SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

60 APPLIED LIFE SCIENCES↗

SU-E-I-57: Evaluation and Optimization of Effective-Dose Using Different Beam-Hardening Filters in Clinical Pediatric Shunt CT Protocol

Purpose: Study image optimization and radiation dose reduction in pediatric shunt CT scanning protocol through the use of different beam-hardening filters Methods: A 64-slice CT scanner at OU Childrens Hospital has been used to evaluate CT image contrast-to-noise ratio (CNR) and measure effective-doses based on the concept of CT dose index (CTDIvol) using the pediatric head shunt scanning protocol. The routine axial pediatric head shunt scanning protocol that has been optimized for the intrinsic x-ray tube filter has been used to evaluate CNR by acquiring images using the ACR approved CT-phantom and radiation dose CTphantom, which was used to measure CTDIvol. These results were set as reference points to study and evaluate the effects of adding different filtering materials (i.e. Tungsten, Tantalum, Titanium, Nickel and Copper filters) to the existing filter on image quality and radiation dose. To ensure optimal image quality, the scanner routine air calibration was run for each added filter. The image CNR was evaluated for different kVps and wide range of mAs values using above mentioned beam-hardening filters. These scanning protocols were run under axial as well as under helical techniques. The CTDIvol and the effective-dose were measured and calculated for all scanning protocols and added filtration, including the intrinsic x-ray tube filter. Results: Beam-hardening filter shapes energy spectrum, which reduces the dose by 27%. No noticeable changes in image low contrast detectability Conclusion: Effective-dose is very much dependent on the CTDIVol, which is further very much dependent on beam-hardening filters. Substantial reduction in effective-dose is realized using beam-hardening filters as compare to the intrinsic filter. This phantom study showed that significant radiation dose reduction could be achieved in CT pediatric shunt scanning protocols without compromising in diagnostic value of image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-243: Possibility of Exposure Dose Reduction of Cone-Beam Computed Tomography in An Image Guided Patient Positioning System by Using Various Noise Suppression Filters

Purpose: To investigate the possibility of exposure dose reduction of the cone-beam computed tomography (CBCT) in an image guided patient positioning system by using 6 noise suppression filters. Methods: First, a reference dose (RD) and low-dose (LD)-CBCT (X-ray volume imaging system, Elekta Co.) images were acquired with a reference dose of 86.2 mGy (weighted CT dose index: CTDIw) and various low doses of 1.4 to 43.1 mGy, respectively. Second, an automated rigid registration for three axes was performed for estimating setup errors between a planning CT image and the LD-CBCT images, which were processed by 6 noise suppression filters, i.e., averaging filter (AF), median filter (MF), Gaussian filter (GF), bilateral filter (BF), edge preserving smoothing filter (EPF) and adaptive partial median filter (AMF). Third, residual errors representing the patient positioning accuracy were calculated as an Euclidean distance between the setup error vectors estimated using the LD-CBCT image and RD-CBCT image. Finally, the relationships between the residual error and CTDIw were obtained for 6 noise suppression filters, and then the CTDIw for LD-CBCT images processed by the noise suppression filters were measured at the same residual error, which was obtained with the RD-CBCT. This approach was applied to an anthropomorphic pelvic phantom and two cancer patients. Results: For the phantom, the exposure dose could be reduced from 61% (GF) to 78% (AMF) by applying the noise suppression filters to the CBCT images. The exposure dose in a prostate cancer case could be reduced from 8% (AF) to 61% (AMF), and the exposure dose in a lung cancer case could be reduced from 9% (AF) to 37% (AMF). Conclusion: Using noise suppression filters, particularly an adaptive partial median filter, could be feasible to decrease the additional exposure dose to patients in image guided patient positioning systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-43: Analytical Model for Photon Peripheral Dose in Radiotherapy Treatments

