Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Gravitational waves from first order phase transitions during inflation

We study the production, spectrum, and detectability of gravitational waves in models of the early Universe where first order phase transitions occur during inflation. We consider all relevant sources. The self-consistency of the scenario strongly affects the features of the waves. The spectrum appears to be mainly sourced by collisions of bubble of the new phases, while plasma dynamics (turbulence) and the primordial gauge fields connected to the physics of the transitions are generally subdominant. The amplitude and frequency dependence of the spectrum for modes that exit the horizon during inflation are different from those of the waves produced by quantum vacuum oscillations of the metric or by first order phase transitions not occurring during inflation. A not too large number of slow (but still successful) phase transitions can leave detectable marks in the common microwave background radiation, but the signal weakens rapidly for faster transitions. When the number of phase transitions is instead large, the primordial gravitational waves can be observed both in the common microwave background radiation or with LISA (but in this case only marginally, for the slowest transitions) and especially with DECIGO. We also discuss the nucleosynthesis bound and the constraints it places on the parameters of the models.

79 ASTRONOMY AND ASTROPHYSICS↗

Cryptotomography: Reconstructing 3D Fourier Intensities from Randomly Oriented Single-Shot Diffraction Patterns

We reconstructed the 3D Fourier intensity distribution of monodisperse prolate nanoparticles using single-shot 2D coherent diffraction patterns collected at DESY's FLASH facility when a bright, coherent, ultrafast x-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the expansion-maximization-compression framework to accommodate unmeasured fluctuations in photon fluence and loss of data due to saturation or background scatter. This work is an important step towards realizing single-shot diffraction imaging of single biomolecules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Yield Nuclear Monitoring Physics Experiment 1 – Integrated Data Acquisition System Design and Initial Observations

The report documents the design of the Integrated Data AcQuisition (IDAQ) system and observations recorded during the first in a series of underground chemical explosions conducted on the Nevada National Security Site (NNSS) in southern Nevada. Experiments are funded as part of Low Yield Nuclear Monitoring (LYNM) research and development within the United States National Nuclear Security Administration NA-22 nuclear non-proliferation program. The series is part of the broader Physical Experiment 1 (PE1) being conducted in and around the P-tunnel facility on the NNSS. Each explosive experiment utilizes several tons of comp-B to generate signals recorded by a broad suite of instrumentation. The IDAQ serves as the backbone for all subsurface instrumentation providing precise time synchronization, remote control, data exfiltration and backup, along with recording several sensing modalities throughout the underground complex that includes ground motion, environmental conditions, and electromagnetic signals.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Prospects for high accuracy time dissemination and synchronization using coded radar pulses from a low-earth orbiting spacecraft

The radar (an acronym for radio detection and ranging) is an instrument developed just before the WW-II to precisely measure the position of an object (target) in space. This is done by emitting a narrow pulse of electromagnetic energy in the RF spectrum, receiving the return echo and measuring the time of flight in the two-way path from the emitter to the target. The propagation delay provides a measure of the range to the target, which is not in itself sufficient to uniquely locate the position of the same in space. However, if a directional antenna is used, the direction of the echo can be assessed by the antenna pointing angles. In this way the position of the target can be uniquely determined in space. How well this can be done is a function of the resolution of the measurements performed (range and direction, i.e.: angles); in turn, the resolution will dictate the time and frequency requirements of the reference oscillator.

Detoma, Edoardo V.↗

Symmetric Waveguide Orthomode Junctions

Imaging applications at millimeter and submillimeter wavelengths demand precise characterization of the amplitude, spectrum, and polarization of the electromagnetic radiation. The use of a waveguide orthomode transducer (OMT) can help achieve these goals by increasing spectral coverage and sensitivity while reducing exit aperture size, optical spill, instrumental polarization offsets, and lending itself to integration in focal plane arrays. For these reasons, four-fold symmetric OMTs are favored over a traditional quasi-optical wire grid for focal plane imaging arrays from a systems perspective. The design, fabrication, and test of OMTs realized with conventional split-block techniques for millimeter wave-bands are described. The design provides a return loss is -20 dB over a full waveguide band (40% bandwidth), and the cross-polarization and isolation are greater than -40 dB for tolerances readily achievable in practice. Prototype examples realized in WR10.0 and WR3.7 wavebands will be considered in detail.

Wollack, E. J.↗

Symmetric Waveguide Orthomode Junctions

Imaging applications at millimeter and submillimeter wavelengths demand precise characterization of the amplitude, spectrum, and polarization of the electromagnetic radiation. The use of a waveguide orthomode transducer (OMT) can help achieve these goals by increasing spectral coverage and sensitivity while reducing exit aperture size, optical spill, instrumental polarization offsets, and lending itself to integration in focal plane arrays. For these reasons, four-old symmetric OMTs are favored over a traditional quasi-optical wire grid for focal plane imaging arrays from a systems perspective. The design, fabrication, and test of OMTs realized with conventional split-block techniques for millimeter wave-bands are described. The design provides a return loss is -20 dB over a full waveguide band (40% bandwidth), and the cross-polarization and isolation are greater than -40 dB for tolerances readily achievable in practice. Prototype examples realized in WR10.0 and WR3.7 wavebands will be considered in detail.

