Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Cosmic ray muon computed tomography of spent nuclear fuel in dry storage casks

Radiography with cosmic ray muon scattering has proven to be a successful method of imaging nuclear material through heavy shielding. Of particular interest is monitoring dry storage casks for diversion of plutonium contained in spent reactor fuel. Using muon tracking detectors that surround a cylindrical cask, cosmic ray muon scattering can be simultaneously measured from all azimuthal angles, giving complete tomographic coverage of the cask interior. This article describes the first application of filtered back projection algorithms, typically used in medical imaging, to cosmic ray muon scattering imaging. The specific application to monitoring spent nuclear fuel in dry storage casks is investigated via GEANT4 simulations. With a cylindrical muon tracking detector surrounding a typical spent fuel cask, simulations indicate that missing fuel bundles can be detected with a statistical significance of ~18σ in less than two days exposure and a sensitivity at 1σ to a 5% missing portion of a fuel bundle. Finally, we discuss potential detector technologies and geometries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photoproduction of the b 1 (1235) Meson off the proton at E gamma = 6-12 GeV

The GlueX Experiment at Jefferson Lab directs a linearly polarized photon beam on a liquid hydrogen target surrounded by an almost hermetic detector. The experiment aims to study the meson spectrum in the light-quark sector and search for exotic spin-parity states predicted by lattice QCD calculations. The lightest exotic candidate is the π 1 meson, which is predicted to decay dominantly to b 1 π. In this thesis, we present efforts to characterize the ωπ 0 decay channel of the b 1 meson as precursor to an analysis of the sought-after π 1 exotic state. We present an introduction to the physics involved and an overview of the detector subsystems with a focus on the Barrel Calorimeter gain monitoring system, as part of the service work expected by the GlueX Collaboration. We discuss the data analysis method used and present two frameworks, for angular moments and partial waves analyses. Details of the simulation used to calculate the detector acceptance. A proof of concept partial wave analysis is presented along with experimental angular moments as first step to a full analysis of the angular distribution Our partial wave analysis indicates that both S- and D-waves are needed, in qualitative agreement with theoretical expectations. The cross-section of the omega π 0 channel is extracted to be of the scale of 1 μb in agreement with previous measurements. The differential cross-section indicates the presence of two production processes with p 1 = -5:24 ± 0:04 for 0:25 < -t < 0:95 GeV 2 ~c 2 and p 2 = -1:24 ± 0:05 for 0:95 < -t < 2:0 GeV 2 ~c 2 , which does not agree with results from previous experiments. The s-channel helicity conservation and helicity amplitudes of the b 1 meson are presented as additional experimental observables. Our results confirm that the b1 photoproduction process does not conserve s-channel helicity though they do not align with previous measurements. The helicity amplitude of the omega are extracted to be |F 1 | 2 = 0:3037 ± 0:0003 which does not agree with the expected value of a b 1 decay or results from a previous experiment. Future steps in all these analyses will be continued by a new graduate student in the group, culminating in a publication.

Foda, Ahmed↗

Jet energy scale and resolution in the CMS experiment in pp collisions at 8 TeV

Improved jet energy scale corrections, based on a data sample corresponding to an integrated luminosity of 19.7 fb(-1) collected by the CMS experiment in proton-proton collisions at a center-of-mass energy of 8 TeV, are presented. The corrections as a function of pseudorapidity η and transverse momentum p(T) are extracted from data and simulated events combining several channels and methods. They account successively for the effects of pileup, uniformity of the detector response, and residual data-simulation jet energy scale differences. Further corrections, depending on the jet flavor and distance parameter (jet size) R, are also presented. The jet energy resolution is measured in data and simulated events and is studied as a function of pileup, jet size, and jet flavor. Typical jet energy resolutions at the central rapidities are 15–20% at 30 GeV, about 10% at 100 GeV, and 5% at 1 TeV. The studies exploit events with dijet topology, as well as photon+jet, Z+jet and multijet events. Several new techniques are used to account for the various sources of jet energy scale corrections, and a full set of uncertainties, and their correlations, are provided.The final uncertainties on the jet energy scale are below 3% across the phase space considered by most analyses (p(T),>30 GeV and 0| η| <5.). In the barrel region (| η| <1.3) an uncertainty below 1% for p(T)>30 GeV is reached, when excluding the jet flavor uncertainties, which are provided separately for different jet flavors. A new benchmark for jet energy scale determination at hadron colliders is achieved with 0.32% uncertainty for jets with \pt of the order of 165–330\GeV, and | η| <0.8.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dijet invariant mass distribution in top quark hadronic decay with QCD corrections

