microscope (SEM) technique is used to acquire this variable. Validation of the predictive model is provided by flat sheet media tests under a controlled environment with a measured particle size distribution of the challenge aerosol and shows reasonable preliminary agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiosensitization of Chemotherapy-Refractory, Locally Advanced or Locally Recurrent Breast Cancer With Trastuzumab: A Phase II Trial

Purpose: Trastuzumab (Herceptin), an anti-human epidermal growth factor receptor 2 (HER2) antibody, has been shown to be an effective radiosensitizer in preclinical studies. The present Phase II trial evaluated trastuzumab plus radiotherapy in patients with HER2-positive, chemotherapy-refractory, locally advanced or locoregionally recurrent breast cancer. Methods and Materials: Eligible patients had measurable disease, normal cardiac function, and biopsy-confirmed residual HER2-positive disease. Patients received weekly trastuzumab (2 mg/kg intravenously), concurrent with radiotherapy (50 Gy) to the breast and regional lymph nodes for 5 weeks. If feasible, surgery followed radiotherapy. The primary endpoint was safety, and the secondary endpoint was efficacy (pathologic response and interval to symptomatic local progression). Results: Of the 19 patients enrolled, 7 were ineligible and received radiotherapy alone and 12 received therapy per protocol. Of these 12 patients, 11 had a Stage T4 diagnosis. Grade 3 toxicities included skin (n = 2) and lymphopenia (n = 1). One patient experienced delayed wound healing after surgery. No patients developed symptomatic cardiac dysfunction. Of the 7 patients who had undergone mastectomy, 3 (43%) had a substantial pathologic response (complete response or microscopic residual disease), significantly more than a comparison cohort (2 of 38 or 5%, p = .02). The median interval to symptomatic local progression was not reached. The median overall survival was 39 months. Conclusion: This is the first prospective trial providing evidence for a radiosensitizing effect of trastuzumab in breast cancer. The combination of trastuzumab and radiotherapy was well tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operation of a New COTS Crystal Oscillator - CXOMHT over a Wide Temperature Range

Crystal oscillators are extensively used in electronic circuits to provide timing or clocking signals in data acquisition, communications links, and control systems, to name a few. They are affordable, small in size, and reliable. Because of the inherent characteristics of the crystal, the oscillator usually exhibits extreme accuracy in its output frequency within the intrinsic crystal stability. Stability of the frequency could be affected under varying load levels or other operational conditions. Temperature is one of those important factors that influence the frequency stability of an oscillator; as it does to the functionality of other electronic components. Electronics designed for use in NASA deep space and planetary exploration missions are expected to be exposed to extreme temperatures and thermal cycling over a wide range. Thus, it is important to design and develop circuits that are able to operate efficiently and reliably under in these harsh temperature environments. Most of the commercial-off-the-shelf (COTS) devices are very limited in terms of their specified operational temperature while very few custom-made commercial and military-grade parts have the ability to operate in a slightly wider range of temperature than those of the COTS parts. These parts are usually designed for operation under one temperature extreme, i.e. hot or cold, and do not address the wide swing in the operational temperature, which is typical of the space environment. For safe and successful space missions, electronic systems must therefore be designed not only to withstand the extreme temperature exposure but also to operate efficiently and reliably. This report presents the results obtained on the evaluation of a new COTS crystal oscillator under extreme temperatures.

Patterson, Richard↗

High Data Rate Architecture (HiDRA)

