Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diesel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Energy consumption and charging load profiles from long-haul truck electrification in the United States

Abstract The urgent need to decarbonize the transportation sector combined with falling battery prices has spurred industry and policy interest in long-haul truck electrification. The charging behavior and resulting loads from electrified long-haul freight trucks are crucial for the smooth operation of the electric grid and have far-reaching environmental impacts (e.g., greenhouse gas and other air pollutant emissions). However, the aggregate energy impact of a fleetwide shift to electrified long-haul freight trucking has not been explored. This study combines electric truck design scenarios, bottom-up truck weight modeling, vehicle energy modeling, large-scale truck traffic data, and simulation of likely operation and charging behaviors to estimate end-use energy consumption and location-specific hourly charging loads for a national fleet of long-haul electric trucks. Relative to a fleet of future diesel trucks, electrification would reduce direct end-use energy consumption by 0.9 × 10 18 J (0.9 quadrillion BTU), but electrification might increase life cycle energy consumption depending on the electricity source. The electricity required to charge long-haul electric trucks is equivalent to five percent of annual electricity consumption in the United States (US). The simulated truck charging loads peak during the day across the US grid regions, but the charging peaks’ exact timing is sensitive to when trucks are dispatched for operation. The load shapes suggest that electric trucks’ charging loads can coincide with peaks in solar power generation, and planning could enable on- or off-site integration between truck charging stations and renewable electricity generation.

Tong, Fan (ORCID:0000000346613956)↗

Techno-economic analysis of synthetic fuel production from existing nuclear power plants across the United States

Abstract Low carbon synfuel can reduce dependence on fossil fuels like diesel and jet fuel, and, with large-scale cost-effective production, contribute to global transportation sector decarbonization, Simultaneously, nuclear power plants are struggling economically due to falling wholesale electricity prices. Converting existing nuclear plants for synfuel production could preserve these low-carbon assets and enable large-scale synfuel production, yet no comprehensive technoeconomic analysis exists. This study evaluates the potential of integrating synthetic fuel production with five US nuclear plants, considering electricity and fuel markets and carbon dioxide source access. Such integration could enhance nuclear plant profitability by up to $792 million and offer a 10% return on investment over 20 years. The hydrogen production tax credit from the 2022 Inflation Reduction Act is crucial, comprising 75% of revenues on average. Carbon feedstock transportation has the highest cost at 35%, followed closely by synfuel production capital costs. Incentive policies are thus key for the decarbonization of the transportation sector and the economic importance of the geographic location of Integrated Energy Systems.

Garrouste, Marisol (ORCID:0000000168388644)↗

Planning for a Resilient Home Electricity Supply System

Resilience of power systems is already a key issue that is getting frequent attention all over the world. It is useful to analyze resilience issues not only for bulk supply, but at all levels including at a customer level. This is because distributed energy resources can play a prominent role in enhancing resilience. Although the literature on planning models, tools and data for bulk supply and distribution systems have expanded in recent years, customer-centric planning, e.g., for an individual household, is yet to receive adequate attention. Although solar PV and battery storage at a household level have been analyzed, how these resources can be optimally combined, together with grid supply, from a resilience perspective is the focus of this study. The study demonstrates how a conceptual framework can be developed to show the trade-off between system costs and resilience including its dimensions such as duration, depth and frequency of service outages. A planning model is developed that incorporates multiple facets of resilience and individual customer preferences. The model considers power system resilience explicitly as a constraint. The model is implemented for a household level case study in Miami, Florida. The results show there are complex trade-offs among different dimensions of resilience. The study demonstrates how combined resilience metrics can be formulated and evaluated using the proposed least-cost planning model at a household level to optimize grid supply together with solar, battery storage and diesel generators. The model allows a planner to directly embed a resilience standard to drive the optimal supply mix. These concepts and the modeling construct can also be applied at other levels of planning, including community level and bulk supply system planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Scheduling of Microgrids Considering Unintentional Islanding Conditions

This paper proposes a robust scheduling model for microgrids considering the stochastic unintentional islanding conditions. The proposed model minimizes the total operating cost of the microgrid by efficiently coordinating the supply of power from local distributed energy resources and the main grid. To capture the prevailing uncertainties in renewable generation and demand as well as unintentional islanding conditions, a two-stage adaptive robust optimization model is formulated to minimize the total operating cost under the worst realization of the modeled uncertainties. The column and constraint generation (C&CG) method is used to solve the problem in an iterative manner. The solution of the proposed scheduling model ensures robust microgrid operation in consideration of all possible realization of renewable generation, demand and unintentional islanding condition. Numerical simulations on a microgrid consisting of a wind turbine, a PV panel, a fuel cell, two micro-turbines, a diesel generator and a battery demonstrate the effectiveness of the proposed approach.