The dijet invariant mass distributions from the hadronic decay of unpolarized top quark (t{yields}bW{sup +} followed by W{sup +}{yields}ud) are calculated, including the next-to-leading order QCD radiative corrections. We treat the top decay in the complex mass scheme due to the existence of the intermediate state W boson. Our analytical expressions are also available in different dimensional regularization schemes and {gamma}{sub 5} strategies. Finally, in order to construct the jets, we use different jet algorithms to compare their influences on our results. The obtained dijet mass distributions from the top quark decay are useful to distinguish these dijets from those produced via other sources and to clarify the issue about the recent CDF Collaboration's Wjj anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy

Purpose: To investigate experimentally the energy dependence of the detector response of lithium formate EPR dosimeters for photon energies below 1 MeV relative to that at {sup 60}Co energies. High energy photon beams are used in calibrating dosimeters for use in brachytherapy since the absorbed dose to water can be determined with high accuracy in such beams using calibrated ion chambers and standard dosimetry protocols. In addition to any differences in mass-energy absorption properties between water and detector, variations in radiation yield (detector response) with radiation quality, caused by differences in the density of ionization in the energy imparted (LET), may exist. Knowledge of an eventual deviation in detector response with photon energy is important for attaining high accuracy in measured brachytherapy dose distributions. Methods: Lithium formate EPR dosimeters were irradiated to known levels of air kerma in 25-250 kV x-ray beams and in {sup 137}Cs and {sup 60}Co beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free in air into values of mean absorbed dose to the detectors were made using EGSnrc MC simulations and x-ray energy spectra measured or calculated for the actual beams. The signals from the detectors were measured using EPR spectrometry. Detector response (the EPR signal per mean absorbed dose to the detector) relative to that for {sup 60}Co was determined for each beam quality. Results: Significant decreases in the relative response ranging from 5% to 6% were seen for x-ray beams at tube voltages {<=}180 kV. No significant reduction in the relative response was seen for {sup 137}Cs and 250 kV x rays. Conclusions: When calibrated in {sup 60}Co or MV photon beams, corrections for the photon energy dependence of detector response are needed to achieve the highest accuracy when using lithium formate EPR dosimeters for measuring absorbed doses around brachytherapy sources emitting photons in the energy range of 20-150 keV such as {sup 169}Yb and electronic sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

Novel approach for evaluating detector-related uncertainties in a LArTPC using MicroBooNE data

Primary challenges for current and future precision neutrino experiments using liquid argon time projection chambers (LArTPCs) include understanding detector effects and quantifying the associated systematic uncertainties. This paper presents a novel technique for assessing and propagating LArTPC detector-related systematic uncertainties. The technique makes modifications to simulation waveforms based on a parameterization of observed differences in ionization signals from the TPC between data and simulation, while remaining insensitive to the details of the detector model. The modifications are then used to quantify the systematic differences in low- and high-level reconstructed quantities. This approach could be applied to future LArTPC detectors, such as those used in SBN and DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable Programming Model Exploration for LArTPC Simulation in a Heterogeneous Computing Environment: OpenMP vs. SYCL

The evolution of the computing landscape has resulted in the proliferation of diverse hardware architectures, with different flavors of GPUs and other compute accelerators becoming more widely available. To facilitate the efficient use of these architectures in a heterogeneous computing environment, several programming models are available to enable portability and performance across different computing systems, such as Kokkos, SYCL, OpenMP and others. As part of the High Energy Physics Center for Computational Excellence (HEP-CCE) project, we investigate if and how these different programming models may be suitable for experimental HEP workflows through a few representative use cases. One of such use cases is the Liquid Argon Time Projection Chamber (LArTPC) simulation which is essential for LArTPC detector design, validation and data analysis. Following up on our previous investigations of using Kokkos to port LArTPC simulation in the Wire-Cell Toolkit (WCT) to GPUs, we have explored OpenMP and SYCL as potential portable programming models for WCT, with the goal to make diverse computing resources accessible to the LArTPC simulations. In this work, we describe how we utilize relevant features of OpenMP and SYCL for the LArTPC simulation module in WCT. We also show performance benchmark results on multi-core CPUs, NVIDIA and AMD GPUs for both the OpenMP and the SYCL implementations. Comparisons with different compilers will also be given where appropriate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Monoenergetic Low Energy Neutron Fields with the {mu}TPC Detector

The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection Chamber is being developed to be dedicated to measure neutron fields with energy ranging from 2 keV up to 1 MeV. We present simulations showing that such a detector, which allows the measurement of the ionization energy and the 3D reconstruction of the recoil nucleus, provides the determination of neutron energy and fluence of such low energy neutron fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel method for modeling the neutron time of flight (nTOF) detector response in current mode to inertial confinement fusion experiments.

