Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Application of pixel array detectors at x-ray synchrotrons.

Pixel array detectors have only recently been seriously used at x-ray synchrotrons. We describe the application of a digital pixel array detector (Pilatus100k) to a variety of synchrotron experiments at the Advanced Photon Source at Argonne National Laboratory. The Pilatus100k was developed at the Paul Scherrer Institut (PSI). It has been commercialized by a PSI spinoff (Dectrics Ltd.) This is the first commercially available pixel array detector for x-ray synchrotron applications. The APS synchrotron provides tunable x-ray pulses with duration of {approx}80 ps and a repetition period of 153 ns (24-bunch mode). The Pilatus100k is a direct detection x-ray detector where each 172 micron pixel counts individual x-ray pulses above a lower threshold. It consists of {approx}100k pixels each of which is capable of single-photon counting (>3 keV) at count rates up to {approx}1 MHz. In addition, the Pilatus100k is an electronically gateable detector. We present data showing that the Pilatus100k is capable of isolating a single x-ray bunch at the APS in 24 bunch mode. We will also present a variety of different experiments exploiting the unique capabilities of the Pilatus100k.

43 PARTICLE ACCELERATORS↗

SWIFT-BAT HARD X-RAY SKY MONITORING UNVEILS THE ORBITAL PERIOD OF THE HMXB IGR J18219–1347

IGR J18219–1347 is a hard X-ray source discovered by INTEGRAL in 2010. We have analyzed the X-ray emission of this source exploiting the Burst Alert Telescope (BAT) survey data up to 2012 March and the X-Ray Telescope (XRT) data that include also an observing campaign performed in early 2012. The source is detected at a significance level of ∼13 standard deviations in the 88 month BAT survey data, and shows a strong variability along the survey monitoring, going from high intensity to quiescent states. A timing analysis on the BAT data revealed an intensity modulation with a period of P {sub 0} = 72.44 ± 0.3 days. The significance of this modulation is about seven standard deviations in Gaussian statistics. We interpret it as the orbital period of the binary system. The light curve folded at P {sub 0} shows a sharp peak covering ∼30% of the period, superimposed to a flat level roughly consistent with zero. In the soft X-rays the source is detected only in 5 out of 12 XRT observations, with the highest recorded count rate corresponding to a phase close to the BAT folded light-curve peak. The long orbital period and the evidence that the source emits only during a small fraction of the orbit suggests that the IGR J18219–1347 binary system hosts a Be star. The broadband XRT+BAT spectrum is well modeled with a flat absorbed power law with a high-energy exponential cutoff at ∼11 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DAmodel: hierarchical Bayesian modelling of DA white dwarfs for spectrophotometric calibration

We use hierarchical Bayesian modelling to calibrate a network of 32 all-sky faint DA white dwarf (DA WD) spectrophotometric standards (⁠16.5 < V , 19.5⁠) alongside three CALSPEC standards, from 912 Å to 32 μm. The framework is the first of its kind to jointly infer photometric zero points and WD parameters (surface gravity log g⁠, effective temperature T eff ⁠, extinction A V ⁠, dust relation parameter R V ) by simultaneously modelling both photometric and spectroscopic data. We model panchromatic Hubble Space Telescope Wide Field Camera 3 (HST/WFC3) UVIS and IR photometry, HST/STIS UV spectroscopy, and ground-based optical spectroscopy to sub-per cent precision. Photometric residuals for the sample are the lowest yet yielding < 0.004 mag RMS on average from the UV to the NIR, achieved by jointly inferring time-dependent changes in system sensitivity and WFC3/IR count-rate nonlinearity. Our GPU-accelerated implementation enables efficient sampling via Hamiltonian Monte Carlo, critical for exploring the high-dimensional posterior space. The hierarchical nature of the model enables population analysis of intrinsic WD and dust parameters. Inferred spectral energy distributions from this model will be essential for calibrating the James Webb Space Telescope as well as next-generation surveys, including Vera Rubin Observatory’s Legacy Survey of Space and Time and the Nancy Grace Roman Space Telescope.

