Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Efficiency as a Service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Procurement Options for Low Temperature Geothermal Technologies at Federal Facilities

Federal agencies are moving towards more efficient and resilient facilities by increasingly implementing energy projects in an effort to meet federally mandated goals, agency needs, and administration priorities. Low temperature geothermal technologies, which include geothermal heat pumps (GHP) and district heating systems, can contribute to meeting these goals. These technologies provide facilities with heating and cooling while reducing facility energy use and improving resilience. However, in order to implement these solutions, federal facilities must identify and execute a strategy for the procurement of these technologies. Federal facilities have successfully completed energy efficiency projects using a variety of procurement options. The purpose of this document is to provide federal agencies with a comprehensive overview of the procurement options available for low temperature geothermal technologies and other energy efficiency projects. The procurement options discussed include third-party financing mechanisms such as energy saving performance contracts (ESPCs), ESPC energy sales agreements (ESPC ESAs), and utility energy service contracts (UESCs), as well as dedicated funds in the form of federal grants and appropriated funds.

15 GEOTHERMAL ENERGY↗

An operational video data compression system for ATS and ITOS

An operational data compression system has been developed and implemented for transmission of digitized ATS and ITOS-VHRR satellite video data over the wideband communication link between the Wallops Island, Va. Command and Data Acquisition Station and the National Environmental Satellite Service at Suitland, Md. This system uses minicomputers for the coding and decoding of the data to achieve maximum flexibility together with specially designed interface equipment for greater efficiency. No loss in data quality occurs due to the compression, and, in certain cases, data is transmitted which would be otherwise unavailable due to the limited channel capacity. This paper describes the method of compression, the equipment used, and the compression results attained.

Kutz, R. L.↗

Countersink Drill

Efficient drill design for countersinking or metal drilling uses only two flutes instead of three and made of carbide instead of "high-speed" steel. Tool performance and service life increased.

Hernandez, R. J.↗

The space exploration initiative. Operational efficiency panel space-basing technology requirements

The topics covered include the following: (1) space basing technology requirements sources; (2) orbit transfer vehicle (OTV) processing heritage; (3) ground processing progression to space processing; (4) technology requirements for space based OTV servicing and maintenance; (5) design and development schedule for OTV's and OTV accommodations/ support hardware; (6) cryogenic technology test program development; (7) cryogenic propellant transfer, storage, and reliquefaction management summary; (8) propellant transfer technology analysis and ground testing; (8) OTV propellant storage depot development critical scaling relationships; (9) flight experiment options; (10) OTV maintenance; (11) automated fault detection/ isolation and system checkout summary; (12) engine replacement; (13) alternative docking operation; (14) OTV/payload integration; and (15) technology criticality and capability assessment. This document is presented in viewgraph form.

Pena, Luis R.↗

Data distribution satellite

The Data Distribution Satellite (DDS), operating in conjunction with the planned space network, the National Research and Education Network and its commercial derivatives, would play a key role in networking the emerging supercomputing facilities, national archives, academic, industrial, and government institutions. Centrally located over the United States in geostationary orbit, DDS would carry sophisticated on-board switching and make use of advanced antennas to provide an array of special services. Institutions needing continuous high data rate service would be networked together by use of a microwave switching matrix and electronically steered hopping beams. Simultaneously, DDS would use other beams and on board processing to interconnect other institutions with lesser, low rate, intermittent needs. Dedicated links to White Sands and other facilities would enable direct access to space payloads and sensor data. Intersatellite links to a second generation ATDRS, called Advanced Space Data Acquisition and Communications System (ASDACS), would eliminate one satellite hop and enhance controllability of experimental payloads by reducing path delay. Similarly, direct access would be available to the supercomputing facilities and national data archives. Economies with DDS would be derived from its ability to switch high rate facilities amongst users needed. At the same time, having a CONUS view, DDS would interconnect with any institution regardless of how remote. Whether one needed high rate service or low rate service would be immaterial. With the capability to assign resources on demand, DDS will need only carry a portion of the resources needed if dedicated facilities were used. Efficiently switching resources to users as needed, DDS would become a very feasible spacecraft, even though it would tie together the space network, the terrestrial network, remote sites, 1000's of small users, and those few who need very large data links intermittently.