Liu, Guodong↗

Development of a Practical Secondary Control for Hardware Microgrids

Practical, vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids (MGs) with multiple grid-forming (GFM) inverter-based resources (IBRs) have not yet been developed. Therefore, this paper proposes a generic and vendor-agnostic secondary control architecture that operates with all GFM IBRs and synchronous generators. This secondary control does not require the use of additional measurement devices in the MG and utilizes the inherent communication systems of the GFM units, such as Modbus TCP/IP. The practical challenges of Modbus registers, such as packet loss and quantization error, and their detrimental impacts on secondary control actions are investigated. The proposed three-stage modification for any secondary control architecture to mitigate these impacts includes: 1) averaging the data read, 2) situational event-triggering of the controller, and 3) finite iteration of the controlling action. The proposed method is validated using a 3-..phi.., 480 V, 60 Hz, 500 kVA laboratory hardware microgrid with commercial two GFM IBRs and one diesel generator. The experimental results corroborates the fact the proposed modification in the secondary control architecture is advantageous for practical usage under erroneous measurements.

communication systems↗

Integration of Electrolysis Systems Into Isolated Microgrid Systems at Extreme Cold Climates

Isolated microgrid systems are generally used to power communities in remote locations where transmission line installations are cost prohibitive. These systems are usually powered by diesel generators, delivering expensive energy with high carbon emissions. However, most of these communities have special geographic access to renewable energy. These special conditions make it interesting to investigate the deployment of renewable energies and storage solutions. Within this scope, this paper analyses the integration of water electrolysis systems into off-grid communities, simulating the electrolyzer as well as the whole electrical grid in real time.

digital real-time simulation↗

Interoperable, Inverter - Based Distributed Energy Resources Enable 100% Renewable and Resilient Utility Microgrids

As microgrids transition away from use of conventional generating resources and increasingly rely on renewable resources towards decarbonization goals, it is crucial to evaluate the capability inverter-based resources to provide microgrid stability and resilience. Particularly, microgrids with a high contribution of intermittent solar photo voltaic generation and higher load variability present unique challenges requiring fast voltage and frequency support. At the San Diego Gas & Electric Company(R) (SDG&E(R)) Borrego Springs Microgrid, a battery inverter was upgraded with grid-forming (GFM) capability to serve as island leader, transitioning responsibility away from diesel generators. An interoperable microgrid control scheme was developed, coordinating GFM and grid-following (GFL) inverters. Hardware-in-the-loop (HIL) simulations using relevant power and controller HIL interfaces between real-time simulators and field equipment are being conducted to de-risk field deployment.

battery energy storage↗

Droop Control-Based Dispatch of an Islanded Microgrid with Multiple Grid-Forming Sources

Before rotating, fossil fuel-based, synchronous generators (SGs) are phased out, in line with renewable generation goals, grid-forming (GFM) inverters are expected to parallel SGs. Primary droop control allows GFM inverters to share power without communication; however, it is necessary to dispatch GFM inverters and/or SGs with the desired output power for better energy management (e.g., one GFM inverter needs to charge the battery due to a low state of charge). Therefore, this paper develops an analytic approach to dispatching GFM inverters and SGs with the desired output power by shifting the droop intercept up/down while maintaining the same frequency operating point for improved transient stability. This concept is demonstrated through a pure hardware setup with two off-the-shelf inverters and one diesel generator under an islanded microgrid, and we provide insight on the real-world implementation of the proposed concept.

droop control↗

Electrifying Education: Insights into Charging Electric School Buses in the United States

