Ducted Fuel Injection and Cooled Spray Technologies for Particulate Control in Heavy-Duty Diesel Engines

Heavy-Duty diesel engine manufacturers are continuously in pursuit of simple and low-cost technologies that can reduce emissions. Ducted fuel injection (DFI) and Cooled Spray (CS) technologies are two technologies that continue to show promise for significant particulate emissions reductions. These technologies represent a breakthrough in diesel engine combustion from the potential of nearly sootless diesel combustion. This can provide a significant decrease in harmful PM emissions and may enable further system optimization for reduced NOx emissions and increased efficiency. Combustion vessel experiments and engine demonstrations at Sandia, together with the large bore engine tests performed by Wabtec show that this technology may be applicable to heavy duty diesel engines across a wide range of engine sizes and speeds representing the majority of off-road diesel engines. However, very little is known about the ideal geometry, scaling properties or effectiveness of these technologies over the engine operating map. This project will address those uncertainties through a series of experiments performed in an optical and a metal single-cylinder engine.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant (2x2x1 Duct-Fired 758-MWe Facility with F Class Turbines)

A comprehensive front-end engineering design (FEED) study has been undertaken by Bechtel National Inc. (Bechtel) for locating a post-combustion capture and compression (PCC) unit at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in the unredacted FEED Study report (Attachment 1) with all supporting documents, numbering over 150. The Study Report is publicly available. Sizing of the PCC plant is based on treating an amount of flue gas equivalent to that produced when generating 420 MW, which is approximately 68% of the total flue gas emitted by the NGCC power plant operating at guarantee condition with duct burners off. A reduced power plant capacity factor was used for sizing the PCC plant because the gas turbines at the site often operate at reduced load due to the high penetration of renewable power in the ERCOT region. The cost of carbon capture is primarily driven by capital cost (and therefore is highly sensitive to capacity factor). Sizing the capture unit so that when used it is nearly always operating at full capacity is critical to the economic viability of the proposed investment.

03 NATURAL GAS↗

FY2022 Square Duct G-Code

The code included in this document was used to create a square duct additive manufacturing build. Questions regarding the code and documentation can be sent to the authors listed.

36 MATERIALS SCIENCE↗

Ducted Fuel Injection And Cooled Spray Technologies For Particulate Control In Heavy-duty Diesel Engines (Final Report)

Cooled Spray (CS) and Ducted Fuel Injection (DFI) are in-cylinder technologies for diesel engines that can reduce particulate matter and soot emissions and data has been published showing that these technologies can reduce soot emissions by 75-100% for some engines at some operating conditions. However, little is known about scaling the devices for engine size. Additionally, the performance of either technology over the engine duty cycle has not been explored. This project addresses both of these points through single-cylinder engine investigations. The objectives of this project are to provide details about dimensional scaling of these devices and to demonstrate 75% PM reduction over a range of operating conditions on a single-cylinder engine. Two engines were used for this project: a 125mm bore optically accessible engine at Sandia National Laboratories and a 168mm bore metal engine at Southwest Research Institute. The optical engine was used to study the performance of DFI and CS inserts for a large injector orifice diameter injector that is characteristic of a locomotive engine and to perform scaling studies for DFI. The metal engine was used to perform scaling and alignment studies for CS and to evaluate the technology for both EGR and non-EGR engines over the engine operating map. Modifications were required for both engines to accept the prototype inserts being tested. The optical engine required a new fuel injector, cylinder head and piston so that tests could be run at the pressures and engine speeds required. Additionally, a novel rotating stage was designed for the optical engine to simplify alignment of the modules. The metal engine required a modified cylinder head to accept CS inserts and a modified piston to provide additional space around the fuel injector for the CS inserts. Tests on the optical engine showed that DFI reduces PM emissions for both small injector orifices (0.170mm diameter) and large injector orifices (0.290mm). For high load testing, the DFI modules were not as effective as at low load testing, but it was acknowledged that minimal geometric optimization was performed and more improvements may be possible. Comparing DFI to CS and conventional diesel combustion (CDC), DFI performed better than CS or CDC. The CS geometries used in these studies may not be ideal for that engine and additional modifications likely would improve performance. Tests on the metal engine showed PM reductions as high has 80% at some operating conditions with duty-cycle PM reductions of ~50% for EGR and non-EGR configurations. The CS testing on the metal engine showed that chamfering of the fuel passage inlet either through hydro-erosion or mechanical grinding provided significant improvements in the PM reduction capabilities of the insert. Additionally, alignment sensitivities were explored and the data show that the tolerance to misalignment is approximately 0.05 to 0.1mm for the inserts that were studied here. Air-fuel ratio was shown to be important in the effectiveness of the CS inserts. In several tests, it was shown that the CS inserts are more effective at reducing the PM for high-AFR operating conditions compared to low AFR conditions. In summary, multiple designs were evaluated on both engines. It was found that for the conditions and configurations studied here, a fuel passage diameter of ~2.5mm performed best overall. Significant duty-cycle PM reductions are possible using these technologies and sensitivities to AFR, alignment fuel passage diameter and inlet fuel passage shaping were explored and are reported here. More PM reduction may be possible with improved geometric design and attention to alignment practices.

