Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Centrality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

The Virasoro minimal string

We introduce a critical string theory in two dimensions and demonstrate that this theory, viewed as two-dimensional quantum gravity on the worldsheet, is equivalent to a double-scaled matrix integral. The worldsheet theory consists of Liouville CFT with central charge c ≥ ≥ 25 coupled to timelike Liouville CFT with central charge 26-c. The double-scaled matrix integral has as its leading density of states the universal Cardy density of primaries in a two-dimensional CFT, thus motivating the name Virasoro minimal string. The duality holds for any value of the continuous parameter c c and reduces to the JT gravity/matrix integral duality in the large central charge limit. It thus provides a precise stringy realization of JT gravity. The main observables of the Virasoro minimal string are quantum analogues of the Weil-Petersson volumes, which are computed as absolutely convergent integrals of worldsheet CFT correlators over the moduli space of Riemann surfaces. By exploiting a relation of the Virasoro minimal string to three-dimensional gravity and intersection theory on the moduli space of Riemann surfaces, we are able to give a direct derivation of the duality. We provide many checks, such as explicit numerical - and in special cases, analytic - integration of string diagrams, the identification of the CFT boundary conditions with asymptotic boundaries of the two-dimensional spacetime, and the matching between the leading non-perturbative corrections of the worldsheet theory and the matrix integral. As a byproduct, we discover natural conformal boundary conditions for timelike Liouville CFT.

Physics↗

Cross section measurements of deuteron electro-disintegration at very high recoil momenta and large 4-momentum transfers (Q^2)

The 2H(e,e'p)n cross sections have been measured at negative 4-momentum transfers of Q^2 = 4.5 +/- 0.5 (GeV/c)^2 and Q^2 = 3.5 +/- 0.5 (GeV/c)^2 reaching neutron recoil (missing) momenta up to p_r ?1.0 GeV/c. The data have been obtained at fixed neutron recoil angles 5 <= theta_nq <= 95 degrees with respect to the 3-momentum transfer q. The new data agree well with the previous data which reached p_r ?550 MeV/c. At theta_nq = 35 and 45 degrees, final state interactions (FSI), meson exchange currents (MEC) and isobar configurations (IC) are suppressed and the plane wave impulse approximation (PWIA) provides the dominant cross section contribution. The new data are compared to recent theoretical calculations, and a significant disagreement for recoil momenta p_r > 700 MeV/c is observed. The experiment was carried out in experimental Hall C at the Thomas Jefferson National Accelerator Facility (TJNAF) and formed part of a group of four experiments that were used to commission the new Super High Momentum Spectrometer (SHMS). The experiment consisted of a 10.6 GeV electron beam incident on a liquid deuterium target which resulted in the break-up of the deuteron into a proton and neutron. The scattered electrons were detected by the SHMS in coincidence with the knocked-out protons detected in the previously existing High Momentum Spectrometer (HMS) and the recoiling neutrons were reconstructed from energy-momentum conservation laws. To ensure that the 2H(e,e'p)n reaction channel was selected, we required the missing energy of the system to be the binding energy of the deuteron (?2.22 MeV). The spectrometers? central angles and momenta were set to measure three central missing momentum settings of the neutron corresponding to p_r = 80, 580 and 750 MeV/c, which required the SHMS central angle and momentum to be fixed and the HMS to be rotated from smaller to larger angles corresponding to the lower and higher missing momentum settings, respectively. The experiment was carried out in a time period of six days with typical electron beam currents of 45-60 uA at about 50% beam efficiency.

Yero, Carlos↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Base Case

In order to meet the requirements of U.S. Department of Energy (DOE) in DOE O 435.1 Chg. 1, Radioactive Waste Management, a composite analysis (CA) must be completed for the Central Plateau at the Hanford Site. The updated Hanford Site CA requires estimates of fate and transport of radionuclides in the groundwater from multiple sources within and downgradient of the Central Plateau. Numerical simulations using the MT3D-MST computer code were conducted to evaluate the fate and transport of existing distributions of 16 radionuclides as identified in CP-62184, Hanford Site Composite Analysis: Radionuclide Selection for Groundwater Pathway Evaluation: tritium (H-3), carbon-14 (C-14), chloride- 36 (Cl-36), strontium-90 (Sr-90), technetium-99 (Tc-99), rhenium-187 (Re-187), radium-226 (Ra-226), thorium-230 (Th-230), uranium-232 (U-232), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), neptunium-237 (Np-237), and uranium-238 (U- 238). This document details the application of the P2R Model version 8.3 to predict the fate and transport of contaminants in groundwater on the Central Plateau for the 10,052 year simulation to support the CA. The simulation of fate and transport of contaminants reported in this environmental calculation file (ECF) will support dose predictions as part of the updated Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distribution of Infiltration in the 216-U-10, 216-B-3 Pond, and 216-T-4 Pond Systems 1944-1997

