Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Distribution Service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Crowder College MARET Center (Final Scientific Technical Report)

Following decades of success in solar energy projects, the Missouri Legislature designated Crowder College in 1992 as the State's renewable energy education center. The resulting Missouri Alternative and Renewable Energy Technology (MARET) Center is recognized internationally for its contributions to the energy field. The mission of the MARET Center is to expand renewable energy throughout the region with education, applied research, and economic development. Educational programs include certification and transfer degrees encompassing green construction, solar thermal energy, solar electricity, and wind. The MARET Center also assists in new product development and other business support services in renewable energy. The Missouri Alternative and Renewable Energy Technology (MARET) Center at Crowder College hopes to eventually develop a 27,500 ft 2 facility as a living laboratory to support solar and other renewable and sustainable energy development through professional degrees, new product development and commercialization, renewable energy business incubation, and consumer education. The primary objective of the current project was to complete Stage One of this building, with solar, wind, and geothermal technologies installed to power its 9,216 ft 2 office, classroom, and research spaces. This MARET Center includes a modular roof structure that permits both solar module mounting and daylighting, PV/thermal hybrid modules pioneered in Crowder Solar Decathlon homes, modular electrical management subsystems; and modular delivery systems for heating and cooling the structure. The MARET Facility will operate as a Net Positive energy building, consistently producing surplus energy for distributed generation on the utility grid. The modular design of the energy systems within the building is to serve as a scalable and repeatable model for a wide variety of building applications and climate zones. As a living laboratory of renewable energy, exploring and validating new applications of solar and other renewable technologies, the MARET Facility will house a wide variety of programs which will advance implementation of renewable energy throughout the region. These program goals include; Curriculum in renewable energy for pre-engineering transfer programs; Certification and degree programs for technical degrees for Energy Efficiency, Wind, Photovoltaic and Solar Thermal professionals; Short courses and workshops for building management and design professionals; Public education and demonstration projects in renewable energy through conferences and K-12 educational outreach; Technical degree offering in building construction incorporating “best practices” for energy efficiency and renewables; and Business incubators for new renewable energy businesses and new product development. The new MARET facility will support the mission of the US Department of Energy (DOE) Solar Program, “to improve America’s security, environmental quality, and economic prosperity through public-private partnerships that bring reliable and affordable solar energy technologies to the marketplace,” through a variety of educational and business assistance programs. Further, technical innovations planned for the MARET facility and its applied research activities will advance the Solar Program strategic goals to “reduce the cost of solar energy to the point it becomes competitive in relevant energy markets (e.g., buildings, power plants) and for solar technology to enable a sustainable solar industry.” Overarching Goals relative to program needs, future expansion, flexibility, quality of materials, and construction and operational costs:; Experimental: The structure and systems of the building operate as an educational resource. The systems are meant to be a source for data collection and study for building users and instructors; Educational: Part of the evolution of this building and its ongoing goals is to use the building as an educational tool, one where new ideas developed in the world and especially at Crowder can be tested further as part of MARET's curriculum; LEED Platinum: achieve highest level of LEED certification; Net Zero: The building will utilize existing wind and alternate energy sources on campus and add solar PVT panels and achieve as close as possible to a net zero energy usage; and Phase II: The phase II portion of this project will expand the Internet student area, additional classrooms, and labs, as well as an auditorium and exhibit area.

14 SOLAR ENERGY↗

Simultaneous x-ray and neutron 4D tomographic study of drying-driven hydro-mechanical behavior of cement-based materials at moderate temperatures

The drying of cement-based materials is intimately related to their durability, which has significant economic, social and environmental repercussions. The evolution of the saturation of the pore network and the associated drying shrinkage are in fact leading causes of cracking and of the ensuing penetration of aggressive chemicals. This process is highly heterogeneous, due to the thermo-hydric spatial gradients developing in the material from the exposed surfaces to its core and because of local effects, driven by the intrinsically heterogeneous micro-structure (e.g., by the distribution of pores and aggregates). It follows that macroscopic, sample-scale measurements cannot fully disclose the complexity of the underlying processes. In the last few decades, significant advances in full-field techniques have allowed an unprecedented insight into these local processes. For cement-based materials, x-ray and neutron tomography lend themselves as ideal, and highly complementary, tools for the study of their thermo-hydro-mechanical behavior. Notably, the high sensitivity to density variations of x-ray imaging gives access to the developments of fractures, in 4D (3D + time). On the other hand, neutron tomography allows the study of the evolution of the moisture field in 4D, thanks to its high hydrogen sensitivity. The combination of these two techniques provides a unique insight in thermo-hydro-mechanical couplings, e.g., the effect of cracks on the water content field. This contribution presents novel 5D datasets (3D tomographies along time, plus truly simultaneous x-ray and Neutron rapid acquisitions) in-operando of a cement paste and of a concrete sample heated at moderate temperatures (up to 140{sup ∘}C). The analysis of this 5D data-set (once aligned in time and across modalities) allows for example a quantification of the 4D moisture profiles which were found to predict an overall water loss at hydric equilibrium coherent with the corresponding analytical analysis. In the cement paste sample, the x-ray dataset captures the evolution of an extensive cracking network, opening and propagation toward the core of the sample. A novel analysis procedure is here proposed which allows the extraction of these fractures and the analysis of their interplay with local drying as captured through neutron imaging. This for example reveals the depth of penetration of drying in the vicinity of the fractures along time, which is essential for the assessment and calibration of hydro-mechanical coupled models.

