Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

THE TWO-PHASE, TWO-VELOCITY IONIZED ABSORBER IN THE SEYFERT 1 GALAXY NGC 5548

We present an analysis of X-ray high-quality grating spectra of the Seyfert 1 galaxy NGC 5548 using archival Chandra-High Energy Transmission Grating Spectrometer and Low Energy Transmission Grating Spectrometer observations for a total exposure time of 800 ks. The continuum emission (between 0.2 keV and 8 keV) is well represented by a power law (GAMMA = 1.6) plus a blackbody component (kT = 0.1 keV). We find that the well-known X-ray warm absorber (WA) in this source consists of two different outflow velocity systems. One absorbing system has a velocity of -1110 +- 150 km s{sup -1} and the other of -490 +- 150 km s{sup -1}. Recognizing the presence of these kinematically distinct components allows each system to be fitted independently, each with two absorption components with different ionization levels. The high-velocity system consists of two components, one with a temperature of 2.7 +- 0.6 x 10{sup 6} K, log U = 1.23, and another with a temperature of 5.8 +- 1.0 x 10{sup 5} K, log U = 0.67. The high-velocity, high-ionization component produces absorption by charge states Fe XXI-XXIV, while the high-velocity, low-ionization component produces absorption by Ne IX-X, Fe XVII-XX, and O VII-VIII. The low-velocity system also required two absorbing components, one with a temperature of 5.8 +- 0.8 x 10{sup 5} K, log U = 0.67, producing absorption by Ne IX-X, Fe XVII-XX, and O VII-VIII, and the other with a lower temperature of 3.5 +- 0.35 x 10{sup 4} K and a lower ionization of log U = -0.49, producing absorption by O VI-VII and the Fe VII-XII M-shell Unresolved Transitions Array. Once these components are considered, the data do not require any further absorbers. In particular, a model consisting of a continuous radial range of ionization structures (as suggested by a previous analysis) is not required. The two absorbing components in each velocity system are in pressure equilibrium with each other. This suggests that each velocity system consists of a multi-phase medium. This is the first time that different outflow velocity systems have been modeled independently in the X-ray band for this source. The kinematic components and column densities found from the X-rays are in agreement with the main kinematic components found in the UV absorber. This supports the idea that the UV and X-ray absorbing gas is part of the same phenomenon. NGC 5548 can now be seen to fit in a pattern established for other WAs: two or three discrete phases in pressure equilibrium. There are no remaining cases of a well-studied WA in which a model consisting of a multi-phase medium is not viable.

79 ASTRONOMY AND ASTROPHYSICS↗

PRODUCTION OF HIGH-TEMPERATURE PLASMAS DURING THE EARLY PHASES OF A C9.7 FLARE

Explosive chromospheric evaporation is predicted from some current solar flare models. In this paper, we analyze a flare with high time cadence raster scans with the EUV Imaging Spectrometer (EIS) on board the Hinode spacecraft. This observation covers an area of 240'' x 240'', with the 1'' slit in about 160 s. The early phases of a C9.7 flare that occurred on 2007 June 6 were well observed. The purpose of our analysis is to study for the first time the spatially resolved spectra of high-temperature plasma, especially from Fe XXIII and Fe XXIV, allowing us to explore the explosive chromospheric evaporation scenario further. Sections of raster images obtained between 17:20:09 and 17:20:29 (UT) show a few bright patches of emission from Fe XXIII/Fe XXIV lines at the footpoints of the flaring loops; these footpoints were not clearly seen in the images taken earlier, between 17:17:30 and 17:17:49 (UT). Fe XXIII spectra at these footpoints show dominating blueshifted components of -(300 to 400) km s{sup -1}, while Fe XV/XIV lines are nearly stationary; Fe XII lines and/or lower temperature lines show slightly redshifted features, and Fe VIII and Si VII to He II lines show {approx}+50 km s{sup -1} redshifted components. The density of the 1.5-2 MK plasma at these footpoints is estimated to be 3 x 10{sup 10} cm{sup -3} by the Fe XIII/XIV line pairs around the maximum of the flare. High-temperature loops connecting the footpoints appear in the Fe XXIII/XXIV images taken over 17:22:49-17:23:08 (UT) which is near the flare peak. Line profiles of these high-temperature lines at this flare peak time show only slowly moving components. The concurrent cooler Fe XVII line at 254.8 A is relatively weak, indicating the predominance of high-temperature plasma (>10{sup 7} K) in these loops. The characteristics observed during the early phases of this flare are consistent with the scenario of explosive chromospheric evaporation.

