Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Simulation-Based Design and Optimization of Waste Heat Recovery Systems

This fact sheet features an R&D project that will develop a modeling platform that can quantify the value of a district energy system and its potential for waste heat recovery. The new software analysis platform will evaluate and optimize district energy systems to better utilize low-temperature waste heat from nearby commercial and industrial buildings. The platform will help project developers and engineers easily quantify the potential value and cost savings of community energy systems for both producers and consumers of waste heat.

Combined heat and power, CHP, District energy, Was↗

From fault-detection to automated fault correction: A field study

A fault detection and diagnostics (FDD) tool, as addressed by this study, is a tool that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Although FDD tools can inform operators of building operational faults, currently an action is always required to correct the faults to generate energy savings. Fault auto-correction integrating with commercial FDD technology offerings can close the loop between the passive diagnostics and active control, increase the savings generated by FDD tools, and reduce the reliance on human intervention. This paper presents the field study of seven fault auto-correction algorithms implemented in commercial FDD platforms. Implementation includes software changes in the FDD tools and additional controls hardware or software changes in the BAS that were required to enable the execution of different types of auto-correction algorithms in real buildings. The routines successfully and automatically correct faults and improve the operation of large built-up Heating, Ventilation, and Air Conditioning (HVAC) systems, common in most commercial buildings. The auto-correction algorithms are tested across four buildings and three different building automation systems, following a rigorous procedure to make sure they work properly and do not negatively impact the system and building occupants. Finally, technology benefits, market drivers, and scalability changes are drawn from the implementation effort and test results, to drive future research and industry engagement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Gateway Program as Part of NASA’s Plans for Human Exploration Beyond Low Earth Orbit

This paper provides an overview and status of Gateway, humanity’s first space station in lunar orbit as a vital component of the NASA-led Artemis missions to return humans to the Moon as preparation for the first human missions to Mars. Gateway is an aggregation point in deep space for a variety of spacecraft, including the crewed Orion vehicle, the Human Landing System that will ferry astronauts to and from the lunar surface, logistics supply craft, and vehicles transiting further into deep space beyond the Earth-Moon system, such as to Mars. NASA is building on decades of partnership with space agencies on three continents and multiple commercial partners to design, build, and launch Gateway’s core elements to near-rectilinear halo orbit (NRHO) around the Moon, where it will operate for a minimum of 15 years. Gateway is humanity’s next in-space science utilization platform, and its first in deep space, with three science payloads already selected to study solar and cosmic radiation. This paper will provide an overview of the Gateway space station’s major components in various stages of development, including the Power and Propulsion Element (PPE), Habitation and Logistics Outpost (HALO), the International Habitation (I-Hab) module, ESPRIT Refueling Module (ERM), the planned airlock, advanced external robotics systems, Deep Space Logistics supply craft, and next-generation autonomous Vehicle System Manager software. It will also provide an overview of how Gateway will be utilized for science, and highlight the space station’s multilateral governance structure and international agreements.

Emma Lehnhardt↗

Commercial PACE Financing for New Construction

This fact sheet provides an overview for building owners and developers to take advantage of commercial property assessed clean energy (CPACE) financing for new construction, adaptive reuse, or renovation projects.

Commercial PACE, CPACE, Microgrid, Renewables, new↗

Catalyst for Expanding Human Spaceflight

History supplies us with many models of how and how not to commercialize an industry. This presentation draws parallels between industries with government roots, like the railroad, air transport, communications and the internet, and NASAs Commercial Crew Program. In these examples, government served as a catalyst for what became a booming industry. The building block approach the Commercial Crew Program is taking is very simple -- establish a need, laying the groundwork, enabling industry and legal framework.

Industry catalyst↗

Commercial and Residential Hourly Load Profiles for All Typical Meteorological Year 3 (TMY3) Locations in the United States

One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High-quality end-use load profiles (EULPs) provide this information and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy funded a 3-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute-resolution load profiles for all major residential and commercial building types and end uses across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utility Managed Distributed Energy Resources Intelligent Community - UDERMS iCommunity (Final Technical Report)

The Utility Managed Distributed Energy Resources Intelligent Community (UDERMS iCommunity) project, led by PacifiCorp and supported by the U.S. Department of Energy’s Building Technologies Office (Award No. DEEE0009782), aimed to demonstrate an integrated, utility-managed “behind-the-meter” distributed energy resource (DER) program connecting multifamily, commercial, institutional, and industrial buildings to deliver grid services and improve energy efficiency.