One of the greatest challenges in developing new space technology is in navigating the transition from ground based laboratory demonstration at Technology Readiness Level 6 (TRL-6) to conducting a prototype demonstration in space (TRL-7). This challenge is com- pounded by the relatively low availability of new spacecraft missions when compared with aeronautical craft to bridge this gap, leading to the general adoption of a low-risk stance by mission management to accept new, unproven technologies into the system. Also in consideration of risk, the limited selection and availability of proven space-grade components imparts a severe limitation on achieving high performance systems by current terrestrial technology standards. Finally from a space communications point of view the long duration characteristic of most missions imparts a major constraint on the entire space and ground network architecture, since any new technologies introduced into the system would have to be compliant with the duration of the currently deployed operational technologies, and in some cases may be limited by surrounding legacy capabilities. Beyond ensuring that the new technology is verified to function correctly and validated to meet the needs of the end users the formidable challenge then grows to additionally include: carefully timing the maturity path of the new technology to coincide with a feasible and accepting future mission so it flies before its relevancy has passed, utilizing a limited catalog of available components to their maximum potential to create meaningful and unprecedented new capabilities, designing and ensuring interoperability with aging space and ground infrastructures while simultaneously providing a growth path to the future. The International Space Station (ISS) is approaching 20 years of age. To keep the ISS relevant, technology upgrades are continuously taking place. Regarding communications, the state-of-the-art communication system upgrades underway include high-rate laser terminals. These must interface with the existing, aging data infrastructure. The High Data Rate Architecture (HiDRA) project is designed to provide networked store, carry, and forward capability to optimize data flow through both the existing radio frequency (RF) and new laser communications terminal. The networking capability is realized through the Delay Tolerant Networking (DTN) protocol, and is used for scheduling data movement as well as optimizing the performance of existing RF channels. HiDRA is realized as a distributed FPGA memory and interface controller that is itself controlled by a local computer running DTN software. Thus HiDRA is applicable to other arenas seeking to employ next-generation communications technologies, e.g. deep space. In this paper, we describe HiDRA and its far-reaching research implications.

DTN↗

Extended Sleeve Products Allow Control and Monitoring of Process Fluid Flows Inside Shielding, Behind Walls and Beneath Floors - 13041

Throughout power generation, delivery and waste remediation, the ability to control process streams in difficult or impossible locations becomes increasingly necessary as the complexity of processes increases. Example applications include radioactive environments, inside concrete installations, buried in dirt, or inside a shielded or insulated pipe. In these situations, it is necessary to implement innovative solutions to tackle such issues as valve maintenance, valve control from remote locations, equipment cleaning in hazardous environments, and flow stream analysis. The Extended Sleeve family of products provides a scalable solution to tackle some of the most challenging applications in hazardous environments which require flow stream control and monitoring. The Extended Sleeve family of products is defined in three groups: Extended Sleeve (ESV), Extended Bonnet (EBV) and Instrument Enclosure (IE). Each of the products provides a variation on the same requirements: to provide access to the internals of a valve, or to monitor the fluid passing through the pipeline through shielding around the process pipe. The shielding can be as simple as a grout filled pipe covering a process pipe or as complex as a concrete deck protecting a room in which the valves and pipes pass through at varying elevations. Extended Sleeves are available between roughly 30 inches and 18 feet of distance between the pipeline centerline and the top of the surface to which it mounts. The Extended Sleeve provides features such as ± 1.5 inches of adjustment between the pipeline and deck location, internal flush capabilities, automatic alignment of the internal components during assembly and integrated actuator mounting pads. The Extended Bonnet is a shorter fixed height version of the Extended Sleeve which has a removable deck flange to facilitate installation through walls, and is delivered fully assembled. The Instrument Enclosure utilizes many of the same components as an Extended Sleeve, yet allows the installation of process monitoring instruments, such as a turbidity meter to be placed in the flow stream. The basis of the design is a valve body, which, rather than having a directly mounted bonnet has lengths of concentric pipe added, which move the bonnet away from the valve body. The pipe is conceptually similar to an oil field well, with the various strings of casing, and tubing installed. Each concentric pipe provides a required function, such as the outermost pipes, the valve sleeve and penetration sleeve, which provide structural support to the deck flange. For plug valve based designs, the next inner pipe provides compression on the environmental seals at the top of the body to bonnet joint, followed by the innermost pipe which provides rotation of the plug, in the same manner as an extended stem. Ball valve ESVs have an additional pipe to provide compressive loading on the stem packing. Due to the availability of standard pipe grades and weights, the product can be configured to fit a wide array of valve sizes, and application lengths, with current designs as short as seven inches and as tall as 18 feet. Central to the design is the requirement for no special tools or downhole tools to remove parts or configure the product. Off the shelf wrenches, sockets or other hand tools are all that is required. Compared to other products historically available, this design offers a lightweight option, which, while not as rigidly stiff, can deflect compliantly under extreme seismic loading, rather than break. Application conditions vary widely, as the base product is 316 and 304 stainless steel, but utilizes 17-4PH, and other allows as needed based on the temperature range and mechanical requirements. Existing designs are installed in applications as hot as 1400 deg. F, at low pressure, and separately in highly radioactive environments. The selection of plug versus ball valve, metal versus soft seats, and the material of the seals and seats is all dependent on the application requirements. The design of the Extended Sleeve family of products provides a platform which solves a variety of accessibility problems associated with controlling process flow streams in remote, hard to reach locations in harsh environments. Installation of the equipment described has shown to allow access to flow streams that otherwise would require exceptional means to access and control. The Extended Sleeve family of products provides a scalable solution to both control and monitor process fluid flow through shielding, walls or floors when direct connection is advantageous. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beta-Amino Carboxylate (BAC) non-aqueous physical solvents for enhanced CO2 separations in pre-combustion carbon capture, industrial CO 2 capture, and biogas upgrading processes