There are several machines in this country that produce short bursts of neutrons for various applications. A few examples are the Z machine, operated by Sandia National Laboratories in Albuquerque, NM ; the OMEGA Laser Facility at the University of Rochester in Rochester, NY ; and the National Ignition Facility (NIF) operated by the Department of Energy at Lawrence Livermore National Laboratory in Livermore, California . They all incorporate neutron time of flight (nTOF) detectors which measure neutron yield, and the shapes of the waveforms from these detectors contain germane information about the plasma conditions that produce the neutrons. However, the signals can also be %E2%80%9Cclouded%E2%80%9D by a certain fraction of neutrons that scatter off structural components and also arrive at the detectors, thereby making analysis of the plasma conditions more difficult. These detectors operate in current mode - i.e., they have no discrimination, and all the photomultiplier anode charges are integrated rather than counted individually as they are in single event counting. Up to now, there has not been a method for modeling an nTOF detector operating in current mode. MCNP PoliMi was developed in 2002 to simulate neutron and gamma ray detection in a plastic scintillator, which produces a collision data output table about each neutron and photon interaction occurring within the scintillator; however, the post processing code which accompanies MCNP PoliMi assumes a detector operating in single event counting mode and not current mode. Therefore, the idea for this work had been born: could a new post processing code be written to simulate an nTOF detector operating in current mode? And if so, could this process be used to address such issues as the impact of neutron scattering on the primary signal? Also, could it possibly even identify sources of scattering (i.e., structural materials) that could be removed or modified to produce %E2%80%9Ccleaner%E2%80%9D neutron signals? This process was first developed and then applied to the axial neutron time of flight detectors at the Z Facility mentioned above. First, MCNP PoliMi was used to model relevant portions of the facility between the source and the detector locations. To obtain useful statistics, variance reduction was utilized. Then, the resulting collision output table produced by MCNP PoliMi was further analyzed by a MATLAB postprocessing code. This converted the energy deposited by neutron and photon interactions in the plastic scintillator (i.e., nTOF detector) into light output, in units of MeVee%D1%84 (electron equivalent) vs time. The time response of the detector was then folded into the signal via another MATLAB code. The simulated response was then compared with experimental data and shown to be in good agreement. To address the issue of neutron scattering, an %E2%80%9CIdeal Case,%E2%80%9D (i.e., a plastic scintillator was placed at the same distance from the source for each detector location) with no structural components in the problem. This was done to produce as %E2%80%9Cpure%E2%80%9D a neutron signal as possible. The simulated waveform from this %E2%80%9CIdeal Case%E2%80%9D was then compared with the simulated data from the %E2%80%9CFull Scale%E2%80%9D geometry (i.e., the detector at the same location, but with all the structural materials now included). The %E2%80%9CIdeal Case%E2%80%9D was subtracted from the %E2%80%9CFull Scale%E2%80%9D geometry case, and this was determined to be the contribution due to scattering. The time response was deconvolved out of the empirical data, and the contribution due to scattering was then subtracted out of it. A transformation was then made from dN/dt to dN/dE to obtain neutron spectra at two different detector locations.

Nelson, Alan J.↗

Comparison between simulated and observed LHC beam backgrounds in the ATLAS experiment at E beam =4 TeV

Results of dedicated Monte Carlo simulations of beam-induced background (BIB) in the ATLAS experiment at the Large Hadron Collider (LHC) are presented and compared with data recorded in 2012. During normal physics operation this background arises mainly from scattering of the 4 TeV protons on residual gas in the beam pipe. Methods of reconstructing the BIB signals in the ATLAS detector, developed and implemented in the simulation chain based on the \textsc{Fluka} Monte Carlo simulation package, are described. The interaction rates are determined from the residual gas pressure distribution in the LHC ring in order to set an absolute scale on the predicted rates of BIB so that they can be compared quantitatively with data. Through these comparisons the origins of the BIB leading to different observables in the ATLAS detectors are analysed. The level of agreement between simulation results and BIB measurements by ATLAS in 2012 demonstrates that a good understanding of the origin of BIB has been reached.

47 OTHER INSTRUMENTATION↗

A new track finding algorithm based on a multi-dimensional extension of the Hough Transform

We introduce a new pattern recognition algorithm for track finding in High Energy Physics Experiments based on an extension of the Hough Transform to multiple dimensions. A remarkable property of this algorithm is that the execution time is simply proportional to the total number of the hits to be processed, making it particularly attractive for high occupancy situations. The algorithm needs to be trained using a sufficiently large set of simulated tracks. The same track finding algorithm can be used for very different detector geometries and only the set of simulated tracks used for training needs to be changed. The particular structure of the algorithm also lends itself naturally to parallel hardware implementations which, combined with its intrinsic flexibility, should provide a most powerful tool for triggering at future colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lasnex simulated neutron production rates of MagLIF driven by 17.5 MA

