Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Calibration of TOPEX/POSEIDON at Platform Harvest

We present estimates for the mean bias of the TOPEX/POSEIDON NASA altimeter (ALT) and the Centre National d'Etudes Spatiales altimeter (SSALT) using in-situ data gathered at Platform Harvest during the first 36 cycles of the mission. Data for 21 overflights of the ALT and six overflights of the SSALT have been analyzed. The analysis includes an independent assessment of in-situ measurements of sea level, the radial component of the orbit, wet tropospheric path delay, and ionospheric path delay. (The sign convention used is such that, to correct the geophysical data record values for sea level, add the bias algebraically. Unless otherwise stated, the uncertainty in a given parameter is depicted by +/- sigma(sub x), where sigma(sub x) is the sample standard deviation of x about the mean.) Tide gauges at Harvest provide estimates of sea level with an uncertainty of +/- 1.5 cm. The uncertainty in the radial component of the orbit is estimated to be +/- 1.3 cm. In-situ measurements of tropopsheric path delay at Harvest compare to within +/- 1.3 cm of the TOPEX/POSEIDON microwave radiometer, and in-situ measurements of the ionospheric path delay compare to within -0.4 +/- 0.7 cm of the dual-frequency ALT and 1.1 +/- 0.6 cm of Doppler orbitography and radiopositioning integrated by satellite. We obtain mean bias estimates of -14.5 +/- 2.9 cm for the ALT and +0.9 +/- 3.1 cm for the SSALT (where the uncertainties are based on the standard deviation of the estimated mean (sigma(sub bar x/y), which is derived from sample statistics and estimates for errors that cannot be observed). These results are consistent with independent estimates for the relative bias between the two altimeters. A linear regression applied to the complete set of data shows that there is a discernable secular trend in the time series for the ALT bias estimates. A preliminary analysis of data obtained through cycle 48 suggests that the apparent secular drift may be the result of a poorly sampled annual signal.

Christensen, E. J.↗

Using Digital Image Correlation for Material Testing at Cryogenic Temperatures

Recent efforts were made to parametrize an aluminum alloy at cryogenic temperatures to calibrate finite element models simulating material deformation. Digital image correlation (DIC) was used to measure material properties using front/back strains of specimens during tensile tests. Data acquired from DIC was compared to physical extensometer measurements. Two camera pairs (front and back) were mounted via aluminum extrusion to the exterior of an environmental chamber of a hydraulic test stand. Images were taken through single-pane optical glass windows of the environment chamber. Positive pressure bags encased the cameras, attaching to the perimeter of the glass to keep out moisture and prevent windows from frosting. Figure 1 shows the environmental setup and the camera setup during cryogenic testing. Some of the challenges during testing at cryogenic temperatures include the gaseous flow of liquid nitrogen in the optical path of the mounted cameras, frost buildup on the windows as seen in Figure 1b, and frost on the test coupon. The temperature gradient present during the introduction of liquid nitrogen into the chamber can increase the projection error of images captured of the specimen. Figure 2 shows the estimated projection error from DIC as a function of temperature during the cool down process. This presentation addresses some of the concerns and observations when using DIC for testing at cryogenic temperatures using methods of isolated camera system and techniques for maintaining the glass panel clear from frost.

Joseph Cochran↗

Underlying Fundamentals of Kalman Filtering for River Network Modeling

The grand challenge of producing hydrometeorological estimates every time and everywhere has motivated the fusion of sparse observations with dense numerical models, with a particular interest on discharge in river modeling. Ensemble methods are largely preferred as they enable the estimation of error properties, but at the expense of computational load and generally with underestimations. These imperfect stochastic estimates motivate the use of correction methods, that is, error localization and inflation, although the physical justifications for their optimality are limited. The purpose of this study is to use one of the simplest forms of data assimilation when applied to river modeling and reveal the underlying mechanisms impacting its performance. Our framework based on assimilating daily averaged in situ discharge measurements to correct daily averaged runoff was tested over a 4-yr case study of two rivers in Texas. Results show that under optimal conditions of inflation and localization, discharge simulations are consistently improved such that the mean values of Nash–Sutcliffe efficiency are enhanced from211.32 to 0.55 at observed gauges and from212.24 to21.10 at validation gauges. Yet, parameters controlling the inflation and the localization have a large impact on the performance. Further investigations of these sensitivities showed that optimal inflation occurs when compensating exactly for discrepancies in the magnitude of errors while optimal localization matches the distance traveled during one assimilation window. These results may be applicable to more advanced data assimilation methods as well as for larger applications motivated by upcoming river-observing satellite missions, such as NASA’s Surface Water and Ocean Topography mission.