Novel beta-amino carboxylate (BAC) solvents have been synthesized and tested to efficiently capture carbon dioxide (CO 2 ) from process gas streams with CO 2 partial pressure intermediate between pre-combustion and post-combustion capture. The BAC solvents have molecular structures characterized by alkyl-substituted amides or esters containing a secondary amine functional group on the second carbon from the carbonyl carbon (referred to as the beta “β” carbon). The ester or amide functional group combined with optimal steric crowding around the amine nitrogen by proximate alkyl groups are tailored to modify the strength of CO 2 binding in the solvent. The solvents possess high CO 2 solubilities and high gas selectivity including good CO 2 /H 2 O selectivity and can be utilized for CO 2 absorption over a range of partial pressures. Due to low volatility, many of the solvents can be operated at or above ambient temperature which eliminates solvent chilling and allows regeneration using low grade waste heat. These novel solvents offer an opportunity for efficient carbon capture for a range of applications including biogas upgrading, hydrogen production, and pre-combustion carbon capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ATM Polymorphisms Predict Severe Radiation Pneumonitis in Patients With Non-Small Cell Lung Cancer Treated With Definitive Radiation Therapy

Purpose: The ataxia telangiectasia mutated (ATM) gene mediates detection and repair of DNA damage. We investigated associations between ATM polymorphisms and severe radiation-induced pneumonitis (RP). Methods and Materials: We genotyped 3 potentially functional single nucleotide polymorphisms (SNPs) of ATM (rs1801516 [D1853N/5557G>A], rs189037 [-111G>A] and rs228590) in 362 patients with non-small cell lung cancer (NSCLC), who received definitive (chemo)radiation therapy. The cumulative severe RP probabilities by genotypes were evaluated using the Kaplan-Meier analysis. The associations between severe RP risk and genotypes were assessed by both logistic regression analysis and Cox proportional hazard model with time to event considered. Results: Of 362 patients (72.4% of non-Hispanic whites), 56 (15.5%) experienced grade ≥3 RP. Patients carrying ATM rs189037 AG/GG or rs228590 TT/CT genotypes or rs189037G/rs228590T/rs1801516G (G-T-G) haplotype had a lower risk of severe RP (rs189037: GG/AG vs AA, adjusted hazard ratio [HR] = 0.49, 95% confidence interval [CI], 0.29-0.83, P=.009; rs228590: TT/CT vs CC, HR=0.57, 95% CI, 0.33-0.97, P=.036; haplotype: G-T-G vs A-C-G, HR=0.52, 95% CI, 0.35-0.79, P=.002). Such positive findings remained in non-Hispanic whites. Conclusions: ATM polymorphisms may serve as biomarkers for susceptibility to severe RP in non-Hispanic whites. Large prospective studies are required to confirm our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Secondary Electron Emission from Plasma Processed Accelerating Cavity Grade Niobium

