At least 865 records · Page 48

POST-TEST EXAMINATIONS OF A LOCA SAMPLE FROM AN IRRADIATED HIGH-BURNUP PWR M5 FUEL ROD

A LOCA integral test with high burnup PWR M5 fuel rod was conducted in the Irradiated Fuel Examination Laboratory through the complete LOCA sequence: heating the LOCA sample to 300ºC and pressurizing the internal pressure to 8.27 MPa, heating at 5ºC/s from 300 to 1200ºC, holding in steam for 90s at 1200ºC, cooling at 3ºC/s to 800ºC, followed by water quench and rapid cooling to 100ºC. After LOCA testing, examinations, such as the fuel fragmentation analysis, burst and ballooning characterization, axial strain measurement, and microstructural examinations were performed. Metallographic examinations of an as-irradiated high burnup sample adjacent to the LOCA test sample revealed a bonding layer between the fuel and cladding. The posttest LOCA examinations indicates the corrosion layer formed during normal operations in the commercial reactor might provide a protection against the steam oxidation at high temperatures for test times performed in this work. The microstructure of the as-irradiated fuel is compared to the microstructure of the post-LOCA test fuel. Posttest LOCA examination on unirradiated post-tests Zr cladding samples was conducted, which served as baseline data for in cell testing with irradiated samples. The results obtained with irradiated PWR high burnup M5 fuel rad were compared to the LOCA test data obtained with irradiated BWR high burnup Zircaloy-2 fuel rod at Argonne national Laboratory.

Yan, Yong↗

Enhancement of Hot Corrosion Resistance of Modified 9Cr-1Mo Steel Through Surface Nanostructuring and Pre-oxidation

Nanosize grains of ~ 65 nm were developed with large misorientation angles of grain boundaries in surface region of normalized and tempered modified 9Cr-1Mo steel by ultrasonic shot peening (USSP) with hard steel balls of 3 mm diameter. The surface roughness and the depth of nanostructured surface region were found to increase with the duration of USSP from 0.5 to 5 min. Hot corrosion tests were performed for the Un-USSP and the samples USSPed for the durations of 0.25 and 1.5 min and also for the samples subjected to USSP and subsequently pre-oxidation at 600 °C for 4 h. The hot corrosion resistance at 600 °C under 100% NaCl coating was significantly improved by USSP for 1.5 min and subsequent pre-oxidation at 600 °C for 4 h. The results are discussed in terms of the formation of more uniform and effective protective iron–chromium oxide layer on the USSPed surface from the subsequent pre-oxidation treatment, prior to hot corrosion of the specimens under 100% NaCl coating at 600 °C.

36 MATERIALS SCIENCE↗

Hydrogen pickup mechanism in zirconium alloys - 2016-0055

Because hydrogen ingress into zirconium cladding can cause embrittlement and limit cladding lifetime, hydrogen pickup during corrosion is a critical life-limiting degradation mechanism for nuclear fuel. However, mechanistic knowledge of the oxidation and hydrogen pickup mechanisms is still lacking. In an effort to develop such knowledge, we conducted a comprehensive study that included detailed experiments combined with oxidation modeling. We review this set of results conducted on zirconium alloys herein and articulate them into a unified corrosion theoretical framework. First, the hydrogen pickup fraction (f{sub H}) was accurately measured for a specific set of alloys specially designed to determine the effects of alloying elements, microstructure, and corrosion kinetics on f{sub H}. We observed that f{sub H} was not constant and increased until the kinetic transition and decreased at the transition. F{sub H} depended on the alloy and was lower for niobium-containing alloys. These results led us to hypothesize that hydrogen pickup during corrosion results from the need to balance the charge during the corrosion reaction such that f{sub H} decreases when the rate of electron transport through the protective oxide increases. To assess this hypothesis, two experiments were performed: (1) micro-X-ray absorption near-edge spectroscopy (μ-XANES) to investigate the evolution of the oxidation state of alloying elements when incorporated in the growing oxide and (2) in situ electrochemical impedance spectroscopy (EIS) to measure oxide resistivity as a function of exposure time on different alloys. With the use of these results, we developed an analytical zirconium alloy corrosion model based on the coupling of oxygen vacancies and electron currents. Both modeling and EIS results show that as the oxide electric conductivity decreases the f{sub H} increases. These new results support the general hypothesis of charge balance. The model quantitatively and qualitatively predicts the differences observed in oxidation kinetics and hydrogen pickup fraction between different alloys. (authors)

