Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

HZETRN: neutron and proton production in quasi-elastic scattering of GCR heavy-ions

The development of transport models for radiation shielding design and evaluation has provided a series of deterministic computer codes that describe galactic cosmic radiation (GCR), solar particle events, and experimental beams at particle accelerators. These codes continue to be modified to accommodate new theory and improvements to the particle interaction database (Cucinotta et al., 1994, NASA Technical Paper 3472, US Government Printing Office, Washington DC). The solution employed by the heavy-ion transport code HZETRN was derived with the assumption that nuclear fragments are emitted with the same velocity as the incident ion through velocity conserving nuclear interactions. This paper presents a version of the HZETRN transport code that provides a more realistic distribution of the energy of protons and neutrons emitted from GCR interactions in shields. This study shows that the expected GCR dose equivalent is lower than previously calculated for water shields that are less than 110 g cm-2 thick. Calculations of neutron energy spectra in low Earth orbit indicate substantial contributions from relativistic neutrons. c2001 Elsevier Science Ltd. All rights reseved.

NASA Center LaRC↗

Proportional counter as neutron detector

A technique to separate out the dose, and lineal energy spectra of neutrons and charged particles is described. It is based on using two proportional counters, one with a wall, and the other with similar characteristics but wall made from a non-hydrogen containing material. Results of a calibration in a neutron field are also shown. c2001 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

Neutron dosimetry in low-earth orbit using passive detectors

This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttle's cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the ~6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission. c2001 Elsevier Science Ltd. All rights reserved.

Flight Experiment↗

Neutron measurements onboard the space shuttle

The radiation environment inside a shielded volume is highly complex, consisting of both charged and neutral particles. Since the inception of human space flights, the charged particle component has received virtually all of the attention. There is however, a significant production of secondary neutrons, particularly from the aluminum structure in low earth orbiting spacecrafts. The interactions of galactic cosmic rays (GCR), and solar energetic particles with the earth's atmosphere produce a non-isotropic distribution of albedo neutrons. Inside any reasonable habitable module, the average radiation quality factor of neutrons is about 4-5 times larger than the corresponding average quality factor of charged particles. The measurement of neutrons and their energy spectra is a difficult problem due the intense sources of charged particles. This paper reviews the results of Shuttle flight experiments (made during both solar maximum and solar minimum) to measure the contribution of neutrons to the dose equivalent, as well as theoretical calculations to estimate the appropriate range of neutron energies that contribute most to the dose equivalent. Published by Elsevier Science Ltd.

short duration↗

Enhanced animal growth via ligand-regulated GHRH myogenic-injectable vectors

Regulated animal growth occurred following a single electroporated injection of a mixture of two plasmids (10 microg of DNA), one expressing the GeneSwitch regulator protein, the other an inducible growth hormone releasing hormone (GHRH) gene, into the tibialis anterior muscles of adult SCID mice. Administration of the ligand mifepristone (MFP) up-regulated GHRH expression, as shown by elevations of IGF-I levels, and when MFP dosing was withdrawn, IGF-I returned to baseline levels. Five cycles of IGF-I induction were observed during a five-month period. Chronic MFP dosing for 25 days increased lean body mass, weight gain, and bone mineral density significantly compared with non-MFP treated controls. In summary, long-term drug-regulated GHRH expression was achieved following plasmid-based gene therapy, and chronic induction of GHRH expression in adult animals led to improvements in weight gain and body composition.