Advances in the particle accelerator technology have enabled numerous fundamental discoveries in 20th century physics. Extensive interdisciplinary research has always supported further development of accelerator technology in efforts of reaching each new energy frontier. Accelerating cavities, which are used to transfer energy to accelerated charged particles, have been one of the main focuses of research and development in the particle accelerator field. Over the last fifty years, in the race to break energy barriers, there has been constant improvement of the maximum stable accelerating field achieved in accelerating cavities. Every increase in the maximum attainable accelerating fields allowed for higher energy upgrades of existing accelerators and more compact designs of new accelerators. Each new and improved technology was faced with ever emerging limiting factors. With the standard high accelerating gradients of more than 25 MV/m, free electrons inside the cavities get accelerated by the field, gaining enough energy to produce more electrons in their interactions with the walls of the cavity. The electron production is exponential and the electron energy transfer to the walls of a cavity can trigger detrimental processes, limiting the performance of the cavity. The root cause of the free electron number gain is a phenomenon called Secondary Electron Emission (SEE). Even though the phenomenon has been known and studied over a century, there are still no effective means of controlling it. The ratio between the electrons emitted from the surface and the impacting electrons is defined as the Secondary Electron Yield (SEY). A SEY ratio larger than 1 designates an increase in the total number of electrons. In the design of accelerator cavities, the goal is to reduce the SEY to be as low as possible using any form of surface manipulation. In this dissertation, an experimental setup was developed and used to study the SEY of various sample surfaces that were treated by different techniques. Specifically, this work provides the results of SEY from the plasma cleaned cavity grade niobium (Nb) samples. Pure niobium is currently the material of choice for the fabrication of Superconducting Radio Frequency (SRF) cavities. The effect of plasma processing with two different gases will be examined in two groups of samples. The first group of samples is made from cavity grade niobium. The second group of samples is made from the same material, but include a welded joint made by electron beam welding, since in niobium SRF cavities the peak electric and magnetic field are seen in close proximity to the welded joints. Both groups of samples will be exposed to nitrogen (N2) and a mixture of argon with oxygen (Ar/O2) plasma. It is the goal of this research to determine the SEY on these two groups of samples before and after plasma processing as a function of the energy of primary electrons. The SEY as a function of the angle of incidence of the primary electrons is tested on the samples treated with Ar/O2 plasma.

43 PARTICLE ACCELERATORS↗

Heart Rate Responses to Unaided Orion Side Hatch Egress in the Neutral Buoyancy Laboratory