36 MATERIALS SCIENCE↗

Corrosion Evaluation of Aircraft Depainting Chemicals

The National Aeronautics and Space Administration is participating in an interagency task agreement with the Environmental Protection Agency and the United States Air Force to evaluate alternative technologies for aerospace depainting operations that do not adversely affect the environment. An element of this study is directed towards the evaluation of environmentally advantaged chemical paint strippers, specifically, paint strippers that do not contain methylene chloride. Eight environmentally advantaged, or alternative, chemical paint strippers and two methylene chloride, or baseline, paint strippers were obtained from various manufacturers and incorporated into the depainting study. In addition to being evaluated on their ability to remove paint, the potential of these chemicals to promote corrosion and hydrogen embrittlement was evaluated. The corrosion and hydrogen embrittlement potential of the chemical paint strippers are presented in this report.

McGill, Preston↗

Turning a native or corroded Mg alloy surface into an anti-corrosion coating in excited CO 2

Despite their energy-efficient merits as promising light-weight structural materials, magnesium (Mg) based alloys suffer from inadequate corrosion resistance. One primary reason is that the native surface film on Mg formed in air mainly consists of Mg(OH) 2 and MgO, which is porous and unprotective, especially in humid environments. Here, we demonstrate an environmentally benign method to grow a protective film on the surface of Mg/Mg alloy samples at room temperature, via a direct reaction of already-existing surface film with excited CO 2 . Moreover, for samples that have been corroded obviously on surface, the corrosion products can be converted directly to create a new protective surface. Mechanical tests show that compared with untreated samples, the protective layer can elevate the yield stress, suppress plastic instability and prolong compressive strains without peeling off from the metal surface. This environmentally friendly surface treatment method is promising to protect Mg alloys, including those already-corroded on the surface.

36 MATERIALS SCIENCE↗

Turbine Airfoil Deposition Models

Gas turbine failures associated with sea-salt ingestion and sulfur-containing fuel impurities have directed attention to alkali sulfate deposition and the associated hot corrosion of gas turbine (GT) blades under some GT operating conditions. These salt deposits form thin, molten films which undermine the protective metal oxide coating normally found on GT blades. The prediction of molten salt deposition, flow and oxide dissolution, and their effects on the lifetime of turbine blades are examined. Goals include rationalizing and helping to predict corrosion patterns on operational GT rotor blades and stators, and ultimately providing some of the tools required to design laboratory simulators and future corrosion-resistant high-performance engines. Necessary background developments are reviewed first, and then recent results and tentative conclusions are presented along with a brief account of the present research plans.

Rosner, D. E.↗

Electrochemical Impedance Spectroscopy of Alloys in a Simulated Space Shuttle Launch Environment