Streamflow↗

Single Event Test Methodologies and System Error Rate Analysis for Triple Modular Redundant Field Programmable Gate Arrays

We present a test methodology for estimating system error rates of Field Programmable Gate Arrays (FPGAs) mitigated with Triple Modular Redundancy (TMR). The test methodology is founded in a mathematical model, which is also presented. Accelerator data from 90 nm Xilins Military/Aerospace grade FPGA are shown to fit the model. Fault injection (FI) results are discussed and related to the test data. Design implementation and the corresponding impact of multiple bit upset (MBU) are also discussed.

error rate calculations↗

X-ray emission from the region of gamma 195+5

In the present study, the region of the gamma 195 + 5 was searched for X-ray emission to a level of approximately 10 to the minus eleventh erg/sq cm-sec. A source is detected whose position is in agreement with the position of the gamma-ray source. The area of the X-ray box is approximately five times smaller than the estimated gamma-ray error region; it will guide further observations at X-ray and other wavelengths. The probability that the source is located by chance within the gamma-ray error region is estimated at 9%. The X-ray spectrum appears to be too steep to extrapolate simply toward the 100 MeV point.

Lamb, R. C.↗

Statistical tests for closure of plate motion circuits

Two methods, one based on a chi-square test and the second on an F-ratio test, of testing for the plate motion circuit closures are described and evaluated. The chi-square test is used to evaluate goodness of fit, and it is assumed that the assigned errors are accurate estimates of the true errors in the data. The F-ratio test is used to compare variances of distributions, and it is assumed that the relative values of assigned error are accurate. The two methods are applied to the data of Minster and Jordan (1978) on the motion of the three plates that meet at the Galapagos Triple Junction, and the motion of the three plates that meet at the Indian Ocean Triple Junction. It is noted that the F-ratio plate circuit closure test is more useful than the chi-square test for identifying systematic misfits in data because the chi-square test overestimates the errors of plate motion data.

Gordon, Richard G.↗

Adaptive methods in computational fluid dynamics

A review is conducted of the basic components of adaptive methods applicable to very complex problems in fluid dynamics. Attention is given to ways of changing the structure of an approximation to reduce error, techniques for estimating the evolution of error in a CFD calculation, and the range of algorithms that are currently available for mesh-changing functions. Available numerical results which demonstrate the viability of these approaches are discussed.

Oden, J. T.↗

Nonlinear Observers for Gyro Calibration Coupled with a Nonlinear Control Algorithm

Nonlinear observers for gyro calibration are presented. The first observer estimates a constant gyro bias. The second observer estimates scale factor errors. The third observer estimates the gyro alignment for three orthogonal gyros. The observers are then combined. The convergence properties of all three observers, and the combined observers, are discussed. Additionally, all three observers are coupled with a nonlinear control algorithm. The stability of each of the resulting closed loop systems is analyzed. Simulated test results are presented for each system.

Thienel, Julie↗

Nonlinear Observers for Gyro Calibration

Nonlinear observers for gyro calibration are presented. The first observer estimates a constant gyro bias. The second observer estimates scale factor errors. The third observer estimates the gyro alignment for three orthogonal gyros. The convergence properties of all three observers are discussed. Additionally, all three observers are coupled with a nonlinear control algorithm. The stability of each of the resulting closed loop systems is analyzed. Simulated test results are presented for each system.

Thienel, Julie↗

Is There A Relationship Between Cornered-Hat Methods and A Residual Approach to Estimate System Uncertainty?