79 ASTRONOMY AND ASTROPHYSICS↗

AN INTRODUCTION TO THE CHANDRA CARINA COMPLEX PROJECT

The Great Nebula in Carina provides an exceptional view into the violent massive star formation and feedback that typifies giant H II regions and starburst galaxies. We have mapped the Carina star-forming complex in X-rays, using archival Chandra data and a mosaic of 20 new 60 ks pointings using the Chandra X-ray Observatory's Advanced CCD Imaging Spectrometer, as a testbed for understanding recent and ongoing star formation and to probe Carina's regions of bright diffuse X-ray emission. This study has yielded a catalog of properties of >14,000 X-ray point sources; >9800 of them have multiwavelength counterparts. Using Chandra's unsurpassed X-ray spatial resolution, we have separated these point sources from the extensive, spatially-complex diffuse emission that pervades the region; X-ray properties of this diffuse emission suggest that it traces feedback from Carina's massive stars. In this introductory paper, we motivate the survey design, describe the Chandra observations, and present some simple results, providing a foundation for the 15 papers that follow in this special issue and that present detailed catalogs, methods, and science results.

79 ASTRONOMY AND ASTROPHYSICS↗

FIRST SPECTROSCOPIC IMAGING OBSERVATIONS OF THE SUN AT LOW RADIO FREQUENCIES WITH THE MURCHISON WIDEFIELD ARRAY PROTOTYPE

We present the first spectroscopic images of solar radio transients from the prototype for the Murchison Widefield Array, observed on 2010 March 27. Our observations span the instantaneous frequency band 170.9- 201.6 MHz. Though our observing period is characterized as a period of 'low' to 'medium' activity, one broadband emission feature and numerous short-lived, narrowband, non-thermal emission features are evident. Our data represent a significant advance in low radio frequency solar imaging, enabling us to follow the spatial, spectral, and temporal evolution of events simultaneously and in unprecedented detail. The rich variety of features seen here reaffirms the coronal diagnostic capability of low radio frequency emission and provides an early glimpse of the nature of radio observations that will become available as the next generation of low-frequency radio interferometers come online over the next few years.

79 ASTRONOMY AND ASTROPHYSICS↗

γ decay from the quasicontinuum of 197,198 Au

Here, the average electromagnetic dipole response of levels in the quasicontinuum of 197,198 Au has been measured using ( 3 He, 3 He') and (d,p) reactions. The extracted γ-ray strength functions have been normalized according to three model assumptions for the nuclear spin distribution. An enhancement in the energy region E γ = 3.0–6.5 MeV is observed for both isotopes. The E1 component of such excess of strength is studied in detail for 198 Au and is interpreted as the pygmy dipole resonance with an energy centroid of 5.9(1) MeV and exhausts about 1% of the total integrated strength. The pygmy dipole resonance is shown to have a significant impact on the calculated 197 Au(n,γ) 198 Au cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-Ray Nanointerferometer Based on Si Refractive Bilenses

We report a novel type of x-ray interferometer employing a bilens system consisting of two parallel compound refractive lenses, each of which creates a diffraction limited beam under coherent illumination. By closely overlapping such coherent beams, an interference field with a fringe spacing ranging from tens of nanometers to tens of micrometers is produced. In an experiment performed with 12 keV x rays, submicron fringes were observed by scanning and moire imaging of the test grid. The far field interference pattern was used to characterize the x-ray coherence. Our technique opens up new opportunities for studying natural and man-made nanoscale materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Statistics Measurement of Neutrino Quasielasticlike Scattering at 6 GeV on a Hydrocarbon Target

We measure neutrino charged-current quasielasticlike scattering on hydrocarbon at high statistics using the wideband Neutrinos at the Main Injector beam with neutrino energy peaked at 6 GeV. The double-differential cross section is reported in terms of muon longitudinal ( p ∥ ) and transverse ( p ⊥ ) momentum. Cross section contours versus lepton momentum components are approximately described by a conventional generator-based simulation, however, discrepancies are observed for transverse momenta above 0.5 GeV / c for longitudinal momentum ranges 3–5 and 9 – 20 GeV / c . The single differential cross section versus momentum transfer squared ( d σ / d Q QE 2 ) is measured over a four-decade range of Q 2 that extends to 10 GeV 2 . The cross section turnover and falloff in the Q 2 range 0.3 – 10 GeV 2 is not fully reproduced by generator predictions that rely on dipole form factors. Our measurement probes the axial-vector content of the hadronic current and complements the electromagnetic form factor data obtained using electron-nucleon elastic scattering. These results help oscillation experiments because they probe the importance of various correlations and final-state interaction effects within the nucleus, which have different effects on the visible energy in detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton Compton Scattering from Linearly Polarized Gamma Rays

