Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DYNAMIC LOAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Conformational dynamics linked to domain closure and substrate binding explain the ERAP1 allosteric regulation mechanism

The endoplasmic-reticulum aminopeptidase ERAP1 processes antigenic peptides for loading on MHC-I proteins and recognition by CD8 T cells as they survey the body for infection and malignancy. Crystal structures have revealed ERAP1 in either open or closed conformations, but whether these occur in solution and are involved in catalysis is not clear. Here, we assess ERAP1 conformational states in solution in the presence of substrates, allosteric activators, and inhibitors by small-angle X-ray scattering. We also characterize changes in protein conformation by X-ray crystallography, and we localize alternate C-terminal binding sites by chemical crosslinking. Structural and enzymatic data suggest that the structural reconfigurations of ERAP1 active site are physically linked to domain closure and are promoted by binding of long peptide substrates. These results clarify steps required for ERAP1 catalysis, demonstrate the importance of conformational dynamics within the catalytic cycle, and provide a mechanism for the observed allosteric regulation and Lys/Arg528 polymorphism disease association.

59 BASIC BIOLOGICAL SCIENCES↗

A prediction model of failure threshold for shear deformation in a Zr-based bulk metallic glass

The failure of bulk metallic glasses (BMGs) during plastic deformation at room temperature is abrupt and instantaneous, while the analysis of precursor information based on avalanche events helps predict catastrophic failure. An acoustic emission (AE) signal can provide accurate precursor information for material failure, due to its sensitive and high fast calculation ability. In the current study, AE monitoring tests are carried out during uniaxial compression tests of BMGs at different strain rates. The AE experimental failure threshold, E max , is proposed on the basis of AE cumulative energy, which reflects the intensity of damage evolution at different loading conditions. Compared with the critical shear band velocity (CSBV) associated with stick-slip dynamics of serrated flow, E max is a more sensitive failure parameter since it is connected with the local microscopic changes that occur during the material response process. Here, the E max is obtained prior to reaching the CSBV since the calculation of these two avalanches analysis focuses on the different stages of shear band growth. In particular, AE events are related to the “dry” friction process in the first stage, however, the CSBV is responsible for the “viscous” glide in the second stage. Therefore, Emax is not affected by the complex interactions between the shear bands during the stick-slip process. The maximum avalanche of serrated flow, S max , is proposed as the experimental failure threshold, which depends on the applied strain rate as S max ~ $\dot{ε}$ –λ . According to the relationship of E max and S max , the theoretical failure threshold, E max , follows a criterion E max = 2545$\dot{ε}$ –λ - 4468, where λ is equivalent to 0.15 for this work. Finally, combining the different calculations and AE measurements, this model gives new insights to predict the deformation failure behavior of Zr-based BMGs.

36 MATERIALS SCIENCE↗

Modes of strain accommodation in Cu-Nb multilayered thin film on indentation and cyclic shear

Two-phase layered thin films with a high density of semi-coherent interfaces exhibit excellent mechanical properties and thermal stability. Here, in this study, a magnetron-sputtered Cu-Nb dual-layered thin film (~500 nm for Cu and ~150 nm for Nb) having an amorphous interface between Cu and Nb with a high density of aligned growth twins in Cu is subjected to severe surface deformation. The material is loaded using indentation and cyclic shear under tribological testing. The strain accommodation in the subsurface microstructure after deformation varies based on the local structure and deformation mode. Grain refinement and crack formations in the stressed region of the Nb layer and localized crystallization of the amorphous interface are observed after indentation and scratch testing. Pronounced detwinning of growth twins in the Cu layer under the cyclic shear strain leaves large dislocations sites and loops which are observed both by high-resolution transmission electron microscopy and experiment-guided molecular dynamic (MD) simulations. Our simulations provided insights into understanding the pathway for the detwinning process under cyclic shear loading.