Recently a relationship has been established between a now traditional residual diagnostic used to estimate observation, background and analysis error covariances of interest to data assimilation and the three-cornered hat (3CH) method. An existing extension of the traditional residual diagnostic uses residuals from a fixed lag-1 Kalman smoother to retrieve system (model) error covariance. It is thus natural to ask if an additional relationship can be established between this extended residual method and some form of cornered--hat method. The answer might seem straightforward. Unlike in the standard residual estimation case, attempting to estimate model error amounts to estimating the statistics of a residual quantity itself. As shown in this presentation, in such cases the 3CH method becomes trivial: the sought out uncertainty can be derived directly from the covariance of the residual quantity at hand. In the particular case of estimating model error, one of the corners would have to be composed of vectors providing estimates of model error; these are not typically available in practice. Therefore, at first glance the present work finds no relationship between the lag-1 smoother residual diagnostic for system error estimation and cornered--hat methods. However, the work suggests that a two-tiered 3CH might be all that is necessary for system uncertainty to be obtained with 3CH.

Ricardo Todling↗

Towards a more realistic representation of NASA CERES-derived surface radiative fluxes during polar night: a comparison with the MOSAiC field campaign

The Arctic is one of the most sensitive regions of Earth to climate change, and yet remains one of the more difficult regions to both observe and simulate. The high latitude of the Arctic gives it some unusual features compared with much of Earth, such as large and variable sea ice cover, extensive mixed phase cloud cover, and the polar day/night cycle. These features significantly influence the radiative environment of the Arctic as well as the ability to observe it. The remoteness of the Arctic from most of civilization makes large volumes of in situ observations difficult to collect, and so satellite observations are a critical tool for observing the region, such as those from Clouds and the Earth’s Radiant Energy System (CERES). But validating the satellite radiative flux estimates is difficult because of the lack of in situ measurements. A useful remedy is utilizing measurements from field campaigns, such as the year-long Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition during 2019-2020. The extensive high-quality surface radiative flux and meteorological measurements collected from MOSAiC provide a useful check on flux retrievals from CERES instruments. Previous work compared MOSAiC and CERES surface radiative fluxes during the 2020 melt season (April-September). Errors in CERES fluxes were related to errors in estimated atmospheric optical depth and surface albedo. We conduct a similar assessment of CERES surface flux retrievals using MOSAiC data, but for the months of October through March instead. As this time period is mostly during polar night and twilight, the focus of the study is on longwave surface fluxes. To better understand the reasons for errors in CERES fluxes, we use the large set of meteorological measurements also collected by MOSAiC, including surface temperature, thermodynamic vertical profiles, surface turbulent fluxes, and cloud properties. For example, one notable possible source of error in the CERES estimate of surface downwelling longwave flux is the estimate of cloud base height when compared with MOSAiC W-band radar measurements – an overestimate of cloud base height yields an underestimate of the downwelling flux on the order of tens of W m2.

J. Brant Dodson↗

Fusion techniques using distributed Kalman filtering for detecting changes in systems

A comparison is made of the performances of two detection strategies that are based on different data fusion techniques. The strategies detect changes in a linear system. One detection strategy involves combining the estimates and error covariance matrices of distributed Kalman filters, generating a residual from the used estimates, comparing this residual to a threshold, and making a decision. The other detection strategy involves a distributed decision process in which estimates from distributed Kalman filters are used to generate distributed residuals which are compared locally to a threshold. Local decisions are made and these decisions are then fused into a global decision. The performances of each of these detection schemes are compared, and it is concluded that better performance is achieved when local decisions are made and then fused into a global decision.

Belcastro, Celeste M.↗

Detection of the Pairwise Kinematic Sunyaev-Zel'dovich Effect with BOSS DR11 and the Atacama Cosmology Telescope

We present a new measurement of the kinematic Sunyaev-Zel'dovich effect using data from the Atacama Cosmology Telescope (ACT) and the Baryon Oscillation Spectroscopic Survey (BOSS). Using 600 square degrees of overlapping sky area, we evaluate the mean pairwise baryon momentum associated with the positions of 50,000 bright galaxies in the BOSS DR11 Large Scale Structure catalog. A non-zero signal arises from the large-scale motions of halos containing the sample galaxies. The data fits an analytical signal model well, with the optical depth to microwave photon scattering as a free parameter determining the overall signal amplitude. We estimate the covariance matrix of the mean pairwise momentum as a function of galaxy separation, using microwave sky simulations, jackknife evaluation, and bootstrap estimates. The most conservative simulation-based errors give signal-to-noise estimates between 3.6 and 4.1 for varying galaxy luminosity cuts. We discuss how the other error determinations can lead to higher signal-to-noise values, and consider the impact of several possible systematic errors. Estimates of the optical depth from the average thermal Sunyaev-Zel'dovich signal at the sample galaxy positions are broadly consistent with those obtained from the mean pairwise momentum signal.

