Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Ex-situ Heat Treatment of TEM Foils in a Custom Titanium Fixture: A Case Study on Ni-based Superalloy

The advancement of microstructural characterization at the nanoscale is critical to understanding the microstructural evolution and performance of engineering materials. Transmission electron microscopy (TEM) plays a vital role in such investigations, particularly when coupled with controlled ex- and in-situ experiments. In this study, we introduce a novel method for ex-situ heat treatment (HT) of TEM foils using a custom-designed fixture, made from pure titanium, and vacuum furnace to inhibit oxidation. This approach ensures precise temperature control and minimal sample contamination during HT, critical for substructural characterization and analysis of metallic materials. The fixture consists of a titanium base with three slits, for three sample foils, and a titanium cap for closure. The entire assembly is placed in a vacuum heat treatment furnace with high vacuum capability to prevent oxidation. To validate the effectiveness of the setup, precipitation behavior and microstructural changes were studied in an IN725 variant heat-treated at 500°C for 1 hour and 282 variant heat-treated at 700°C for 1 hour, as case studies.

electron microscopy↗

Investigation Of Prandtl-Ishlinskii Hysteresis Compensation for Deep Space Optical Communications Pointing Control

This paper studies the simulated performance of the Deep Space Optical Communication (DSOC) laser downlink pointing control system that has a pointing requirement at the sub-microradian scale. To achieve the required pointing precision, the DSOC Flight Laser Transceiver (FLT) point-ahead mirror (PAM) employs piezoelectric actuators, which are widely used in precision applications due to their high motion resolution, rapid response, and high output forces. However, a piezoelectric actuator's performance is often limited by nonlinearities in their response, most significantly hysteresis. To study the effect of hysteresis on our simulated pointing performance, an invertible hysteresis model is developed using the Classical Prantdl-Ishlinskii (CPI) method. The simulation includes models of DSOC hardware and electronic system components based on key parameters (bias, frequency response, noise), with the hysteresis modeled in the PAM piezo actuator dynamics. A Proportional-Integral controller provides feedback with measurements from two potential sources: strain gauge sensors or a photon-counting camera. To compensate for hysteresis behavior, a feedforward inverse CPI hysteresis model is implemented in the control system. Two CPI models are built using different sampling methods (uniform sampling and cosine spacing) and controller performance is compared. For the maximum command range of ±400 μrad at 1 mHz, results show that the feedforward combined with feedback control reduces output tracking error by 50% or 58% (to 0.20 or 0.38 μrad) compared to feedback control alone (from 0.40 or 0.90 μrad), corresponding to the uniform-sampled and cosine-sampled CPI models, respectively.

Marinello, Lindsey A.↗

Hybrid state-space self-tuning control of uncertain linear systems

The paper presents a hybrid state-space self-tuner using a new dual-rate sampling scheme for digital adaptive control of continuous-time uncertain linear systems. A state-space-based recursive least-squares algorithm, together with a variable forgetting factor, is used for direct estimations of both the equivalent discrete-time uncertain linear system parameters and the associated discrete-time state of a continuous-time uncertain linear system from the sampled input and output data. An analogue optimal regional pole-placement design method is used for designing an optimal observer-based analogue controller. A suboptimal observer-based digital controller is then designed from the designed analogue controller using digital redesign technique. To enhance the robustness of parameter identification and state estimation algorithms, a dynamic bound for a class of uncertain bilinear parameters and a fast-rate digital controller are developed at each fast-sampling period. Also, to accommodate computation loads and computation delay for developing the advanced hybrid self-tuner, the designed analogue controller and observer gains are both updated at each slow-sampling period. This control technique has been successfully applied to benchmark control problems.

Shieh, L. S.↗

Taste Perception of Branched Maltooligosaccharides

Oral processing of starch generates linear and branched maltooligosaccharides (MOS). This study investigates the impact of branching and the degree of polymerization (DP) on MOS taste detection. Three branched MOS samples (A−C) were enzymatically prepared from gelatinized waxy corn starch and characterized using reducing-end assays, MALDI-TOF MS, β-amylase hydrolysis, and GC-MS linkage analysis. Samples A, B, and C had average DPs of 6, 10, and 18, respectively, with α-1,6 branch points comprising 9−13% of glycosidic bonds; linear MOS were negligible. In triangle tests, participants evaluated MOS samples and a maltose control at 75 mM, with and without lactisole, a sweet receptor inhibitor. All samples were detectable without lactisole (d′ = 1.81−2.9; p < 0.05), but not with lactisole (d′ = 0−0.61; p > 0.05). These findings demonstrate that α-1,6 branching enables MOS detection via the sweet receptor, not the putative “starchy” receptor, underscoring the importance of glycosidic structure in carbohydrate taste perception.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Factors affecting the sticking of insects on modified aircraft wings