Corrosion studies began at NASA/Kennedy Space Center in 1966 during the Gemini/Apollo Programs with the evaluation of long-term protective coatings for the atmospheric protection of carbon steel. An outdoor exposure facility on the beach near the launch pad was established for this purpose at that time. The site has provided over 35 years of technical information on the evaluation of the long-term corrosion performance of many materials and coatings as well as on maintenance procedures. Results from these evaluations have helped NASA find new materials and processes that increase the safety and reliability of our flight hardware, launch structures, and ground support equipment. The launch environment at the Kennedy Space Center (KSC) is extremely corrosive due to the combination of ocean salt spray, heat, humidity, and sunlight. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pad were rendered even more severe by the acidic exhaust from the solid rocket boosters. Over the years, many materials have been evaluated for their corrosion performance under conditions similar to those found at the launch pads. These studies have typically included atmospheric exposure and evaluation with conventional electrochemical methods such as open circuit potential (OCP) measurements, polarization techniques, and electrochemical impedance spectroscopy (EIS). The atmosphere at the Space Shuttle launch site is aggressive to most metals and causes severe pitting in many of the common stainless steel alloys such as type 304L stainless steel (304L SS). A study was undertaken to find a more corrosion resistant material to replace the existing 304L SS tubing. This paper presents the results from atmospheric exposure as well as electrochemical measurements on the corrosion resistance of AL-6XN (UNS N08367) and 254-SMO (UNS S32154). Type 304L SS (UNS S30403) was used as a control. Conditions at the Space Shuttle launch pad were simulated by using a hydrochloric acid (HC1) and alumina (Al203) slurry rinse for the atmospheric exposure and an electrolyte consisting of 3.55% sodium chloride (NaC1) with increased concentrations of hydrochloric acid (HC1) for the electrochemical measurements. The results from both types of measurements revealed the superior corrosion performance of the higher-alloyed materials. Unlike 304L SS, 254-SMO and AL-6XN exhibited a significantly improved resistance to corrosion as the concentration of hydrochloric acid in he 3.55% NaCl electrolyte solution was increased.

Calle, L. M.↗

Electrochemical Investigation of Corrosion in the Space Shuttle Launch Environment

Corrosion studies began at NASA/Kennedy Space Center in 1966 during the Gemini/Apollo Programs with the evaluation of long-term protective coatings for the atmospheric protection of carbon steel. An outdoor exposure facility on the beach near the launch pad was established for this purpose at that time. The site has provided over 35 years of technical information on the evaluation of the long-term corrosion performance of many materials and coatings as well as on maintenance procedures. Results from these evaluations have helped NASA find new materials and processes that increase the safety and reliability of our flight hardware, launch structures, and ground support equipment. The launch environment at the Kennedy Space Center (KSC) is extremely corrosive due to the combination of ocean salt spray, heat, humidity, and sunlight. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pad were rendered even more severe by the acidic exhaust from the solid rocket boosters. It has been estimated that 70 tons of hydrochloric acid (HC1) are produced during a launch. The Corrosion Laboratory at NASA/KSC was established in 1985 to conduct electrochemical studies of corrosion on materials and coatings under conditions similar to those encountered at the launch pads. I will present highlights of some of these investigations.

Calle, L. M.↗

Vapor Space Corrosion Testing Simulating The Environment Of Hanford Double Shell Tanks

As part of an integrated program to better understand corrosion in the high level waste tanks, Hanford has been investigating corrosion at the liquid/air interface (LAI) and at higher areas in the tank vapor space. This current research evaluated localized corrosion in the vapor space over Hanford double shell tank simulants to assess the impact of ammonia and new minimum nitrite concentration limits, which are part of the broader corrosion chemistry limits. The findings from this study showed that the presence of ammonia gas (550 ppm) in the vapor space is sufficient to reduce corrosion over the short-term (i.e. four months) for a Hanford waste chemistry (SY102 High Nitrate). These findings are in agreement with previous studies at both Hanford and SRS which showed ammonia gas in the vapor space to be inhibitive. The presence of ammonia in electrochemical test solution, however, was insufficient to inhibit against pitting corrosion. The effect of the ammonia appears to be a function of the waste chemistry and may have more significant effects in waste with low nitrite concentrations. Since high levels of ammonia were found beneficial in previous studies, additional testing is recommended to assess the necessary minimum concentration for protection of carbon steel. The new minimum R value of 0.15 was found to be insufficient to prevent pitting corrosion in the vapor space. The pitting that occurred, however, did not progress over the four-month test. Pits appeared to stop growing, which would indicate that pitting might not progress through wall.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of passive corrosion studies of carbon steel in concrete in the context of disposal of HLW and spent fuel in Belgium