methods: statistical↗

A multicomponent matched filter cluster confirmation tool for eROSITA: initial application to the RASS and DES-SV data sets

We describe a multi-component matched filter cluster confirmation tool (MCMF) designed for the study of large X-ray source catalogs produced by the upcoming X-ray all-sky survey mission eROSITA. We apply the method to confirm a sample of 88 clusters with redshifts $0.05<z<0.8$ in the recently published 2RXS catalog from the ROSAT all-sky survey (RASS) over the 208 deg$^2$ region overlapped by the Dark Energy Survey (DES) science verification (DES-SV) dataset. In our pilot study, we examine all X-ray sources, regardless of their extent. Our method employs a multi-color red sequence (RS) algorithm that incorporates the X-ray count rate and peak position in determining the region of interest for followup and extracts the positionally and color weighted optical richness $\lambda_{\mathrm{MCMF}}$ as a function of redshift for each source. Peaks in the $\lambda_{\mathrm{MCMF}}$-redshift distribution are identified and used to extract photometric redshifts, richness and uncertainties. The significances of all optical counterparts are characterized using the distribution of richnesses defined along random lines of sight. These significances are used to extract cluster catalogs and to estimate the contamination by random superpositions of unassociated optical systems. The delivered photometric redshift accuracy is $\delta z / (1+z)=0.010$. We find a well defined X-ray luminosity-$\lambda_{\mathrm{MCMF}}$ relation with an intrinsic scatter of $\delta \ln(\lambda_\mathrm{MCMF}| L_\mathrm{x})=0.21$. Matching our catalog with the DES-SV redMaPPer catalog yields good agreement in redshift and richness estimates; comparing our catalog with the South Pole Telescope (SPT) selected clusters shows no inconsistencies. SPT clusters in our dataset are consistent with the high mass extension of the RASS based $\lambda_{\mathrm{MCMF}}$-mass relation

79 ASTRONOMY AND ASTROPHYSICS↗

XRISM view of a stellar flare: High-resolution Fe K spectra of HR 1099, an RS CVn-type star

A high-resolution X-ray spectroscopic observation was made of the RS CVn-type binary star HR 1099 using the Resolve instrument onboard XRISM for its calibration purposes. During the $\sim$400 ks telescope time covering 1.5 binary orbit, a flare lasting for $\sim$100 ks was observed with a released X-ray radiation energy of ${\sim }10^{34}$ erg, making it the first stellar flare ever observed with an X-ray microcalorimeter spectrometer. The flare peak count rate is 6.4 times higher than that in quiescence and is distinguished clearly in time thanks to the long telescope time. Many emission lines were detected in the 1.7–10 keV range both in the flare and quiescent phases. Using the high spectral resolution of Resolve in the Fe K band (6.5–7.0 keV), we resolved the inner-shell lines of Fe XIX-XXVI as well as the outer-shell lines of Fe XXV-XXVI . These lines have peaks in the contribution functions at different temperatures over a wide range, allowing us to construct the differential emission measure (DEM) distribution over the electron temperature of 1–10 keV (roughly 10–100 MK) based only on Fe lines, thus without an assumption of the elemental abundance. The reconstructed DEM has a bimodal distribution, and only the hotter component increased during the flare. The elemental abundance was derived based on the DEM distribution thus constructed. A significant abundance increase was observed during the flare for Ca and Fe, which are some of the elements with the lowest first ionization potential among those analyzed, but not for Si, S, and Ar. This behavior is seen in some giant solar flares and the present result is a clear example in stellar flares.