36 MATERIALS SCIENCE↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using high spatial resolution satellite imagery to map forest burn severity across spatial scales in a Pine Barrens ecosystem

As a primary disturbance agent, fire significantly influences local processes and services of forest ecosystems. Although a variety of remote sensing based approaches have been developed and applied to Landsat mission imagery to infer burn severity at 30 m spatial resolution, forest burn severity have still been seldom assessed at fine spatial scales (≤ 5 m) from very-high-resolution (VHR) data. Here we assessed a 432 ha forest fire that occurred in April 2012 on Long Island, New York, within the Pine Barrens region, a unique but imperiled fire-dependent ecosystem in the northeastern United States. The mapping of forest burn severity was explored here at fine spatial scales, for the first time using remotely sensed spectral indices and a set of Multiple Endmember Spectral Mixture Analysis (MESMA) fraction images from bi-temporal — pre- and post-fire event — WorldView-2 (WV-2) imagery at 2 m spatial resolution. We first evaluated our approach using 1 m by 1 m validation points at the sub-crown scale per severity class (i.e. unburned, low, moderate, and high severity) from the post-fire 0.10 m color aerial ortho-photos; then, we validated the burn severity mapping of geo-referenced dominant tree crowns (crown scale) and 15 m by 15 m fixed-area plots (inter-crown scale) with the post-fire 0.10 m aerial ortho-photos and measured crown information of twenty forest inventory plots. Our approach can accurately assess forest burn severity at the sub-crown (overall accuracy is 84% with a Kappa value of 0.77), crown (overall accuracy is 82% with a Kappa value of 0.76), and inter-crown scales (89% of the variation in estimated burn severity ratings (i.e. Geo-Composite Burn Index (CBI)). Lastly, this work highlights that forest burn severity mapping from VHR data can capture heterogeneous fire patterns at fine spatial scales over the large spatial extents. This is important since most ecological processes associated with fire effects vary at the < 30 m scale and VHR approaches could significantly advance our ability to characterize fire effects on forest ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Subtask 7.4 - Power River Basin Subbituminous Coal-Biomass Cogasification Testing in a Transport Reactor

The U.S. Department of Energy (DOE) National Energy Technology Laboratory Office of Coal and Environmental Systems has as its mission to develop advanced gasification-based technologies for affordable, efficient, zero-emission power generation. These advanced power systems, which are expected to produce near-zero pollutants, are an integral part of DOE's Vision 21 Program. DOE has also been developing advanced gasification systems that lower the capital and operating costs of producing syngas for chemical production. A transport reactor has shown potential to be a low-cost syngas producer compared to other gasification systems since its high-throughput-per-unit cross-sectional area reduces capital costs. This work directly supports the Power Systems Development Facility utilizing the Kellogg Brown and Root transport reactor located at the Southern Company Services Wilsonville, Alabama, site. Over 3600 hours of operation on 17 different coals ranging from bituminous to lignite along with a petroleum coke has been completed to date in the pilot-scale transport reactor development unit (TRDU) at the Energy & Environmental Research Center (EERC). The EERC has established an extensive database on the operation of these various fuels in both air- and oxygen-blown modes utilizing a pilot-scale transport reactor gasifier. This database has been useful in determining the effectiveness of design changes on an advanced transport reactor gasifier and for determining the performance of various feedstocks in a transport reactor. The effects of different fuel types on both gasifier performance and the operation of the hot-gas filter system have been determined. It has been demonstrated that corrected fuel gas heating values ranging from 90 to 130 Btu/scf have been achieved in air-blown mode, while heating values up to 230 Btu/scf on a dry basis have been achieved in oxygen-blown mode. Carbon conversions up to 90% have also been obtained and are highly dependent on the oxygen-coal ratio. Higher-reactivity (low-rank) coals appear to perform better in a transport reactor than the less reactive bituminous coals. Factors that affect TRDU product gas quality appear to be coal type, temperature, and oxygen/fuel ratios. During this series of tests, a previously tested baseline Powder River Basin (PRB) subbituminous coal from the Peabody Energy North Antelope Rochelle Mine near Gillette, Wyoming was mixed with 20 wt% biomass. Two types of biomass were used - wood waste and switchgrass. Gas and particulate sampling at several locations in the riser provided information on coal devolatilization and cracking chemistry as a function of residence time, transport gas, and mode of operation. The goal of these tests was to compare the operating data and sample chemistry of the coal-biomass mixture to the PRB coal, with a focus on Fischer-Tropsch coal-to-liquid production in oxygen-blown mode. Data are to be provided to DOE to determine kinetic rates of devolatilization and tar cracking.

01 COAL, LIGNITE, AND PEAT↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WHONDRS River Corridor Sediment and Water Geochemistry and In Situ Sensor Data from Machine-Learning-Informed Sites across the Contiguous United States (v6)