In this work, differential cross sections for Compton scattering from the proton have been measured at scattering angles of 55°, 90°, and 125° in the laboratory frame using quasimonoenergetic linearly (circularly) polarized photon beams with a weighted mean energy value of 83.4 MeV (81.3 MeV). These measurements were performed at the High Intensity Gamma-Ray Source facility at the Triangle Universities Nuclear Laboratory. The results are compared to previous measurements and are interpreted in the chiral effective field theory framework to extract the electromagnetic dipole polarizabilities of the proton, which gives $α^p_{E1} = 13.8 ± 1.2_{\text{stat}} ± 0.1_{\text{BSR}} ± 0. 3_{\text{theo}} , β^p_{M1} = 0.2 ∓ 1. 2_{\text{stat}} ± 0. 1_{\text{BSR}} ∓ 0. 3_{\text{theo}}$ in units of $10^{–4}$ fm$^3$ .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-F-I-69: Absorbed Dose Estimation for a Commercially Available MicroCT Scanner with Various Filtration Techniques

Purpose: To quantify the simulated mean absorbed dose per technique (cGy/mAs) from a commercially available microCT scanner using various filtration techniques. Methods: Monte Carlo simulations using the Geant4 toolkit (version 10) was used utilizing the standard electromagnetic physics model. The Quantum FX microCT scanner (PerkinElmer, Waltham, MA) was modeled incorporating measured energy spectra and spatial dimensions of nominal source-to-object (SOD) distances. The energy distribution was measured using a spectrometer (X-123CdTe, Amptek Inc., Bedford, USA) for the 90 kVp X-ray beams with various filters (including no filter, 1 mm, 2 mm, 3 mm, 4 mm Al and 0.2 mm Cu + 2.5 mm Al). The SOD was set to 154 mm, 104 mm, and 52 mm. A total of 10 million incident particles were processed per simulation. Cutout value was set to 0.1 mm for both photon and electron. The mean dose absorbed (cGy/per incident particle) in a PMMA phantom (length of 2 cm and radius of 3 cm) were recorded. Exposure measurements were taken using a Radcal 9095 system with a protocol of 90 kVp, 200 µA, and ∼12 s beam-On time for the various filters. Results: The mean absorbed dose per mAs for various filtrations and different SOD setups indicated that the dose decreased as the SOD increased and as the amount of filtration increased. For a given SOD, the dose was reduced by as much as ∼13.7% by varying the filter (from 0.2 mm Cu + 2.5 mm Al to no filter). The maximum dose was found to be 0.39 cGy/mAs (SOD of 5.196 cm, no filter) while the minimum dose value was 0.077 cGy/mAs (SOD of 15.4 cm, .2mm Cu + 2mm Al filter). Conclusion: This study estimates easily the mean dose for objects scanned with a microCT scanner with different filtration.

60 APPLIED LIFE SCIENCES↗

Potential Constraints to Neutrino-Nucleus Interactions Based on Electron Scattering Data

A thorough understanding of neutrino-nucleus interactions physics is crucial to achieving precision goals in broader neutrino physics programs. The complexity of nuclei comprising the detectors and limited understanding of their weak response constitutes one of the biggest systematic uncertainties in neutrino experiments - both at intermediate energies affecting the short- and long-baseline neutrino programs as well as at lower energies affecting coherent scattering neutrino programs. While electron and neutrino interactions are different at the primary vertex, many underlying relevant physical processes in the nucleus are the same in both cases, and electron scattering data collected with precisely controlled kinematics, large statistics and high precision allows one to constrain nuclear properties and specific interaction processes. To this end, electron-nucleus scattering experiments provide vital complementary information to test, assess and validate different nuclear models and event generators intended to be used in neutrino experiments. In fact, for many decades, the study of electron scattering off a nucleus has been used as a tool to probe the properties of that nucleus and its electromagnetic response. While previously existing electron scattering data provide important information, new and proposed measurements are tied closely to what is required for the neutrino program in terms of expanding kinematic reach, the addition of relevant nuclei and information on the final states hadronic system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radar detection of radiation-induced ionization in air

A millimeter wave measurement system has been developed for remote detection of airborne nuclear radiation, based on electromagnetic scattering from radiation-induced ionization in air. Specifically, methods of monitoring radiation-induced ionization of air have been investigated, and the ionized air has been identified as a source of millimeter wave radar reflection, which can be utilized to determine the size and strength of a radiation source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold cavity analysis for 35 GHz gyrotron interaction cavity using free space method