A modeling system to simulate fate and transport of contaminant plumes in groundwater beneath the Central Plateau to support the Cumulative Impact Evaluation (CIE) and Composite Analysis (CA) is being developed. The CIE will evaluate the cumulative effect of multiple Central Plateau radiological and chemical sources on groundwater quality. This will enable cleanup decisions to be evaluated in the context of all Central Plateau waste sites and existing groundwater conditions. The purpose of this Environmental Calculation File (ECF) is to partition the infiltration of wastewater and contaminant inventory between the main pond and each expansion lobe of the 216-B-3 Pond system, and to partition the infiltration of wastewater and contaminant inventory between the ditches and ponds of the 216-U-10 Pond and 216-T-4 Pond systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Boundary Layer Climatology at ARM Southern Great Plains

Operational since 1992, the Atmospheric Radiation Measurement (ARM) southern great plains (SGP) site at Oklahoma, USA has become a reference research site for meteorological studies. Due to an open data policy the ARM data are used by researchers all over the world. In this report, we review the long-term climatology of the atmospheric boundary layer, SGP instrumentations, the site and some site-specific atmospheric conditions which potentially effect wind turbines within the region. As the atmospheric boundary layer is bounded and influenced by the surface, observations of surface radiation components and heat fluxes are crucial in understanding land-atmosphere interactions. The entrainment of air, updrafts, downdrafts and boundary layer height characteristics is needed for understanding the structure and growth of the atmospheric boundary layer. Therefore, measurements from both surface in-situ and remote sensing observations at SGP provide an overall climatology and their interactions from surface up to the boundary layer. Measurements from a 60 m meteorological tower, surface flux stations, disdrometers, soil temperature and moisture flux plates, coherent Doppler lidar, Raman lidar, radiosondes, and satellite data at SGP central facility were analyzed. All the measurements were generally within a few square kilometers of each other at the central facility. This report focuses on data from January 2010 to June 2020 at SGP central facility. The various sections describe the ARM SGP site and surrounding wind turbines; in-situ and remote sensing instrumentation used in the report; provides mathematical equations to analyze fluxes, turbulence and other boundary layer parameters; a climatological analysis of surface winds, fluxes and thermodynamic parameters for several years; an analysis of observed winds in the framework of Monin-Obukhov Similarity Theory; an analysis of the boundary layer winds and direction from a Doppler lidar; multi-year turbulence estimates through the boundary layer from a Doppler lidar; atmospheric boundary layer water vapor and relative humidity profiles from Raman lidar; cloud base height and boundary layer height from multiple sensors and satellite data; and finally site specific atmospheric conditions, such as nocturnal low-level jets. Diurnal, seasonal and yearly variations of surface, sub-surface and boundary layer quantities, such as wind speed, direction, temperature, atmospheric stability, soil temperature, and various atmospheric fluxes at SGP showed distinct trends useful for focused modeling studies. The applicability of surface similarity theory on ARM SGP data is also evaluated, which showed northerly flows are aligned with MO theory estimates compared to southerly flows. Boundary layer winds and direction profiles for several years from a Doppler lidar shows a consistent presence of a nocturnal low-level jet and predominant southerly wind directions through the boundary layer at SGP. The inter-annual variability at SGP is low (<3.5%), with a mean annual wind speed of approximately 7 m s -1 at 100 m above ground level. Boundary layer turbulence and moisture transport from Doppler and Raman lidars are evaluated, which provides evidence of increased water vapor mass flux into the great plains during nocturnal low-level jets. The moisture flux from nocturnal low-level jets is observed to be maximum during summer periods. A novel machine learning algorithm is implemented to accurately estimate the planetary boundary layer height, providing further insights into growth and destruction of the convective boundary layer height during various seasons and land-atmosphere conditions. The high frequency of low-level clouds during winter, spring and fall seasons is validated using the multi-sensor array and satellite estimates of cloud top height. Satellite vegetative fraction data provides insight into seasonal surface roughness and vegetation variability around SGP site.

