Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONNECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Vibration-resistant PC board feedthrough

New fabrication method uses annealed-nickel ribbon loop to interface coaxial input (or output) connector to printed-wiring board. Inexpensive ribbon interface cuts vibration-induced failure between coaxial cable and printed-wiring board.

Mandel, H.↗

Low-inductance bus lines

Laminated bus strips and bifilar litz cable connectors for high-power rectifiers, thrisistors, and transistors provide low inductance and eliminate electromagnetic interference in high-power circuits. These techniques offer significant cost advantages because of ease of assembly and consistent high quality of product. Effectiveness makes general usage in static power conversion likely.

Kernick, A.↗

Potential biomedical applications of ion beam technology

Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic pros-thesis fixtion, and dental implants.

Banks, B. A.↗

Long life testing of spare Mariner Venus '67 hardware

The faultless performance of the Mariner Venus '67 Power Conditioning Electronics (PCE) throughout six years of continuous operation in a simulated space environment is reported. Weekly functional tests supplemented by daily monitoring verified that the PCE equipment can perform to its intended functions for at least six years without apparent performance degradation. Performance throughout the test period was very stable, there are no circuit or redundancy improvements to be considered. When the equipment was examined after the test was completed, there was no evidence of any physical damage nor any difficulty in disconnecting the wiring connectors.

Silverman, S. W.↗

Orbiter CCTV video signal noise analysis

The amount of steady state and transient noise which will couple to orbiter CCTV video signal wiring is predicted. The primary emphasis is on the interim system, however, some predictions are made concerning the operational system wiring in the cabin area. Noise sources considered are RF fields from on board transmitters, precipitation static, induced lightning currents, and induced noise from adjacent wiring. The most significant source is noise coupled to video circuits from associated circuits in common connectors. Video signal crosstalk is the primary cause of steady state interference, and mechanically switched control functions cause the largest induced transients.

Lawton, R. M.↗

Engineering study of the module/array interface for large terrestrial photovoltaic arrays

Three major areas--structural, electrical, and maintenance--were evaluated. Efforts in the structural area included establishing acceptance criteria for materials and members, determining loading criteria, and analyzing glass modules in various framing system configurations. Array support structure design was addressed briefly. Electrical considerations included evaluation of module characteristics, intermodule connectors, array wiring, converters and lightning protection. Plant maintenance features such as array cleaning, failure detection, and module installation and replacement were addressed.

Source record↗

Solar cell shingle

A solar cell shingle was made of an array of solar cells on a lower portion of a substantially rectangular shingle substrate made of fiberglass cloth or the like. The solar cells may be encapsulated in flourinated ethylene propylene or some other weatherproof translucent or transparent encapsulant to form a combined electrical module and a roof shingle. The interconnected solar cells were connected to connectors at the edge of the substrate through a connection to a common electrical bus or busses. An overlap area was arranged to receive the overlap of a cooperating similar shingle so that the cell portion of the cooperating shingle may overlie the overlap area of the roof shingle. Accordingly, the same shingle serves the double function of an ordinary roof shingle which may be applied in the usual way and an array of cooperating solar cells from which electrical energy may be collected.

Forestieri, A. F.↗

Programmable data communications controller requirements

The design requirements for a Programmable Data Communications Controller (PDCC) that reduces the difficulties in attaching data terminal equipment to a computer are presented. The PDCC is an interface between the computer I/O channel and the bit serial communication lines. Each communication line is supported by a communication port that handles all line control functions and performs most terminal control functions. The port is fabricated on a printed circuit board that plugs into a card chassis, mating with a connector that is joined to all other card stations by a data bus. Ports are individually programmable; each includes a microprocessor, a programmable read-only memory for instruction storage, and a random access memory for data storage.

Source record↗

Potential biomedical applications of ion beam technology

Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic prosthesis fixation, and dental implants.

Banks, B. A.↗

Laser fiber optics ordnance initiation system

Recent progress on system development in the laser initiation of explosive devices is summarized. The topics included are: development of compact free-running mode and Q-switched lasers, development of low-loss fiber optic bundles and connectors, study of nuclear radiation effects on the system, characterization of laser initiation sensitivities of insensitive high explosives, and the design methods used to achieve attractive system weight and cost savings. Direction for future work is discussed.