14 SOLAR ENERGY↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solutions

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

Building America↗

A review of select human-building interfaces and their relationship to human behavior, energy use and occupant comfort

In recent years, research has emerged to quantitatively and qualitatively understand occupants' interactions with buildings. However, there has been surprisingly little research on building interfaces and how their design, context (e.g., location), and underlying logic impact their usability and occupants’ perceived control, as well as the resulting comfort and energy performance. This means that research is needed to better understand how occupants interact with building interfaces in both commercial and residential applications; both applications are important to address as there are many differences in interface types, level of control and understanding, and even expectations of engagement. Herein, this paper provides a cursory review and discussion of select common building interfaces: windows, window shades/blinds, thermostats, and lighting controls. The goal of this paper is to review literature related to these human-building interfaces to explore interface characteristics, current design and use challenges, and relationships between building interfaces and occupants. Human-building interface interactions are complex, more research is needed to understand design, use, and characteristics. Common themes emerged throughout the literature review to explain occupant interactions (or lack of interactions) with building interfaces, which included thermal and visual comfort, ease and access of control, interface/control placement, poor interface/control design, lack of understanding, and social-behavioral dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MODELING AND TESTING OF A NOVEL ULTRA-LOW TEMPERATURE SCO2 OPPOSING PISTON EXPANDER

The Flameless Pressurized Oxy-Combustion (FPO) cycle, a novel flexible fuel technology, is being developed into a large pilot. This effort seeks to complete the preliminary engineering and planning of a 25 MWth Pilot Plant that will demonstrate the technology for scale-up to a commercial unit. The technology, pioneered by ITEA at the 5 MWth scale, must be brought to a higher technology readiness level (TRL) to be viable at the commercial scale. The 25 MWth pilot cycle was optimized for cost and technology development and demonstration. Preliminary drawings, layouts, and plans were defined. Process flow diagrams were used to describe the pilot configuration in greater detail. A heat and mass balance with stream data was created. A master equipment list specified the operating conditions for major pieces of equipment within the pilot using this heat and mass balance. The 25 MWth FPO pilot is assessed for environmental performance. A test campaign is developed to assess the type of test and number of hours required for pilot demonstration. The environmental performance is compared against projected performance at the commercial scale. This project builds upon extensive evaluation of the techno-economic performance of the FPO technology already performed by ITEA. This includes system improvements, such as the addition of a turbo-expander to the flue gas stream. Some of the performance-enhancing components are not as well defined as others. The primary goal of this effort was to bring all of the core cycle components to the same level of design maturity. A techno-economic assessment (TEA) evaluated the FPO technology at the commercial scale in comparison to the NETL baseline cases. The reference plants were used in combination with proprietary equipment estimates to build a plant capital cost and cost of electricity evaluation. FPO performed better than the sub-bituminous post-combustion capture cases. Further preliminary estimates of improvements to the FPO cycle show even further gains when compared to conventional carbon capture methods.

01 COAL, LIGNITE, AND PEAT↗

DEVELOPMENT OF A 25 MWTH FLAMELESS PRESSURIZED OXY-COMBUSTION PILOT

The Flameless Pressurized Oxy-Combustion (FPO) cycle, a novel flexible fuel technology, is being developed into a large pilot. This effort seeks to complete the preliminary engineering and planning of a 25 MWth Pilot Plant that will demonstrate the technology for scale-up to a commercial unit. The technology, pioneered by ITEA at the 5 MWth scale, must be brought to a higher technology readiness level (TRL) to be viable at the commercial scale. The 25 MWth pilot cycle was optimized for cost and technology development and demonstration. Preliminary drawings, layouts, and plans were defined. Process flow diagrams were used to describe the pilot configuration in greater detail. A heat and mass balance with stream data was created. A master equipment list specified the operating conditions for major pieces of equipment within the pilot using this heat and mass balance. The 25 MWth FPO pilot is assessed for environmental performance. A test campaign is developed to assess the type of test and number of hours required for pilot demonstration. The environmental performance is compared against projected performance at the commercial scale. This project builds upon extensive evaluation of the techno-economic performance of the FPO technology already performed by ITEA. This includes system improvements, such as the addition of a turbo-expander to the flue gas stream. Some of the performance-enhancing components are not as well defined as others. The primary goal of this effort was to bring all of the core cycle components to the same level of design maturity. A techno-economic assessment (TEA) evaluated the FPO technology at the commercial scale in comparison to the NETL baseline cases. The reference plants were used in combination with proprietary equipment estimates to build a plant capital cost and cost of electricity evaluation. FPO performed better than the sub-bituminous post-combustion capture cases. Further preliminary estimates of improvements to the FPO cycle show even further gains when compared to conventional carbon capture methods.