54 ENVIRONMENTAL SCIENCES↗

Boundary Layer Climatology at ARM Southern Great Plains

Operational since 1992, the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site in Oklahoma, USA, has become a reference research site for meteorological studies. Because of an open data policy the ARM data are used by researchers all over the world. In this report, we review the long-term climatology of the atmospheric boundary layer, the SGP instrumentation, the site and some site-specific atmospheric conditions, which potentially affect wind turbines in the region. Because the atmospheric boundary layer is bounded and influenced by the land surface, observations of surface radiation components and heat fluxes are crucial to understanding land–atmosphere interactions. The entrainment of air, updrafts, downdrafts, and boundary layer height characteristics is needed for understanding the structure and growth of the atmospheric boundary layer. Therefore, measurements from both ground surface in situ and remote-sensing observations at the SGP site provide an overall climatology and their interactions from ground surface up to the boundary layer. Measurements from a 60 m meteorological tower, surface flux stations, disdrometers, soil temperature and moisture flux plates, coherent Doppler lidar, Raman lidar, radiosondes, and satellite data at the SGP central facility were analyzed. All the measurements were generally made within a few square kilometers of each other at the central facility. This report focuses on data from January 2010 to June 2020 at the SGP central facility. The various sections describe the ARM SGP site and surrounding wind turbines; in situ and remotesensing instrumentation used in the report; mathematical equations to analyze fluxes, turbulence, and other boundary layer parameters; a climatological analysis of surface winds, fluxes and thermodynamic parameters for several years; an analysis of observed winds in the framework of Monin-Obukhov Similarity Theory (MOST); an analysis of the boundary layer winds and direction from a Doppler lidar; multi-year turbulence estimates through the boundary layer from a Doppler lidar; atmospheric boundary layer water vapor and relative humidity profiles from Raman lidar; cloud base height and boundary layer height from multiple sensors and satellite data; and finally site-specific atmospheric conditions, such as nocturnal low-level jets.

54 ENVIRONMENTAL SCIENCES↗

An Integrated Control Method for Supplemental Minisplit Heat Pumps in Existing Homes

The FSEC Energy Research Center(FSEC) at the University of Central Florida has investigated low-cost space-conditioning upgrade solutions for existing homes since 2014. The retrofits involve installing a modest capacity, centrally located, high efficiency, ductless, minisplit heat pump (MSHP) for use in conjunction with the home’s existing central space conditioning system (CSCS). This type of retrofit targets homes with older but not obsolete CSCSs that have not reached end of life, and presents a more cost-effective option to achieve space conditioning energy savings than outright CSCS replacement. This report describes results from investigating the energy savings potential, given adherence to comfort management, if the control of the MSHP and CSCS were integrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Shallow-to-Deep Convective Transition in the Amazon (Final Report)

The frequent and extensive deep cloud formations over the Amazon Basin provide a vast area of atmospheric heating in the Tropics, forcing large-scale global circulations on daily to secular time scales. Motivated by the importance of these systems to the global climate system and the well-documented seasonal cycle in rainfall over the Amazon Basin, this study focused on improving understanding of the processes governing these systems on seasonal time scales and their impact on the typical growth of convection from early afternoon through evening, termed the shallow-to-deep transition. This study is based on observations from the Department of Energy (DOE) ARM Mobile Facility (AMF) near Manacapuru, Brazil collected during the Observations and Modeling of the Green Ocean Amazon (GOAmazon) field campaign from 1 January 2014 to 30 November 2015, together with total column water vapor (CWV) and surface meteorological observations from a dense Global Navigation Satellite System (GNSS) network within 50 km of the AMF site provided by the CHUVA Program collected in coordination with the GOAmazon campaign. The specific objectives of this study were to address the following questions: 1) What environmental conditions support the shallow-to-deep convective transition over the Central Amazon? 2) How does the relative importance of these conditions compare during the wet and dry seasons? 3) How are these conditions modulated by basin-scale transient forcing? 4) How well are these processes captured by regional model simulations convective resolving scale? Our main hypothesis was that intra-seasonal atmospheric disturbances were a primary driver of rainfall during the wet season in the Central Amazon, while localized surface heating of the land was the primary driver of enhanced rainfall during the dry season. Overall, our findings supported our hypothesis, with the convectively active phase of atmospheric Kelvin waves strongly favoring the development of larger, more organized rain systems during the wet season, while localized isolated deep convection dominated the types of rain events seen during the dry season. These results have implications for the predictability of rainfall over the Central Amazon and for its representation in climate and weather models.