Stevens, Grady H.↗

Aerodynamic Characteristics of Airfoils at High Speeds

This report deals with an experimental investigation of the aerodynamical characteristics of airfoils at high speeds. Lift, drag, and center of pressure measurements were made on six airfoils of the type used by the air service in propeller design, at speeds ranging from 550 to 1,000 feet per second. The results show a definite limit to the speed at which airfoils may efficiently be used to produce lift, the lift coefficient decreasing and the drag coefficient increasing as the speed approaches the speed of sound. The change in lift coefficient is large for thick airfoil sections (camber ratio 0.14 to 0.20) and for high angles of attack. The change is not marked for thin sections (camber ratio 0.10) at low angles of attack, for the speed range employed. At high speeds the center of pressure moves back toward the trailing edge of the airfoil as the speed increases. The results indicate that the use of tip speeds approaching the speed of sound for propellers of customary design involves a serious loss in efficiency.

Briggs, L J↗

30 GHz Commercial Satellite Receivers

NASA's research and development work in satellite communications for the past 10 years has included a major technology thrust aimed at opening the Ka frequency band to commercial exploitation. This has included the development and testing of advanced system network architectures, on-board switching and processing, multibeam and phased array antennas, and satellite and ground terminal RF and digital hardware. Development work in system hardware has focused on critical components including power amplifiers, satellite IF switch matrices, low noise receivers, baseband processors, and high data rate bandwidth efficient modems. This paper describes NASA's work in developing and testing 30 GHz low noise satellite receivers for commercial space communications uplink applications. Frequencies allotted for fixed service commercial satellite communications in the Ka band are 27.5 - 30.0 GHz for uplink transmission and 17.7 - 20.2 GHz for downlink transmission. The relatively large 2.5 GHz bandwidth lends itself to wideband, high data rate digital transmission applications.

Kerczewski, Robert J.↗

Space Resources Development: The Link Between Human Exploration and the Long-Term Commercialization of Space

In a letter to the NASA Administrator, Dan Goldin, in January of 1999, the Office of Management and Budget (OMB) stated the following . OMB recommends that NASA consider commercialization in a broader context than the more focused efforts to date on space station and space shuttle commercialization. We suggest that NASA examine architectures that take advantage of a potentially robust future commercial infrastructure that could dramatically lower the cost of future human exploration." In response to this letter, the NASA Human Exploration and Development of Space (HEDS) Enterprise launched the BEDS Technology & Commercialization Initiative (HTCI) to link technology and system development for human exploration with the commercial development of space to emphasize the "D" (Development) in BEDS. The development of technologies and capabilities to utilize space resources is the first of six primary focus areas in this program. It is clear that Space Resources Development (SRD) is key for both long-term human exploration of our solar system and to the long-term commercialization of space since: a) it provides the technologies, products, and raw materials to support efficient space transportation and in-space construction and manufacturing, and b) it provides the capabilities and infrastructure to allow outpost growth, self-sufficiency, and commercial space service and utility industry activities.

Sanders, Gerald B.↗

An evolving Mars telecommunications network to enable exploration and increase science data return

The coming decade of Mars exploration involves a variety of unique telecommunications challenges. Increasing spatial and spectral resolution of in situ science instruments drive the need for increased bandwidth. At the same time, many innovative and low-cost in situ mission concepts are enabled by energy-efficient relay communications. In response to these needs, the Mars Exploration Program has established a plan for an evolving orbital infrastructure that can provide enhancing and enabling telecommunications services to future Mars missions. We will present the evolving capabilities of this network over the coming decade in terms of specific quantitative metrics such as data volume per sol and required lander energy per Gb of returned data for representative classes of Mars exploration spacecraft.

