Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Assessing Cybersecurity Resilience of Distributed Ledger Technology in Energy Sector Using the MITRE ATT&CK® ICS Framework

Digitization in the power industry enables wide connectivity among multiple new entrants such as DERs, prosumers, and P2P counterparts within or outside the Distributed Ledger Technology (DLT). The use of DLT to improve resilience in the power grid has growing support, but new technology provides new opportunities for adversaries to cause harm. This work completed by the Cybersecurity- focused task force of IEEE SA P2418.5 evaluates the potential risks by applying the MITRE ATT&CK® ICS matrix to the DLT Engineering and Cybersecurity Stack designed for power systems applications

Gourisetti, Sri Nikhil Gupta↗

2022 Project Commercialization and Market Development Awardee: Eocycle America Corporation

Annually, agriculture and related industries contribute approximately $1.2 trillion to the U.S. gross domestic product and 11% of the nation's output of greenhouse gas (GHG) emissions. At the same time, agribusiness operations account for about 30% of energy use worldwide. Distributed wind energy produced on site can power large-scale agricultural, industrial, and commercial operations in windy rural areas, offering cost savings, GHG emissions reductions, and the potential to supply excess electricity to the grid. Despite these benefits, agribusinesses have been slow to embrace the technology. Eocycle America Corporation (Eocycle) plans to develop partnerships with agriculture and related industries and implement a marketing strategy to educate corporate customers about the benefits of distributed wind. Through the CIP initiative, Eocycle will create a marketing plan to raise interest in distributed wind energy among large American and European corporations with operations in rural areas. Campaign goals are to encourage rapid deployment of distributed wind energy on a large scale, as well as to create high-paying energy sector jobs through increased manufacturing, sales, maintenance, and related services. Eocycle plans to identify 15 agriculture-related corporations with the potential for at least 25 turbine sales each.

Competitiveness Improvement Project↗

Cycloidal wave energy converter using fixed differential buoyancy to control operating torques

A floating mooring system for a single CycWEC applies counter forces and torques to keep a generator suitably stationary for power generation without requiring fixed attachments to the ocean floor or requiring a large frame interconnecting multiple CycWECs. The mooring system uses floats or floatation structure with differential ballasting to counter operating torque and drag plates to counter reactive forces. The floatation structures may be used to float the CycWEC for transport to a deployment location, where changing the overall ballasting of the floatation structures submerges the CycWEC to a desired depth and differential ballasting in the floatation structures counts expected operating torques.

Siegel, Stefan G.↗

Investigation of Nonflammable Electrolytes for Behind-the-Meter Storage Batteries

Behind-the-Meter Storage (BTMS) is a battery-based, stationary energy storage system that is connected to the residential or industrial customer's side of the electrical grid utility service meter. BTMS systems enable consumers to (A) economically schedule charging and usage of stored energy, (B) store and use energy from on-site generation, especially from inconstant, renewable sources like solar and wind, and (C) avoid overloading the grid during peak hours via supplementation with stored energy. BTMS battery performance requirements and general priorities differentiate from other applications, like EVs, which has prompted the development of batteries with tailored electrode and electrolyte materials. These materials prioritize low cost, avoiding critical materials; longevity, achieving 8000 cycle and 20-year shelf lives; and importantly, high safety. Nonflammable electrolytes show promise to improve safety by mitigating thermal runaway, yet often come with sacrifices to battery performance. In this presentation (1) primary categories of nonflammable electrolytes will be discussed; (2) a rational design of experiment will be presented for efficient performance evaluation of several nonflammables electrolyte in BTMS-relevant battery chemistry, Li4Ti5O12- and LiNi0.90Mn0.10O2; and (3) preliminary results will be presented.

battery↗

The Effects of Impactor Shape on the Compression After Impact Strength of Carbon/Epoxy Face Sheet Foam Core Sandwich Structure