The interaction cavity simulated, designed and fabricated for the 35 GHz gyrotron is verified experimentally. Free space method for the Q value and resonant frequency measurement is used in the experiments. The WR22 waveguide based antenna system, Agilent Vector Network Analyzer are used as the experimental set-up in the cavity measurement. The simulation results for the same cavity are also obtained by using the electromagnetic simulator MAGIC for the comparison. (author)

43 PARTICLE ACCELERATORS↗

Methods and systems for electromagnetic near-field coherent sensing

The present disclosure may be embodied as methods and/or systems for non-contact measuring of an on-body and/or inside-body motion of an individual. A sensing signal is provided within a near-field coupling range of a motion to be measured. In this way, a measurement signal may be generated as the sensing signal modulated by the motion. The sensing signal may be an ID-modulated signal. In some embodiments, the sensing signal is a backscattered RFID link provided a wireless tag. A downlink signal may be provided to power the wireless tag. The sensing signal may be a harmonic of the downlink signal. The measurement signal is detected. The motion is measured based on the measurement signal. The measurement signal may be detected as far-field radiation after transmission through a source of the motion. The measurement signal may be detected as reflected from a source of the motion as antenna reflection.

Hui, Xiaonan↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Achieving a near-ideal silicon crystal neutron interferometer using submicrometer fabrication techniques

Perfect-crystal neutron interferometry, which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two-step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, nonetching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution. Published by the American Physical Society 2024

Huber, M. G. (ORCID:0000000237958445)↗

ON THE NATURE OF THE COMPACT OBJECT IN SS 433: OBSERVATIONAL EVIDENCE OF X-RAY PHOTON INDEX SATURATION

We present an analysis of the X-ray spectral properties observed from the black hole candidate (BHC) binary SS 433. We have analyzed Rossi X-ray Timing Explorer data from this source, coordinated with Green Bank Interferometer/RATAN-600. We show that SS 433 undergoes an X-ray spectral transition from the low hard state to the intermediate state (IS). We show that the X-ray broadband energy spectra during all spectral states are well fitted by a sum of the so-called bulk motion Comptonization (BMC) component and by two (broad and narrow) Gaussians for the continuum and line emissions, respectively. In addition to these spectral model components, we also find a strong feature that we identify as a 'blackbody-like (BB)' component in which the color temperature is in the range of 4-5 keV in 24 IS spectra during the radio outburst decay in SS 433. Our observational results on the 'high-temperature BB' bump lead us to suggest the presence of gravitationally redshifted annihilation line emission in this source. In fact, this spectral feature has been recently reproduced in Monte Carlo simulations by Laurent and Titarchuk. We have also established the photon index saturation at about 2.3 in index versus mass accretion correlation. This index-mass accretion correlation allows us to evaluate the low limit of the black hole (BH) mass of the compact object in SS 433, M{sub bh{approx}}>2 solar masses, using the scaling method using BHC GX 339 - 4 as a reference source. Our estimate of the BH mass in SS 433 is consistent with the recent BH mass measurement using the radial velocity measurements of the binary system by Hillwig and Gies, who find that M{sub x} = (4.3 {+-} 0.8) solar masses. This is the smallest BH mass found up to now among all BH sources. Moreover, the index saturation effect versus mass accretion rate revealed in SS 433, as in a number of other BH candidates, is strong observational evidence for the presence of a BH in SS 433.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic ray propagation time scales: lessons from radioactive nuclei and positron data

We take a fresh look at high energy radioactive nuclei data reported in the 90's and at the positron data recently reported by PAMELA. Our aim is to study the model independent implications of these data for the propagation time scales of cosmic rays in the Galaxy. Considering radioactive nuclei, using decaying charge to decayed charge ratios — the only directly relevant data available at relativistic energies — we show that a rigidity independent residence time is consistent with observations. The data for all nuclei can be described by f{sub s,i} = (t{sub i}/100 Myr){sup 0.7}, where f{sub s,i} is the suppression of the flux due to decay and t{sub i} is the observer frame lifetime for nucleus specie i. Considering positron measurements, we argue that the positron flux is consistent with a secondary origin. Comparing the positron data with radioactive nuclei at the same energy range, we derive an upper bound on the mean electromagnetic energy density traversed by the positrons, U-bar {sub T} < 1.25 eV/cm{sup 3} at a rigidity of R = 40 GV. Charge ratio measurements within easy reach of the AMS-02 experiment, most notably a determination of the Cl/Ar ratio extending up to R ∼ 100 GV, will constrain the energy dependence of the positron cooling time. Such constraints can be used to distinguish between different propagation scenarios, as well as to test the secondary origin hypothesis for the positrons in detail.

79 ASTRONOMY AND ASTROPHYSICS↗