Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONSULTANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Manual No. 17902 LANL-2023 for Lansmont Drop Tester Model PDT 80

This document describes the modifications made to a “Model PDT 80 drop test system” from the Lansmont Corporation (Monterey CA). For serial number (SN: M-17902), Los Alamos National Laboratory staff members changed the system, in consultation with Lansmont technical staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

ENDF-6 Formats Manual - Data Formats and Procedures for the Evaluated Nuclear Data Files ENDF/B-VI, ENDF/B-VII and ENDF/B-VIII

This revision of “ENDF-6 Formats Manual” pertains to version 6 of the ENDF formats. The seventh and eighth versions of the ENDF/B library, namely ENDF/B-VII and ENDF/B VIII, use the ENDF-6 format. The manual is based on the previous version of the document, revised in June 2005, In some cases the older version from October 1991 was consulted in order to resolve some ambiguities and errors that were introduced when the reference document was translated from WordPerfect in Word format.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Late-Stage Research Development and Demonstration Sub-Activities Updates

Oak Ridge National Laboratory (ORNL), in collaboration with the Pacific Northwest National Laboratory (PNNL), the National Renewable Energy Laboratory (NREL), the Lawrence Berkeley National Laboratory (LBNL), and the Hummingbird Firm (a specialized consulting firm focused on promoting diversity, equity, and inclusion considerations), has initiated a national initiative known as the Heat Pump (HP) and Heat Pump Water Heater (HPWH) Field Validation Partnership. This effort involves active participation from numerous critical entities involved in research and market transformation within the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lead-Bismuth Small Modular Reactor (SMR) Licensing Development [Abstract]

The Columbia Basin Consulting Group (CBCG) is developing an advanced reactor cooled by Lead-Bismuth (Pb-Bi). The design is being developed for a high level of passive safety. It has the advantages of the classical liquid metal (sodium) reactor, i.e. small size and passive safety, while having the additional advantage of chemically inert coolant.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Guidance for Integrating Energy Justice and Equity in Building Technology Deployment Programs: Tracking, Reporting, and Maximizing the Flow of Benefits from Building System Technology Deployment Activities to Disadvantaged Communities and Target Sectors

The Federal Justice40 Initiative directs at least 40% of the overall benefits of certain clean energy investments to flow to disadvantaged communities and requires that all federal programs covered by Justice40 consult stakeholders to determine the program benefits, and that the flow of benefits to disadvantaged communities is tracked and reported. Unequal distribution of benefits, in terms of access to clean energy research, design, development, and deployment, can disproportionately benefit or burden certain communities. This can result in higher rates of pollution, negative health effects, and increased energy burdens and insecurities in disadvantaged communities. Programs focused on decarbonizing the built environment can enhance health, quality of life, and economic opportunities for impacted communities. This guidance document, developed by Pacific Northwest National Laboratory and funded by the U.S. Department of Energy’s Building Technologies Office, provides best practices and approaches for incorporating energy justice and equity principles into building technology deployment activities. It provides best practices and recommendations for communicating with and involving disadvantaged communities and target building sectors in program activities, along with methods to monitor and report the distribution of benefits to these sectors. This document lays out a set of strategies, metrics, and best practices that can be implemented over time to apply energy justice and equity approaches, whether the program is just starting out or ongoing. Although this guidance was designed for Building Technologies Office technology deployment programs, the best practices, recommendations, and methods can be valuable to any program concerned with the equitable deployment of clean energy technologies. The goal of this project is to enable the equitable development, deployment, and adoption of clean energy technologies and practices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2.3.3.01- xSDK-Batched Final Report for Subcontract Partner KIT

The xSDK batched effort as focus effort of the ECP project xSDK focused on the development, deployment, and dissemination of batched functionality in the US Exascale Computing Project. Over a duration of almost three years, KIT as subcontract to LLNL provided technology development, functionality deployment, integration support, and consulting on batched iterative solvers and batched preconditioners. This final report accumulates the quarterly progress reports and most significant contributions.

97 MATHEMATICS AND COMPUTING↗

2.3.3.01- xSDK-Multiprecision Final Report for Subcontract Partner KIT

The xSDK Multiprecision effort as focus effort of the ECP project xSDK focused on the development, deployment, and dissemination of mixed precision functionality in the US Exascale Computing Project. Over a duration of four years, KIT as subcontract to LLNL provided technology development, functionality deployment, integration support, and consulting on mixed precision functionality. The subcontract was modified several times over the project duration. All deliverables of the subcontract have been completed. This final report accumulates the quarterly progress reports and most significant contributions.