NASA Discipline Musculoskeletal↗

Monte Carlo predictions of DNA fragment-size distributions for large sizes after HZE particle irradiation

DSBs (double-strand breaks) produced by densely ionizing space radiation are not located randomly in the genome: recent data indicate DSB clustering along chromosomes. DSB clustering at large scales, from >100 Mbp down to approximately 2 kbp, is modeled using a Monte-Carlo algorithm. A random-walk model of chromatin is combined with a track model, that predicts the radial distribution of energy from an ion, and the RLC (randomly-located-clusters) formalism, in software called DNAbreak. This model generalizes the random-breakage model, whose broken-stick fragment-size distribution is applicable to low-LET radiation. DSB induction due to track interaction with the DNA volume depends on the radiation quality parameter Q. This dose-independent parameter depends only weakly on LET. Multi-track, high-dose effects depend on the cluster intensity parameter lambda, proportional to fluence as defined by the RLC formalism. After lambda is determined by a numerical experiment, the model reduces to one adjustable parameter Q. The best numerical fits to the experimental data, determining Q, are obtained. The knowledge of lambda and Q allows us to give biophysically based extrapolations of high-dose DNA fragment-size data to low doses or to high LETs.

NASA Center JSC↗

Once we know all the radiobiology we need to know, how can we use it to predict space radiation risks and achieve fame and fortune?

It has been over 40 years since occupational radiation exposures to NASA's astronauts began and more than 300 individuals have been exposed to low and intermediate doses of trapped protons and galactic cosmic rays (GCR). The International Space Station (ISS) will add substantially to this number and significantly increase average lifetime doses. We review these exposures in this report. After many years of investigation, the method used to assess risk have not changed significantly. However, molecular biology and genetics have made enormous progress in establishing the mechanisms of cancer formation, damage to the central nervous system, and individual variation in sensitivity to radiation. We discuss critical questions and possible new approaches to the prediction of risk from space radiation exposures. Experimental models can lead to testable theories that along with extensive biophysical and informatics approaches, will lead to fame and fortune by allowing for accurate projections of astronaut risks and for the development of biological countermeasures.

NASA Center JSC↗

Monte Carlo track structure for radiation biology and space applications

Over the past two decades event by event Monte Carlo track structure codes have increasingly been used for biophysical modelling and radiotherapy. Advent of these codes has helped to shed light on many aspects of microdosimetry and mechanism of damage by ionising radiation in the cell. These codes have continuously been modified to include new improved cross sections and computational techniques. This paper provides a summary of input data for ionizations, excitations and elastic scattering cross sections for event by event Monte Carlo track structure simulations for electrons and ions in the form of parametric equations, which makes it easy to reproduce the data. Stopping power and radial distribution of dose are presented for ions and compared with experimental data. A model is described for simulation of full slowing down of proton tracks in water in the range 1 keV to 1 MeV. Modelling and calculations are presented for the response of a TEPC proportional counter irradiated with 5 MeV alpha-particles. Distributions are presented for the wall and wall-less counters. Data shows contribution of indirect effects to the lineal energy distribution for the wall counters responses even at such a low ion energy.

NASA Center JSC↗

Visual assessment of the radiation distribution in the ISS Lab module: visualization in the human body

The US Lab module of the International Space Station (ISS) is a primary working area where the crewmembers are expected to spend majority of their time. Because of the directionality of radiation fields caused by the Earth shadow, trapped radiation pitch angle distribution, and inherent variations in the ISS shielding, a model is needed to account for these local variations in the radiation distribution. We present the calculated radiation dose (rem/yr) values for over 3,000 different points in the working area of the Lab module and estimated radiation dose values for over 25,000 different points in the human body for a given ambient radiation environment. These estimated radiation dose values are presented in a three dimensional animated interactive visualization format. Such interactive animated visualization of the radiation distribution can be generated in near real-time to track changes in the radiation environment during the orbit precession of the ISS.

NASA Center JSC↗

Quality factors for alpha particles emitted in tissue

A concept of a mean or dose averaged quality factor was defined in ICRP Publication 26 using relationships for quality factor as a function of LET. The concept of radiation weighting factors, wR, was introduced in ICRP Publication 60 in 1990. These are meant to be generalized factors that modify absorbed dose to reflect the risk of stochastic effects as a function of the quality of the radiation incident on the body or emitted by radioactivity within the body. The values of wr are equal to 20 for all alpha particles externally or internally emitted. This note compares the dose averaged quality factor for alpha particles originating in tissue using the old and revised recommendations for quality factor as a function of LET. The dose averaged quality factor never exceeds 20 using the old recommendations and is never less than 20 with the revised recommendations.