This study presents experimental results of compression after impact (CAI) strength testing of foam core sandwich structure with carbon/epoxy face sheets impacted at three different energies with either a blunt or sharp tip impactor. The impact energies used were chosen to span the barely visible impact damage (BVID) thresholds for the sharp (4.1 J) and blunt (12.9 J) impactors with an impact energy approximately halfway between these (8.1 J) also used. While most impact testing on composites utilize a hemispherical (blunt) impactor, actual damage to a part may be due to an object impacting the part that is not blunt, but sharp and the impact response and resulting CAI strength values may be different for a given impact energy level. In this study, with regards to the impact response, the sandwich specimens showed larger transverse displacements (by about a factor of two) during the impact event when impacted by a sharp impactor versus a blunt impactor. The maximum load of impact was larger for the blunt impactor by about a factor of three. The barely visible impact damage (BVID) threshold energy was lower by about a factor of three for the sharp impactor. The absorbed energy of impact was higher for the sharp impactor. The CAI strength results showed that the sharp impactor gave lower average CAI strength values at the lowest impact energy level used, slightly lower average CAI strength values for the medium impact energy used and about the same average CAI strength values for the highest impact energy used.

sandwich structure↗

Analysis of Space-Conditioning Loads in Commercial Buildings

Space conditioning end-uses, which include heating, cooling, and ventilation, represent a significant fraction of commercial building energy use, with a wide variety of heating and cooling technology options available in the market. In the interest of improving the overall efficiency of heating, ventilation and air-conditioning (HVAC) technologies, governments, utilities and private sector entities have implemented a variety of market transformation policies that aim to influence consumer purchase decisions. To evaluate the costs and benefits of such programs, analysts typically postulate a hypothetical default equipment choice, and compare it to one that provides comparable service with lower energy and/or power use. The corresponding reduced operating cost provides a benefit that offsets the potential higher cost of improved efficiency. Typically, life-cycle cost or cash-flow analyses are used to quantify the net economic benefit. These analyses require the capability to assess how a given equipment design would perform across a broad range of characteristics, both of the building and of the local weather. While these assessments can be performed using customized building simulations, it is generally not practical to develop and validate detailed building simulation code to cover all the potential variations of equipment design and installation. An alternative, and somewhat simpler, approach is to solely use detailed building simulations to generate time series of heating and cooling loads in commercial buildings. These loads can then be used as input to more detailed, stand-alone engineering models that simulate HVAC system performance under different equipment designs. This approach was used to evaluate a range of high-efficiency commercial packaged air conditioner design options for the Department of Energy’s Appliance and Equipment Standards Program (DOE-EERE 2015). While there may be some loss of precision relative to full simulation, the accuracy of this approach is sufficient for practical applications of cost-benefit analysis. This report describes the development of a database of commercial building heating and cooling loads, generated using the EnergyPlus software package, a whole building energy use model supported by the Department of Energy (DOE-EERE 2020a). EnergyPlus takes as input a set of configuration files that describe the building itself (size, zoning, envelope characteristics, etc.) and the various systems within it (HVAC, lighting, water heating, etc.). This analysis uses a publicly available collection of commercial reference buildings (CRB), comprised of sixteen building types and three vintages (DOE-EERE 2020b; Deru et al 2011). Each building is simulated in eighteen different locations, covering a wide range of climatic conditions. The prototype building description files assign the type of HVAC equipment used, and capacities across climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Miscellaneous Electric Loads: Characterization and Energy Savings Potential

Over time, miscellaneous electric loads (MELs) are expected to increase both in magnitude and share of residential and commercial building energy consumption. This trend is most apparent in North America, but it is also occurring in Japan and Europe. However, the contribution of MELs to building energy use is not currently well understood, both because the products in this category are transforming rapidly and the definition and classification of MELs is ambiguous. This study estimated the national energy consumption of 36 MELs using best-available data and found them to comprise 12% of delivered electricity to the U.S. residential and commercial building sectors. If 26 of these MELs were replaced with the most energy-efficient product models available on the market, their energy consumption could be halved to 6% of delivered electricity. National energy models will better account for building energy consumption by incorporating the MELs data collected and analyzed for this study, leading to improved policy decisions.

Miscellaneous electric loads, Plug loads, Taxonomy↗