Mars Telecommunication↗

Simulated Beam Extraction Performance Characterization of a 50-cm Ion Thruster Discharge

A 50 cm ion thruster is being developed to operate at >65 percent total efficiency at 11 kW, 2700 s Isp and over 25 kW, 4500 s Isp at a total efficiency of >75 percent. The engine is being developed to address the need for a multimode system that can provide a range of thrust-to- power to service national and commercial near-earth onboard propulsion needs such as station-keeping and orbit transfer. Operating characteristics of the 50 cm ion thruster were measured under simulated beam extraction. The discharge current distribution at the various magnet rings was measured over a range of operating conditions. The relationship between the anode current distribution and the resulting plasma uniformity and ion flux measured at the thruster exit plane is discussed. The thermal envelope will also be investigated through the monitoring of magnet temperatures over the range of discharge powers investigated. Discharge losses as a function of propellant utilization was also characterized at multiple simulated beam currents. Bulk plasma conditions such as electron temperature and electron density near engine centerline was measured over a range of operating conditions using an internal Langmuir probe. Sensitivity of discharge performance to chamber length is also discussed. This data acquired from this discharge study will be used in the refinement of a throttle table in anticipation for eventual beam extraction testing.

Foster, John E.↗

Development of an Indexing Media Filtration System for Long Duration Space Missions

The effective maintenance of air quality aboard spacecraft cabins will be vital to future human exploration missions. A key component will be the air cleaning filtration system which will need to remove a broad size range of particles including skin flakes, hair and clothing fibers, other biological matter, and particulate matter derived from material and equipment wear. In addition, during surface missions any extraterrestrial planetary dust, including dust generated by near-by ISRU equipment, which is tracked into the habitat will also need to be managed by the filtration system inside the pressurized habitat compartments. An indexing media filter system is being developed to meet the demand for long-duration missions that will result in dramatic increases in filter service life and loading capacity, and will require minimal crew involvement. These features may also benefit other closed systems, such as submarines, and remote location terrestrial installations where servicing and replacement of filter units is not practical. The filtration system consists of three stages: an inertial impactor stage, an indexing media stage, and a high-efficiency filter stage, packaged in a stacked modular cartridge configuration. Each stage will target a specific range of particle sizes that optimize the filtration and regeneration performance of the system. An 1/8th scale and full-scale prototype of the filter system have been fabricated and have been tested in the laboratory and reduced gravity environments that simulate conditions on spacecrafts, landers and habitats. Results from recent laboratory and reducegravity flight tests data will be presented.

Filtration↗

Opportunities to Implement Solutions to Achieve Remedial Action Objectives in Consideration of Stakeholder Interests - 20365