36 MATERIALS SCIENCE↗

Assessing the impacts of wakes on floating wind farms with shared anchors

This paper examines wake effects for floating wind farms with shared anchors. Three 20-turbine farms are examined: a grid-formation baseline with no shared anchors, a farm based on 3-line anchors, and a farm based on 6-line anchors, governed by a wind turbine spacing of 8 rotor diameters. The IEA 15 MW reference turbine on the UMaine semisubmersible platform was used with a taut mooring system in deep- water depths representative of U.S. west coast lease areas. A steady-state wake model showed that, when evaluating a sweep of wind headings, the baseline design had the lowest wake losses, with a value of 11.7 %, followed by the 6-line at 12.9% and the 3-line at 13.8%. Dynamic simulations were run in FAST.Farm to analyse the effects of wakes on mean anchor loads for wind headings that showed significant wake losses. The baseline farm showed the largest anchor load reductions due to wake effects (up to 16%), followed by the 3-line farm (up to 8%), and the 6-line farm, which showed relatively consistent load magnitudes on the 6-line anchors across all headings.

17 WIND ENERGY↗

Geographically Distributed Co-Simulation for the Interplay of Integrated Energy Systems and Power Grid

The increased penetration of renewable generation induces unbalanced demand-supply on a power grid, while integrated energy systems (IES) can provide high part-load efficiency and high flexibility to support grid resilience. To study the transients and improve dynamic operability, it’s important to investigate the interplay between IES and power grid concurrently using real-time co-simulation approaches. In this presentation, we showed the previous co-simulation test between NETL and INL and discussed how this co-simulation can be beneficial for both IES and power grid research. In addition, we gave an overview about the SuperLab2.0 project, which was a federated national platform to address future power grid challenges. (Virtual presentation to the MILLENNIUM CLEAN and SUSTAINABLE POWER workshop 2025).

Co-simulation↗

Assessing the Optical Performance Impact of Tracking Error in an Operational Concentrated Solar Power Plant Using Monte Carlo Ray-Tracing Simulation

Concentrating Solar Power (CSP) provides firm and dispatchable electricity due to its thermal storage and hybridization capabilities, which supports the decarbonization of our energy supply. Of the various CSP technologies, parabolic trough collectors are the most mature, with over 500 MW operating worldwide. The optical performance of parabolic trough systems is sensitive to tracking error, which is defined as the angular offset of a collector away from the sun position in the transversal plane. Tracking error commonly occurs due to non-continuous adjustment of the trough angle to point toward the sun, but other factors such as gravity, heating, and wind loading can also contribute to tracking error. Researchers have explored the impact of tracking error on optical performance both numerically and experimentally, but existing studies do not include measurements from operational utility-scale power plants. Tilt angle measurements of parabolic troughs at operational utility-scale power plants illustrate spatial variations in optical performance and include various sources of tracking error such as gravity, heating, and wind loading. To fully characterize wind driven loads on parabolic troughs, we are conducting a long-term field measurement campaign at the Nevada Solar One CSP plant located in Boulder City, NV, which has a nominal capacity of 72 MW and 0.5 hours of full-load storage. We record load measurements on four outer trough rows, collecting support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Using the tilt measurements acquired at 20 Hz frequency, we calculate the deviation between the nominal sun position and the tracker angle. Using a Monte-Carlo ray-tracing simulation software, we assess the impact of the tracker angle deviation on optical performance throughout the diurnal cycle at various spatial locations within the CSP plant. In our view, this first-of-a-kind study will provide important guidance for future trough designs that reduce the impact of various sources of tracking error on performance.

concentrating solar power↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗

Molecular dynamics simulation of vacancy and void effects on strain-induced martensitic transformations in Fe-50 at.% Ni model concentrated solid solution alloy

Strain-induced martensitic transformations can improve the strength and ductility of some face centered cubic (FCC) metals and alloys. Irradiation-induced defects such as vacancies, dislocation loops, and voids activate martensitic transformations over a wider range of mechanical loading conditions than in pristine material. Furthermore, the mechanisms underlying irradiation-enabled martensite transformations remain unclear. In this work, we use molecular dynamics simulations to study the effect of vacancies and voids on strain-induced martensitic transformations in a model concentrated solid solution alloy Fe-50 at.% Ni. It has been found that single vacancies have no resolvable effect on the transformation because they reduce the stacking fault energy by a relatively insignificant margin and do so only if the vacancy is located on the stacking fault plane. Voids, however, activate the martensite transformation through shear strain accumulation around the void due to dislocation pileup. The larger the void, the more pronounced this effect.