The Supercontainer (SC) design is the preferred option for the final disposal of high level nuclear waste and spent fuel in Belgium. The SC consists of a carbon steel overpack surrounded by a very thick concrete buffer, contained within a stainless steel envelope. In this highly alkaline environment of the annulus and under normal conditions (without the ingress of aggressive species), the carbon steel overpack will be protected by a passive oxide film, which is believed to result in very low and almost negligible uniform corrosion rates. This paper discusses the modeling efforts simulating the evolution of various parameters that can potentially influence the corrosion processes (temperature, pH, saturation degree and concentration of aggressive species). The outcome of the Belgian experimental program to study the passive uniform corrosion of carbon steel in concrete is also addressed. Long-term uniform corrosion rates are determined using different independent techniques (hydrogen gas measurements by means of manometric gas cells or pressure transducers, long-term passive current density measurements). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SAVY-4000 Corrosion Evaluation Plan

Nuclear material packages, with few exceptions, outside of an approved engineered contamination barrier must meet packaging, surveillance, and testing requirements designed to protect workers from airborne contamination per Department of Energy (DOE) Manual 441.1-1, Nuclear Material Packaging. The SAVY-4000 containers were developed at Los Alamos National Laboratory (LANL) in conjunction with Nuclear Filter Technology Inc. (NFT Inc.) as a general purpose vented manually-compliant container system for staging and storage of plutonium for LANL and the DOE complex. The SAVY-4000 containers have a 316L stainless steel containment barrier, which was selected based on its corrosion resistant properties. These containers were approved for use in 2014 with a five-year design life; LANL requested and DOE has approved lifetime extension from 5 to 15 years. The 10-year lifetime extension was proposed as a conservative recommendation based on the corrosion observations for the metal components in surveillance and results from laboratory studies. Extensive accelerated aging studies have been done on the SAVY-4000 O-ring with very little evidence of significant degradation when subjected to aggressive elevated temperature and radiation conditions. Therefore, our current conservative lifetime estimate for the O-ring and the filter is 40 years at 80°C. Additional work is ongoing in a phased approach to further extend the design life of the Manual compliant SAVY-4000 storage container; the limiting component for further life extension is still the 316L containment barrier.

36 MATERIALS SCIENCE↗

High temperature environmental effects on metals

The gas turbine engine was used as an example to predict high temperature environmental attack on metals. Environmental attack in a gas turbine engine derives from high temperature, combustion products of the air and fuel burned, and impurities. Of all the modes of attack associated with impurity effects, hot corrosion was the most complicated mechanistically. Solutions to the hot corrosion problem were sought semi-empirically in: (1) improved alloys or ceramics; (2) protective surface coating; (3) use of additives to the engine environment; and (4) air/fuel cleanup to eliminate harmful impurities.

Grisaffe, S. J.↗

Evaluation of inorganic zinc-rich primers using Electrochemical Impedance Spectroscopy (EIS) in combination with atmospheric exposure

This investigation explored the use of Electrochemical Impedance Spectroscopy (EIS) in combination with atmospheric exposure as a short term method for analyzing the performance of twenty-one commercially available zinc-rich primers. The twenty-one zinc-rich primers were: Carboline CZ-11, Ameron Devoe-Marine Catha-Coat 304, Briner V-65, Ameron D-21-9, Sherwin Williams Zinc Clad II, Carboline CZ-D7, Ameron D-4, Dupont Ganicin 347WB, Porter TQ-4374H, Inorganic Coatings IC-531, Subox Galvanox IV, Southern Coatings Chemtec 600, GLidden Glidzinc 5530, Byco SP-101, Tnemec 90E-75, Devoe Catha-Coat 302H, Glidden Glidzinc 5536, Koppers 701, Ameron D-21-5, Coronado 935-152, and Subox Galvanox V. Data were also collected on galvanized steel for comparison purposes. A library of Bode magnitude plots was generated for each coating including curves for the initial time and after each week of atmospheric exposure at the Beach Corrosion Test site near the Space Shuttle launch pad at the Kennedy Space Center for up to four weeks. Subsequent measurements were collected after 8 weeks and after one year of atmospheric exposure. Analysis of the impedance data was performed with the purpose of identifying parameters that could be used to predict the long-term performance of zinc-rich primers. It has been shown that there is a correlation between the long-term performance of zinc-rich primers and several parameters obtained from EIS measurements in combination with atmospheric exposure. The equivalent circuit R2(R2C(R3W)) provided a satisfactory fit for the EIS data. The corrosion potential and the R2 resistance are parameters indicative of the galvanic mechanism of protection. The capacitance of the coating is related to the barrier mechanism of protection.