Purpose: The higher survival rate of radiotherapy patients entails a growing concern on second cancers associated to peripheral doses. Currently, dosimetry of out-of field doses is still under development. Our group has developed a methodology to estimate neutron equivalent dose in organs (1,2). We aimed to propose a model to estimate out-of-field photon doses in isocentric treatments from basic clinical data. Methods: The proposed function models the dose as the sum of leakage and scatter terms. The latter is modeled as a virtual source at the collimator, which suffers from attenuation in air and tissue, corrected by the inverse-square-law. The model was parameterized using experimental measurements with TLD700 chips placed inside an anthropomorphic phantom (6–18MV) irradiated with conformal and modulated techniques in Elekta, Siemens and Varian linacs. This model provides photon dose at a point as a function of clinical parameters as prescription dose/UM, PTV volume, distance to the field edge, height of the MLC leaves and distance from the the MLC to the isocenter. Model was tested against independent measurements (TLD100) for a VMAT treatment on a Elekta. Dose to organs is modeled from dose to points along the head-to-feet axis of the organ of a “standard man” escalated by patient height. Results: Our semi-empirical model depends on 3 given parameters (leakage parameter can be individualized). A novelty of our model, over other models (e.g., PERIDOSE), arises from its applicability to any technique (independently of the number of MU needed to deliver a dose). Differences between predictions and measurements were < 0.005mSv/UM. Conclusion: We have proposed a unique model which successfully account for photon peripheral organ dose. This model can be applied in the day-to-day clinic as it only needs a few basic parameters which are readily accessible.1. Radiother. Oncol. 107:234–243, 2013. 2. Phys. Med. Biol. 57:6167–6191, 2012.

60 APPLIED LIFE SCIENCES↗

SU-E-T-162: Evaluation of Dose Calculation of RayStation Planning System in Heterogeneous Media

Purpose: To investigate the clinical reliability of heterogeneity-based dose algorithm using RayStation treatment planning system v.4.0. Methods: The collapsed cone dose calculations in RayStation (RaySearch, Sweden) were compared with the measurements (ion chamber and EBT2 film) and with an in-house Monte Carlo algorithm. A heterogeneous multi-layer phantom and CT images of 4 lung cancer patients were used here. The phantom, composed of multiple solid water slabs and Styrofoams, was irradiated with 6MV beams perpendicular to the layers. The MLC-defined field sizes were 5×5, 10×10, 15×15 and 20×20cm{sup 2}. The chamber was positioned at center of central solid water layer, and the films were placed at interfaces of solid water and Styrofoam. The RayStation dose and Monte Carlo dose were compared by performing absolute gamma analysis (3mm/3%): 1D gamma for PDD in the phantom and 3D gamma for patient volumes receiving dose above 10% of maximum dose. Results: The point dose differences between RayStation and ion chamber measurement were smaller than 1% for all of the field sizes. Between RayStation and film measurement, 5×5cm2 field had the maximum differences : <4mm for the penumbra and <0.3mm for the field width at all Styrofoam-and-solid-water interfaces. The absolute gamma analysis showed good agreement between RayStation and Monte Carlo. For PDD along beam axis in the phantom, the 1D gamma was 95.4, 98.6, 99.6 and 99.3% for field size 5×5, 10×10, 15×15 and 20×202 respectively. For dose comparison using patient CT images, 3D gamma was > 95% for all the patients. Conclusion: With respect to ion chamber/film measurement and Monte Carlo calculation, the collapsed cone algorithm in RayStation computed reasonable dose in both phantom and patient cases. Heterogeneity-based dose calculation of RayStation is clinically acceptable in heterogeneous media.