20 FOSSIL-FUELED POWER PLANTS↗

Transit Habitat Concept and Mars Analog in Cislunar Orbit

- Transit Habitat Overview - Supports 4-crew during Lunar-Mars Analog missions leading up to a 700-1110-day Mars mission - Hybrid inflatable-metallic habitat structure - Launched commercially and outfitted with logistics in cis-lunar orbit (NRHO) - Docks w/ an interim propulsion bus or Gateway for first ~5 years until Mars Propulsion System (MPS) elements available - Extends Gateway operations beyond 60 days - Contingency Airlock and EVA capability - Planned reuse for multiple missions over 15-year lifetime - Builds on ISS and commercial investment in deep space habitation - Mid-2030s launch with late 2030s Mars Departure

Mars↗

Safe, Low-Cost, High Energy-Density, Solid-State Li-Ion Batteries

We developed intrinsically safe, robust, low-cost, high-energy-density solid-state Li-ion batteries, by integrating high conductivity garnet-type solid Li ion electrolytes and several different cathodes in tailored microstructures, fabricated by low-cost supported thin-film ceramic techniques, to overcome the primary technological barriers to next generation battery technology. In this ARPA-E project we employed Li-garnet solid-state electrolytes pioneered by one of the co-investigators (Thangadurai) which has room temperature (RT) conductivity of ~10 -3 S cm -1 . The highly stable garnet SSE allowed the use of S, NMC, and other cathodes with Li metal anodes without stability or flammability concerns. We studied the garnet’s stability when exposed to CO 2 and humidity (with or without an ALD coating) and showed that the material can be processed in ambient air for most steps prior to battery assembly, significantly reducing production costs. We extensively studied and scaled up the synthesis of the powder and explored external suppliers of garnet to determine the best pathway for commercial success. We used low-cost and scalable tapecasting fabrication methods to create porous-dense-porous “trilayer” solid electrolyte microstructures with a ~20 μm separating dense layer, and >70% porosity porous layers to host the electrodes. These scalable multilayer ceramic fabrication techniques, without need for dry rooms or vacuum equipment, also provide for dramatically reduced manufacturing costs. The tailored microstructured electrode supports (scaffold) increased interfacial area ~50x, overcoming the high impedance typical of planar geometry SSLiBs, resulting in record-setting 10 mA/cm 2 lithium cycling in a symmetric cell. We expanded our tapecasting ability and showed tapes >25m in length by the end of the project. We demonstrated the ability to sinter garnet without the use of a garnet powderbed, which could have been a major obstacle and waste of material at scale. At the same time, we expanded the size of our trilayers from coin cells (0.7 cm 2 ) to the full format design (30 cm 2 ). To develop full cells, we demonstrated 250 Wh/kg at room temperature with commercial NMC electrode films in a bilayer configuration. Similarly, we demonstrated 280 Wh/kg trilayer Li-S cells at room temperature with >90% capacity retention over 300 cycles. At 90°C we demonstrated 350 Wh/kg with a Li-S trilayer. The high thermal stability of the garnet electrolyte also enabled extended cycling (400 cycles) of a Li-TiS 2 cell at 150 °C, showcasing the exceptional safety and nonflammability of the solid-state trilayer batteries. Ion Storage Systems has taken this technology and knowledge to produce trilayer garnet electrolytes and is building out facilities to commercialize high performance solid state batteries. ISS has hired a strong staff, identified and communicated with a large number of potential partners, and successfully secured follow-on funding.

25 ENERGY STORAGE↗