Past studies have shown that the surface energy of a polymer coating has an important effect on the sticking of insects to the surface. However, mechanical properties of polymer coatings such as elasticity may also be important. A further study is suggested using polymer coatings of known surface energy and modulus so that a better understanding of the mechanism of the sticking of insects to surfaces can be achieved. As the first step for the study, surface analysis and road tests were performed using elastomers having different energies and different moduli. The number of insects sticking to each elastomer was counted and compared from sample to sample and with a control (aluminum). An average height moment was also calculated and comparisons made between samples.

Yi, O.↗

The study of dopant segregation behavior during the growth of GaAs in microgravity

An investigation into the segregation behavior of selenium doped gallium arsenide during directional solidification in the microgravity environment was conducted using the Crystal Growth Furnace (CGF) aboard the first United States Microgravity Laboratory (USML-1). The two crystals grown were 1.5 cm in diameter and 16.5 cm in length with an initial melt length of 14 cm. Two translation periods were executed, the first at 2.5 microns/s and after a specified time, which was different between the two experiments, the translation rate was doubled to 5.0 microns/s. The translation was then stopped and the remaining sample melt was solidified using a gradient freeze technique in the first sample and a rapid solidification in the second experiment. Measurement of the selenium dopant distribution, using quantitative infrared transmission imaging, indicates that the first sample initially achieved diffusion controlled growth as desired. However, after about 1 cm of growth, the segregation behavior was driven from a diffusion controlled growth regime to a complete mixing regime. Measurements in the second flight sample indicated that the growth was always in a complete mixing regime. In both experiments, voids in the center line of the crystal, indicative of bubble entrapment, were found to correlate with the position in the crystal when the translation rates were doubled.

Matthiesen, David H.↗

Multirate digital control system design

Methods for multirate digital control system design are discussed. A simple method for sampling rate selection based on control bandwidths is proposed. Methods for generating a discrete-time state model of a sampled-data plant and a discrete-time equivalent to an analog cost function for a sampled-data plant are described. The succesive loop closures and linear quadratic Gaussian synthesis methods are reviewed, and a constrained optimization synthesis method is introduced. The proposed sampling rate selection, discretization, and synthesis methods are applied to two example design problems. Multirate and single-rate compensators synthesized by the different methods are compared, based on closed-loop responses, with compensators having the same real-time computation load.

Berg, Martin C.↗

Tailoring the rheological properties of high protein suspension by thermal-mechanical treatment

The viscoelasticity of concentrated protein suspensions associates closely with the mixing efficiency and cleaning frequency of facility during high-protein food development. This study investigated the effects of thermal-mechanical treatment on the viscoelasticity of milk protein isolate (MPI) suspensions and their underlying mechanisms to develop protein ingredient with low viscoelasticity. MPI suspensions (20%) were treated at 25, 50 and 85°C for 10-60 min under constant shear (100 s -1 ), followed by storage at 4°C. The viscosity (η) of MPI suspension treated at 50°C and 85°C was similar to 1-10% as those treated at 25 ° C. After four days of storage at 4°C, η showed the least value in 50°C-treated samples compared to those at 25 ° C and 85 ° C. The η and storage modulus (G') was decreased with prolonged treatment at 25 and 50°C, whereas opposite trend was found in 85°C treated samples. Differential scanning calorimetry found proteins in 50°C treated samples had smaller enthalpy than those in the control and 25°C treated samples. Protein surface hydrophobicity was increased slightly from 25°C to 50°C, but remarkably in 85°C treated samples. Ultra-small angle x-ray scattering showed the radius of gyration (R-g) of casein micelle was similar to 38 nm at 25°C and 50°C treated samples but increased to similar to 44 nm 85°C treated samples with reduced compactness. A new sphere-like structure with R-g of 18 nm was generated in 85°C treated samples. These findings suggested modulating temperature during thermal-mechanical treatment is essential to alter protein structures and morphology for desirable rheological properties.