60 APPLIED LIFE SCIENCES↗

SU-E-T-210: Independent MU Dose Calculation Software for S and S IMRT Using Modified Clarkson Integration Sector

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-444: Quantitatively Comparison of Low Dose Spillage Outside of PTV Edge in Arc Therapy Modalities

Purpose: To quantitatively compare low dose spillage outside of PTV edge in arc therapy modalities Methods: The machines used in the study are Tomotherapy Hi-Arc and Varian 21EX with millennium120 MLC. TPS are TomoPlaning and RayStation for VMAT, respectively. The phantom is a 30cm diameter cylindrical solid water (TOMOTHERAPY, TOMOPHANTOM ASSY). The PTV is 4cm length with ellipsoidal sectional shape with major axis=5cm, minor axis=3cm in the axial plane and reversed in the coronal plane. The PTV volume is created with interpolation. It is located at the center of the phantom. The prescribed dose is 1000x5 cGy to 95% the PTV. The isocenter is set co-centered with the PTV. EBT-3 film was used to measure iso-dose lines at the center plane. Film dosimetry is performed with the RIT, v6.2. Results: the study shows: (1) dose falloff gradient is usually uneven, depending on the PTV shape in the gantry rotation plane. For an elliptical shape, the low dose spillage is wider in the minor axis direction than that in the major axis direction. The more a shape is closer to circular, the more even gradient is all directions; (2)for a circular shape (CAX plane in this study), the maximum dose in % of Rx dose at 2cm from PTV is 55% for Tomo, vs. 70% for VMAT (3) the most rapid dose falloff rang is between 95%–80% IDL for both modalities. Conclusion: Tomo has more rapid dose falloff outside of PTV. In some areas, the gradient is double for Tomo helical than that for LINAC VMAT at same points. Future work will examine the differences between optimization of doses and inherent delivery limitations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-498: Energy Minimization and Dose-Volume Inverse Optimization in Prostate Cancer

Purpose: To compare dose-volume (DVH) and energy minimization-based (EM) optimization for prostate cancer cases. Methods: A dozen of prostate plans were retrospectively studied. For each case two IMRT plans were generated, one with DVH and the other with EM objective cost function. Those different objective functions were used only for the organs at risk (OARs), while target objectives were achieved through DVH cost functions. The plans used the same beam angles, maximum number of segments per plan, minimum segment area and MUs per segment. Both plans were normalized such that 95% of the PTV was covered by the same prescription dose. After prescription was achieved, doses to the OARs were iteratively lowered until the standard deviation of the dose across the PTV was ~3.5%. Plan quality was evaluated by several dose indices (DIs). A DI represents the dose delivered to certain volume of a structure. Tallied DIs were for rectum and bladder 10%, 40%, 60% volumes, and 1% volumes of the femoral heads as surrogate for maximum doses. Statistical significance in the differences among DIs was quantified with two-tailed paired t-tests. Results: On average EM plans performed better than DVH plans. Statistically significant dose reduction in rectum DI10, DI40, and DI60, were 2.6%, 25.7%, and 35.9%, respectively. For bladder DI10, DI40, and DI60 the differences were 1.1%, 20.8%, and 29.7%. Left and right femoral head DI1s were better by 33.8% and 27.8% in EM plans. The quoted dose reduction is with respect to EM absolute doses for the DIs. Conclusion: The performance of EM optimization with respect to DVH optimization is patient and DI dependent. While in some cases specific DIs were better with DVH optimization, on average the energy minimization allows better (ranging from 1% to ~40%) OAR sparing than DVH optimization. NIH-NCI.

60 APPLIED LIFE SCIENCES↗

SU-E-T-628: Effect of Dose Rate and Leakage Correction for Dosimetric Leaf Gap Measurement