To combat climate change, the United States joined 193 Parties in committing to the Paris Agreement, which aims to limit global warming to 2 degrees C or less, and decarbonizing transportation will be a key requirement for achieving this goal. School buses (SBs) are a common form of student transport in the U.S. with nearly all SBs today powered by fossil fuels (primarily diesel). As a result, SBs have historically been a concerning source of both greenhouse gas (GHG) emissions and local air pollutants with negative health impacts for students and others living nearby. Electric SBs (ESBs) are a promising emerging technology for decarbonizing student transport, however, ESB adoption in the U.S. remains at an early stage (approximate 1.1%) with many outstanding uncertainties. This study aims to elucidate several of these by taking inventory of the total SB stock within U.S. states and studying real-world SB operating profiles to infer potential battery range requirements, daily charging opportunities, and charging infrastructure requirements for ESBs. In addition, we observe the geographic trends of early-stage ESB adoption, which can be used to better understand early adopter patterns and train vehicle technology adoption models.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Mass Detection for Heavy-Duty Vehicles using Gaussian Belief Propagation

Predicting vehicle mass is critical to accurately estimate energy use and emissions of commercial trucks. However, data from vehicle telematics is often not at sufficient temporal resolution or accuracy for use in model-based detection methods. In this work, a new statistical mass prediction technique is described for heavy-duty vehicles that incorporates the use Gaussian Belief Propagation (GBP) for probabilistic inference. Similar to Bayesian inference models, the GBP model typically requires less labeled training data than other contemporary machine learning techniques. First, a factor graph is constructed, and a set of Gaussian belief nodes with associated means and variances are fitted to the training data. To better handle noisy input data, the GBP mass prediction model utilizes a k-nearest factors (kNF) algorithm for probabilistic inference on unseen testing data. The proposed method is compared with a classical weighted k-nearest neighbors (kNN) regressor. This statistical kNF-GBP model works even with low-quantity, low-quality initial training data, while being capable of realtime mass estimation. Unlike the kNN regressor, the GBP model produces a measure of uncertainty with its predictions. The proposed method is validated using curve-sampled driving data collected from multiple cloud-connected Class 8 regional haul diesel trucks. Both the kNN regressor and the kNF-GBP mass prediction model were able to predict payload mass with coefficients of determination above 0.97 with minimal data preprocessing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Model-Based Framework to Optimize Charger Station Deployment for Battery Electric Vehicles

The development of battery electric vehicles (BEVs) is accelerating due to their environmental advantages over gasoline and diesel-powered vehicles, including a decrease in air pollution and an increase in energy efficiency. The deployment of charging infrastructure will need to increase to keep pace with demand, especially for large commercial vehicles for which few public chargers currently exist. In this paper, a new flexible framework is proposed for optimizing the placement of charging stations for BEVs, within which different physical models and optimization techniques may be used. Furthermore, a set of metrics is suggested to help enforce complex constraints and facilitate direct comparison between different optimization techniques. Unlike many existing charger placement techniques, the proposed method directly considers the historical driving patterns on a vehicle-by-vehicle basis, using transparent models to assess impacts of candidate charger placements, thus improving the explainability of the results. In the developed framework, modeled BEVs are first generated along the road network to mimic historical traffic data and are simulated traveling along a given route according to a simplified vehicle model. During the simulation, the charger placement problem is initially relaxed to allow vehicles to charge at any node along the road network, and vehicle states are tracked to assess areas of high charging demand. Charging stations are then placed based on the results of the relaxed simulation, and suggested placements are evaluated via road network simulation with fixed charger locations. This proposed framework is applied to a sample problem of placing charging stations along five major highway corridors for Class 8 over-the-road electric trucks. A novel mixed integer programming (MIP) formulation is proposed to optimize charger placements based upon the expected charging demand. Constraints were imposed on the final placement results to limit expected wait times at each station and ensure a minimum threshold of trucking routes are viable for BEVs. The results demonstrate the flexibility and potential effectiveness of the developed model-based framework for scalable charger station deployment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Microgrid Power Flow Control with Integrated Battery Management Functions

This paper presents a microgrid power flow control for islanded microgrids consisting of photovoltaic (PV) system, battery energy storage system (BESS) and diesel generator. The proposed control ensures automatic coordination among the microgrid units. To achieve the coordination, the local control of PV system and BESS are configured to regulate power flow without relying on communications. The generator is controlled as the back-up source and its connection depends on battery state of charge (SOC). A state machine with hysteresis settings is used to trigger smooth transition among operation modes. Not only does the proposed controller consider battery SOC and power limits, but also integrates three-stage charging control as battery charging mechanism, which is not considered in the existing literature. The proposed control is validated for an islanded hybrid microgrid using an OPAL-RT real-time simulator.