97 MATHEMATICS AND COMPUTING↗

Center For Actinide Science and Technology (CAST)

CAST encompassed 17 senior researchers in its first funding cycle and added two additional theorists briefly in the final two years. Approximately 37 graduate students and post-doctoral associates were supported by CAST. Within the 19 senior researchers there were changes in composition since the center was first funded. One researcher left associated with a move to another university. Two were phased out because they did not meet the expectations of CAST in terms of research performance. These decisions were always made in consultation with our External Advisory Committee (EAC) and DOE management. In fact, the phasing out of the two PI’s was suggested first by the EAC. Two new researchers were also brought in response to feedback at our midterm review where it was suggested that we needed increased theory support in CAST. No further changes were implemented since then, and CAST researchers thought that stability and optimal productivity was achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

United States Nuclear Data Program Work Plan for FY 24

The work plan described in this document has been developed to cover work to be performed by the U. S. Nuclear Data Program (USNDP) during Fiscal Year (FY) 2024 that begins on October 1, 2022. Previously, 23 work plans have been prepared for the nuclear data program covering FYs 2021-2022. This plan has been prepared in consultation with the members of the Coordinating Committee who represent the organizations participating in the program. Each Coordinating Committee member prepared a draft plan for his/her organization. Each contribution was integrated into a unified work plan. The draft plan was then circulated to the Coordinating Committee for comments and corrections before the final document was submitted to the U.S. Department of Energy (DOE).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

xSDK Multiprecision (Final Report)

The xSDK Multiprecision effort as focus effort of the ECP project xSDK focused on the development, deployment, and dissemination of mixed precision functionality in the US Exascale Computing Project. Over a duration of four years, KIT as subcontract to LLNL provided technology development, functionality deployment, integration support, and consulting on mixed precision functionality. The subcontract was modified several times over the project duration. All deliverables of the subcontract have been completed. This final report accumulates the quarterly progress reports and most significant contributions.

97 MATHEMATICS AND COMPUTING↗

Los Alamos National Laboratory Transit Service Implementation Plan

In 2021, Los Alamos National Laboratory (LANL) partnered with Nelson\Nygaard Consulting Associates to conduct the LANL Transit Options Study in preparation for Laboratory expansion plans. When the study started, LANL was expected to grow by 3,000 employees over the next several years. Most of that growth has already taken place. Sixty percent of employees commute from outside of Los Alamos County, and with limited housing capacity in Los Alamos, most of the new employees are expected to live outside of Los Alamos County as well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Late-Stage Research Development and Demonstration Sub-activities Updates

Oak Ridge National Laboratory (ORNL), in collaboration with the Pacific Northwest National Laboratory (PNNL), the National Renewable Energy Laboratory (NREL), the Lawrence Berkeley National Laboratory (LBNL), and the Hummingbird Firm (a specialized consulting firm focused on promoting diversity, equity, and inclusion considerations), has initiated a national initiative known as the Heat Pump (HP) and Heat Pump Water Heater (HPWH) Field Validation Partnership. This effort involves active participation from numerous critical entities involved in research and market transformation within the field.

99 GENERAL AND MISCELLANEOUS↗

Finding Of Adverse Effect and Proposed Mitigation for the Removal of Joshua Trees at Building 23-210, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) recently removed two fallen Joshua trees that were part of an Accessory Resource (AR) to the former Department of Defense (DOD) Motor Pool Maintenance Compound in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. C307) on the Nevada National Security Site (NNSS) in Nye County, Nevada (Figure 1). The Joshua trees were part of AR3, a landscaped feature at the entrance to the compound. There are two remaining Joshua trees at risk of falling which may require removal in the future. The NNSA/NFO is proactively consulting with the SHPO regarding the potential removal of the remaining two trees. The purpose of the undertaking is to ensure that dead or dying Joshua trees do not cause damage to the remaining landscape elements, nor injury to NNSS employees. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-210 was the DOD’s motor vehicle maintenance compound constructed in 1951. The compound included its own repair shop and fuel station. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992. The former DOD Motor Pool Compound was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). The foundation for Building 23-210 was also identified in Appendix C of the Mercury PA as a Category III contributing element with three contributing ARs. Category III properties are those that may include elements for which there are several representatives in the MHD, such as foundations, and those elements which possess characteristics that are not unique to the MHD and are commonly found in other non-NNSS facilities. The former DOD compound, which is identified by the foundation for the Building 23-210 and its ARs, is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

Clear Sky Toolkit: Decision Support User Guide

The Clear Sky Decision Support Template is a Microsoft Excel-based resource that enables users to screen and prioritize critical facilities for the addition of solar + storage. The Decision Support Template consolidates and streamlines the most relevant resources from the emergency management discipline, the electric utility sector, and national energy research institutions to assist in further site analysis and decision-making. The Decision Support Template is intended for use by local government and private sector decision-makers who aim to mitigate the effects of power outages on critical infrastructure, understand the potential for deploying photovoltaic (PV) and storage solutions on critical facilities, and align emergency management planning processes and utility needs with community resilience objectives. The Decision Support Template is divided into five modules that provide a structured, step-by-step approach users can follow and apply to unique circumstances. This process guides a more thorough and accurate assessment of a site's potential to accommodate a solar + storage system, provide grid benefits to utilities, and support community resilience and disaster mitigation for the broader region. After identifying potentially viable and preferred sites for solar + storage using the Decision Support Template, users should conduct a more detailed evaluation and consultation with a solar professional.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transfer Factors for the FRMAC Assessment Manual and Turbo FRMAC to Improve Radiological Dose Assessment