A case study in the implementation of a soils excavation and removal project conducted at a Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site (FMSS) vicinity property; an active commercial business, in a densely populated area, with significant operational, technical and, logistical constraints that were expected to limit areas that could be remediated. The United States Army Corps of Engineers-led (USACE) team successfully navigated complex overlapping stakeholder interests to achieve a more efficient and complete removal of contaminated soils and debris while minimizing unnecessary excess costs to the Government. This paper centers on FUSRAP activities at the FMSS vicinity property located at 149-151 Maywood Avenue, Maywood, Bergen County, New Jersey. For most of its FUSRAP history, this ∼109,000 square meter (27-acre) property housed a now-demolished ∼26,000 square meter (6.5-acre) warehouse operated by Sears Logistics Services, a unit of the Sears Roebuck Company (Figure 2). Sears ended its property lease and vacated the warehouse in December 2016. Given that long history and for the purposes of this paper, the property will be referred to as the 'Sears property' or simply 'the property.' The Sears property is approximately 109,000 square meters (27-acres) and is currently zoned for commercial use. The property is bound to the north and northwest by 100 West Hunter Avenue (the Stepan Company), to the northeast by 205 Maywood Avenue, to the east by Maywood Avenue, to the south by 23 West Howcroft Road, and to the west by businesses on NJ Route 17 and the NJ Route 17 roadway. Until December 2016, the property housed a warehouse and distribution center operated by Sears Logistical Services. On-site structures were demolished by the property owner in 2017. The warehouse covered the north section of the property along the Stepan Company property line. A railroad spur from the adjacent property now known as the Maywood Interim Storage Site (MISS) ended at the northeast corner of the warehouse. Wetlands were located east of the warehouse; the rest of the property was covered with paved parking lots and grassed areas. During remediation at the property, opportunities frequently arose where the project team was able to coordinate effectively with stakeholders to sequence remediation activities to facilitate removal of otherwise inaccessible soils and identify opportunities for materials reuse when supported by residual radiological and chemical levels. Some specific opportunities include: - remediating individual truck loading dock bays to maintain tenant operations; - working along a busy highway and in a utility corridor containing a 30-inch high pressure gas main; - remediating Lodi Brook and associated wetlands requiring bypass pumping and other diversionary structures to maintain local community stormwater drainage; - protecting during remediation and supporting access to facilitate tenant/owner maintenance of critical fire protection and water supply system service lines buried in contaminated soils and necessary for safe warehouse operations; and - coordinating with stakeholders to ensure non-radiological contaminants of concern for the site (unaffiliated with FUSRAP) were addressed by the responsible party in a manner that maximized benefit to all parties while supporting an efficient overall site remediation program. Once the property was vacant and the warehouse structure and radiologically non-impacted above-grade structures were demolished, the project identified an opportunity to significantly reduce the volume of waste associated with the foundation of the former warehouse, a foundation suspected of being partially constructed in radiologically contaminated soils. The project developed and implemented supplemental radiological verification survey and sampling strategies based on radiological cross-contamination risk potential with process flow-charts and screening-level based decision points; a program that classified saw-cut sections of concrete based on observed residual surface radioactivity conditions using a combination of gamma sensitive sodium-iodide scans and beta sensitive Geiger-Muller direct measurements. The proposed approach was reviewed with stakeholders with feedback, including consideration of applicable State of New Jersey Site Remediation Program criteria and guidance before implementation. Once classified, additional sampling was performed at frequencies driven by screening. The sampling methods, stockpile sampling frequencies, criteria and, approach to data evaluation were developed in consideration of existing site cleanup standards, regional background ranges, State of New Jersey radiological remediation program guidance, and specific stakeholder input With the property remediation and survey efforts nearly completed, it is relevant to examine retrospectively the objectives, assumptions and limitations in the remedial design (i.e., what was planned) versus what was able to be accomplished through effective teaming. Benefits to other environmental remediation site programs include better understanding of how to work effectively with stakeholders to achieve win-win outcomes, and approaches to site remediation, waste minimization and materials reuse that were successful in their overall outcomes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Why is it still too warm or cold in my house? Examining the relationships between energy efficient capital and household energy insecurity

Here, this paper examines the relationships between energy efficient (EE) capital technology and household energy insecurity in the United States. The theoretical model of these relationships employs household production theory to capture the demand for and production of household energy services, and a stochastic production frontier approach to describe how having access to and the usage intensity of EE capital technology could help alleviate inefficiency in the production of household energy services. A working hypothesis formulated from the theoretical model posits that having EE capital technology in the home will reduce the level of household energy insecurity experienced. The extent of energy insecurity experienced is inferred from an energy insecurity index value assigned to each household, generated via the application of a dichotomous Rasch model to questions contained in the 2015 Residential Energy Consumption Survey. Noting the potential simultaneous relationship that exists between a household having access to and the usage intensity of EE capital technology and the experience of being energy insecure, an instrumental variables approach was employed to estimate a series of ordered logit models. Results suggest access to EE capital technology in the form of Energy Star® appliances, Energy Star® windows, or a SMART thermostat does not reduce the probability of experiencing a greater level of energy insecurity. Nor does the usage intensity of EE capital. Thus, policy instruments designed to alleviate household energy insecurity may need to go beyond simply helping households obtain EE capital technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utility-Scale Operational Consequences for Solar Grid Services