Yang, L. C.↗

Automatic circuit interrupter

In technique, voice circuits connecting crew's cabin to launch station through umbilical connector disconnect automatically unused, or deadened portion of circuits immediately after vehicle is launched, eliminating possibility that unused wiring interferes with voice communications inside vehicle or need for manual cutoff switch and its associated wiring. Technique is applied to other types of electrical actuation circuits, also launch of mapped vehicles, such as balloons, submarines, test sleds, and test chambers-all requiring assistance of ground crew.

Dwinell, W. S.↗

Easily-wired toggle switch

Crimp-type connectors reduce assembly and disassembly time. With design, no switch preparation is necessary and socket contracts are crimped to wires inserted in module attached to back of toggle switch engaging pins inside module to make electrical connections. Wires are easily removed with standard detachment tool. Design can accommodate wires of any gage and as many terminals can be placed on switch as wire gage and switch dimensions will allow.

Dean, W. T.↗

Vacuum leadthrough for hydrogen maser

Nonmagnetic leadthroughs are used in hydrogen maser for electrical interconnection into vacuum chamber. Seal uses uranium glass to form vacuum seal to tungsten rod. Epoxy resin seals glass-coated rod to aluminum body. Connector was subjected to temperature cycling between minus 65 degrees to 150 C, six to seven times over a sixteen hour period.

Norris, D. A.↗

Miniature thermocouple disconnect

Commercially available subminiature connector modified for utilization with both flexible and small diameter metal-sheathed thermocouples results in reliable thermocouple for instrumentation on wind-tunnel models smaller than commercial disconnects normally used.

Quinn, K. L.↗

Standard high-reliability integrated circuit logic packaging

A family of standard, high-reliability hardware used for packaging digital integrated circuits is described. The design transition from early prototypes to production hardware is covered and future plans are discussed. Interconnections techniques are described as well as connectors and related hardware available at both the microcircuit packaging and main-frame level. General applications information is also provided.

Slaughter, D. W.↗

Effect of surface texture by ion beam sputtering on implant biocompatibility and soft tissue attachment

The objectives in this report were to use the ion beam sputtering technique to produce surface textures on polymers, metals, and ceramics. The morphology of the texture was altered by varying both the width and depth of the square pits which were formed by ion beam erosion. The width of the ribs separating the pits were defined by the mask used to produce the texture. The area of the surface containing pits varies as the width was changed. The biological parameters used to evaluate the biological response to the texture were: (1) fibrous capsule and inflammatory response in subcutaneous soft tissue; (2) strength of the mechanical attachment of the textured surface by the soft tissue; and (3) morphology of the epidermal layer interfacing the textured surface of percutaneous connectors. Because the sputter yield on teflon ribs was approximately an order of magnitude larger than any other material the majority of the measurements presented in the report were obtained with teflon.

Gibbons, D. F.↗

Stand-alone development system using a KIM-1 microcomputer module

A small microprocessor-based system designed to: contain all or most of the interface hardware, designed to be easy to access and modify the hardware, to be capable of being strapped to the seat of a small general aviation aircraft, and to be independent of the aircraft power system is described. The system is used to develop a low cost Loran C sensor processor, but is designed such that the Loran interface boards may be removed and other hardware interfaces inserted into the same connectors. This flexibility is achieved through memory-mapping techniques into the microprocessor.

Nickum, J. D.↗

Test report for twinax cable (Rockwell type MB0150-051)

A controlled impedance twisted pair shielded cable was tested to determine the frequency response and effects of mismatched termination. It was found that a long length of this cable, about 100 feet, exhibited a frequency sensitive attenuation roll-off greater than 1.5 db down at 5 MHz. It was also determined that improper termination resulted in losses of 1/2 to 1 db within the frequency range of 200 KHz to greater than 1-1/2 MHz. The test results indicate a possible problem where mismatched connectors are used in video signal cables.

Doland, G. D.↗