NASA is developing the Orion capsule as a vehicle for transporting crewmembers to and from the International Space Station (ISS) and for future human space exploration missions. Orion and other commercial vehicles are designed to splash down in the ocean where nominally support personnel will assist crewmembers in egressing the vehicle. However, off-nominal scenarios will require crewmembers to egress the vehicle unaided, deploy survival equipment, and ingress a life raft. PURPOSE: To determine the heart rate (HR) responses to unaided Orion side hatch egress and raft ingress as a part of the NASA Crew Survival Engineering Team's evaluation of the PORT Orion mockup in the Neutral Buoyancy Laboratory (NBL). METHODS: Nineteen test subjects, including four astronauts (N=19, 14 males/5 females, 38.6+/-8.4 y, 174.4+/-9.6 cm, 75.7+/-13.1 kg), completed a graded maximal test on a cycle ergometer to determine VO2peak and HRpeak and were divided into five crews of four members each; one subject served on two crews. Each crew was required to deploy a life raft, egress the Orion vehicle from the side hatch, and ingress the life raft with two 8 kg emergency packs per crew. Each crew performed this activity one to three times; a total of ten full egresses were completed. Subjects wore a suit that was similar in form, mass, and function to the Modified Advanced Crew Escape Suit (MACES) including helmet, gloves, boots, supplemental O2 bottles, and a CO2-inflated life preserver (approx.18 kg); subjects began each trial seated supine in the PORT Orion mockup with seat belts and mockup O2 and communication connections and ended each trial with all four crewmembers inside the life raft. RESULTS: VO2peak was 40.8+/-6.8 mL/kg/min (3.1+/-0.7 L/min); HRpeak was 181+/-10 bpm. Total egress time across trials was 5.0+/-1.6 min (range: 2.8-8.0 min); all subjects were able to successfully complete all trials. Average maximum HR at activity start, at the hatch opening, in the water, and in the raft, was 108, 137, 147, and 153 bpm, respectively; these values corresponded to 59+/-10%, 73+/-8%, 82+/-3%, and 84+/-6% of HRpeak, respectively. The highest HRs were seen after raft ingress and ranged from 72-99% HRpeak. Across all trials, cumulative averages of 5.4, 3.0, 1.1, and 0.2 min were spent at HRs >60%, >70%, >80%, and >90% HRpeak, respectively. CONCLUSION: Unaided Orion side hatch egress in the NBL is a relatively short-duration activity that elicits a high HR response for several min. Although all crewmembers successfully completed this activity, additional factors such as high seas, poor visibility, an incapacitated crewmember, neurovestibular perturbation, and neuromuscular deconditioning characteristic of a true operational environment may increase the physiologic demand (or decrease crewmembers' physiologic capacity) of unaided Orion side hatch egress. Additionally, landing conditions may require the crewmembers to egress from the top hatch, which is expected to be even more physiologically demanding; this condition will be evaluated in subsequent collaborative testing with the NASA Crew Survival Engineering Team.

English, Kirk L.↗

Analysis of the Selective Flotation of Elemental Gold from Pyrite Using Diisobutyl Monothiophosphate

The gold contained in copper ores is an important resource for the gold industry. In some cases, elemental gold is present and can be recovered by selective flotation. It has been reported that the gold grade and recovery can be increased, without sacrificing the copper recovery, by replacing AERO 3477 (diisobutyl dithiophosphate (DTP)) with AERO 7249 (mixture of diisobutyl monothiophosphate (MTP) and diisobutyl dithiophosphate (DTP)) as the main collector. The fundamental understanding of the improvement in selectivity with the addition of MTP in the flotation of elemental gold from pyrite is limited and is the subject of this paper. In this regard, the hydrophobicity and selectivity of DTP and MTP in the flotation of pyrite and gold are compared and discussed. Density functional theory (DFT) was used to examine the electron density, reactivity, highest occupied molecular orbital (HOMO), and lowest unoccupied molecular orbital (LUMO) of the MTP and DTP collectors. The interaction energies for the adsorption of MTP and DTP from fresh pyrite, oxidized pyrite and gold surfaces were calculated and discussed with respect to the experimental results reported in the literature. Molecular dynamics simulation (MDS) was used to examine the adsorption state of MTP and DTP on the pyrite (100) and Au (111) surfaces.

58 GEOSCIENCES↗

Comparative Effects of Radiation Sterilization Modality on Medical PVC Tubing

As the production volume of single-use, polymer-based medical devices increases each year, so does the need for throughput capacity to sterilize the devices. Around 80% of radiation-sterilized devices are processed using gamma-ray radiation from industrial cobalt-60 sources. Supply chain, security, and disposal concerns are prompting manufacturers and contract sterilizers to explore alternatives to irradiation using cobalt-60 gamma-rays, such as electron beam (E-beam) and X-ray radiation. Advantages of these ‘machine’ sources over radioisotope-based sources are that they do not decay, a characteristic that requires cobalt-60 to be replaced over time, they can be turned off when not in use, and they do not represent the same level of concern regarding misuse. One of the barriers to direct transition from gamma-ray sterilization to E-beam or X-ray sterilization is concern over the relatively unknown effects of sterilization dose of these alternative modalities on the performance of medical device polymers. Commercially available medical devices sterilized with gamma-ray irradiation exhibit acceptable device function, acceptable mechanical performance, and acceptable discoloration. To be viable, alternate sterilization methods must not only achieve acceptable sterilization, but the process must also result in a product with functional, mechanical, and visual effects acceptable to customers and the regulator. Flexible polyvinyl chloride (PVC) is a plastic material that is commonly found in single-use medical devices and is known for its sensitivity to radiation processing. For instance, transparent PVC is known to yellow upon irradiation. To encouraging sterilization alternatives to cobalt-60 gamma-ray, we directly compared the effects of gamma-ray, E-beam, and X-ray radiation exposure at similar sterilization-relevant doses on key properties of medical grade PVC tubing.