54 ENVIRONMENTAL SCIENCES↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Inventory Sensitivity Case

The Plateau to River (P2R) Model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by the Central Plateau Cleanup Company (CPCCo) at the Hanford Site in Washington State. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation file (ECF) is to describe an inventory sensitivity case of the CA base case. The inventory sensitivity case implements a change in the activity contribution from the vadose zone in the A Trenches Area model (for tritium (H-3) and iodine-129 (I-129)), BC Cribs and Trenches model (for I-129 and technetium-99 (Tc-99)), and the PUREX Area model (for H-3 and I-129). All other simulated inventories are identical to the CA base case. The simulation of F&T of contaminants reported in this case will support dose predictions as part of the Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Recharge Sensitivity Case

The Plateau-to-River (P2R) model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by the Central Plateau Cleanup Company (CPCCo) at the Hanford Site in south-central Washington State. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation file (ECF) is to describe a recharge sensitivity case of the CA base case. The recharge sensitivity case implements a change in the activity contribution from the vadose zone in the A Trenches Area model (for tritium [H-3] and iodine-129 [I-129]), BC Cribs and Trenches model (for I-129 and technetium-99 [Tc-99]), or the Plutonium Uranium Extraction (PUREX) Area model (for H-3 and I-129). All other simulated inventories are identical to the CA base case. The simulation of fate and transport of contaminants reported in this case will support dose predictions as part of the updated Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Study for Multifamily Building Ventilation and Indoor Air Quality

Weatherization Program Notice (WPN) 17-7 issued by the US Department of Energy (DOE) Weatherization Assistance Program (WAP) requires that buildings have ventilation in accordance with ASHRAE Standard 62.2-2016 (entitled Ventilation and Indoor Air Quality in Residential Buildings) in dwelling units weatherized under the program. The 2016 version of the standard expanded its scope of application to include all multifamily dwelling units. This has resulted in concerns for buildings where installing ventilation in individual units is costly or otherwise logistically difficult. Also, excessive ventilation rates could significantly increase energy costs, and may cause indoor air quality issues within the buildings. One deficiency that is noted is that the standard does not provide a credit for existing infiltration in multifamily buildings that reduces the required mechanical ventilation levels. This report details findings from a field study investigating envelope air-tightness, inter-unit connectivity, and indoor air quality in centrally ventilated high-rise multifamily buildings with central ventilation systems serving individual units in the state of New York. As allowed under WPN 17-7, the State of New York has a variance in the application of ASHRAE Standard 62.2-2016 in select types of multifamily buildings to provide time to determine how best to implement the standard. The purpose of this pilot study is to characterize the impact that weatherization and feasible ventilation improvements have on the indoor air quality of large, multifamily buildings with centrally ventilated apartments, as currently performed under WAP in the State of New York under their variance request (i.e., to implement ASHRAE Standard 62.2-2016 “to the greatest extent possible” in this type of multifamily building). A major goal is to determine if these practices improve or at least “do no harm” to the indoor air quality of the weatherized multifamily buildings and to the occupants themselves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biological particles and aerosol-cloud interactions in the Southern Great Plains (Final Report)

The United States Southern Great Plains (SGP) is the genesis for much of the warm season precipitation in the central and eastern United States. While atmospheric thermodynamics and large-scale dynamics play an important role in formation of precipitation, precipitation mechanisms are also sensitive to aerosols. Aerosols can suppress precipitation as cloud condensation nuclei (CCN) or act as ice nucleating particles (INP) in deep convective clouds. This project focused on understanding the role of primary biological aerosol particles (PBAP) in the region and its influence on cloud formation. Specifically, we focused on biological aerosol in the form of pollen, one type of PBAP that is emitted in large yet variable quantities from vegetation in the mid latitudes. Field observations provide evidence of pollen in the planetary boundary layer and pollen components in cloud droplets and fine particulate matter. Further, pollen grains can easily rupture when wet, forming smaller, sub pollen particles with sizes less than one micron. We evaluated the potential for PBAP events at the Department of Energy (DoE) SGP Atmospheric Radiation Measurement (ARM) research facility due to the rich dataset available. We also developed model simulations that accounted for pollen emission and the generation of sub pollen particles, which have been shown to be both cloud condensation nuclei and ice nucleating particles. The proposed work was designed to address the following questions: 1. What are the physical and chemical signatures of biological aerosol such as pollen in SGP ARM measurements? 2. What is the role of pollen-derived particles on deep convection and precipitation in the Central US? Using measurements from the DoE SGP ARM site and recent airborne campaigns, we evaluated the signatures of pollen and pollen-derived aerosols on optical properties, cloud properties and precipitation (Subba et al., 2021). We identified pollen-driven events over the data record and used the Weather Research and Forecasting Model with fully coupled chemistry (WRF-Chem) to conduct chemically realistic simulations of aerosols during and summer mesoscale convective events in the Southern Great Plains (Subba et al., in review). This work improved our understanding of the role of biological aerosol on clouds and precipitation in the Central United States and placed these results in context with anthropogenically-driven processes.