36 MATERIALS SCIENCE↗

Molecular Dynamics Simulation Study of Uniaxial Ratcheting Behaviors for Ultrafine-Grained Nanocrystalline Nickel

In this paper, molecular dynamics (MD) simulation-based study of deformation behavior of ultrafine-grained nanocrystalline nickel under asymmetric cyclic loading having stress ratios (R) such as − 0.2, − 0.4 and − 0.6 for different temperatures, viz. 100, 300 and 500 K, has been performed using embedded atom method potential. The predicted ratcheting strain by MD simulation for nanocrystalline Ni varies from 15 to 30%. A significant increase in ratcheting strain has been observed with the increase in temperature. It has been observed that the number of vacancies increases, and the number of clusters decreases with the increase in temperature. Slight reduction in crystallinity is identified at the middle of the each loading cycle from the performed cluster analysis. Zigzag pattern of dislocation density has been observed and leads to the decrease in dislocation density with the increase in temperature. Stress ratio does not show any significant effect on the number of vacancies, clusters and dislocation density on structural evolution during the asymmetric cyclic loading. Slight change in the grain rotation has been observed with the increase in temperature, and there is almost no change in the final texture evolved. From the post-tensile tests, ultimate tensile strength that remains same may be due to constant average dislocation density.

36 MATERIALS SCIENCE↗

Crashworthiness of recycled carbon fiber composite sinusoidal structures at dynamic rates

Fiber reinforced polymer composites are finding applications in the automotive space for structurally critical applications including crash management. The use of recycled carbon fiber reinforcement can greatly reduce carbon emissions. In this study, recycled carbon fiber composites were manufactured into a self-supporting geometry using three matrices: polyphenylene sulfide (PPS), acrylonitrile butadiene styrene (ABS), and a structural epoxy, and subsequently crushed between flat platens at dynamic rates ranging from 4.6 to 9.1 ms -1 at temperatures in a range of -40°C to 80°C. Load-displacement data was used to evaluate their specific energy absorption, crush efficiency, and steady-state crush stress. Further, the energy absorption of the ABS composites was strongly sensitive to temperature, while the PPS composites exhibited strong crush efficiency dependence with both rate and temperature. The epoxy composites exhibited stable crush behavior at dynamic crush rates but exhibited a dramatic reduction in crush efficiency relative to quasi-static tests. The results of this study indicate that recycled fiber composites can achieve very high energy absorption levels (50–80kJkg -1 at room temperature) that make them an excellent alternative to more expensive and less environmentally friendly continuous virgin fiber laminates.

42 ENGINEERING↗

Plate motion in sheared granular fault system

Plate motion near the fault gouge layer, and the elastic interplay between the gouge layer and the plate under stick-slip conditions, is key to understanding the dynamics of sheared granular fault systems. Here, a two-dimensional implementation of the combined finite-discrete element method (FDEM), which merges the finite element method (FEM) and the discrete element method (DEM), is used to explicitly simulate a sheared granular gouge fault system. In this work we focus on investigating the influence of normal load, driving shear velocity and plate stiffness on the velocities and displacements in the direction parallel to the shear direction (x-direction) measured at locations on the upper and lower plates just adjacent to the gouge. The simulations show that during slip phases the magnitudes of the measured velocities on the upper and lower plates are proportional to the normal load and may be inversely proportional to the square root of the plate's shear modulus. Whereas, the driving shear velocity does not show distinct influence on the measured velocities. Additionally, large slip velocities are generally associated with large macroscopic friction coefficient drops. For the models subjected to smaller normal loads, larger shear velocities and with stiffer shear plates, the same magnitude of slip velocity could cause a larger drop of macroscopic friction coefficient. During stick phases, the velocities of the upper and lower plates are respectively slightly greater and slightly smaller than half of the driving shear velocity and are both in the same direction of shear. The shear strain rate of the gouge is calculated from this velocity difference between the upper and lower plate during stick phases and thus the gouge effective shear modulus can be calculated. The results show that the gouge effective shear modulus increases proportionally with normal load, while the influence of shear velocity and plate stiffness on gouge effective shear modulus is minor. The simulations address the dynamics of a laboratory-scale fault gouge system and may aid in revealing the complexities of earthquake frictional dynamics.