Astronomy and AstroPhysics↗

Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set

Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dust loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel-plate avalanche counters for heavy-ion beam tracking: History and mysteries

Despite being an old detector concept, position-sensitive parallel-plate avalanche counters (PPACs) remain widely used today for heavy-ion position and timing measurements. In modern rare isotope beam facilities and large-acceptance fragment separators, PPACs are used to characterize beam properties (diagnostics), facilitate beam delivery (tuning), and provide event-by-event beam tracking for particle identification (PID). Most popular particle localization methods in PPAC detectors are based on strip electrodes electrically connected to resistive-chain circuits or delay lines. More exotic systems include optical readouts based on recording electroluminescence light with high-granularity photodetector arrays or high-resolution resistive anode electrodes. PPACs with conventional resistive-chain or delay-line readouts achieve typical position and time resolutions of below 1 mm ( σ ) and around 150 ps ( σ ), respectively. In addition, delay-line systems are capable of counting rates above several hundred kHz for beam areas of a few millimeters square, and around 1 MHz for larger beam sizes. Resistive-chain readouts have limited rates of a few tens of kHz. A review of the operation principles and performance of PPAC detectors is presented in this paper. We will discuss decades-long experience building and operating PPACs developed at the National Superconducting Cyclotron Laboratory, and then refined at the Facility for Rare Isotope Beams (FRIB), mostly focusing on the delay-line readout technique (DLPPAC). We will also discuss problems that arise due to electric discharges at high rates and briefly describe ongoing developments at FRIB. Published by the American Physical Society 2024

Physics↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dark counts in optical superconducting transition-edge sensors for rare-event searches

Superconducting transition-edge sensors (TESs) are a type of quantum sensor known for their high single-photon detection efficiency and low background. This makes TESs ideal for particle-physics experiments searching for rare events. In this work, we present a comprehensive characterization of the background in optical TESs, distinguishing three types of events: electrical-noise, high-energy, and photonlike events. We introduce computational methods to automate the classification of events. We experimentally verify and simulate the source of the high-energy events. We also isolate the photonlike events, the expected signal in dielectric haloscopes searching for dark-matter dark photons, and achieve a photonlike dark-count rate of 3.6× 10 − 4 in the 0.8–3.2 eV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distinguishing finite-momentum superconducting pairing states with two-electron photoemission spectroscopy

Here, we show theoretically that double photoemission (2e-ARPES) may be used to identify the pairing state in superconductors in which the Cooper pairs have a nonzero center-of-mass momentum, q cm . We theoretically evaluate the 2e-ARPES counting rate P (2) for the cases of a d x 2 -y 2 -wave superconductor, a pair-density-wave (PDW) phase, and a Fulde-Ferrel-Larkin-Ovchinnikov (FFLO) phase. We show that P (2) provides direct insight into the center-of-mass momentum and spin state of the superconducting condensate, and thus can distinguish between these three different superconducting pairing states. In addition, P (2) can be used to map out the momentum dependence of the superconducting order parameter. Our results identify 2e-ARPES as an ideal tool for identifying and probing q cm ≠ 0 superconducting pairing states in superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spectroscopy of Li Λ 9 by electroproduction

Background: In the absence of accurate data on the free two-body hyperon-nucleon interaction, the spectra of hypernuclei can provide information on the details of the effective hyperon-nucleon interaction. Purpose: To obtain a high-resolution spectrum for the 9 Be(e,e'K + ) 9 Λ Li reaction. Method: Electroproduction of the hypernucleus 9 Λ Li has been studied for the first time with sub-MeV energy resolution in Hall A at Jefferson Lab on a 9 Be target. In order to increase the counting rate and to provide unambiguous kaon identification, two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. Results: The cross section to low-lying states of 9 Λ Li is concentrated within 3 MeV of the ground state and can be fitted with four peaks. The positions of the doublets agree with theory while a disagreement could exist with respect to the relative strengths of the peaks in the doublets. A Λ separation energy, B Λ , of 8.36±0.08 (stat.) ±0.08 (syst.) MeV was measured, in agreement with an earlier experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution hypernuclear spectroscopy at Jefferson Lab, Hall A