This dataset supports a broader study examining hyporheic zone respiration rates to improve predictive models at a contiguous United States (CONUS) scale. The CONUS-Scale Model-Sample Study (CM) was designed following ICON (integrated, coordinated, open, and networked) principles to facilitate a model-experiment (ModEx) iteration approach, leveraging crowdsourced sampling across the CONUS. New machine learning models were created every month to guide sampling locations. Data from the resulting samples were used to test and rebuild the machine learning models for the next round of sampling guidance. Sampling began in April 2022 and ended in October 2023. In addition to the widely distributed CONUS sites, a more spatially focused sampling occurred in the Yakima River Basin, WA in summer 2022. Data from this more spatially intensive sampling occurred under the label “Second Spatial Study (SSS)” and were also included in the machine learning models. Other data types collected from SSS that were not part of CM were published in a separate data package (https://data.ess-dive.lbl.gov/view/doi:10.15485/1969566). This data package was originally published in February 2023. It was updated in June 2023 (v2; new and modified files); December 2023 (v3; new and modified files); June 2024 (v4; new and modified files); April 2024 (v5; new and modified files); and September 2025 (v6; modified files). See the change history section in the readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of two folders of field photos and videos, one folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data and one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) readme; (5) international generic sample number (IGSN) mapping file; (6) field protocols; (7) a subfolder with sample data; and (8) a subfolder with sensor data. The sample data subfolder contains (1) surface water and sediment dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) surface water and sediment total nitrogen data and averages; (3) surface water major cations and anions and averages; (4) sediment grain size data; (5) sediment iron (II) data and averages; (6) wet sediment mass, dry sediment mass, water mass, and wet sediment volume in incubation and sediment ICR vials; (7) sediment incubation respiration rate data and averages; (8) normalized respiration rate data and averages; (9) methods codes; (10) sediment specific surface area; (11) sediment percent carbon and nitrogen; (12) sediment gravimetric moisture and averages; (15) sediment X-ray diffraction (XRD) data; (16) sediment adenosine triphosphate (ATP) and averages; (17) a subfolder with sediment incubation respiration data, scripts, and plots; (18) surface water and sediment FTICR methods; and (19) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains five subfolders, one containing the sediment .xml data files, one containing the water .xml files, one containing the sediment CoreMS output files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS).The sensor data subfolder contains (1) a subfolder with miniDOT dissolved oxygen and temperature data and plots; (2) miniDOT dissolved oxygen and temperature summary data; and (3) miniDOT installation methods. All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4. CORRECTION: Carbon and nitrogen content are reported as percentages. The current column headers "01395_C_percent_per_mg" and "01397_N_percent_per_mg" are incorrect. These should read "01395_C_percent" and "01397_N_percent" and will be corrected in the next version of this data package. We thank the United States Forest Service, Washington Department of Fish and Wildlife, Washington Department of Natural Resources, Cowiche Canyon Conservatory, Washington State Parks and Recreation Commission (Scientific Research Permit #210901), and the Confederated Tribes and Bands of the Yakama Nation for access to field locations where the samples labeled “SSS” were collected. We also thank the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview. WHONDRS consortium members were asked to provide any acknowledgments for the collection of samples labeled “CM” and the following is a list of acknowledgments that were submitted with their corresponding Site IDs: (MART) Research activities were conducted in part on the Wind River Experimental Forest within the Gifford Pinchot National Forest; (MP- 100379) Philadelphia is part of Lenapehoking, the ancestral homelands of the Lenape peoples; (MP-102398) Land surveyed is the ancestral homelands of the Nookhose'iinenno (Arapaho), Tsis tsis'tas (Cheyenne), and Nuuchu (Ute); (MP-100749 and MP- 100747) Georgia Coastal Ecosystem LTER, OCE-1832178; (SP-70 and SP-72) Eastern Shoshone, Shoshone-Bannock; (MP- 102944) Funded by Oregon Watershed Enhancement Board. On the traditional lands of the Confederated Tribes of the Siletz, Confederated Tribes of the Grand Rhonde, and the Clatsop-Nehalem Confederated Tribe; (MP- 100607) Holiday Creek is located on the traditional territory of the Monacan Indian Nation; (SP-45) Lafayette Blue Springs State Park; (MP-102420) NSF DEB-2016749; (MP-100019) New Hampshire Agriculture Experiment Station; (SP-35) Rayonier (land owner; https://www.rayonier.com/); (MP- 101276) US Department of Energy, Office of Science, Biological and Environmental Research, Subsurface Biogeochemical Research, Watershed Dynamics and Evolution SFA at ORNL; (MP- 103224) Watershed Dynamics and Evolution SFA at ORNL; (MP- 101584) Traditional lands of the Oceti Sakowin (Dakota, Lakota, Nakoda) and Anishinaabe Peoples.

54 ENVIRONMENTAL SCIENCES↗

Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)

Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems, sensors, and communication technologies for demand response and load factor control applications for the residential sector. The purpose is to cover the gaps that exist in the information captured by the sensors for energy management system to be able to provide demand response and load factor control. The vision is the development of an energy management system or other controlling enterprise hardware and software that is not only able to control loads, PHEVs, and renewable generation for demand response and load factor control, but also to do so with consumer comforts in mind and in an optimal fashion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

pop-cosmos : redshifts and physical properties of KiDS-1000 galaxies

ABSTRACT Principled Bayesian inference of galaxy properties has not previously been performed for wide-area weak-lensing surveys with millions of sources. We address this gap by applying the pop-cosmos generative model to perform spectral energy distribution (SED) fitting for 4 million KiDS (Kilo-Degree Survey)-1000 galaxies. Calibrated on deep COSMOS2020 photometric data, pop-cosmos specifies a physically motivated prior over the galaxy population up to $z \simeq 6$ in stellar population synthesis (SPS) parameter space. Using the Speculator SPS emulator with GPU (graphics processing unit)-accelerated Markov Chain Monte Carlo sampling, we perform full posterior inference at 8.2 GPU seconds per galaxy, obtaining joint constraints on galaxy redshifts and physical properties. We validate photometric redshifts against $\sim \!185\,\!000$ KiDS galaxies cross-matched to Dark Energy Spectroscopic Instrument Data Release 1 spectroscopic samples, achieving low bias ($2\times 10^{-3}$), scatter ($\sigma _{\mathrm{MAD}}=0.03$), and outlier fraction (3.2 per cent) for the Bright Galaxy Survey, with comparable performance (bias $3\times 10^{-2}$, $\sigma _{\mathrm{MAD}}=0.05$, 1.0 per cent outliers) for luminous red galaxies (LRGs). Within the LRG sample, we identify massive, dusty, star-forming contaminants at $z \simeq 0.4$ satisfying standard colour selections for quenched populations. We infer trends in stellar mass, star formation, metallicity, and dust across five tomographic redshift bins consistent with established scaling relations. Using specific star formation rate constraints, we identify $\sim$7 per cent of KiDS-1000 galaxies as quenched, versus 37 per cent implied by conservative colour cuts. This enables the construction of weak-lensing samples defined by physical properties while mitigating intrinsic alignment systematics and preserving statistical power. Our analysis validates pop-cosmos out of sample, establishing it as a scalable approach for galaxy evolution and cosmological analyses with photometric surveys.