This report delves into the critical aspects of grid services provided by solar inverter-based resources (IBRs), with an emphasis on the evolving landscape of microgrids, virtual power plants (VPPs), aggregators, and distributed energy resource management systems (DERMS). As the energy sector undergoes a transformative shift towards more decentralized and resilient grid architectures, understanding the multifaceted risks associated with these technologies becomes paramount. The report categorizes these risks into organizational, technical, and procedural domains, providing a thorough risk assessment framework that stakeholders can utilize to anticipate and mitigate potential issues. In addressing the increasing complexity of grid interconnections, the report highlights the importance of Cyber-Informed Engineering (CIE). By embedding engineering controls and cybersecurity measures into the early stages of system design, this approach aims to fortify grid infrastructure against emerging cyber threats. The analysis includes an exploration of best practices and strategies for integrating CIE principles to enhance grid security and resilience. To provide practical insights, the report conducts a detailed consequence analysis of various grid services and cyber mitigations that can be applied through the interconnection process. This analysis evaluates the potential impacts of different failure modes and vulnerabilities, offering a clear understanding of the consequences that could arise from disruptions within the energy grid. The findings are further enriched by a series of case studies that illustrate real-world scenarios and lessons learned from past incidents. Through this comprehensive examination of grid services and their criticality, the report aims to prepare industry professionals with the knowledge and tools necessary to navigate the complexities of modern energy systems. By providing a comprehensive approach that includes risk assessment, cybersecurity, and consequence analysis, solar stakeholders can more effectively guarantee the reliability, efficiency, and security of the energy grid.

14 SOLAR ENERGY↗

Grid ancillary services using electrolyzer-Based power-to-Gas systems with increasing renewable penetration

Increasing penetrations of renewable-based generation have led to a decrease in the bulk power system inertia and an increase in intermittency and uncertainty in generation. Energy storage is considered to be an important factor to help manage renewable energy generation at greater penetrations. Hydrogen is a viable long-term storage alternative. This paper analyzes and presents use cases for leveraging electrolyzer-based power-to-gas systems for electric grid support. The paper also discusses some grid services that may favor the use of hydrogen-based storage over other forms such as battery energy storage. Real-time controls are developed, implemented and demonstrated using a power-hardware-in-the-loop(PHIL) setup with a 225-kW proton-exchange-membrane electrolyzer stack. These controls demonstrate frequency and voltage support for the grid for different levels of renewable penetration (0%, 25%, and 50%). A comparison of the results shows the changes in respective frequencies and voltages as seen as different buses as a result of support from the electrolyzers and notes the impact on hydrogen production as a result of grid support. Finally, the paper discusses the practical nuances of implementing the tests with physical hardware, such as inverter/electrolyzer efficiency, as well as the related constraints and opportunities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radiological HEPA Filter 10-year Lifetime Evaluation in Research Facilities

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifetime deployment and its other performance indicators. This 10-year-long endeavor to collect and analyze data regarding the service life of HEPA filters at the Pacific Northwest National Laboratory began in 2010. A set of HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. The study has now been completed, and over the past decade all the HEPA filters have been replaced, due to either technical issues as listed in this report or the previously recommended filter “age limit” of 10 years as prescribed by the oversight bodies. Experimentally determined failure rates are also determined from the data set and can be used to estimate the chances of HEPA filters surviving 15, 20, or even 30 years.

61 RADIATION PROTECTION AND DOSIMETRY↗

Guest Editorial Special Issue on Emerging Topics of Power Electronics Interfaced Battery Energy Storage System

No doubt, battery energy storage systems have been the enabling solution to balance generation and consumption of power systems with high-penetration renewable energy resources, long-range electric vehicles, and various smart devices. Upon the battery has been manufactured, the rest of implementation issues become how to interface battery and related systems, how to regulate the charging/discharging power, and how to keep battery energy storage systems (BESSs) safe, reliable, and long-term service. In this editorial, we discuss how power electronic converters and associated control and optimization, which can maximize the value of BESSs, are devoted to provide cost-effective, efficient, and even revolutionary technologies.

25 ENERGY STORAGE↗

Updated Report for the Natural Gas Community of the Future

Nicor Gas is developing the Natural Gas Community of the Future (later renamed the Nicor Gas Smart Neighborhood (TM), a high-performance residential neighborhood consisting of 50 homes connected to electricity and natural gas services in suburban South Chicago , built as low-income affordable housing. The National Renewable Energy Laboratory (NREL) has been assisting Nicor Gas to explore a synergy among energy efficiency, renewable technologies, affordability, and resilience enabled by natural gas in this community. Our goal is to demonstrate how energy efficiency, distributed energy resources (DERs), and advanced controls, in combination with existing natural gas and electricity infrastructure, can help historically underserved communities in a cold climate reduce energy burden and improve resilience to extreme weather conditions.

03 NATURAL GAS↗