The experiment E94-107 in Hall A at Jefferson Lab started a systematic study of high resolution hypernuclear spectroscopy in the 0 p -shell region of nuclei such as the hypernuclei produced in electroproduction on 9 Be, 12 C and 16 O targets. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a ring-imaging Cherenkov detector were added to the Hall A standard equipment. The high-quality beam, the good spectrometers and the new experimental devices allowed us to obtain very good results. Here, measurable strength with sub-MeV energy resolution was recorded for the core-excited states of $^{12}_{Λ}$B. A high-quality$^{16}_{Λ}N hypernuclear spectrum was likewise obtained. A first measurement of the Λ binding energy for Lambda 16N, calibrated against the elementary reaction on hydrogen, was obtained with high precision, 13.76 ± 0.16 MeV. Similarly, the first$^{9}_{Λ}Li hypernuclear spectrum shows general agreement with theory (distorted-wave impulse approximation with the SLA and BS3 electroproduction models and shell-model wave functions). Some disagreement exists with respect to the relative strength of the states making up the first multiplet. A Λ separation energy of 8.36 MeV was obtained, in agreement with previous results. It has been observed that the electroproduction of hypernuclei can provide information complementary to that obtained with hadronic probes and the γ-ray spectroscopy technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Limits on the Existence of sub-MeV Sterile Neutrinos from the Decay of 7 Be in Superconducting Quantum Sensors

Sterile neutrinos are natural extensions to the standard model of particle physics and provide a possible portal to the dark sector. We report a new search for the existence of sub-MeV sterile neutrinos using the decay-momentum reconstruction technique in the decay of 7 Be. The experiment measures the total energy of the 7 Li daughter atom from the electron capture decay of 7 Be implanted into sensitive superconducting tunnel junction (STJ) quantum sensors. Here, this first experiment presents data from a single STJ operated at a low count rate for a net total of 28 days, and provides exclusion limits on sterile neutrinos in the mass range from 100 to 850 keV that improve upon previous work by up to an order of magnitude.

42 ENGINEERING↗

Measuring the Debye energy in superconductors via two-electron photoemission spectroscopy

In this work, we demonstrate theoretically that double angle resolved photoemission spectroscopy (2eARPES) can directly probe the existence of Cooper pairs away from the Fermi surface, and can thus provide insight into the characteristic energy scale around the Fermi surface, the Debye energy, in which electrons are bound into Cooper pairs. To this end, we compute the photoelectron counting rate 𝑃 (2) in two different types of unconventional superconductors, a 𝑑 𝑥 2 −𝑦 2 -wave superconductor, and a topological superconductor with a broken time-reversal symmetry. We show that 𝑃 (2) provides insight into the relative strength of intra- and interband pairing in multiband systems, as well as into the spin polarization of the bands.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The 40m General Purpose Small-Angle Neutron Scattering Instrument at Oak Ridge National Laboratory

A high-flux, 40m long small-angle neutron scattering (SANS) instrument has been constructed at Oak Ridge National Laboratory (ORNL). The facility utilizes a mechanical velocity selector, pinhole collimation and a high count-rate (> 105 Hz), large-area (1m2) two-dimensional position-sensitive detector. The incident wavelength (λ), resolution (Δλ/λ), incident collimation and sample-detector distance are independently variable under computer control. The detector can translate 45cm off axis to increase the overall Q-range (< 0.001 < Q = 4πλ-1sin θ < 1 Å-1), where 2θ is the angle of scatter. The design and characteristics of this instrument are described along with examples of scattering data to illustrate the performance.

biology↗

High-resolution X-ray emission spectroscopy with transition-edge sensors: present performance and future potential

X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low efficiency of wavelength-dispersive X-ray spectrometer technology has limited the use of XES, especially in combination with weaker laboratory X-ray sources. More efficient energy-dispersive detectors have either insufficient energy resolution because of the statistical limits described by Fano or too low counting rates to be of practical use. This paper updates an approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs). TES arrays are discussed and compared with conventional methods, and shown under which circumstances they are superior. It is also shown that a TES array can be integrated into a table-top time-resolved X-ray source and a soft X-ray synchrotron beamline to perform emission spectroscopy with good chemical sensitivity over a very wide range of energies.

Uhlig, J.↗

X-ray Characterization of a Multichannel Smart-Pixel Array Detector

The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

CMOS ASIC↗