Halder, Anik [Institute of Astronomy and Kavli Ins↗

Developing a Reduced 240-Bus WECC Dynamic Model for Frequency Response Study of High Renewable Integration

The ongoing changes in the generation resource mix, driven by the rapid adoption of inverter-based resources (IBR) as well as the early retirement of synchronous generators, are bringing new challenges to the planning and operation of bulk electric power systems. Consequently, there is an increasing need to understand, design, and quantify the reliability service provision from IBRs by performing integrated scheduling and dynamic simulations. However, test systems that have consistent scheduling and dynamic models rarely exist largely because of the decoupled nature of the two simulations on a synchronous generator-dominated system. This paper develops the dynamic model of a reduced Western Electricity Coordinating Council (WECC) system. In conjunction with the existing scheduling model, it is suitable for integrating scheduling and dynamic simulations. The reduced 240-bus WECC model reflects the generation resource mix of the Western Interconnection as of 2018. Moreover, the developed dynamic model is validated against field frequency events measured by FNET/GridEye and preserves the dominant inter-area oscillation mode in WECC.

dynamic simulation↗

WE-A-16A-01: International Medical Physics Symposium: Increasing Access to Medical Physics Education/Training and Research Excellence

In response to a world in which cancer is a growing global health challenge, there is now a greater need for US Medical Physicists and other Radiation Oncology professionals across institutions to work together and be more globally engaged in the fight against cancer. There are currently many opportunities for Medical Physicists to contribute to alleviating this pressing need, especially in helping enhance access to Medical Physics Education/training and Research Excellence across international boundaries, particularly for low and middle-income countries (LMIC), which suffer from a drastic shortage of accessible knowledge and quality training programs in radiotherapy. Many Medical Physicists are not aware of the range of opportunities that even with small effort could have a high impact. Faculty at the two CAMPEP-accredited Medical Physics Programs in New England: the University of Massachusetts Lowell and Harvard Medical School have developed a growing alliance to increase Access to Medical Physics Education/training and Research Excellence (AMPERE), and facilitate greater active involvement of U.S. Medical Physicists in helping the global fight against cancer and cancer disparities. In this symposium, AMPERE Alliance members and partners from Europe and Africa will present and discuss the growing global cancer challenge, the dearth of knowledge, research, and other barriers to providing life-saving radiotherapy in LMIC, mechanisms for meeting these challenges, the different opportunities for participation by Medical Physicists, including students and residents, and how participation can be facilitated to increase AMPERE for global health. Learning Objectives: To learn about the growing global cancer challenge, areas of greatest need and limitations to accessing knowledge and quality radiotherapy training programs, especially in LMIC; To learn about the range of opportunities for Medical Physicists, including students and residents, to work together in global health to help increase AMPERE and alleviate the growing global burden of cancer; To present and discuss a new model for harmonizing Medical Physics Training across countries and how this model (UMass and Heidelberg) could be extended to LMIC in collaboration with the IAEA; To highlight a new platform and program for facilitating contributions by Medical Physicists to increase AMPERE towards the elimination of global cancer disparities. Challenges in Cancer Control in Africa Twalib A. Ngoma, MD, Professor, Executive Director, Ocean Road Cancer Institute, Dar Es Salaam, Tanzania Cancer care in Africa is beset by lack of attention, political will, cancer registries, cancer plans, human resources, financial resources and treatment facilities.. As a result of this, cancer patients in Africa are far more likely to die of their disease than those in developed countries. According to data from the WHO 750,000 new cancer cases occur in Africa every year and this number is predicted to rise by 70% by 2020. To make matters worse, an estimated 75% of cancer patients in Africa have advanced or incurable cancers at diagnosis making palliative care the most realistic approach to their management. Furthermore, Cancer prevention is nearly nonexistent, cancer detection is rare and treatment usually comes too late and is inefficient. The overall mortality-to-incidence ratio for men with cancer in the Africa is 0.75 compared with 0.54 in the developed world while the ratios for women in Africa, is 0.65 compared with 0.45 for women in the developed world. There is also limited access to radiotherapy. According to the International Atomic Energy Agency (IAEA), whilst developed countries usually have one radiotherapy machine per 250,000 people, most African nations have only one machine per ten million people. The above numbers are alarming and speak for themselves. The only solution to improve this alarming situation is to address the major challenges which African countries face in provision of cancer services which include but not limited to lack of cancer registries, lack of funding, lack of human resources, lack of radiotherapy machines, lack of cancer drugs and lack of accessible and affordable cancer screening, early diagnosis, treatment or palliative care services. Since there are considerable differences among African countries, in my presentation I will share with the audience how we address cancer control challenges in Tanzania in general and specifically in radiation oncology. The African continent cancer plan 2013 2017 Folakemi Odedina, PhD, Professor and Director of Health Disparities, UF Health Cancer Center, University of Florida The burden of cancer is rising in Africa, in addition to current heavy burden of communicable, and other non-cancer related non—communicable diseases. Conquering cancer in Africa will require a comprehensive collaborative approach with cancer clinicians, scientists, patients, advocates, policy makers and community leaders working hand-in-hand at the local, state, national, and continent levels with the primary mission: To reduce the number of deaths from cancer and improve the quality of life of cancer patients, survivors and caregivers. Unfortunately, less than 40% of African countries have a credible cancer control policy and program. The African Organization for Research and Training in Cancer (AORTIC) decided to create an African Cancer Plan to provide cost-effective strategies that can be employed throughout the continent to fight cancer. Based on the African proverb that “It takes a village to raise a child”, the Cancer Plan provides specific strategies that can be used by individuals, employers, organizations and policy-makers to fight cancer. In addition, we have provided overarching strategies to address cancer in Africa and targeted 5-year plan for prostate, breast, cervix, lung and liver cancers. In developing this Cancer Plan, our primary goal is to decrease cancer incidence and mortality in Africa. This goal can only be achieved by stakeholders and dedicated individuals to lead and implement the strategies outlined in this plan. If you are interested in partnering with AORTIC to reduce the burden of cancer in Africa, please send an email to info@aortic-africa.org. Synergies in research and clinical care through international collaboration Thomas Bortfeld and David Gierga, Massachusetts General Hospital, Harvard Medical School, MA Medical Physics relies on high technology that is not distributed equally. The whole spectrum of Medical Physics technologies is not available at every hospital or research institute, and not even in every high income country. One example is heavy ion therapy equipment which is currently only available in Japan, Germany and Italy. There is also a large global variation in terms of research infrastructure and focus. A student of Medical physics cannot gain broad experience, certainly not hands-on experience, by staying at one place only. While it is debatable what a good trade-off between breadth and depth in Medical Physics education is, it is generally agreed upon that some breadth is necessary. Researchers in Medical Physics have to cross borders if they need specific technologies for their projects. Therefore it is self-evident that international programs in Medical Physics education and research make sense. Yet, very few programs of this type exist. In this presentation we will report on our own experience of pursuing an international career in Medical Physics, with international student programs, and with the international exchange of researchers. We will present new or planned opportunities such as the medical beamline at CERN in Geneva. We