Non-NASA Center↗

Space radiation absorbed dose distribution in a human phantom

The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

STS-91 Shuttle Project↗

Shuttle radiation dose measurements in the International Space Station orbits

The International Space Station (ISS) is now a reality with the start of a permanent human presence on board. Radiation presents a serious risk to the health and safety of the astronauts, and there is a clear requirement for estimating their exposures prior to and after flights. Predictions of the dose rate at times other than solar minimum or solar maximum have not been possible, because there has been no method to calculate the trapped-particle spectrum at intermediate times. Over the last few years, a tissue-equivalent proportional counter (TEPC) has been flown at a fixed mid-deck location on board the Space Shuttle in 51.65 degrees inclination flights. These flights have provided data that cover the expected changes in the dose rates due to changes in altitude and changes in solar activity from the solar minimum to the solar maximum of the current 23rd solar cycle. Based on these data, a simple function of the solar deceleration potential has been derived that can be used to predict the galactic cosmic radiation (GCR) dose rates to within +/-10%. For altitudes to be covered by the ISS, the dose rate due to the trapped particles is found to be a power-law function, rho(-2/3), of the atmospheric density, rho. This relationship can be used to predict trapped dose rates inside these spacecraft to +/-10% throughout the solar cycle. Thus, given the shielding distribution for a location inside the Space Shuttle or inside an ISS module, this approach can be used to predict the combined GCR + trapped dose rate to better than +/-15% for quiet solar conditions.

NASA Discipline Radiation Health↗

Radiation transport modeling and assessment to better predict radiation exposure, dose, and toxicological effects to human organs on long duration space flights

NASA is very interested in improving its ability to monitor and forecast the radiation levels that pose a health risk to space-walking astronauts as they construct the International Space Station and astronauts that will participate in long-term and deep-space missions. Human exploratory missions to the moon and Mars within the next quarter century, will expose crews to transient radiation from solar particle events which include high-energy galactic cosmic rays and high-energy protons. Because the radiation levels in space are high and solar activity is presently unpredictable, adequate shielding is needed to minimize the deleterious health effects of exposure to radiation. Today, numerous models have been developed and used to predict radiation exposure. Such a model is the Space Environment Information Systems (SPENVIS) modeling program, developed by the Belgian Institute for Space Aeronautics. SPENVIS, which has been assessed to be an excellent tool in characterizing the radiation environment for microelectronics and investigating orbital debris, is being evaluated for its usefulness with determining the dose and dose-equivalent for human exposure. Thus far. the calculations for dose-depth relations under varying shielding conditions have been in agreement with calculations done using HZETRN and PDOSE, which are well-known and widely used models for characterizing the environments for human exploratory missions. There is disagreement when assessing the impact of secondary radiation particles since SPENVIS does a crude estimation of the secondary radiation particles when calculating LET versus Flux. SPENVIS was used to model dose-depth relations for the blood-forming organs. Radiation sickness and cancer are life-threatening consequences resulting from radiation exposure. In space. exposure to radiation generally includes all of the critical organs. Biological and toxicological impacts have been included for discussion along with alternative risk mitigation methods--shielding and anti-carcinogens. c 2001. Elsevier Science Ltd. All rights reserved.