Purpose: To study the dose rate response of Mapcheck and quantify/correct dose rate/leakage effect on IMRT QA. Evaluate the dose rate/leakage effect on dosimetric leaf gap (DLG) measurement. Methods: Varian Truebeam Linac with HD120 MLC was used for all measurement, it is capable to adjust dose rate from 600MU/min to 5MU/min. Fluke Advanced Therapy Doisemter and PTW 30013 Farmer chamber for chamber measurement; SunNuclear Mapcheck2 with 5cm total buildup for diode measurement. DLG was measured with both chamber and diode.Diode response was measured by varies dose rate, while fixed mapcheck setup and total MU. MLC Leakage was measured with both chamber and diode. Mapcheck measurement was saved as movie file (mcm file), which include measurement updated every 50mSec. The difference between intervals can be converted to dose and dose rate and leakage response correction can be applied to them. Results: DLG measurement results with chamber and diode were showed as follows, the DLG value is 0.36 vs. 0.24mm respectively. Diode dose rate response drops from 100% at 600MU/min to 95.5% at 5MU/min as follows. MLC Leakage measured with diode is 1.021%, which is 9% smaller than 1.112% from chamber measurement. By apply the dose rate and leakage correction, the residue error reduced 2/3. Conclusions: Diode has lower response at lower dose rate, as low as 4.5% for 5MU/min; diode has lower energy response for low energy too, 5% lower for Co-60 than 6MV. It partially explains the leakage difference of 9% between chamber and diode. Lower DLG with diode is because of the lower response at narrower gap, in Eclipse however DLG need to increase to makeup lower response, which is over correction for chamber though. Correction can reduce error by 2/3, the rest 1/3 can be corrected by scatter effect, which is under study.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-645: Dose Enhancement to Cell Nucleus Due to Hard Collisions of Protons with Electrons in Gold Nanospheres

Purpose: The purpose of this study was to investigate the theoretical dose enhancement to a cell nucleus due to increased fluence of secondary electrons when gold nanospheres are present in the cytoplasm during proton therapy. Methods: We modeled the irradiation of prostate cancer cells using protons of variable energies when 10,000 gold nanoparticles, each with radius of 10 nm, were randomly distributed in the cytoplasm. Using simple analytical equations, we calculated the increased mean dose to the cell nucleus due to secondary electrons produced by hard collisions of 0.1, 1, 10, and 100 MeV protons with orbital electrons in gold. We only counted electrons with kinetic energy higher than 1 keV. In addition to calculating the increase in the mean dose to the cell nucleus, we also calculated the increase in local dose in the “shadow,” i.e., the umbra, of individual gold nanospheres due to forward scattered electrons. Results: For proton energies of 0.1, 1, 10, and 100 MeV, we calculated increases to the mean nuclear dose of 0.15, 0.09, 0.05, and 0.04%, respectively. When we considered local dose increases in the shadows of individual gold spheres, we calculated local dose increases of 5.5, 3.2, 1.9, and 1.3%, respectively. Conclusion: We found negligible, less than 0.2%, increases in the mean dose to the cell nucleus due to electrons produced by hard collisions of protons with electrons in gold nanospheres. However, we observed increases up to 5.5% in the local dose in the shadow of gold nanospheres. Considering the shadow radius of 10 nm, these local dose enhancements may have implications for slightly increased probability of clustered DNA damage when gold nanoparticles are close to the nuclear membrane.

60 APPLIED LIFE SCIENCES↗

MO-G-18A-01: Radiation Dose Reducing Strategies in CT, Fluoroscopy and Radiography

Advances in medical x-ray imaging have provided significant benefits to patient care. According to NCRP 160, there are more than 400 million x-ray procedures performed annually in the United States alone that contributes to nearly half of all the radiation exposure to the US population. Similar growth trends in medical x-ray imaging are observed worldwide. Apparent increase in number of medical x-ray imaging procedures, new protocols and the associated radiation dose and risk has drawn considerable attention. This has led to a number of technological innovations such as tube current modulation, iterative reconstruction algorithms, dose alerts, dose displays, flat panel digital detectors, high efficient digital detectors, storage phosphor radiography, variable filters, etc. that are enabling users to acquire medical x-ray images at a much lower radiation dose. Along with these, there are number of radiation dose optimization strategies that users can adapt to effectively lower radiation dose in medical x-ray procedures. The main objectives of this SAM course are to provide information and how to implement the various radiation dose optimization strategies in CT, Fluoroscopy and Radiography. Learning Objectives: To update impact of technological advances on dose optimization in medical imaging. To identify radiation optimization strategies in computed tomography. To describe strategies for configuring fluoroscopic equipment that yields optimal images at reasonable radiation dose. To assess ways to configure digital radiography systems and recommend ways to improve image quality at optimal dose.