Time resolved neutron detection will provide important information of MagLIF implosions. To aid the design of such detectors Lasnex has been used to simulate the neutron production rates for two MagLIF configurations. The results are shown in Fig 1 a) B=15 T, preheat=1.1 kJ, D 2 density=1.05 mg/cc and b) B=10 T, preheat=0.8 kJ, D 2 density=0.7 mg/cc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation results of Pulse Shape Discrimination (PSD) for background reduction in INTEGRAL Spectrometer (SPI) germanium detectors

Pulse Shape Discrimination (PSD) for background reduction will be used in the INTErnational Gamma Ray Astrophysics Laboratory (INTEGRAL) imaging spectrometer (SPI) to improve the sensitivity from 200 keV to 2 MeV. The observation of significant astrophysical gamma ray lines in this energy range is expected, where the dominant component of the background is the beta(sup -) decay in the Ge detectors due to the activation of Ge nuclei by cosmic rays. The sensitivity of the SPI will be improved by rejecting beta(sup -) decay events while retaining photon events. The PSD technique will distinguish between single and multiple site events. Simulation results of PSD for INTEGRAL-type Ge detectors using a numerical model for pulse shape generation are presented. The model was shown to agree with the experimental results for a narrow inner bore closed end cylindrical detector. Using PSD, a sensitivity improvement factor of the order of 2.4 at 0.8 MeV is expected.

Slassi-Sennou, S. A.↗

Electromagnetic Simulations of Newly Designed Semiconductor Bolometers for Submillimeter Observations

In the frame of the SPICA mission, new semiconductor bolometers have been designed for the POL instrument which is directly part of the HERSCHEL/PACS legacy. These detectors are cooled down to 50 mK and are sensitive to polarization for the 100, 200 and 350 μm wavelength bands. In this paper, 3D simulations have been carried out with the COMSOL Multiphysics software to design the two suspended interlaced silicon spirals which support the orthogonal absorbers (sensitive to the two polarizations) of the POL detectors. These simulations allow to optimize the design of the absorbers and to quantify the cross-polarization. In the last part of this paper, we explain how it is possible to reach the 200 and 350 μm bands from the layout of the 100-μm detector.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the muon neutrino charged-current mesonless cross section in the NOvA near detector

NOvA is a long-baseline accelerator neutrino experiment at Fermilab. Its physics goals include precision neutrino oscillation measurements, neutrino interaction cross-section measurements and beyond Standard Model explorations. We present a measurement of muon neutrino charged-current cross section with zero mesons in the final state at the NOvA near detector. This measurement is performed as a function of the kinematics of the final state muon. Our chosen interaction channel is especially sensitive to quasielastic and meson exchange current interactions and it provides handles for constraining the cross section systematic uncertainties in oscillation analyses in present and future experiments. For particle identification, we use a convolutional neural network (CNN) trained on individual particles simulated in the NOvA Near detector. This allows us to select the desired signal while reducing the potential bias from neutrino interaction modeling. We study strategies for constraining the remaining charged-pion background via Michel electron information in a template fitting approach. The main experimental result is a two-dimensional differential cross section as a function of final-state muon kinetic energy and polar angle. The parameters of this measurement, including binning and unfolding, were optimized to reduce the expected systematic uncertainty in the total cross section. The final result shows good agreement with the main GENIE-based simulation framework that was independently fine-tuned in NOvA. We finally propose improvements and subsequent steps that build on this analysis and further dissect the final states of neutrino interactions. This work has been supported by US DOE grant DE-SC0015684.

Sánchez Falero, Sebastián Jesús [Iowa State U.]↗

Novel features and GPU performance analysis for EM particle transport in the Celeritas code

Celeritas is a new computational transport code designed for high-performance simulation of high-energy physics detectors. This work describes some of its current capabilities and the design choices that enable the rapid development of efficient on-device physics. The abstractions that underpin the code design facilitate low-level performance tweaks that require no changes to the higher-level physics code. We evaluate a set of independent changes that together yield an almost 40% speedup over the original GPU code for a net performance increase of 220× for a single GPU over a single CPU running 8.4M tracks on a small demonstration physics app.

Johnson, Seth R.↗

Construction and performance of the barrel electromagnetic calorimeter for the Gluex experiment

The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carlo simulations, calibration and operational performance are described in this paper. The calorimeter records the time and energy deposited by charged and neutral particles created by a multi-GeV photon beam. It is constructed as a lead and scintillating-fiber calorimeter and read out with 3840 large-area silicon photomultiplier arrays. Particles impinge on the detector over a wide range of angles, from normal incidence at 90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique among calorimeters. The response of the calorimeter has been measured during a running experiment and performs as expected for electromagnetic showers below 2.5 GeV. Finally, we characterize the performance of the BCAL using the energy resolution integrated over typical angular distributions for π 0 and η production of σ E / E = 5 . 2 % / E ( GeV ) ⊕ 3 . 6 % and a timing resolution of σ = 150 ps at 1 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