Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow Conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Space station prototype Sabatier reactor design verification testing

A six-man, flight prototype carbon dioxide reduction subsystem for the SSP ETC/LSS (Space Station Prototype Environmental/Thermal Control and Life Support System) was developed and fabricated for the NASA-Johnson Space Center between February 1971 and October 1973. Component design verification testing was conducted on the Sabatier reactor covering design and off-design conditions as part of this development program. The reactor was designed to convert a minimum of 98 per cent hydrogen to water and methane for both six-man and two-man reactant flow conditions. Important design features of the reactor and test conditions are described. Reactor test results are presented that show design goals were achieved and off-design performance was stable.

Cusick, R. J.↗

Velocity sensor for slow flows

Inexpensive, easily-constructed device measures flows from 0.2 to 20 feet per second. Instrument is capable of measuring flow velocity and direction in cases where either velocity or density is so low that dynamic pressure is below measurable range. It can be made into hand held instrument for measuring ventilation and air conditioning flow.

Simon, W. E.↗

Overall and blade element performance of a 1.20-pressure-ratio fan stage with rotor blades reset -5 deg

A 51-cm-diam model of a fan stage for a short haul aircraft was tested in a single stage-compressor research facility. The rotor blades were set 5 deg toward the axial direction (opened) from design setting angle. Surveys of the air flow conditions ahead of the rotor, between the rotor and stator, and behind the stator were made over the stable operating range of the stage. At the design speed of 213.3 m/sec and a weight flow of 31.5 kg/sec, the stage pressure ratio and efficiency were 1.195 and 0.88, respectively. The design speed rotor peak efficiency of 0.91 occurred at the same flow rate.

Lewis, G. W., Jr.↗

Plenum response to simulated disturbances of the model and fan inlet guide vanes in a transonic tunnel

In order to aid in the design of the National Transonic Facility (NTF) control system, test section/plenum response studies were carried out in a 0.186 scale model of the NTF high speed duct. Two types of disturbances, those induced by the model and those induced by the compressor inlet guide vanes were simulated. Some observations with regard to the test section/plenum response tests are summarized as follows. A resonance frequency for the test section/plenum area of the tunnel of approximately 50 Hz was observed for Mach numbers from 0.40 to 0.90. However, since the plenum is 3.1 times (based on volume) too large for the scaled size of the test section, care must be taken in extrapolating these data to NTF conditions. The plenum pressure data indicate the existence of pressure gradients in the plenum. The test results indicate that the difference between test section static pressure and plenum pressure is dependent on test section flow conditions. Plenum response to inlet guide vane type disturbances appears to be slower than plenum response to test section disturbances.

Gloss, B. B.↗

Secondary stream and excitation effects on two-dimensional nozzle plume characteristics

In order to design two-dimensional nozzle/ejector systems for future high performance aircraft, the basic engine exhaust plume velocity and temperature decay as effected by the secondary stream (ejector) and decay augmentation means must be assessed. Included in the assessment of the plume decay characteristics are the effects of nozzle aspect ratio and nozzle/ejector flow conditions. Nozzle/ejector plume decay can be enhanced by suitable excitation of the plume shear layers. Correlation of these factors are developed in a manner similar to those previously developed for conic and dual-flow nozzle plumes.

Vonglahn, Uwe H.↗

Sound radiation from single and annular stream nozzles, with modal decomposition of in-duct acoustic power

An experimental program was carried out to study the acoustic characteristics of single and annular stream duct-nozzle systems at various flow conditions by using a refined acoustic impulse technique. In this technique, signal synthesis and signal averaging processes are incorporated to generate a desired impulsive signal from acoustic driver(s) and to eliminate background noise (flow noise) from in-duct and far field signals, respectively. The contribution of higher order modes to incident reflected and transmitted acoustic powers is accounted for by using a modal decomposition process. The annular stream terminations were tested statically at various annular stream flow velocities with no inner stream flow. The results derived from the experiments include in-duct acoustic powers, termination reflection coefficients, transmission coefficients, far field power, and acoustic dissipation.