60 APPLIED LIFE SCIENCES↗

WE-A-18A-01: TG246 On Patient Dose From Diagnostic Radiation

Radiation dose from diagnostic and interventional radiations continues to be a focus of the regulatory, accreditation and standards organizations in the US and Europe. A Joint AAPM/EFOMP effort has been underway in the past year — having the goal to assist the clinical medical physicist with communicating optional and varied approaches in estimating (and validating) patient dose. In particular, the tools provided by DICOM Radiation Dose Structured Reports, either by themselves or as part of a networked data repository of dose related information are a rich source of actionable information. The tools of the medical physicist have evolved to include using DICOM data in meaningful ways to look at patient dose with respect to imaging practices. In addition to how accurate or reproducible a dose value is (totally necessary and our traditional workspace) it is now being asked how reproducible (patient to patient, device to device) are the delivered doses (new tasking)? Clinical medical physicists are best equipped to assist our radiology and technologist colleagues with this effort. The purpose of this session is to review the efforts of TG246 - bringing forward a summary content of the TG246 Report including specific dose descriptors for CT and Fluoroscopy — particularly in a focus of leveraging the RDSR as a means for monitoring good practices ALARA. Additionally, rapidly evolving technologies for more refined dose estimates are now in use. These will be presented as they look to having highly patient specific dose estimates in automated use.

60 APPLIED LIFE SCIENCES↗

TH-A-9A-01: Active Optical Flow Model: Predicting Voxel-Level Dose Prediction in Spine SBRT

Purpose: To predict voxel-level dose distribution and enable effective evaluation of cord dose sparing in spine SBRT. Methods: We present an active optical flow model (AOFM) to statistically describe cord dose variations and train a predictive model to represent correlations between AOFM and PTV contours. Thirty clinically accepted spine SBRT plans are evenly divided into training and testing datasets. The development of predictive model consists of 1) collecting a sequence of dose maps including PTV and OAR (spinal cord) as well as a set of associated PTV contours adjacent to OAR from the training dataset, 2) classifying data into five groups based on PTV's locations relative to OAR, two “Top”s, “Left”, “Right”, and “Bottom”, 3) randomly selecting a dose map as the reference in each group and applying rigid registration and optical flow deformation to match all other maps to the reference, 4) building AOFM by importing optical flow vectors and dose values into the principal component analysis (PCA), 5) applying another PCA to features of PTV and OAR contours to generate an active shape model (ASM), and 6) computing a linear regression model of correlations between AOFM and ASM.When predicting dose distribution of a new case in the testing dataset, the PTV is first assigned to a group based on its contour characteristics. Contour features are then transformed into ASM's principal coordinates of the selected group. Finally, voxel-level dose distribution is determined by mapping from the ASM space to the AOFM space using the predictive model. Results: The DVHs predicted by the AOFM-based model and those in clinical plans are comparable in training and testing datasets. At 2% volume the dose difference between predicted and clinical plans is 4.2±4.4% and 3.3±3.5% in the training and testing datasets, respectively. Conclusion: The AOFM is effective in predicting voxel-level dose distribution for spine SBRT. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-BRD-07: Minimizing Dose Uncertainty for Spot Scanning Beam Proton Therapy of Moving Tumor with Optimization of Delivery Sequence