59 BASIC BIOLOGICAL SCIENCES↗

An application of high authority/low authority control and positivity

Control Dynamics Company (CDy), in conjunction with NASA Marshall Space Flight Center (MSFC), has supported the U.S. Air Force Wright Aeronautical Laboratory (AFWAL) in conducting an investigation of the implementation of several DOD controls techniques. These techniques are to provide vibration suppression and precise attitude control for flexible space structures. AFWAL issued a contract to Control Dynamics to perform this work under the Active Control Technique Evaluation for Spacecraft (ACES) Program. The High Authority Control/Low Authority Control (HAC/LAC) and Positivity controls techniques, which were cultivated under the DARPA Active Control of Space Structures (ACOSS) Program, were applied to a structural model of the NASA/MSFC Ground Test Facility ACES configuration. The control systems design were accomplished and linear post-analyses of the closed-loop systems are provided. The control system designs take into account effects of sampling and delay in the control computer. Nonlinear simulation runs were used to verify the control system designs and implementations in the facility control computers. Finally, test results are given to verify operations of the control systems in the test facility.

Seltzer, S. M.↗

Silicon Dioxide Deposited Using Atmospheric Pressure Plasma Chemical Vapor Deposition for Improved Adhesion and Water Intrusion Resistance for Lightweight Manufacturing

This work aims to demonstrate the barrier coating, and adhesion promoting properties of silica-based coatings deposited using an atmospheric pressure plasma torch (APPT). This is achieved by applying an industrial grade adhesive to silica thin films deposited, on the surfaces to be joined, using atmospheric pressure plasma chemical vapor deposition (APP-CVD), to make single joint lap shear samples of different metal combinations commonly found in lightweight manufacturing such as aluminum and magnesium as well as steel. To deposit these thin films, two separate silicon based organic precursors, hexamethyldisiloxane (HMDSO), and tetraehylorthosilicate (TEOS), are used. Here, samples are bonded using DuPont Betamate 1486 adhesive, and the lap shear results for these films are compared to the lap shear results of a chemically cleaned control using the same adhesive. The APPT uses a microwave power supply and gas mixtures of N 2 and Ar. The adhesion of the films are tested using lap shear, and elevated temperature water soaks are conducted on the joints as well to simulate environmental exposure. Lap shear results from samples with silica thin films max shear stress are 25%-115% increase compared to control samples depending on material. After exposure to water soak the max shear strength of the joints decreased by less than 15%, which demonstrates the films capabilities as a water barrier. Film morphology is examined using Scanning Electron Microscopy (SEM), and the film’s composition and approximate thickness are obtained using Rutherford Backscattering Spectroscopy (RBS).

36 MATERIALS SCIENCE↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Association between simian virus 40 and non-Hodgkin lymphoma

BACKGROUND: Non-Hodgkin lymphoma has increased in frequency over the past 30 years, and is a common cancer in HIV-1-infected patients. Although no definite risk factors have emerged, a viral cause has been postulated. Polyomaviruses are known to infect human beings and to induce tumours in laboratory animals. We aimed to identify which one of the three polyomaviruses able to infect human beings (simian virus 40 [SV40], JC virus, and BK virus) was associated with non-Hodgkin lymphoma. METHODS: We analysed systemic non-Hodgkin lymphoma from 76 HIV-1-infected and 78 HIV-1-uninfected patients, and non-malignant lymphoid samples from 79 HIV-1-positive and 107 HIV-1-negative patients without tumours; 54 colon and breast carcinoma samples served as cancer controls. We used PCR followed by Southern blot hybridisation and DNA sequence analysis to detect DNAs of polyomaviruses and herpesviruses. FINDINGS: Polyomavirus T antigen sequences, all of which were SV40-specific, were detected in 64 (42%) of 154 non-Hodgkin lymphomas, none of 186 non-malignant lymphoid samples, and none of 54 control cancers. This difference was similar for HIV-1-infected patients and HIV-1-uninfected patients alike. Few tumours were positive for both SV40 and Epstein-Barr virus. Human herpesvirus type 8 was not detected. SV40 sequences were found most frequently in diffuse large B-cell and follicular-type lymphomas. INTERPRETATION: SV40 is significantly associated with some types of non-Hodgkin lymphoma. These results add lymphomas to the types of human cancers associated with SV40.