Calle, Luz M.↗

Resistance of Silicon Nitride Turbine Components to Erosion and Hot Corrosion/oxidation Attack

Silicon nitride turbine components are under intensive development by AlliedSignal to enable a new generation of higher power density auxiliary power systems. In order to be viable in the intended applications, silicon nitride turbine airfoils must be designed for survival in aggressive oxidizing combustion gas environments. Erosive and corrosive damage to ceramic airfoils from ingested sand and sea salt must be avoided. Recent engine test experience demonstrated that NT154 silicon nitride turbine vanes have exceptional resistance to sand erosion, relative to superalloys used in production engines. Similarly, NT154 silicon nitride has excellent resistance to oxidation in the temperature range of interest - up to 1400 C. Hot corrosion attack of superalloy gas turbine components is well documented. While hot corrosion from ingested sea salt will attack silicon nitride substantially less than the superalloys being replaced in initial engine applications, this degradation has the potential to limit component lives in advanced engine applications. Hot corrosion adversely affects the strength of silicon nitride in the 850 to 1300 C range. Since unacceptable reductions in strength must be rapidly identified and avoided, AlliedSignal and the NASA Lewis Research Center have pioneered the development of an environmental life prediction model for silicon nitride turbine components. Strength retention in flexure specimens following 1 to 3300 hour exposures to high temperature oxidation and hot corrosion has been measured and used to calibrate the life prediction model. Predicted component life is dependent upon engine design (stress, temperature, pressure, fuel/air ratio, gas velocity, and inlet air filtration), mission usage (fuel sulfur content, location (salt in air), and times at duty cycle power points), and material parameters. Preliminary analyses indicate that the hot corrosion resistance of NT154 silicon nitride is adequate for AlliedSignal's initial engine applications. Protective coatings and/or inlet air filtration may be required to achieve required ceramic component lives in more aggressive environments.

Strangmen, Thomas E.↗

Corrosion Activities at the NASA Kennedy Space Center

This report documents summer faculty fellow efforts in the corrosion test bed at the NASA Kennedy Space Center. During the summer of 2002 efforts were concentrated on three activities: a short course on corrosion control for KSC personnel, evaluation of commercial wash additives used for corrosion control on Army aircraft, and improvements in the testing of a new cathodic protection system under development at KSC.

Heidersbach, Robert H.↗

An Assessment of Using Vibrational Compaction of Calcined HLW and LLW in DWPF Canisters