De Bernardis, F.↗

Applications of parameter estimation in the study of spinning airplanes

Spinning airplanes offer challenges to estimating dynamic parameters because of the nonlinear nature of the dynamics. In this paper, parameter estimation techniques are applied to spin flight test data for estimating the error in measuring post-stall angles of attack, deriving Euler angles from angular velocity data, and estimating nonlinear aerodynamic characteristics. The value of the scale factor for post-stall angles of attack agrees closely with that obtained from special wind-tunnel tests. The independently derived Euler angles are seen to be valid in spite of steep pitch angles. Estimates of flight derived nonlinear aerodynamic parameters are evaluated in terms of the expected fit error.

W Taylor, L., Jr.↗

Age estimation of the Deccan Traps from the North American apparent polar wander path

It has recently been proposed that flood basalt events, such as the eruption of the Deccan Traps, have been responsible for mass extinctions. To test this hypothesis, accurate estimations of the ages and duration of these events are needed. In the case of the Deccan Traps, however, neither age nor duration of emplacement is well constrianed; measured ages range from 40 to more than 80 Myr, and estimates of duration range from less than 1 to 67 Myr. To make an independent age determination, paleomagnetic and sea-floor-spreading data are used, and the associated errors are estimated. The Deccan paleomagnetic pole is compared with the reference apparent polar wander path of North America by rotating the positions of the paleomagnetic pole for the Deccan Traps to the reference path for a range of assumed ages. Uncertainties in the apparent polar wander path, Deccan paleopole position, and errors resulting from the plate reconstruction are estimated. It is suggested that 83-70 Myr is the most likely time of extrusion of these volcanic rocks.

Stoddard, Paul R.↗

Stability and Control Estimation Flight Test Results for the SR-71 Aircraft With Externally Mounted Experiments

A maximum-likelihood output-error parameter estimation technique is used to obtain stability and control derivatives for the NASA Dryden Flight Research Center SR-71A airplane and for configurations that include experiments externally mounted to the top of the fuselage. This research is being done as part of the envelope clearance for the new experiment configurations. Flight data are obtained at speeds ranging from Mach 0.4 to Mach 3.0, with an extensive amount of test points at approximately Mach 1.0. Pilot-input pitch and yaw-roll doublets are used to obtain the data. This report defines the parameter estimation technique used, presents stability and control derivative results, and compares the derivatives for the three configurations tested. The experimental configurations studied generally show acceptable stability, control, trim, and handling qualities throughout the Mach regimes tested. The reduction of directional stability for the experimental configurations is the most significant aerodynamic effect measured and identified as a design constraint for future experimental configurations. This report also shows the significant effects of aircraft flexibility on the stability and control derivatives.

Moes, Timothy R.↗

An improved error assessment for the GEM-T1 gravitational model

Several tests have been designed to estimate the correct error variances for the GEM-T1 gravitational solution that was derived exclusively from satellite tracking data. The basic method uses both independent and dependent subset data solutions and produces a coefficient-by-coefficient estimate of the model uncertainties. The GEM-T1 errors have been further analyzed using a method based on eigenvalue-eigenvector analysis, which calibrates the entire covariance matrix. Dependent satellite data sets and independent altimetric, resonant satellite, and surface gravity data sets all confirm essentially the same error assessment. The calibration test results yield very stable calibration factors, which vary only by approximately 10 percent over the range of tests performed. Based on these calibrated error estimates, GEM-T1 is a significantly improved solution, which to degree and order 8 is twice as accurate as earlier satellite derived models like GEM-L2. Also, by being complete to degree and order 36, GEM-T1 is more complete and has significantly reduced aliasing effects that were present in previous models.

Lerch, F. J.↗