Purpose: Intensity modulated proton therapy (IMPT) has been shown to be able to reduce dose to normal tissue compared to intensity modulated photon radio-therapy (IMRT), and has been implemented for selected lung cancer patients. However, respiratory motion-induced dose uncertainty remain one of the major concerns for the radiotherapy of lung cancer, and the utility of IMPT for lung patients was limited because of the proton dose uncertainty induced by motion. Strategies such as repainting and tumor tracking have been proposed and studied but repainting could result in unacceptable long delivery time and tracking is not yet clinically available. We propose a novel delivery strategy for spot scanning proton beam therapy. Method: The effective number of delivery (END) for each spot position in a treatment plan was calculated based on the parameters of the delivery system, including time required for each spot, spot size and energy. The dose uncertainty was then calculated with an analytical formula. The spot delivery sequence was optimized to maximize END and minimize the dose uncertainty. 2D Measurements with a detector array on a 1D moving platform were performed to validate the calculated results. Results: 143 2D measurements on a moving platform were performed for different delivery sequences of a single layer uniform pattern. The measured dose uncertainty is a strong function of the delivery sequence, the worst delivery sequence results in dose error up to 70% while the optimized delivery sequence results in dose error of <5%. END vs. measured dose uncertainty follows the analytical formula. Conclusion: With optimized delivery sequence, it is feasible to minimize the dose uncertainty due to motion in spot scanning proton therapy.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-11: Adaptive-Beamlet Based Finite Size Pencil Beam (AB-FSPB) Dose Calculation Algorithm for Independent Verification of IMRT and VMAT

Purpose: In current IMRT and VMAT settings, the use of sophisticated dose calculation procedure is inevitable in order to account complex treatment field created by MLCs. As a consequence, independent volumetric dose verification procedure is time consuming which affect the efficiency of clinical workflow. In this study, the authors present an efficient Pencil Beam based dose calculation algorithm that minimizes the computational procedure while preserving the accuracy. Methods: The computational time of Finite Size Pencil Beam (FSPB) algorithm is proportional to the number of infinitesimal identical beamlets that constitute the arbitrary field shape. In AB-FSPB, the dose distribution from each beamlet is mathematically modelled such that the sizes of beamlets to represent arbitrary field shape are no longer needed to be infinitesimal nor identical. In consequence, it is possible to represent arbitrary field shape with combinations of different sized and minimal number of beamlets. Results: On comparing FSPB with AB-FSPB, the complexity of the algorithm has been reduced significantly. For 25 by 25 cm2 squared shaped field, 1 beamlet of 25 by 25 cm2 was sufficient to calculate dose in AB-FSPB, whereas in conventional FSPB, minimum 2500 beamlets of 0.5 by 0.5 cm2 size were needed to calculate dose that was comparable to the Result computed from Treatment Planning System (TPS). The algorithm was also found to be GPU compatible to maximize its computational speed. On calculating 3D dose of IMRT (∼30 control points) and VMAT plan (∼90 control points) with grid size 2.0 mm (200 by 200 by 200), the dose could be computed within 3∼5 and 10∼15 seconds. Conclusion: Authors have developed an efficient Pencil Beam type dose calculation algorithm called AB-FSPB. The fast computation nature along with GPU compatibility has shown performance better than conventional FSPB. This completely enables the implantation of AB-FSPB in the clinical environment for independent volumetric dose verification.

60 APPLIED LIFE SCIENCES↗

Sci—Thur AM: YIS - 06: An EPID-based 3D patient dose verification method for SBRT-VMAT delivery