Salikuddin, M.↗

Secondary stream and excitation effects on two-dimensional nozzle plume characteristics

In order to design two-dimensional nozzle/ejector systems for future high performance aircraft, the basic engine exhaust plume velocity and temperature decay as effected by the secondary stream (ejector) and decay augmentation means must be assessed. Included in the assessment of the plume decay characteristics are the effects of nozzle aspect ratio and nozzle/ejector flow conditions. Nozzle/ejector plume decay can be enhanced by suitable excitation of the plume shear layers. Correlations of these factors are developed in a manner similar to those previously developed for conic and dual-flow nozzle plumes.

Von Glahn, Uwe H.↗

Investigation at Mach Numbers 2.98 and 2.18 of Axially Symmetric Free-jet Diffusion with a Ram-jet Engine

An investigation was conducted to determine the effectiveness of a free-jet diffuser in reducing the over-all pressure ratios required to operate a free jet with a large air-breathing engine as a test vehicle. Efficient operation of the free jet was determined with and without the considerations required for producing suitable engine-inlet flow conditions. A minimum operating pressure ration of 5.5 was attained with a ratio of nozzle-exit to engine-inlet area of 1.85. Operation of the free jet with unstable engine-inlet flow (buzz) is also included.

WIND TUNNELS↗

Load distribution on a close-coupled wing canard at transonic speeds

This paper reports on a wind-tunnel test where load distributions were obtained at transonic speeds on both the canard and wing surfaces of a closely-coupled wing-canard configuration. The investigation included detailed component and configuration arrangement studies to provide insight into the various aerodynamic interference effects for the leading-edge vortex flow conditions encountered. Data indicate that increasing the Mach number from 0.70 to 0.95 caused the wing leading-edge vortex to burst over the wing when the wing was in the presence of the high canard. For some of the outboard span locations, the leading-edge vortex reattachment streamline intersects the wing trailing edge inboard of these span locations, thus, the Kutta condition was not satisfied. In general, the effect of adding a canard was to reduce the lift inboard and somewhat increase the lift outboard similar to the trends that would have been expected had the flow been attached.

Gloss, B. B.↗

A 2-D oscillating flow analysis in Stirling engine heat exchangers

A two dimensional oscillating flow analysis was conducted, simulating the gas flow inside Stirling heat exchangers. Both laminar and turbulent oscillating pipe flow were investigated numerically for Re(max) = 1920 (Va = 80), 10800 (Va = 272), 19300 (Va = 272), and 60800 (Va = 126). The results are compared with experimental results of previous investigators. Also, predictions of the flow regime on present oscillating flow conditions were checked by comparing velocity amplitudes and phase differences with those from laminar theory and quasi-steady profile. A high Reynolds number k-epsilon turbulence model was used for turbulent oscillating pipe flow. Finally, performance evaluation of the K-epsilon model was made to explore the applicability of quasi-steady turbulent models to unsteady oscillating flow analysis.

Ahn, Kyung H.↗

A 2-D oscillating flow analysis in Stirling engine heat exchangers

A two-dimensional oscillating flow analysis was conducted, simulating the gas flow inside Stirling heat exchangers. Both laminar and turbulent oscillating pipe flow were investigated numerically for Re(max) = 1920 (Va = 80), 10800 (Va = 272), 19300 (Va = 272), and 60800 (Va = 126). The results are compared with experimental results of previous investigators. Also, predictions of the flow regime on present oscillating flow conditions were checked by comparing velocity amplitudes and phase differences with those from laminar theory and quasi-steady profile. A high Reynolds number k-epsilon turbulence model was used for turbulent oscillating pipe flow. Finally, performance evaluation of the K-epsilon model was made to explore the applicability of quasi-steady turbulent models to unsteady oscillating flow analysis.

Ahn, Kyung H.↗

Study of secondary-flow patterns in an annular cascade of turbine nozzle blades with vortex design

In order to increase understanding of the origin of losses in a turbine, the secondary-flow components in the boundary layers and the blade wakes of an annular cascade of turbine nozzle blades (vortex design) was investigated. A detailed study was made of the total-pressure contours and, particularly, of the inner-wall loss cores downstream of the blades. The inner-wall loss core associated with a blade of the turbine-nozzle cascade is largely the accumulation of low-momentum fluids originating elsewhere in the cascade. This accumulation is effected by a secondary-flow mechanism which acts to transport the low-momentum fluids across the channels on the walls and radially in the blade wakes and boundary layers. The patterns of secondary flow were determined by use of hydrogen sulfide traces, paint, flow fences, and total pressure surveys. At one flow condition investigated, the radial transport of low-momentum fluid in the blade wake and on the suction surface near the trailing edge accounted for 65 percent of the loss core; 30 percent resulted from flow in the thickened boundary layer on the suction surface and 35 percent from flow in the blade wake.