54 ENVIRONMENTAL SCIENCES↗

Biological particles and aerosol-cloud interactions in the Southern Great Plains

The United States Southern Great Plains (SGP) is the genesis for much of the warm season precipitation in the central and eastern United States. While atmospheric thermodynamics and large-scale dynamics play an important role in formation of precipitation, precipitation mechanisms are also sensitive to aerosols. Aerosols can suppress precipitation as cloud condensation nuclei (CCN) or act as ice nucleating particles (INP) in deep convective clouds. This project focused on understanding the role of primary biological aerosol particles (PBAP) in the region and its influence on cloud formation. Specifically, we focused on biological aerosol in the form of pollen, one type of PBAP that is emitted in large yet variable quantities from vegetation in the mid latitudes. Field observations provide evidence of pollen in the planetary boundary layer and pollen components in cloud droplets and fine particulate matter. Further, pollen grains can easily rupture when wet, forming smaller, sub pollen particles with sizes less than one micron. We evaluated the potential for PBAP events at the Department of Energy (DoE) SGP Atmospheric Radiation Measurement (ARM) research facility due to the rich dataset available. We also developed model simulations that accounted for pollen emission and the generation of sub pollen particles, which have been shown to be both cloud condensation nuclei and ice nucleating particles. The proposed work was designed to address the following questions: 1. What are the physical and chemical signatures of biological aerosol such as pollen in SGP ARM measurements? 2. What is the role of pollen-derived particles on deep convection and precipitation in the Central US? Using measurements from the DoE SGP ARM site and recent airborne campaigns, we evaluated the signatures of pollen and pollen-derived aerosols on optical properties, cloud properties and precipitation (Subba et al., 2021). We identified pollen-driven events over the data record and used the Weather Research and Forecasting Model with fully coupled chemistry (WRF-Chem) to conduct chemically realistic simulations of aerosols during and summer mesoscale convective events in the Southern Great Plains (Subba et al., in review). This work improved our understanding of the role of biological aerosol on clouds and precipitation in the Central United States and placed these results in context with anthropogenically-driven processes.

54 ENVIRONMENTAL SCIENCES↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Molybdenum Sleeve Experiments in Fully-Reflected Water-Moderated Triangular-Pitched U(6.90)O 2 Fuel Rod Lattices (1.55 cm Pitch)

The US Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories. The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water-moderated and -reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM-096, LEUCOMP-THERM-097, LEU-COMP-THERM-101, and LEU-COMP-THERM-102. The purpose of these experiments was to measure the effects of molybdenum in nearly-critical systems. The molybdenum was introduced into the fuel arrays as tubular sleeves that surrounded some of the fuel rods in the fuel arrays measured. Four hundred molybdenum tubes nominally 12.7 mm outside diameter, 498 mm long, with 0.762 mm wall thickness were provided for the experiments by the Institut de Radioprotection et de Sûreté Nucléaire (IRSN). Small polyethylene adapters at each end of the tubes were used to center each tube on a fuel rod in the assembly. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 1261 fuel rod positions on a pitch of 0.610 in (1.5494 cm) in a series of 20 hexagonal rings surrounding the central fuel rod. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The five critical experiments in this series were performed in August through December 2022, in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility. Case 1 had no molybdenum sleeves, Case 2 had 208 molybdenum sleeves clustered at the center of the array, Case 3 had 397 molybdenum sleeves clustered at the center of the array, Case 4 had 175 molybdenum sleeves in the central position and in five alternating hexagonal rings, and Case 5 had 331 molybdenum sleeves in the central position and in seven alternating hexagonal rings. All five critical experiments are judged to be acceptable as benchmark experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