will also report on the synergies in clinical care through international collaborations between partners in high and low income countries. One example is the partnership of the MGH/Harvard Medical School community with the oncology community and government of Botswana to form the BOTSOGO (BOTSwana Oncology Global Outreach) initiative. This collaborative effort in oncology care was spurred by existing relationships in HIV/AIDS research and care delivery developed within the Botswana-Harvard AIDS Institute Partnership (BHP). The initial efforts of the BOTSOGO initiative have been organized as follows: 1) on-site visits to share expertise in clinical cancer care for capacity building purposes (e.g. cervical brachytherapy), 2) developing a forum for multi-disciplinary case discussions and education and 3) relationship building with local stakeholders for long-term sustainability and growth. An international system for the certification of medical physicists Raymond K. Wu, Chairman, IOMP Professional Relations Committee; Chairman, AAPM Exchange Scientist Program Subcommittee An international system for the certification of medical physicists is an important issue. The International Organization for Medical Physicists (IOMP) has in collaboration with a number of member countries established the International Medical Physics Certification Board (IMPCB) to address this issue, and to provide a mechanism to mark the milestone for the professional development of clinical medical physicists. Raymond Wu, PhD, is the CEO of IMPCB and the Chairman of the IOMP Professional Relations Committee. He is the invited speaker recommended by IOMP to give a talk on this important subject. He will give the latest update of the work of IMPCB, its near term goals, and pathways to the goals. He will also discuss the importance of such an International System of certification in the training/education of next generation Medical Physicists, including those in low and middle income countries (LMIC) where such training is crucial in the fight against cancer. Learning Objectives: Understand the certification program as described in the IOMP Policy Statements. Understand the plan of the IMPCB to establish the accreditation process of national certification programs. Understand the goals of this international collaborative effort and the potential impacts to the quality of clinical medical physics practice. Medical Physics Education Across Continents: The UMass Lowell and Heidelberg University Joint Coordination Effort Erno Sajo, Director of Medical Physics, University of Massachusetts at Lowell Medical Physics education has unique flavors across institutions within the US and shows significant differences across continents. In the latter, even the definition of Medical Physics may differ. Not only is there a difference in topical coverage, but often what is considered a cohesive topic in one institution, and taught as a single course, is fragmented among several other courses in the other institution due to a different philosophy. Because of the regulatory and certification requirements, these differences impact the mobility of medical physicists across continents. As a result, physicists who wish to practice in the US or Canada but have completed their education elsewhere often find that they have to take remedial courses or even obtain a new degree in Medical Physics despite the fact that they already have one. Outreach to developing countries, therefore, is even more difficult. The University of Massachusetts Lowell and Heidelberg University recently completed a joint coordination effort, in which they identified topics that are common versus complementary in their medical physics curricula. A student exchange program was developed that permits students to take any of the common topics at the other institution while taking complementary courses as electives, which count towards their degree requirements at their home institution. Thesis research is also mutually accepted. When properly documented, in this way CAMPEP recommendations can be met across the institutions. Therefore, students participating in this program satisfy both the American Board of Radiology (ABR) requirements and the European regulatory requirements. The framework on which this collaboration rests and the cross-comparison methods developed therein may be implemented in other exchange programs and thus a similar approach can be adopted in outreach programs with developing countries. IAEA PACT Program and opportunities for support and collaboration Susan Morgan, Program Coordinator, International Atomic Energy Agency, Vienna, Austria In response to the developing world's cancer crisis, the International Atomic Energy Agency (IAEA) established the Program of Action for Cancer Therapy (PACT) in 2004 to fully realize the public health impact obtained through global partnerships in cancer control and technology transfer in radiation medicine. PACT's vision strives for global partnerships to confront the cancer crisis in developing countries, notably with our sister United Nations agency, the World Health Organization (WHO), and our Joint Programme on Cancer Control established in 2009. The IAEA, through PACT, the WHO, the International Agency for Research on Cancer (IARC) and other cancer-related organizations work together to make a coordinated global response in supporting low and middle income (LMI) IAEA Member States in the implementation of comprehensive national cancer control programmes. PACT's goals are: To build global partnerships of cancer-related organizations committed to addressing the challenge of cancer in LMI Member States in all its aspects; To mobilize resources from charitable trusts, foundations, and others in public and private sectors sources to assist LMI Member States to develop and implement their radiation medicine capacities within a national cancer control programme (NCCP); and, To ensure the effective and sustainable transfer of radiation medicine technologies or knowledge to all LMI Member States where unmet needs exist. PACT work focuses on: imPACT: Assessing Cancer Burden PMDS: Developing Global Partnerships VUCCnet: Promoting Cancer Control Training AGaRT: Making Radiotherapy Accessible Facilitating increased participation and professional development of Medical Physicists and other Radiation Oncology professionals in global health Wilfred Ngwa, Harvard Medical School, University of Massachusetts Lowell, MA The 2014 World Health Organization (WHO) Cancer report highlights an alarming increase in the global burden of cancer. It also highlights what it terms “the cancer divide”, or disparities, evinced by a substantially higher cancer burden in low and middle income countries (LMIC) in Asia, Central/South America and Africa. The WHO even predicts a potential African cancer epidemic by 2020 if significant progress is not made in global cancer control efforts. Evidence that collaborative global health approaches have led to major progress in controlling infectious diseases including in LMIC suggests that similar approaches will be useful for non-communicable diseases like cancer. In consonance with this, leaders in cancer policy from the USA and 14 economically diverse countries recently concluded that successful campaigns to control cancers with existing methods and to improve current strategies will increasingly depend onconcerted multinational collaborations (Sci Transl Med 5, p. 175, 2013). Hence there is growing urgency for increasing collaborative global cancer Care Research and Education (CaRE), as well as support for greater effectiveness of already existing initiatives involving partners from different nations, diverse economic and cultural backgrounds. The good news is that there is a growing awareness of the importance of global health and growing interest including amongst Medical Physicists and other Radiation oncology (RadOnc) professionals to participate in global health. However, many are unaware of currently existing opportunities for participation that even with small effort could have a high impact. Over 50% of cancer patients in the developed world depend on RadOnc professionals for their treatment, and hence participation of RadOnc professionals in global health efforts in the global fight against cancer is crucial. It is also important that the next generation of RadOnc professionals (students, and residents) be trained with a global perspective, to be global health leaders in cancer CaRE. This presentation will highlight a novel platform for enhancing participation and professional development of Medical Physicists and other RadOnc professionals in global health. Ways in which this platform can facilitate contributions by Medical Physicists and other RadOnc Professionals, students and residents in global health towards the elimination of global cancer disparities will be discussed. This will be followed by a panel discussion by some of the pioneers/leaders in collaborative global cancer CaRE on the growing cancer burden, challenges and opportunities for greater active involvement and professional development.