FLOW, SUBSONIC↗

Tip-Clearance Vortex Characterized With Three-Dimensional Digital Particle Image Velocimetry

An optical measurement technique known as Three-Dimensional Digital Particle Image Velocimetry (3-D DPIV) was used to characterize the tip clearance flow in NASA Glenn Research Center's low-speed axial compressor. 3-D DPIV is a technique in which a stereoscopic imaging system consisting of two cross-correlation cameras is used to record particles entrained in a flow as a laser light sheet is pulsed at two instances in time. Although 3-D DPIV has been used elsewhere, this is the first time it has been used to measure compressor tip clearance flows. In-house modifications of the DPIV system include the use of effective seeding technology and a novel system to perform a priori calibrations at all five measurement planes, greatly reducing facility run time. Computational fluid dynamics predictions, which are used to guide design changes toward improving the efficiency and operating range of turbomachinery, can be verified and improved by comparison with 3-D DPIV measurements of the actual tip clearance flow. This measurement campaign dealt with the characterization of the tip clearance vortex in the first stage of a four-stage axial compressor. The tip clearance vortex is formed in compressors operating with a clearance gap between the moving rotor blade tips and the stationary casing when a leakage flow, forced from the pressure side of the blade over the blade tip, forms a vortical structure on the suction side of the blade. 3-D DPIV is ideally suited to measure the clearance vortex for two reasons: (1) this technique captures the entire blade passage flow at one instant in time, so that wandering of the vortex during the measurement does not smear out velocity gradients in the flow field, and (2) the spanwise component of velocity changes sign across the vortex core, providing a more accurate measurement of the vortex location than was available with previous two-dimensional measurement approaches. These two attributes of the data will enable computational fluid dynamics researchers to validate their predictions to a level of accuracy not previously attainable. In an effort to understand the effects of this flow phenomenon on the operation of the low speed axial compressor, data were acquired at two mass flow coefficients: 0.395 (design operating point) and 0.35 (operating point just above stall). In order to identify the spatial extent, location, and magnitude of the tip clearance vortex for each mass flow condition, data were acquired at five equally spaced spanwise locations, from 90- to 100-percent span. The data presented shows a cross section of the tip clearance vortex at 94-percent span and a mass flow coefficient of 0.395, where the color contours represent the radial velocity component. The blue (flow towards the hub) and red (flow towards the casing) regions illustrate the extent of the tip clearance vortex. The interface between the blue and red regions delineates the location of the vortex core.

John, W. Trevor↗

Exploratory Investigation of Aerodynamic Characteristics of Helicopter Tail Boom Cross-Section Models with Passive Venting

Two large-scale, two-dimensional helicopter tail boom models were used to determine the effects of passive venting on boom down loads and side forces in hovering crosswind conditions. The models were oval shaped and trapezoidal shaped. Completely porous and solid configurations, partial venting in various symmetric and asymmetric configurations, and strakes were tested. Calculations were made to evaluate the trends of venting and strakes on power required when applied to a UH-60 class helicopter. Compared with the UH-60 baseline, passive venting reduced side force but increased down load at flow conditions representing right sideward flight. Selective asymmetric venting resulted in side force benefits close to the fully porous case. Calculated trends on the effects of venting on power required indicated that the high asymmetric oval configuration was the most effective venting configuration for side force reduction, and the high asymmetric with a single strake was the most effective for overall power reduction. Also, curves of side force versus flow angle were noticeable smoother for the vented configurations compared with the solid baseline configuration; this indicated a potential for smoother flight in low-speed crosswind conditions.