Non-NASA Center↗

Plasma current collection of Z-93 thermal control paint as measured in the Lewis Research Center's plasma interaction facility

A sample of Z-93 thermal control paint was exposed to a simulated space environment in a plasma chamber. The sample was biased through a series of voltages ranging from -100 volts to +300 volts and electron and ion currents were measured. Currents were found to be in the micro-ampere range indicating that the material remains a reasonably good insulator under plasma conditions. As a second step, the sample was left in the chamber for six days and retested. Collected currents were reduced by from two to five times from the previous values indicating a substantial loss of conductivity. As a final test, the sample was removed, exposed to room conditions for two days, and returned to the chamber. Current measurements showed that the sample had partially recovered the lost conductivity. In addition to presenting these results, this report documents all of the experimental data as well as the statistical analyses performed.

Hillard, G. Barry↗

3rd harmonic magnetometry assessment of NbTiN-based SIS structures

In the quest for alternative superconducting materials to bring accelerator cavity performance beyond the bulk niobium (Nb) intrinsic limits, a promising concept proposes that superconductor-insulator-superconductor (SIS) thin film structures can delay magnetic flux penetration in accelerator cavities to higher fields [1]. NbTiN is a candidate superconductor for such structures. We have demonstrated high quality NbTiN and AlN deposited by reactive direct current magnetron sputtering (DCMS), both for individual layers and multilayers. Interface quality has been assessed for bi-layer stacks with various NbTiN and AlN thicknesses from 500 and 30 nm down to 3 and 1 nm. These SIS structures show continued sharp interfaces. The Hfp enhancement of the films was examined with 3rd harmonic magnetometry. The system was designed and built in an ongoing collaboration with CEA Saclay. It can measure 1? to 2? samples on a temperature controlled stage. This contribution presents the assessment of the first penetration field enhancement with 3rd harmonic magnetometry for standalone films and multilayer nanostructures.

Valente, Anne-Marie↗

Perspective: Biochemical and Physical Constraints Associated With Preparing Thin Specimens for Single-Particle Cryo-EM

While many aspects of single-particle electron cryo-microscopy (cryo-EM) of biological macromolecules have reached a sophisticated level of development, this is not yet the case when it comes to preparing thin samples on specimen grids. As a result, there currently is considerable interest in achieving better control of both the sample thickness and the amount of area that is useful, but this is only one aspect in which improvement is needed. This Perspective addresses the further need to prevent the macromolecular particles from making contact with the air-water interface, something that can result in preferential orientation and even structural disruption of macromolecular particles. This unwanted contact can occur either as the result of free diffusion of particles during the interval between application, thinning and vitrification of the remaining buffer, or—when particles have been immobilized—by the film of buffer becoming too thin prior to vitrification. An opportunity now exists to apply theoretical and practical insights from the fields of thin-film physical chemistry and interfacial science, in an effort to bring cryo-EM sample preparation to a level of sophistication that is comparable to that of current data collection and analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Exposure of Polymer Film Thermal Control Materials on the Materials International Space Station Experiment (MISSE)

Seventy-nine samples of polymer film thermal control (PFTC) materials have been provided by the National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) for exposure to the low Earth orbit environment on the exterior of the International Space Station (ISS) as part of the Materials International Space Station Experiment (MISSE). MISSE is a materials flight experiment sponsored by the Air Force Research Lab/Materials Lab and NASA. This paper will describe background, objectives, and configurations for the GRC PFTC samples for MISSE. These samples include polyimides, fluorinated polyimides, and Teflon fluorinated ethylene propylene (FEP) with and without second-surface metallizing layers and/or surface coatings. Also included are polyphenylene benzobisoxazole (PBO) and a polyarylene ether benzimidazole (TOR-LM). On August 16, 2001, astronauts installed passive experiment carriers (PECs) on the exterior of the ISS in which were located twenty-eight of the GRC PFTC samples for 1-year space exposure. MISSE PECs for 3-year exposure, which will contain fifty-one GRC PFTC samples, will be installed on the ISS at a later date. Once returned from the ISS, MISSE GRC PFTC samples will be examined for changes in optical and mechanical properties and atomic oxygen (AO) erosion. Additional sapphire witness samples located on the AO exposed trays will be examined for deposition of contaminants.

Dever, Joyce↗

ISS External Microorganisms: A Planetary Protection Experiment to Inform Requirements for Crewed Missions to Mars

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