Wollack, E. J.↗

Measurements of the Electron Cloud Density in the PEP-II Low Energy Ring

Clouds of low energy electrons in the vacuum beam pipes of accelerators of positively charged particle beams present a serious limitation for operation of these machines at high currents. Because of the size of these accelerators, it is difficult to probe the low energy electron clouds over substantial lengths of the beam pipe. We have developed a novel technique to directly measure the electron cloud density via the phase shift induced in a TE wave that is independently excited and transmitted over a section of the accelerator. We infer the absolute phase shift with relatively high accuracy from the phase modulation of the transmission due to the modulation of the electron cloud density from a gap in the positively charged beam. We have used this technique for the first time to measure the average electron cloud density over a 50 m straight section in the positron ring of the PEP-II collider at the Stanford Linear Accelerator Center. We have also measured the variation of the density by using low field solenoid magnets to control the electrons.

43 PARTICLE ACCELERATORS↗

RADIATIVE HEATING OF THE SOLAR CORONA

We investigate the effect of solar visible and infrared radiation on electrons in the Sun's atmosphere using a Monte Carlo simulation of the wave-particle interaction and conclude that sunlight provides at least 40% and possibly all of the power required to heat the corona, with the exception of dense magnetic flux loops. The simulation uses a radiation waveform comprising 100 frequency components spanning the solar blackbody spectrum. Coronal electrons are heated in a stochastic manner by low coherence solar electromagnetic radiation. The wave 'coherence time' and 'coherence volume' for each component is determined from optical theory. The low coherence of solar radiation allows moving electrons to gain energy from the chaotic wave field which imparts multiple random velocity 'kicks' to these particles causing their velocity distribution to broaden or heat. Monte Carlo simulations of broadband solar radiative heating on ensembles of 1000 electrons show heating at per particle levels of 4.0 x 10{sup -21} to 4.0 x 10{sup -20} W, as compared with non-loop radiative loss rates of {approx}1 x 10{sup -20} W per electron. Since radiative losses comprise nearly all of the power losses in the corona, sunlight alone can explain the elevated temperatures in this region. The volume electron heating rate is proportional to density, and protons are assumed to be heated either by plasma waves or through collisions with electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Of Gas Electron Multiplier (GEM) Detector Characteristics

The High Energy Physics group of the University of Texas at Arlington has been developing gas electron multiplier detectors to use them as sensitive gap detectors in digital hadron calorimeters for the International Linear Collider, a future high energy particle accelerator. For this purpose, we constructed numerous GEM detectors that employ double GEM layers. In this study, two kinds of prototype GEM detectors were tested; one with 28x28 cm{sup 2} active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap and the other with two 3x3 cm{sup 2} GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. The detectors' characteristics from exposure to high-energy charged particles and other radiations were measured using cosmic rays and {sup 55}Fe radioactive source. From the {sup 55}Fe tests, we observed two well separated characteristic X-ray emission peaks and confirmed the detectors' functionality. We also measured chamber gains to be over 6000 at a high voltage of 395 V across each GEM electrode. The responses to cosmic rays show the spectra that fit well to Landau distributions as expected from minimum ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the Accuracy and Consistency of Cloud Property Retrievals from Passive Radiometers with Varying Spectral Information

Over the past few decades, space-based passive radiometers have been used to study the spatial distribution of clouds and some of their basic properties. Modern radiometers have significantly higher spatial resolution and collect more spectral information (i.e., have more spectral bands) than early instruments, and these advances have allowed researchers to characterize cloud physical and microphysical properties with greater detail. There is significant interest in utilizing as much of the existing satellite record as possible to study global and regional changes in cloud occurrence and distribution as well as the associated changes in reflected shortwave and outgoing longwave fluxes. Cloud property retrieval algorithms such as the NASA Satellite Cloud Optical and Radiative Property System (SatCORPS) have traditionally utilized as much spectral information as possible in order to maximize the accuracy of the retrievals. However, changes to the retrieval algorithm over time in order to take advantage of progressively more spectral information results in inconsistencies in cloud properties which in turn results in inconsistencies with products derived from these properties. It is not possible to implement modern state-of-the-art algorithms to earlier instruments which lack diverse spectral information, but many instruments since the early 2000s generally have approximately similar spectral bands in the visible (~0.65 microns), longwave infrared (~11 microns), and in many cases, the midwave infrared (~3.8 microns) and water vapor absorption (~6.7 microns), portions of the electromagnetic spectrum. Different versions of SatCORPS have been implemented with either the full set of spectral information collected by imagers such as GOES-16 and MODIS or with a reduced set of spectral bands in order to be more consistent with past imagers that lack such diverse spectral information. This study uses independent cloud property retrievals from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) to assess the accuracy of the retrievals (e.g., cloud fraction, thermodynamic phase, altitude) from the different retrieval methods and to demonstrate the advantages and disadvantages of using a reduced set of common spectral bands in order to achieve temporal and spatial consistency across different instruments.