Banks, Daniel W.↗

Deployable Aeroshell Flexible Thermal Protection System Testing

Deployable aeroshells offer the promise of achieving larger aeroshell surface areas for entry vehicles than otherwise attainable without deployment. With the larger surface area comes the ability to decelerate high-mass entry vehicles at relatively low ballistic coefficients. However, for an aeroshell to perform even at the low ballistic coefficients attainable with deployable aeroshells, a flexible thermal protection system (TPS) is required that is capable of surviving reasonably high heat flux and durable enough to survive the rigors of construction handling, high density packing, deployment, aerodynamic loading and aerothermal heating. The Program for the Advancement of Inflatable Decelerators for Atmospheric Entry (PAIDAE) is tasked with developing the technologies required to increase the technology readiness level (TRL) of inflatable deployable aeroshells, and one of several of the technologies PAIDAE is developing for use on inflatable aeroshells is flexible TPS. Several flexible TPS layups were designed, based on commercially available materials, and tested in NASA Langley Research Center's 8 Foot High Temperature Tunnel (8ft HTT). The TPS layups were designed for, and tested at three different conditions that are representative of conditions seen in entry simulation analyses of inflatable aeroshell concepts. Two conditions were produced in a single run with a sting-mounted dual wedge test fixture. The dual wedge test fixture had one row of sample mounting locations (forward) at about half the running length of the top surface of the wedge. At about two thirds of the running length of the wedge, a second test surface drafted up at five degrees relative to the first test surface established the remaining running length of the wedge test fixture. A second row of sample mounting locations (aft) was positioned in the middle of the running length of the second test surface. Once the desired flow conditions were established in the test section the dual wedge test fixture, oriented at 5 degrees angle of attack down, was injected into the flow. In this configuration the aft sample mounting location was subjected to roughly twice the heat flux and surface pressure of the forward mounting location. The tunnel was run at two different conditions for the test series: 1) 'Low Pressure', and 2) 'High Pressure'. At 'Low Pressure' conditions the TPS layups were tested at 6W/cm2 and 11W/cm2 while at 'High Pressure' conditions the TPS layups were tested at 11W/cm2 and 20W/cm2. This paper details the test configuration of the TPS samples in the 8Ft HTT, the sample holder assembly, TPS sample layup construction, sample instrumentation, results from this testing, as well as lessons learned.

Hughes, Stephen J.↗

Effect of several porous casing treatments on stall limit and on overall performance of an axial flow compressor rotor

Several geometrically different porous casings were tested with an axial-flow compressor rotor to determine their effects upon the rotor stall-limit line and overall performance. The tests were conducted using both uniform and nonuniform inlet-flow conditions. The rotor performance with the various casing treatments is compared with that obtained with a solid casing. The ability of the various casing treatments to displace the rotor stall-limit line to lower weight flows was observed. Significant stall-margin increases were obtained with several of the porous casings. Peak efficiencies with two of the porous casings were as high as or slightly higher than that obtained with solid casing.

Osborn, W. M.↗

Effects of reset stators and a rotating, grooved stator hub on performance of a 1.92-pressure-ratio compressor stage

The overall performance and blade-element performance of a transonic fan stage are presented for two modified test configurations and are compared with the unmodified stage. Tests were conducted with reset stators 2 deg open and reset stators with a rotating grooved stator hub. Detailed radial and circumferential (behind stator) surveys of the flow conditions were made over the stable operating range at rotative speeds of 70, 90, and 100 percent of design speed. Reset stator blade tests indicated a small increase in stage efficiency, pressure ratio, and maximum weight flow at each speed. Performance with reset stators and a rotating, grooved stator hub resulted in an additional increase in stage efficiency and pressure ratio at all speeds. The rotating grooved stator hub reduced hub losses considerably.

Lewis, G. W., Jr.↗

Concerning the flow about ring-shaped cowlings Part VI : further measurements on inlet devices

The present report presents as a supplement to the fourth report (available as ATI 5045, Air Materiel Command) in the series of investigations concerning the flow about ring-shaped cowlings further wind-tunnel measurements on inlet devices which are to show the influence of the radius of the nose of the cowling on the flow conditions. Moreover, a simple rule for the design of such arrangements, containing a hub in the interior, is suggested.

AIR FLOW - ENGINE COWLINGS↗