58 GEOSCIENCES↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Heuristic Dynamic Programming Approach in Boost Converters

In this study, a heuristic dynamic programming controller is proposed to control a boost converter. Conventional controllers such as proportional-integral-derivative (PID) or proportional-integral (PI) are designed based on the linearized small-signal model near the operating point. Therefore, the performance of the controller during the start-up, the load change, or the input voltage variation is not optimal since the system model changes by varying the operating point. The heuristic dynamic programming controller optimally controls the boost converter by following the approximate dynamic programming. The advantage of the HDP is that the neural network-based characteristic of the proposed controller enables boost converters to easily cope with large disturbances. An HDP with a well-trained critic and action networks can perform as an optimal controller for the boost converter. To compare the effectiveness of the traditional PI-based and the HDP boost converter, the simulation results are provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Speed Variation Based Power Regulation Concept for Dynamic Wireless Charging

On-road wireless charging of electric vehicles (EVs) in-motion could potentially reduce range anxiety or battery size with wide-spread deployment. The planning and implementation of such systems are greatly complicated due to their susceptibility to load variation inherent to traffic flow. Here, this paper proposes a method for derisking the potential for traffic slowdowns by compensating for reduced vehicle speed and investigates how implementation may affect system performance. A load modeling case study is presented at 200kW for a mile of high-speed roadway employing speed-based power regulation with results indicating average power usage and maximum car hosting capability can be reduced by 20% and increased by 30% respectively. An 85kHz power electronics model is developed based on designs and prototypes for an 11kW, 190m airgap static system and a 200kW dynamic wireless track. The simulation is validated in the 11kW experimental prototype and modified for 200kW operation to compare with simulated performance. Sensitivity studies are performed in MATLAB/Simulink to evaluate how parameters influence system performance and confirm the capability to reduce output power and maintain efficiency at 11 and 200kW. The static 11kW experimental system operates at 93.6% efficiency and multiple options exist to reduce power while maintaining efficiency greater than 90%. The capability to dynamically modify power output from WPT coils, in an experimentally validated simulation, enables techniques to significantly mitigate load variability due to reductions in vehicle speed.

42 ENGINEERING↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Clustering of Rate-Oriented Load Metrics for Customer Price-Plan Analysis: Preprint

One of the few methods electric utilities can use to motivate and change customer energy consumption is through their retail rate structures. Utilities are increasingly moving towards more dynamic rate-plans to achieve the objectives of motivating energy conservation, increasing self-consumption from onsite renewable generation, reducing peak demand and to flattening the demand profiles. This paper presents a set of rate-oriented customer load metrics that are the determinants of customers bill under four unique rate-plans. These metrics are not only indicative of which rate structure a customer should choose based on their load profiles, but also convey useful information about load consumption behavior. With these metrics, the utility can analyze their customers and identify customer classes that are rewarded under each rate-plan. This can help inform utilities whether the customer profiles being rewarded under each rate-plans are meeting their original objectives. To develop these customer classes, we calculate these rate-oriented load metrics for each customer and perform k-means clustering. The analysis is conducted on from a set of 300 customer profiles, examining the impact of four different rate-plans, different numbers of clusters and looking at customer bills and cluster load profile characteristics.

24 POWER TRANSMISSION AND DISTRIBUTION↗