Christopher R. Yost↗

Development of an ion beam analyzing system for the KBSI heavy-ion accelerator

The Korea Basic Science Institute (KBSI) has been developing a heavy ion accelerator system to accelerate high current, multi-charge state ions produced by a 28 GHz superconducting electron cyclotron ion source. A beam analyzing system as a part of the low energy beam transport apparatus was developed to select charged particles with desirable charge states from the ion beams. The desired species of ion, which is generated and extracted from the ECR ion source including various ion particles, can be selected by 90° dipole electromagnet. Due to the non-symmetrical structure in the coil as well as the non-linear permeability of the yoke material coil, a three dimensional analysis was carried out to confirm the design parameters. In this paper, we present the experimental results obtained as result of an analysis of KBSI accelerator. The effectiveness of beam selection was confirmed during the test of the analyzing system by injecting an ion beam from an ECR ion source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of electromagnetic simulation capabilities in global gyrokinetic particle-in-cell code GTS

Recently, the numerical scheme presented by Mishchenko et al. enabled explicit gyrokinetic simulations of low-frequency electromagnetic instabilities in tokamaks at experimentally relevant values of plasma β⁠. This scheme resolved the long-standing cancellation problem that previously hindered gyrokinetic particle-in-cell code simulations of magnetohydrodynamic phenomena with inherently small parallel electric fields. Moreover, the scheme did not employ approximations that eliminate critical tearing-type instabilities. Here, we report on the implementation of this numerical scheme in the global gyrokinetic particle-in-cell code GTS. This implementation allows for a more complete and accurate picture of interaction between small scale turbulence and MHD modes in tokamaks. Additionally, we present a comprehensive set of verification simulations of numerous electromagnetic instabilities relevant to present-day tokamaks. These simulations encompass the kinetic ballooning mode, the internal kink mode, the tearing mode, the micro-tearing mode, and the toroidal Alfven eigenmode destabilized by energetic ions, which are all instrumental in understanding tokamak physics. We will also showcase the preliminary nonlinear simulations of kinetic ballooning instabilities and (2,1) island formation due to tearing mode instability. These simulations validate the accuracy of the scheme implementation and pave the way for studying how these instabilities affect plasma confinement and performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Muon energy reconstruction for applications in neutrino astronomy in the DUNE far detector

Abstract DUNE (Deep Underground Neutrino Experiment) is a proposed long-baseline neutrino oscillation experiment located in the United States. The main physics objectives of DUNE are to measure neutrino oscillations and interactions, search for nucleon decay, observe supernova neutrino bursts and beyond Standard Model (BSM) effects. The DUNE far detector will be located 4850 feet underground at the Sanford Underground Research Facility in Lead, South Dakota. It will house the world's largest liquid-argon time projection chambers (TPC). The DUNE far detector can detect high-energy leptons that arise from interactions of cosmogenic neutrinos and search for neutrinos originating from the decay of weakly-interactive massive particles (WIMPs) annihilations occurring inside the Sun. Selecting upward-going muons reduces the background from cosmic-ray muons. The muon energy is estimated from the electromagnetic showers accompanying the muon, a technique that allows energy reconstruction up to a few hundred TeV.

Instruments & Instrumentation↗

Circularly polarized antennas for active holographic imaging through barriers

Circularly-polarized antennas and their methods of use for active holographic imaging through barriers. The antennas are dielectrically loaded to optimally match the dielectric constant of the barrier through which images are to be produced. The dielectric loading helps to remove barrier-front surface reflections and to couple electromagnetic energy into the barrier.