60 APPLIED LIFE SCIENCES↗

Analysis of Unit-Level Changes in Operations with Increased SPP Wind from EPRI/LCG Balancing Study

Wind power development in the United States is outpacing previous estimates for many regions, particularly those with good wind resources. The pace of wind power deployment may soon outstrip regional capabilities to provide transmission and integration services to achieve the most economic power system operation. Conversely, regions such as the Southeastern United States do not have good wind resources and will have difficulty meeting proposed federal Renewable Portfolio Standards with local supply. There is a growing need to explore innovative solutions for collaborating between regions to achieve the least cost solution for meeting such a renewable energy mandate. The Department of Energy funded the project 'Integrating Midwest Wind Energy into Southeast Electricity Markets' to be led by EPRI in coordination with the main authorities for the regions: SPP, Entergy, TVA, Southern Company and OPC. EPRI utilized several subcontractors for the project including LCG, the developers of the model UPLAN. The study aims to evaluate the operating cost benefits of coordination of scheduling and balancing for Southwest Power Pool (SPP) wind transfers to Southeastern Electric Reliability Council (SERC) Balancing Authorities (BAs). The primary objective of this project is to analyze the benefits of regional cooperation for integrating mid-western wind energy into southeast electricity markets. Scenarios were defined, modeled and investigated to address production variability and uncertainty and the associated balancing of large quantities of wind power in SPP and delivery to energy markets in the southern regions of the SERC. DOE funded Oak Ridge National Laboratory to provide additional support to the project, including a review of results and any side analysis that may provide additional insight. This report is a unit-by-unit analysis of changes in operations due to the different scenarios used in the overall study. It focuses on the change in capacity factors and the number of start-ups required for each unit since those criteria summarize key aspects of plant operations, how often are they called upon and how much do they operate. The primary analysis of the overall project is based on security-constrained unit commitment (SCUC) and economic dispatch (SCED) simulations of the SPP-SERC regions as modeled for the year 2022. The SCUC/SCED models utilized for the project were developed through extensive consultation with the project utility partners, to ensure the various regions and operational practices are represented as best as possible in the model. SPP, Entergy, Oglethorpe Power Company (OPC), Southern Company, and the Tennessee Valley Authority (TVA) actively participated in the project providing input data for the models and review of simulation results and conclusions. While other SERC utility systems are modeled, the listed SERC utilities were explicitly included as active participants in the project due to the size of their load and relative proximity to SPP for importing wind energy.

17 WIND ENERGY↗

LLNL Kimberlina 1.2 NUFT Simulations June 2018 (v2)