Long, Qian↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. GFM inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generators) and follow the change in the load demand; however, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help grid operators better manage their inverter-based resources (IBRs) to improve operation efficiency and reliability; therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and synchronous generators) to output the target power in both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters.

dispatching↗

Impacts of Dispatch Strategies and Forecast Errors on the Economics of Behind-the-Meter PV-Battery Systems

To assess the economic value of batteries in hybrid PV-battery systems, one must create a dispatch profile for the battery. Many analyses of battery value assume perfect forecasts of PV generation and load, determining an upper limit on the value of the battery. Prior work that accounts for forecast uncer- tainty often does so in the context of a single dispatch algorithm, which does not provide a baseline for comparison. Furthermore, when multiple dispatch algorithms are assessed with uncertainty, the benefits considered are for diesel generation in a microgrid, not retail rate savings. This work addresses the gaps in the literature by comparing the performance of both heuristic and optimal dispatch algorithms for retail rate savings under forecast uncertainty, and provides comparisons of the robustness of these algorithms and their associated estimates of economic value. We find that using a perfect forecast can overestimate the value of hybrid PV-battery systems between 1% and 8% compared to the reality of using a day-ahead forecast, depending on the dispatch algorithm used. Thus, accounting for forecast uncertainty in system design and analysis will significantly improve the accuracy of modeled system values.

batteries↗

A regional inter-disciplinary partnership focusing on the development of a carinata-centered bioeconomy

Brassica carinata or Ethiopian mustard, a non-edible oilseed brassica, is a low carbon, purpose-grown, and none-to-low indirect land-use change bioenergy feedstock for the production of drop-in sustainable aviation fuel, biodiesel, renewable diesel, and a suite of value-added coproducts. Carinata oil converted to drop-in fuel using an American Society for Testing and Materials approved Catalytic Hydrothermolysis process has been successfully tested in commercial and military aviation. Carinata meal, the residue after oil extraction, is a high-protein feed supplement for livestock, poultry, and swine, and can also yield specialty products. The Southeast Partnership for Advanced Renewables from Carinata (SPARC) is a public–private partnership formed with a twofold mission: (1) Removing physical, environmental, social, and economic constraints that prevent regional intensification of carinata production as a low-carbon feedstock for renewable fuel and coproducts and (2) demonstrating enhanced value across the entire value chain by mitigating risk to farmers and other stakeholders. The partnership's goal is to energize the US bioeconomy through sustainable agriculture and thus contribute to energy security and economic diversification. SPARC relies on a combination of cutting-edge multidisciplinary research and active industry engagement to facilitate adoption of the crop. This involves informing stakeholders along the entire supply chain, from producers to end-users, policymakers, influencers, and the public, about the opportunities and best practices related to carinata. This article provides context and background concerning carinata commercialization as a winter cash crop in the Southeast US for renewable fuels and bioproducts. The advances made to date in the areas of feedstock development, fuel and coproduct development, meal valorization, supply chain logistics, and stakeholder engagement are outlined.