cobalt-60↗

A Review of Software for Designing and Operating Quantum Networks

Quantum networks development is crucial to realizing a production-grade network that can support distributed sensing, secure communication, and utility-scale quantum computation. However, the transition from laboratory demonstration to deployable networks requires software implementations of architectures and protocols tailored to the unique constraints of quantum systems. This paper reviews the current state of software implementations for quantum networks, organized around a three-plane abstraction of infrastructure, logical, and control/service planes. We cover software for both designing quantum network protocols (e.g., SeQUeNCe, QuISP, and NetSquid) and operating testbeds, with a focus on essential control/service plane functions such as entanglement, topology, and resource management, in a proposed taxonomy. Our review highlights a persistent gap between theoretical architecture and protocol proposals and their realization in simulators or testbeds, particularly in dynamic topology and network management. We conclude by outlining open challenges and proposing a roadmap for developing scalable software architectures to enable hybrid, large-scale quantum networks.

Network Design↗

Materials Challenges and Opportunities for Energy Generation, Conversion, Delivery, and Storage (Applied Energy Tri-Laboratory Consortium Workshop Report)

This report documents the outcomes of the Tri-Laboratory Materials Workshop that was held July 31 and August 1, 2019 to begin addressing the needs, opportunities, and challenges associated with the development, fabrication, and testing of the needed materials and components for integrated hybrid energy systems (i.e., incorporating nuclear, fossil, and renewables for electric and thermal applications). This was accomplished by assembling the research program leads and principal investigators at Idaho National Laboratory (INL), National Energy Technology Laboratory (NETL), and National Renewable Energy Laboratory (NREL), who support the research and development of new technology and system integration. The team then identified and prioritized key materials development needs. This effort was intended to enhance communications and synergy among the Tri-Lab partners. Advanced functional and structural materials are central to transformative energy technologies for energy generation, conversion, delivery, and storage. With that in mind, the workshop focused on identifying and assessing the foundational materials research needs at both the basic and applied levels. Materials challenges include the ability to withstand harsh environments, such as high temperatures and pressures, corrosion, oxidation, or irradiation while maintaining flexible mission profiles and long service lifespans. Advanced energy system material challenges and needs range from materials for the capture, upgrading/concentration, storage, and delivery of low-grade heat to materials for high temperature environments that involve liquid metals, molten salt, and very high temperature gas heat delivery and storage systems. Material improvements are needed for hybrid energy systems due to accelerated corrosion and stress-fatigue failure of materials and equipment, which results from increased frequency and amplitude of thermal, mechanical, and electrical cycling of systems components. Multifunctional materials are needed for high temperature solid-oxide fuel cells, advanced electrochemical reactors, and in-process separation. Relative to materials manufacturing, application of advanced additive and subtractive methods need to be understood to develop both thin-layer homogenous materials and materials of graded composition. Materials modeling and machine learning will be critical to accelerate the design and production of power electronics, and nuclear reactor materials and fuel, as well as to gain an understanding of beneficial materials phenomena or deleterious microstructure evolution. There is also a need for standardized models, computational structures, data reporting protocols and modeling tools across the three laboratories. This would allow consistent results, analysis, and data sharing. Combining computational capabilities between the three laboratories (e.g., hardware, software) would greatly increase computational capabilities and throughput. The workshop identified the need for laboratories to anticipate and address problems that will occur during scale-up. Laboratory work must connect with industry to ensure that research focuses on processes that are scalable and marketable. Industry input and perspective are essential to guide laboratory research to meet these requirements and deploy new technology in industrial demonstrations. Another aspect of scale-up is the integration of multiple systems since new challenges often arise at the subsystem interfaces. Establishing a scale-up manufacturing demonstration/pilot plant, potentially as an industrial user facility, would be beneficial to the laboratories and industry. That modular scale-up manufacturing demonstration/pilot plant would allow researchers to find and resolve interface problems that cannot be identified by focusing only on individual parts. Communication exchanges among the organizers, attendees, and workshop survey responses indicate that the workshop was successful in achieving its goal to identify key technology gaps and research needs. Strong positive feedback was received on the sharing of ideas, capabilities, talent, and passion to move forward on the materials-related action items.