This dataset contains the output 6,000, 3-dimensional reactive multi-phase flow and transport aquifer simulations of brine and CO2 leakage into a protective aquiver in California’s San Joaquin Valley and input data files detailing the geologic mesh, aquifer physical properties and CO2 and brine injection rates. This data set was generated as an ongoing effort with the US DOE National Risk Assessment Partnership (NRAP) to evaluate the effectiveness of monitoring techniques to detect brine and CO2 leakage from legacy wells into underground sources of drinking water overlaying a CO2 storage reservoir. Each simulation contains a unique set of input parameters, generated stochastically. The outputs consist of these upper three geologic layers (from top): the Etchegoin, Macoma-Chanac, Santa Margarita-McLure formations. These simulations span the several distances (1, 3 and 6 km or wells W31-0.2, W31-0.5 and W31-1.0, respectively) from the CO2 injector, initiated from bottom hole pressure and saturation to calculate wellbore leakage from the storage reservoir, with low and high regional groundwater gradients and wellbore leakage into 5 leaky nodes. The dataset includes 1,000 unique simulations for each distance, which each contain a unique aquifer heterogeneity, aquifer and caprock permeability, and two model generations are included with a high permeability (prod07) and hybrid permeability (prod09). The range of permeability distributions is listed in Table 1. Each model generation consists of 3,000 simulations. Included in the dataset are the leakage rates determined from 2D wellbore models which utilize the pressure and CO2 saturation from LBL's reservoir simulations, NUFT mesh files with distributed lithology, NUFT rocktab files which describe the material properties for the geologic layers and the NUFT input files and post-processed output 'ntab' files. Each ntab file contains spatial (rows) and temporal (columns) model output tables for each model cell, the locations (x,y,z) and dimensions for each cells (dx, dy, dz). Table 1. Permeability distribution ranges for prod07 and prod09 model generations Geologic Layer: Permeability Range (log10 m^2) prod07 prod09 Etchegoin -12.92 to -10.92 -13.70 to -11.44 Macoma-Chanac -12.72 to -10.72 -13.50 to -11.24 Santa Margarita-McLure -12.70 to -10.70 -13.48 to -11.22 The input files used to generate the model include which are included in the dataset are: Time series of CO2 leakage input into the model (ex: Q_brn.W31-0.2.sim1000.layers123.tab) Time series of CO2 leakage input into the model (ex: Q_CO2.W31-0.2.sim1000.layers123.tab) Physical properties of the aquifer materials detailing the aquifer porosity, solid density, partitioning coefficients, permeabilities and van-Genuchten parameters detailed in a NUFT rocktab file: (ex: sim1000.usnt.rocktab) Numerical mesh and geologic data assigned to each model cell detailed in a NUFT genmsh format (ex: sim1000.mesh_k16.prod07.trans.genmsh) The primary output parameters are: pH (use absolute value) Change in TDS (mg/kg) Change in Pressure (Pa) Change CO2 gas saturation (fraction range 0.0-1.0) for example, the directory /p/lscratchh/mansoor1/nrap/kimberlina/prod09/mainfiles/sim1000/W31- 0.2 contains: sim1000.W31-0.2.trans.pH.red.ntab sim1000.W31-0.2.no_bg.trans.TDS.red.ntab sim1000.W31-0.2.usnt.P.deltabg.red.ntab sim1000.W31-0.2.usnt.CO2_sat.deltabg.red.ntab Each row in the NTAB files consist of model output per numerical grid cell. Each output file contains 33 columns (variables), including the information of numerical records, geologic location and sizes and the simulated parameter values over time. The first 13 variables are about numerical records and relative geologic information for a simulation grid: 1. index: simulation index 2. i: the ith grid of x-axis 3. j: the ith grid of y-axis 4. k: the ith grid of z-axis 5. element_ref: element reference 6. nuft_ind: nuft index 7. x: grid location in the x axis direction 8. y: grid location in the y axis direction 9. z: grid location in the z axis direction 10. dx: grid length in the x axis direction 11. dy: grid length in the y axis direction 12. dz: grid length in the z axis direction 13. volume: volume of the simulation grid The remainder (14, 15, 16...) variables are the simulated parameter values over time, take Pressure as an example, are: 14. 0.0y: initial pressure per cell. 15. 10.0y: simulated pressure at the end of the 10th year. 16. 20.0y: simulated pressure at the end of the 20th year. ... (repeated for every 10 years until 200 years)... The model extends 10,000 m, 5,000 m and 1,411 m in the x,y and z dimensions, respectively. The mesh consists of 164,832 cells with mesh dimensions of 101 x 51 x 32 (nx, ny, nz), with cell dimensions ranging from 100 m laterally (along x and y-axis) and model layers are as designated in the z-axis: Layer 1: atmosphere (1e-30 m thick) Layer 2: upper caprock (10 m thick) Layers 3-13: Etchegoin (536.23 m thck) Layers 14-27: Macoma-Chanac (679.04 m thick) Layers 28-32: Santa Margarita-McLure (185.94 m thick) The wellbore is placed along node i=51, j=26, and extends vertically along 5 nodes from the top to the bottom of the model. Special instructions when extracting files: Each Gzip archive (ex: prod07.sim1000-sim00099.tar.gz) contains 100 simulations. Gzip archives should be transferred into base directories (ie. In Linux: mkdir prod07; mv prod07.*.tar.gz prod07/.) before extracting, or files will be overwritten. Each sub-simulation tree should have the following file structure pattern (using the linux 'tree' command): |-- prod07 | |-- sim0001 | |-- W31-0.2 | | |-- Q_brn.W31-0.2.sim0001.layers123.tab | | |-- Q_co2.W31-0.2.sim0001.layers123.tab | | |-- sim0001.W31-0.2.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-0.2.trans.pH.red.ntab | | |-- sim0001.W31-0.2.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-0.2.usnt.P.deltabg.red.ntab | |-- W31-0.5 | | |-- Q_brn.W31-0.5.sim0001.layers123.tab | | |-- Q_co2.W31-0.5.sim0001.layers123.tab | | |-- sim0001.W31-0.5.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-0.5.trans.pH.red.ntab | | |-- sim0001.W31-0.5.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-0.5.usnt.P.deltabg.red.ntab | |-- W31-1.0 | | |-- Q_brn.W31-1.0.sim0001.layers123.tab | | |-- Q_co2.W31-1.0.sim0001.layers123.tab | | |-- sim0001.W31-1.0.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-1.0.trans.pH.red.ntab | | |-- sim0001.W31-1.0.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-1.0.usnt.P.deltabg.red.ntab | |-- sim0001.mesh_k16.prod07.trans.genmsh Disclaimer This document was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor Lawrence Livermore National Security, LLC, nor any of their employees makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or Lawrence Livermore National Security, LLC. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or Lawrence Livermore National Security, LLC, and shall not be used for advertising or product endorsement purposes. Lawrence Livermore National Laboratory is operated by Lawrence Livermore National Security, LLC, for the U.S. Department of Energy, National Nuclear Security Administration under Contract DE-AC52-07NA27344. This report was reviewed and released as LLNL-MI-753464.

aquifer↗

Modifications to Solar Titan-130 Combustion Systems for Efficient, High Turndown Operation

The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Dramatic Demand Reduction In The Desert Southwest