Purpose: Stereotactic body radiation therapy (SBRT) delivered via volumetric modulated arc therapy (VMAT) can strongly benefit from an in vivo patient dose verification due to the large doses per fraction. Electronic portal imaging devices (EPIDs) can be utilized as a patient dose dosimeter. In this work we present a physics-based model which utilizes on-treatment EPID images to reconstruct the dose delivered to an anthropomorphic phantom during SBRT-VMAT delivery. Methods: An SBRT linac beam was modeled using Monte Carlo methods and verified with measured data. Our dose reconstruction model back-projects EPID measured focal fluence upstream of the patient and adds a predicted extra-focal fluence component. This fluence is forward projected onto the patient's density matrix and convolved with dose kernels to calculate dose. The model was validated for two prostate, three lung, and two spine SBRT-VMAT treatments. Results were compared to the treatment planning system's calculation. Results: 2%/2 mm chi comparison calculations gave pass rates for the whole volume, infield, and high dose region respectively, and no lower than: 98%, 95%, 99% for the prostate plans, 99%, 92%, 85% for the lung plans, and 91%, 85%, 81% for the spine plans. A 3%/3mm calculation gave pass rates no lower than 99%, 94%, and 90% for all dose regions for the prostate, lung, and spine respectively. Conclusions: We have developed a physics-based model which calculates delivered dose to phantom (or patient) for SBRT-VMAT delivery using on treatment EPID images. The accuracy of the results has allowed us to test this model clinically.

60 APPLIED LIFE SCIENCES↗

Sci—Fri PM: Topics — 04: What if bystander effects influence cell kill within a target volume? Potential consequences of dose heterogeneity on TCP and EUD on intermediate risk prostate patients

In vitro evidence has suggested that radiation induced bystander effects may enhance non-local cell killing which may influence radiotherapy treatment planning paradigms. This work applies a bystander effect model, which has been derived from published in vitro data, to calculate equivalent uniform dose (EUD) and tumour control probability (TCP) and compare them with predictions from standard linear quadratic (LQ) models that assume a response due only to local absorbed dose. Comparisons between the models were made under increasing dose heterogeneity scenarios. Dose throughout the CTV was modeled with normal distributions, where the degree of heterogeneity was then dictated by changing the standard deviation (SD). The broad assumptions applied in the bystander effect model are intended to place an upper limit on the extent of the results in a clinical context. The bystander model suggests a moderate degree of dose heterogeneity yields as good or better outcome compared to a uniform dose in terms of EUD and TCP. Intermediate risk prostate prescriptions of 78 Gy over 39 fractions had maximum EUD and TCP values at SD of around 5Gy. The plots only dropped below the uniform dose values for SD ∼ 10 Gy, almost 13% of the prescribed dose. The bystander model demonstrates the potential to deviate from the common local LQ model predictions as dose heterogeneity through a prostate CTV is varies. The results suggest the potential for allowing some degree of dose heterogeneity within a CTV, although further investigations of the assumptions of the bystander model are warranted.

60 APPLIED LIFE SCIENCES↗

Sci—Fri PM: Dosimetry—04: Radiation out-of-field dose in the treatment of pediatric central nervous system malignancies

Children diagnosed with central nervous system (CNS) malignancies often receive radiotherapy, which can cause radiogenic late effects. In order to identify and reduce the risk of these late effects, we must understand the radiation doses that these children receive. Modern treatment planning systems accurately estimate the absorbed dose within the treatment fields but poorly estimate the dose outside them. The purpose of our study was to measure the out-of-field dose for children receiving localized radiotherapy for CNS cancer and apply an analytical model for estimating dose as a function of distance from the field edge. Radiation fields designed for a 12-year-old boy treated in our clinic were applied to an anthropomorphic phantom containing more than 200 thermoluminescent dosimeters. A double-Gaussian function of absorbed dose versus distance from the field edge (i.e., 50% isodose line) was applied, and parameters were allowed to vary and were fit to the model by minimizing the root mean square deviation, RMSD. The fitted model accurately predicted the dose from distances of 4 cm to 50 cm (RMSD = 0.54 cGy/Gy), but the model was not useful in estimating dose for distances less than 4 cm because of wide variation in measured dose, and the double-Gaussian model failed by systematically underestimating the dose beyond 50 cm. In conclusion, the double-Gaussian model may be applicable for points at distances from the field edge between 4 cm and 50 cm, where most children's radiosensitive tissues are located, but for points beyond 50 cm, an improvement should be investigated.

60 APPLIED LIFE SCIENCES↗