STS-91 Shuttle Project↗

Extrapolation of the dna fragment-size distribution after high-dose irradiation to predict effects at low doses

The patterns of DSBs induced in the genome are different for sparsely and densely ionizing radiations: In the former case, the patterns are well described by a random-breakage model; in the latter, a more sophisticated tool is needed. We used a Monte Carlo algorithm with a random-walk geometry of chromatin, and a track structure defined by the radial distribution of energy deposition from an incident ion, to fit the PFGE data for fragment-size distribution after high-dose irradiation. These fits determined the unknown parameters of the model, enabling the extrapolation of data for high-dose irradiation to the low doses that are relevant for NASA space radiation research. The randomly-located-clusters formalism was used to speed the simulations. It was shown that only one adjustable parameter, Q, the track efficiency parameter, was necessary to predict DNA fragment sizes for wide ranges of doses. This parameter was determined for a variety of radiations and LETs and was used to predict the DSB patterns at the HPRT locus of the human X chromosome after low-dose irradiation. It was found that high-LET radiation would be more likely than low-LET radiation to induce additional DSBs within the HPRT gene if this gene already contained one DSB.

NASA Discipline Radiation Health↗

TLD efficiency of 7LiF for doses deposited by high-LET particles

The efficiency of 7 LiF TLDs (TLD-700) in registering dose from high-LET (> or = 10 keV/micrometers) charged particles (relative to 137Cs gamma rays) has been measured for a number of accelerated heavy ions at various particle accelerator facilities. These measured efficiency values have been compared with similar results obtained from the open literature and a dose efficiency function has been fitted to the combined data set. While it was found that the dose efficiency is not only a function of LET, but also of the charge of the incident particle, the fitted function can be used to correct the undermeasured value of dose from exposures made in mixed radiation fields where LET information is available. This LET-dependent dose efficiency function is used in our laboratory in determining total absorbed dose and dose equivalent from combined TLD and CR-39 plastic nuclear track detector measurements.

NASA Discipline Radiation Health↗

Strontium transfer from maternal skeleton to the fetus estimated on the basis of the Techa river data

Measurements of 90Sr in human bone of inhabitants of the Techa river region were started in 1951, and since 1974 the Techa river population has been studied with a whole-body counter. One of the dosimetric tasks that could be decided using data on 90Sr measurements is direct evaluation of strontium transfer to the fetus from the maternal skeleton. Six cases were selected for which 90Sr measurements were available both for stillborn infants and their mothers. The ratio of 90Sr concentrations in fetal bone to maternal bone for the year of pregnancy has been evaluated. Two clusters of values were found and the difference between clusters could be explained by age-dependent features of maternal bone formation and remodelling. When the mother's 90Sr intake occurred in the period of intensive compact bone growth, the transfer coefficient was very low (0.012-0.032). If 90Sr ingestion occurred during the woman's reproductive age, the transfer to fetus was equal to 0.21-0.26.

Non-NASA Center↗

Retrospective dosimetry related to chronic environmental exposure

Radioactive contamination of the environment occurred in the early fifties as a result of the releases from the Mayak plutonium production complex (Southern Urals, Russia). The releases of liquid wastes into the Techa river resulted in chronic exposure of 30,000 residents of the riverside communities. Since 1951 90Sr body burdens have been measured for over half of this cohort. This paper presents the analysis of data on 90Sr in humans and describes the reconstruction of internal doses for these people.

NASA Discipline Radiation Health↗

An analysis of energy deposition in a tissue equivalent proportional counter onboard the space shuttle

An improved prediction for space radiations in the lower earth orbits measured by the shuttle TEPC is obtained when energy loss straggling and chord length distribution of the detector are considered. A generalized analytic model is used to describe the energy deposition of direct ion interaction events in a micron-size detector. The transport calculation accounting for the shuttle configuration is accomplished by using a new version of HZETRN that has been extensively verified with laboratory and flight data. The agreement of predicted and measured lineal energy spectra is within 70% for the region above 2 keV/micrometer but within a factor of 2.3 underpredicted for the region below this value. The inclusion of indirect delta ray events in the model is needed before possible causes for the underprediction below 2 keV/micrometer can be assessed.

Flight Experiment↗