This report summarizes a project that was funded to the University of Nevada Las Vegas (UNLV), with subcontractors Pulte Homes and NV Energy. The project was motivated by the fact that locations in the Desert Southwest portion of the US demonstrate very high peak electrical demands, typically in the late afternoons in the summer. These high demands often require high priced power to supply the needs, and the large loads can cause grid supply problems. An approach was proposed through this contact that would reduce the peak electrical demands to an anticipated 65% of what code-built houses of the similar size would have. It was proposed to achieve energy reduction through four approaches applied to a development of 185 homes in northwest part of Las Vegas named Villa Trieste. First, the homes would all be highly energy efficient. Secondly, each house would have a PV array installed on it. Third, an advanced demand response technique would be developed to allow the resident to have some control over the energy used. Finally, some type of battery storage would be used in the project. Pulte Homes designed the houses. The company considered initial cost vs. long-term savings and chose options that had relatively short paybacks. HERS (Home Energy Rating Service) ratings for the homes are approximately 43 on this scale. On this scale, code-built homes rate at 100, zero energy homes rate a 0, and Energy Star homes are 85. In addition a 1.764 Wp (peak Watt) rated PV array was used on each house. This was made up of solar shakes that were in visual harmony with the roofing material used. A demand response tool was developed to control the amount of electricity used during times of peak demand. While demand response techniques have been used in the utility industry for some time, this particular approach is designed to allow the customer to decide the degree of participation in the response activity. The temperature change in the residence can be decided by the residents by adjusting settings. In a sense the customer can choose between greater comfort and greater money savings during demand response circumstances. Finally a battery application was to be considered. Initially it was thought that a large battery (probably a sodium-sulfur type) would be installed. However, after the contract was awarded, it was determined that a single, centrally-located battery system would not be appropriate for many reasons, including that with the build out plan there would not be any location to put it. The price had risen substantially since the budget for the project was put together. Also, that type of battery has to be kept hot all the time, but its use was only sought for summer operation. Hence, individual house batteries would be used, and these are discussed at the end of this report. Many aspects of the energy use for climate control in selected houses were monitored before residents moved in. This was done both to understand the magnitude of the energy flows but also to have data that could be compared to the computer simulations. The latter would be used to evaluate various aspects of our plan. It was found that good agreement existed between actual energy use and computed energy use. Hence, various studies were performed via simulations. Performance simulations showed the impact on peak energy usage between a code built house of same size and shape compared to the Villa Trieste homes with and without the PV arrays on the latter. Computations were also used to understand the effect of varying orientations of the houses in this typical housing development, including the effect of PV electrical generation. Energy conservation features of the Villa Trieste homes decreased the energy use during peak times (as well as all others), but the resulting decreased peak occurred at about the same time as the code-built houses. Consideration of the PV generation decreases the grid energy use further during daylight hours, but did not extend long enough many days to decrease the peak. Hence, a demand response approach, as planned, was needed. With participation of the residents in the demand response program developed does enable the houses to reduce the peak demand between 66% and 72%, depending on the built years. This was addressed fully in the latter part the study and is described in the latter part of this report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Vera C. Rubin Observatory Data Preview 1

We present Rubin Data Preview 1 (DP1), the first data from the National Science Foundation–Department of Energy Vera C. Rubin Observatory, comprising raw and calibrated single-epoch images, coadds, difference images, detection catalogs, and ancillary data products. DP1 is based on 1792 optical–near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera (LSSTComCam) on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile in late 2024. DP1 covers ∼15 deg 2 distributed across seven roughly equal-sized noncontiguous fields, each independently observed in six broad photometric bands, ugrizy. The median FWHM of the point-spread function across all bands is approximately 1"14, with the sharpest images reaching about 0." 58. The 5σ point-source depths for coadded images in the deepest field, the Extended Chandra Deep Field South, are u = 24.55, g = 26.18, r = 25.96, i = 25.71, z = 25.07, and y = 23.1. Other fields are no more than 2.2 mag shallower in any band, where they have nonzero coverage. DP1 contains approximately 2.3 million distinct astrophysical objects, of which 1.6 million are extended in at least one band in coadds, and 431 solar system objects, of which 93 are new discoveries. DP1 is approximately 3.5 TB in size and is available to Vera C. Rubin Observatory data rights holders via the Rubin Science Platform, a cloud-based environment for the analysis of petascale astronomical data. While small compared to future LSST releases, its high quality and diversity of data support a broad range of early science investigations ahead of full operations in 2026.

Ground-based astronomy↗

DOE: Integrating Southwest Power Pool Wind Energy into Southeast Electricity Markets

Wind power development in the United States is outpacing previous estimates for many regions, particularly those with good wind resources. The pace of wind power deployment may soon outstrip regional capabilities to provide transmission and integration services to achieve the most economic power system operation. Conversely, regions such as the Southeastern United States do not have good wind resources and will have difficulty meeting proposed federal Renewable Portfolio Standards with local supply. There is a growing need to explore innovative solutions for collaborating between regions to achieve the least cost solution for meeting such a renewable energy mandate. The DOE-funded project 'Integrating Southwest Power Pool Wind Energy into Southeast Electricity Markets' aims to evaluate the benefits of coordination of scheduling and balancing for Southwest Power Pool (SPP) wind transfers to Southeastern Electric Reliability Council (SERC) Balancing Authorities (BAs). The primary objective of this project is to analyze the benefits of different balancing approaches with increasing levels of inter-regional cooperation. Scenarios were defined, modeled and investigated to address production variability and uncertainty and the associated balancing of large quantities of wind power in SPP and delivery to energy markets in the southern regions of the SERC. The primary analysis of the project is based on unit commitment (UC) and economic dispatch (ED) simulations of the SPP-SERC regions as modeled for the year 2022. The UC/ED models utilized for the project were developed through extensive consultation with the project utility partners, to ensure the various regions and operational practices are represented as accurately as possible realizing that all such future scenario models are quite uncertain. SPP, Entergy, Oglethorpe Power Company (OPC), Southern Company, and the Tennessee Valley Authority (TVA) actively participated in the project providing input data for the models and review of simulation results and conclusions. While other SERC utility systems are modeled, the listed SERC utilities were explicitly included as active participants in the project due to the size of their load and relative proximity to SPP for importing wind energy. The analysis aspects of the project comprised 4 primary tasks: (1) Development of SCUC/SCED model of the SPP-SERC footprint for the year 2022 with only 7 GW of installed wind capacity in SPP for internal SPP consumption with no intended wind exports to SERC. This model is referred to as the 'Non-RES' model as it does not reflect the need for the SPP or SERC BAs to meet a federal Renewable Energy Standard (RES). (2) Analysis of hourly-resolution simulation results of the Non-RES model for the year 2022 to provide project stakeholders with confidence in the model and analytical framework for a scenario that is similar to the existing system and more easily evaluated than the high-wind transfer scenarios that are analyzed subsequently. (3) Development of SCUC/SCED model of the SPP-SERC footprint for the year 2022 with sufficient installed wind capacity in SPP (approximately 48 GW) for both SPP and the participating SERC BAs to meet an RES of 20% energy. This model is referred to as the 'High-Wind Transfer' model with several different scenarios represented. The development of the High-Wind Transfer model not only included identification and allocation of SPP wind to individual SERC BAs, but also included the evaluation of various methods to allow the model to export the SPP wind to SERC without developing an actual transmission plan to support the transfers. (4) Analysis of hourly-resolution simulation results of several different High-Wind Transfer model scenarios for the year 2022 to determine balancing costs and potential benefits of collaboration among SPP and SERC BAs to provide the required balancing.

17 WIND ENERGY↗