02 PETROLEUM↗

Ducted Fuel Injection and Cooled Spray Technologies for Particulate Control in Heavy-Duty Diesel Engines

Heavy-duty diesel engine manufacturers are continually seeking simple, low-cost technologies to reduce emissions. Ducted Fuel Injection (DFI) and Cooled Spray (CS) technologies have emerged as promising solutions, offering the potential for nearly sootless operation. These innovations could significantly decrease harmful Particulate Matter (PM) emissions while enabling further optimization to reduce Nitrogen Oxides (NOx) and increase efficiency. While initial experiments across various engine types have shown promise, uncertainties remain regarding the ideal geometry, scaling properties, and effectiveness of these technologies across different operating conditions. This project aims to address these knowledge gaps through experiments in both optical and metal single-cylinder engines.

33 ADVANCED PROPULSION SYSTEMS↗

B-ducted Heating of Black Widow Companions

The companions of evaporating binary pulsars (black widows and related systems) show optical emission suggesting strong heating. In a number of cases, large observed temperatures and asymmetries are inconsistent with direct radiative heating for the observed pulsar spindown power and expected distance. Here we describe a heating model in which the pulsar wind sets up an intrabinary shock (IBS) against the companion wind and magnetic field, and a portion of the shock particles duct along this field to the companion magnetic poles. We show that a variety of heating patterns, and improved fits to the observed light curves, can be obtained at expected pulsar distances and luminosities, at the expense of a handful of model parameters. We test this “IBS-B” model against three well-observed binaries and comment on the implications for system masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Ducted Fuel Injection vs. Conventional Diesel Combustion: Extending the Load Range in an Optical Engine with a Four-Orifice Fuel Injector

Ducted fuel injection (DFI) is a technique to attenuate soot formation in compression ignition engines relative to conventional diesel combustion (CDC). The concept is to inject fuel through a small tube inside the combustion chamber to reduce equivalence ratios in the autoignition zone relative to CDC. DFI has been studied at loads as high as 8.5 bar gross indicated mean effective pressure (IMEP g ) and as low as 2.5 bar IMEP g using a four-orifice fuel injector. Across previous studies, DFI has been shown to attenuate soot emissions, increase NO x emissions (at constant charge dilution), and slightly decrease fuel conversion efficiencies for most tested points. This study expands on the previous work by testing 1.1 bar IMEPg (low-load/idle) conditions and 10 bar IMEPg (higher-load) conditions with the same four-orifice fuel injector, as well as examining potential causes of the degradations in NO x emissions and fuel conversion efficiencies. DFI and CDC are directly compared at each operating point in the study. At the low-load condition, the intake charge dilution was swept to elucidate the soot and NO x performance of DFI. The low-load range is important because it is the target of impending, more-stringent emissions regulations, and DFI is shown to be a potentially effective approach for helping to meet these regulations. The results also indicate that DFI likely has slightly decreased fuel conversion efficiencies relative to CDC. We find that the increase in NO x emissions with DFI is likely due to longer charge gas residence times at higher temperatures, which arise from shorter combustion durations and advanced combustion phasing relative to CDC.

42 ENGINEERING↗

Diaphragm eliminates leakage in cryogenic fluid duct coupling

Duct coupling with nickel steel diaphragm of low thermal expansivity is leakproof when used with cryogenic fluids. The diaphragm, located between the two flanges of the coupling, reduces axial shrinkage at the coupling flanges to a minimum.

Source record↗

Bellows joint absorbs torsional deflections in duct system

Long, thin-walled bellows compressed into a short length absorbs the same amount of torsional deflection as the same tube in full length condition and saves in cost, complexity and space. This bellows has lower torsional spring rate to absorb the bulk of the duct assembly tortional deflections, leaving the other bellows free to absorb axial and angular deflections.

Daniels, C. M.↗

Aerodynamic stability and control of ducted- propeller aircraft

Test results from studies of small and large powered models of a dual, tandem, ducted-propeller VTOL design are reviewed, with emphasis on stability and control characteristics through the transition speed range. The character­istics are generally satisfactory. Stability augmentation may be required to reduce Dutch roll tendencies. Further study is needed to evaluate the appar­ently large side-force gradients in sideslip. Reductions in control effective­ness due to ground proximity are similar to those for tilt-wing V /STOL designs.