09 BIOMASS FUELS↗

MACHINE LEARNING-ENABLED PREDICTION OF TRANSIENT INJECTION MAP IN AUTOMOTIVE INJECTORS WITH UNCERTAINTY QUANTIFICATION

Accurate prediction of injection profiles is a critical aspect of linking injector operation with engine performance and emissions. However, highly resolved injector simulations can take one to two weeks of wall-clock time, which is incompatible with engine design cycles with desired turnaround times of less than a day. Hence, it is important to reduce the time-to-solution of the internal flow simulations by several orders of magnitude to make it compatible with engine simulations. This work demonstrates a data-driven approach for tackling the computational overhead of injector simulations, whereby the transient injection profiles are emulated for a side-oriented, single-hole diesel injector using a Bayesian machine-learning framework. First, an interpretable Bayesian learning strategy was employed to understand the effect of design parameters on the total void fraction field. Then, autoencoders are utilized for efficient dimensionality reduction of the flowfields. Gaussian process models are finally used to predict the spatiotemporal void fraction field at the injector exit for unknown operating conditions. The Gaussian process models produce principled uncertainty estimates associated with the emulated flowfields, which provide the engine designer with valuable information of where the data-driven predictions can be trusted in the design space. The Bayesian flowfield predictions are compared with the corresponding predictions from a deep neural network, which has been transfer-learned from static needle simulations from a previous work by the authors. The emulation framework can predict the void fraction field at the exit of the orifice within a few seconds, thus achieving a speed-up factor of up to 38 x 10(6) over the traditional simulation-based approach of generating transient injection maps.

machine learning↗

Design, Modeling, and Control of a Hardware-in-the-Loop Testbed for Off-Road Vehicles

This paper presents the design, modeling, and control of a hardware-in-the-loop (HIL) testbed for off-road vehicles. The proposed HIL testbed employs a transient hydrostatic dynamometer to load a diesel engine to emulate any loading cycles of a wheel loader, which is a representative off-road vehicle. A fully validated wheel loader model is used to calculate the engine load, including both the drive and work functions. Besides, iterative learning control (ILC) has been designed for the loading torque tracking of the hydrostatic dynamometer to ensure accurate emulation of real-world operation scenarios. The developed HIL testbed is used to demonstrate more than 26% energy benefits of automated wheel loaders through systematic optimization compared with human-operated wheel loaders. As a result, this HIL testbed serves as a robust platform for advancing research and development across various off-road vehicles, including excavators, tractors, and harvesters.

33 ADVANCED PROPULSION SYSTEMS↗

CONTROLLED END GAS AUTO IGNITION WITH EXHAUST GAS RECIRCULATION ON A STOICHIOMETRIC, SPARK IGNITED, NATURAL GAS ENGINE

The goal of this study is to address fundamental limitations to achieving diesel-like efficiencies in heavy duty on-highway natural gas (NG) engines. Engine knock and misfire are barriers to pathways leading to higher efficiency engines. This study explores enabling technologies for development of high efficiency stoichiometric, spark ignited, natural gas engines. These include design strategies for fast and stable combustion and higher dilution tolerance. Additionally, advanced control methodologies are implemented to maintain stable operation between knock and misfire limits. To implement controlled end- gas autoignition (C-EGAI) strategies a Combustion Intensity Metric (CIM) is used for ignition control with the use of a Woodward large engine control module (LECM). Tests were conducted using a single cylinder, variable compression ratio, cooperative fuel research (CFR) engine with baseline conditions of 900 RPM, engine load of 800 kPa indicated mean effective pressure (IMEP), and stoichiometric air/fuel ratio. Exhaust gas recirculation (EGR) tests were performed using a custom EGR system that simulates a high pressure EGR loop and can provide a range of EGR rates from 0 to 40%. The experimental measurements included the variance of EGR rate, compression ratio, engine speed, IMEP, and CIM. These five variables were optimized through a Modified Box- Benken design Surface Response Method (RSM), with brake efficiency as the merit function. A positive linear correlation between CIM and f-EGAI was identified. Consequently, CIM was used as the feedback control parameter for C-EGAI. As such, implementation of C-EGAI effectively allowed for the utilization of high EGR rates and CRs, controlling combustion between a narrower gap between knock and lean limits. The change from fixed to parametric ignition timing with CIM targeted select values of f-EGAI with an average coefficient of variance (COV) of peak pressure of 5.4. The RSM efficiency optimization concluded with operational conditions of 1080 RPM, 1150 kPa IMEP, 10.55:1 compression ratio, and 17.8% EGR rate with a brake efficiency of 21.3%. At this optimized point of peak performance, a f-EGAI for C-EGAI was observed at 34.1% heat release due to auto ignition, a knock onset crank angle value of 10.3° aTDC and ignition timing of - 24.7° aTDC. This work has demonstrated that combustion at a fixed f-EGAI can be maintained through advanced ignition control of CIM without experiencing heavy knocking events.

Cooperative Fuel Research Engine, Auto Ignition, E↗