Since 1963, the INEL has calcined almost 8 million gallons of liquid mixed waste and liquid high-level waste, converting it to some 1.1 million gallons of dry calcine (about 4275.0 m3), which consists of alumina-and zirconia-based calcine and zirconia-sodium blend calcine. In addition, if all existing and projected future liquid wastes are solidified, approximately 2,000 m3 of additional calcine will be produced primarily from sodium-bearing waste. Calcine is a more desirable material to store than liquid radioactive waste because it reduces volume, is much less corrosive, less chemically reactive, less mobile under most conditions, easier to monitor and more protective of human health and the environment. This paper describes the technical issue involved in the development of a feasible solution for further volume reduction of calcined nuclear waste for transportation and long term storage, using a standard DWPF canister. This will be accomplished by developing a process wherein the canisters are transported into a vibrational machine, for further volume reduction by about 35%. The random compaction experiments show that this volume reduction is achievable. The main goal of this paper is to demonstrate through computer modeling that it is feasible to use volume reduction vibrational machine without developing stress/strain forces that will weaken the canister integrity. Specifically, the paper presents preliminary results of the stress/strain analysis of the DWPF canister as a function of granular calcined height during the compaction and verifying that the integrity of the canister is not compromised. This preliminary study will lead to the development of better technology for safe compactions of nuclear waste that will have significant economical impact on nuclear waste storage and treatment. The preliminary results will guide us to find better solutions to the following questions: 1) What are the optimum locations and directions (vertical versus horizontal or both of them) of applying the vibrational forces? 2) What is best mode of operation: first fill the canister with calcined waste and then vibrate it and refill it again, or apply vibrational forces during the filling process. By optimum or best we mean less creation of stress/strain forces during the volume reduction vibration process. Lessons learnt: This preliminary study shows that; 1) The maximum stress concentration always occurs in the canister wall, however its location varies and depends on the loading condition, and vibration process. 2) The proposed vibrational process would not cause any damages to the granulated calcined waste. 3) The first natural frequency of the longitudinal vibration of the canister is around 400 Hz, which is far away from the applied vibrational frequencies and from possibility of resonance phenomena that may cause damage to the canister 4) The relationship between the maximum internal stress and the frequency of the applied load is not parabolic. 5) The mechanical properties of the granulated calcined nuclear waste have small impact on the internal stress of the canister. Finally, the calculated data suggested that applying vibrational forces will keep the entire canister whole without any indication of development defects, and will have significant economical benefits of handling HLW and LLW in calcined forms, from waste manipulation, storage and transportation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In Situ High-Temperature TEM Observation of Inconel Corrosion by Molten Chloride Salts with N 2 , O 2 , or H 2 O

Here, in situ transmission electron microscopy (TEM) diffraction and imaging techniques are used to monitor and quantify corrosion of Inconel-625 by pure molten chloride salts (MgCl 2 – NaCl – KCl) at 500 °C–800 °C in 1.0 atm inert N 2 or pure O2, or by salts which are controllably hydrated in a high vacuum chamber. The isothermal corrosion rate R in inert N 2 increases from 203 ± 30 μ m year –1 at 700 °C to 463 ± 30 μ m year –1 at 800 °C. An oxygen ambient causes a six-fold increase to R = 1261 ± 170 μ m year –1 at 700 °C. Salt hydration dramatically accelerates corrosion to R > 3 × 10 5 μ m year –1 at 700 °C while it leads to a more moderate R = 95 ± 20 and 486 ± 30 μ m year –1 at 500 °C and 600 °C, respectively. These isothermal corrosion rates indicate that the molten chloride corrosion is significantly accelerated by salt hydration at temperatures above 600 °C, where corrosion is aggravated by increased generation and solubility of corrosive HCl gases. Hence, to reduce rate of corrosion it is important to both avoid incorporation of H 2 O into the system at each stage and ensure proper flushing of the system before increasing the temperature beyond 600 °C. Compositional analysis of the corroded cells indicate that corrosion in O 2 ambient is dominated by oxidation of metals by O 2 gas dissolved in the chloride melt, but corrosion in H 2 O ambients is caused by chlorination of metals by dissolved HCl gas and MgOH + ions. So, to reduce rate of corrosion, steps should be taken to tailor chloride melt compositions that has low solubility for HCl and O 2 . All of our corroded samples exhibit passive-protective oxide layers of Cr, Mg, and Ni. In addition, distinct volatile compounds of Ni, Mo and Cr involving NiCl 2 , (Na,K) 2 MoO 4 and CrO 2 (OH) 2 are detected in N 2 , H 2 O, and O 2 ambients, respectively. We believe that corrosion acceleration can be minimized by minimizing formation of volatile by-products or promoting reactions that could convert these volatile compounds to solid phases, as these volatile compounds led to destruction of protective oxide layers.

14 SOLAR ENERGY↗