47 OTHER INSTRUMENTATION↗

A MULTIPHASE SUZAKU STUDY OF X-RAYS FROM {tau} Sco

We obtained relatively high signal-to-noise X-ray spectral data of the early massive star {tau} Sco (B0.2V) with the Suzaku X-ray Imaging Spectrometer (XIS) instrument. This source displays several unusual features that motivated our study: (1) redshifted absorption in UV P Cygni lines to approximately +250 km s{sup -1} suggestive of infalling gas, (2) unusually hard X-ray emission requiring hot plasma at temperatures in excess of 10 MK whereas most massive stars show relatively soft X-rays at a few MK, and (3) a complex photospheric magnetic field of open and closed field lines. In an attempt to understand the hard component better, X-ray data were obtained at six roughly equally spaced phases within the same epoch of {tau} Sco's 41 day rotation period. The XIS instrument has three operable detectors: XIS1 is back-illuminated with sensitivity down to 0.2 keV; XIS0 and XIS2 are front-illuminated with sensitivity only down to 0.4 keV and have an overall less effective area than XIS1. The XIS0 and XIS3 detectors show relatively little variability. In contrast, there is a {approx}4{sigma} detection of a {approx}4% drop in the count rate of the XIS1 detector at one rotational phase. In addition, all three detectors show a {approx}3% increase in count rate at the same phase. The most optimistic prediction of X-ray variability allows for a 40% change in the count rate, particularly near phases where we have pointings. Observed modulations in the X-ray light curve on the rotation cycle is an order of magnitude smaller than this, which places new stringent constraints on future modeling of this interesting magnetic massive star.

79 ASTRONOMY AND ASTROPHYSICS↗

A Joint Search for the Electromagnetic Counterpart to the Gravitational-Wave Binary Black-Hole Merger Candidate S250328ae with the Dark Energy Camera and the Prime Focus Spectrograph

The first detection of an optical counterpart to a gravitational wave signal revealed that collaborative efforts between instruments with different specializations provide a unique opportunity to acquire impactful multi-messenger data. We present results of such a joint search with the Dark Energy Camera (DECam) and Prime Focus Spectrograph (PFS) for the optical counterpart of the LIGO-Virgo-KAGRA event S250328ae, a binary black hole merger candidate of high significance detected at a distance of 511$\pm$82 Mpc and localized within an area of 3 (15) square degrees at 50% (90%) confidence. We observed the 90% confidence area with DECam and identified 36 high-confidence transient candidates after image processing, candidate selection, and candidate vetting. We observed with PFS to obtain optical spectra of DECam candidates, Swift-XRT candidates, and potential host galaxies of S250328ae. In total, 3897 targets were observed by seven pointings covering ~50% of the 90% confidence area. After template fitting and visual inspection, we identified 12 SNe, 159 QSOs, 2975 galaxies, and 131 stars. With the joint observations of DECam and PFS, we found variability in 12 SNe, 139 QSOs, 37 galaxies, and 2 stars. We do not identify any confident optical counterparts, though the association is not ruled out for three variable candidates that are not observed by PFS and 6 QSO candidates without clear variability if the optical counterpart of S250328ae is faint. Despite the lack of confident optical counterparts, this paper serves as a framework for future collaborations between wide-field imagers and multi-object spectrographs to maximize multi-messenger analyses.

Zhang, Haibin [Natl. Astron. Observ. of Japan] (OR↗

An Ansatz Regarding Relativistic Space Travel Part II-Propulsion Realities

Travel to the stars can involve a perilous journey in an unfriendly space-time continuum that can include singularities, nonlinear events, gravity as a function of both position and vehicle velocity, and extra dimensional effects discussed in Part I. Such a device may possibly use field propulsion technology. Although several field propulsion schemes exist, a proposed candidate is based upon using an electromagnetic drive that uses a rotating magnetic field superimposed on the spacecraft's stationary or static electric field. This is comparable to a Searl generator and the field interaction would generate an electromagnetic vortex to create nonlinear gravitational effects possibly due to an inverse Gertsenshtein relationship to push against the intrinsic gravitational field of a planet. Moreover, changing alignment of the magnetic field axis with the electric field will induce a margin of lateral controllability. Issues such as assessing this combined effect of using both electric and magnetic fields are discussed. Finally, the need for experimental data is stressed to validate these otherwise very speculative theoretical notions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the neutron detectors for the cluster fusion experiment on the Texas Petawatt Laser

Three types of neutron detectors (plastic scintillation detectors, indium activation detectors, and CR-39 track detectors) were calibrated for the measurement of 2.45 MeV DD fusion neutron yields from the deuterium cluster fusion experiment on the Texas Petawatt Laser. A Cf-252 neutron source and 2.45 MeV fusion neutrons generated from laser-cluster interaction were used as neutron sources. The scintillation detectors were calibrated such that they can detect up to 10{sup 8} DD fusion neutrons per shot in current mode under high electromagnetic pulse environments. Indium activation detectors successfully measured neutron yields as low as 10{sup 4} per shot and up to 10{sup 11} neutrons. The use of a Cf-252 neutron source allowed cross calibration of CR-39 and indium activation detectors at high neutron yields ({approx}10{sup 11}). The CR-39 detectors provided consistent measurements of the total neutron yield of Cf-252 when a modified detection efficiency of 4.6 Multiplication-Sign 10{sup -4} was used. The combined use of all three detectors allowed for a detection range of 10{sup 4} to 10{sup 11} neutrons per shot.

43 PARTICLE ACCELERATORS↗