36 MATERIALS SCIENCE↗

The value of assessing pulmonary venous flow velocity for predicting severity of mitral regurgitation: A quantitative assessment integrating left ventricular function

Although alteration in pulmonary venous flow has been reported to relate to mitral regurgitant severity, it is also known to vary with left ventricular (LV) systolic and diastolic dysfunction. There are few data relating pulmonary venous flow to quantitative indexes of mitral regurgitation (MR). The object of this study was to assess quantitatively the accuracy of pulmonary venous flow for predicting MR severity by using transesophageal echocardiographic measurement in patients with variable LV dysfunction. This study consisted of 73 patients undergoing heart surgery with mild to severe MR. Regurgitant orifice area (ROA), regurgitant stroke volume (RSV), and regurgitant fraction (RF) were obtained by quantitative transesophageal echocardiography and proximal isovelocity surface area. Both left and right upper pulmonary venous flow velocities were recorded and their patterns classified by the ratio of systolic to diastolic velocity: normal (>/=1), blunted (<1), and systolic reversal (<0). Twenty-three percent of patients had discordant patterns between the left and right veins. When the most abnormal patterns either in the left or right vein were used for analysis, the ratio of peak systolic to diastolic flow velocity was negatively correlated with ROA (r = -0.74, P <.001), RSV (r = -0.70, P <.001), and RF (r = -0.66, P <.001) calculated by the Doppler thermodilution method; values were r = -0.70, r = -0.67, and r = -0.57, respectively (all P <.001), for indexes calculated by the proximal isovelocity surface area method. The sensitivity, specificity, and predictive values of the reversed pulmonary venous flow pattern for detecting a large ROA (>0.3 cm(2)) were 69%, 98%, and 97%, respectively. The sensitivity, specificity, and predictive values of the normal pulmonary venous flow pattern for detecting a small ROA (<0.3 cm(2)) were 60%, 96%, and 94%, respectively. However, the blunted pattern had low sensitivity (22%), specificity (61%), and predictive values (30%) for detecting ROA of greater than 0.3 cm(2) with significant overlap with the reversed and normal patterns. Among patients with the blunted pattern, the correlation between the systolic to diastolic velocity ratio was worse in those with LV dysfunction (ejection fraction <50%, r = 0.23, P >.05) than in those with normal LV function (r = -0.57, P <.05). Stepwise linear regression analysis showed that the peak systolic to diastolic velocity ratio was independently correlated with RF (P <.001) and effective stroke volume (P <.01), with a multiple correlation coefficient of 0.71 (P <.001). In conclusion, reversed pulmonary venous flow in systole is a highly specific and reliable marker of moderately severe or severe MR with an ROA greater than 0.3 cm(2), whereas the normal pattern accurately predicts mild to moderate MR. Blunted pulmonary venous flow can be seen in all grades of MR with low predictive value for severity of MR, especially in the presence of LV dysfunction. The blunted pulmonary venous flow pattern must therefore be interpreted cautiously in clinical practice as a marker for severity of MR.