The Turbo FRMAC analysis tool is used to perform complex calculations to quickly evaluate radiological consequences and aid in decision making during an emergency response by assessing impacts to the public, workers, and the food supply. Turbo FRMAC calculations are based on methods established by the Federal Radiological Monitoring and Assessment Center (FRMAC). To be able to assess impacts, input data called transfer factors that describe radionuclide uptake by local plants and animals are required. During the code application exercises in late 2016, identifying, finding, and validating nonstandard transfer factors proved to be time consuming and diverted the teams’ activity away from other critical tasks. As a result, a task was undertaken to dramatically expand the list of available transfer factors (food and non-food) and incorporate these factors into Turbo FRMAC. This will ultimately result in improved efficiency of the assessment team to perform calculations during times when the FRMAC is activated and provide more defensible, vetted data from which to calculate results. As a result of these and subsequent exercises, transfer factors were needed for the following items: bell peppers, Christmas tree, deer, flowers, fresh cucumbers, tomatoes, grapefruit, lichens, mushrooms, oranges, snap beans, squash, strawberries, sugarcane for sugar and seed, sweet corn, tea, tobacco, tree bark, and watermelon. To expand the applicability of the information tables, generic transfer data were also provided for common categories and recommendations were made for expanding the list of chemicals based on chemical similarity. The data presented in this report were compiled from recent literature with most of the data encompassing the period from 2000 to 2018. The following radionuclides were targeted during the literature search: elements associated with reactor accidents or nuclear detonations (Sr 89/90, Cs 134/137, Ce 141/144, Ru 103/106, I 129/131/133, Pu 238/239, Am 241, Zr 95, and Nb 95) and elements associated with industrial accidents or dirty bombs (Ir 192 and Co 60). Data from other elements were evaluated if they were identified during the literature search. In addition, reports were evaluated that were recommended by the research consultants. For each plant or animal transfer factor, the goal was to determine the geometric mean, the geometric standard deviation, the minimum, the maximum, and the number of measurements used. If only one measurement was available that was presented as the mean. Concentration ratios with large geometric standard deviations (GSDs) were generally the result of a paucity of measurements or a few disparate measurements. Measurement disparity was observed for data from different soil types. The geometric mean (GM) is a good reference value for planning and responses purposes, but the location-specific concentrations are unlikely to be similar to the model results. Recommendations for further work include: segregating the data to reflect the influence of soil type, developing approaches to incorporate animal data based on aggregated transfer measurements, and including data for foliar deposition on plants.

61 RADIATION PROTECTION AND DOSIMETRY↗

Late-Stage Research Development and Demonstration Sub-activities Updates – FY24 Q3

Oak Ridge National Laboratory (ORNL), in collaboration with the Pacific Northwest National Laboratory (PNNL), the National Renewable Energy Laboratory (NREL), the Lawrence Berkeley National Laboratory (LBNL), and the Hummingbird Firm (a specialized consulting firm focused on promoting diversity, equity, and inclusion considerations), has initiated a national initiative known as the Heat Pump (HP) and Heat Pump Water Heater (HPWH) Field Validation Partnership. This effort involves active participation from numerous critical entities involved in research and market transformation within the field. The ORNL team is responsible for leading Late-Stage Research Development and Demonstration (LSRDD) among the four different topics. The overall outcomes of this project will be: (1) A structured Field Validation Partnership between DOE, the national labs, research, implementation, and market transformation organizations. This will result in unique way to coordinate field validation plans and collect relevant data from around the country into the HP and HPWH Field Validation Database. (2) The Field Validation Partnership will result in a continuous stream of information between DOE and the major industry players in the space of HPs and HPWHs. If desired, DOE could use this information to inform roadmaps related to HP and HPWH market adoption and research going forward. (3) The structure of this Partnership provides a mechanism for sharing lessons learned directly between Late-Stage RD&D, Building Integration Barriers, Regional Market and Policy and Workforce Development efforts. The result will be training content that is well-reviewed by the Partnership which will lead to a workforce that meets the industry’s quality and workforce supply demands. (4) The structure of this Partnership also provides an opportunity for regions to share lessons learned on policy and market transformation with each other through the Market and Policy core Committee. This report includes an update in Late-Stage Research Development and Demonstration.

99 GENERAL AND MISCELLANEOUS↗

Community Planning for Solar: Conducting a Community Solar Survey

This guide is designed to assist community officials, volunteers, and regional planning agency staff in conducting a survey of residents to learn about attitudes and development preferences towards solar energy within the community. The guide will provide the key steps, timelines, distribution options, ethics, and considerations that should be made in developing a survey distribution strategy. The guide also contains an overview of various question types and response categories, with considerations for the type of data that are needed for the study. The guide concludes with recommendations for managing data and databases, data visualization, and reporting results. The appendix includes samples of materials used in a solar energy survey, from invitation letters to the survey. This document is intended to provide a practical guide for implementing a survey in communities that are proactively planning for solar development. The guide offers a practical “how-to” plan for conducting a survey. It may be advantageous to consult with an expert in survey development who will be familiar with any methods and techniques described in this guide, but this is not necessary. This guide offers basic considerations and examples of questions and analyses to help a community understand preferences of the community.

14 SOLAR ENERGY↗