Empirical Analysis of the Subjective Impressions and Objective Measures of Domain Scientists’ Visual Analytic Judgments

Scientists often use specific data analysis and presentation methods familiar within their domain. But does high familiarity drive better analytical judgment? This question is especially relevant when familiar methods themselves can have shortcomings: many visualizations used conventionally for scientific data analysis and presentation do not follow established best practices. This necessitates new methods that might be unfamiliar yet prove to be more effective. But there is little empirical understanding of the relationships between scientists’ subjective impressions about familiar and unfamiliar visualizations and objective measures of their visual analytic judgments. To address this gap and to study these factors, we focus on visualizations used for comparison of climate model performance. We report on a comprehensive survey-based user study with 47 climate scientists and present an analysis of : i) relationships among scientists’ familiarity, their perceived lev- els of comfort, confidence, accuracy, and objective measures of accuracy, and ii) relationships among domain experience, visualization familiarity, and post-study preference.

Dasgupta, Aritra↗

Long term occupancy estimation in a commercial space: an empirical study: poster abstract

Understanding occupancy patterns in a building is very useful to control HVAC systems for improving energy efficiency of the building and occupant comfort. There has been a very little attempt to understand long term occupancy patterns in a commercial space. In this work, we leverage depth sensors (Kinect for XBOX One) to collect occupancy count from an 11,000 square foot commercial space (Bosch office) for nine months. We analyze the collected data and describe key findings that provide deep insights about how a commercial space is used and serve as a guideline to formulate novel and efficient control strategies.

Liu, Kin Sum↗

A Data Driven Pre-cooling Framework for Energy Cost Optimization in Commercial Buildings

Commercial buildings consume significant amount of energy. Facility managers are increasingly grappling with the problem of reducing their buildings’ peak power, overall energy consumption and energy bills. In this paper, we first develop an optimization framework – based on a gray box model for zone thermal dynamics – to determine a pre-cooling strategy that simultaneously shifts the peak power to low energy tariff regimes, and reduces both the peak power and overall energy consumption by exploiting the flexibility in a building’s thermal comfort range. We then evaluate the efficacy of the pre-cooling optimization framework by applying it to building management system data, spanning several days, obtained from a large commercial building located in a tropical region of the world. The results from simulations show that optimal pre-cooling reduces peak power by over 50%, energy consumption by up to 30% and energy bills by up to 37%. Next, to enable ease of use of our framework, we also propose a shortest path based heuristic algorithmfor solving the optimization problemand show that it has comparable erformance with the optimal solution. Finally, we describe an application of the proposed optimization framework for developing countries to reduce the dependency on expensive fossil fuels, which are often used as a source for energy backup.We conclude by highlighting our real world deployment of the optimal pre-cooling framework via a software service on the cloud platform of a major provider. Our pre-cooling methodology, based on the gray box optimization framework, incurs no capital expense and relies on data readily available from a building management system, thus enabling facility managers to take informed decisions for improving the energy and cost footprints of their buildings

Vishwanath, Arun↗

DReAM: Demand Response Architecture for Multi-level District Heating and Cooling Networks

In this paper, we exploit the inherent hierarchy of heat exchangers in District Heating and Cooling (DHC) networks and propose DReAM, a novel Demand Response (DR) architecture for Multi-level DHC networks. DReAM serves to economize system operation while still respecting comfort requirements of individual consumers. Contrary to many present day DR schemes that work on a consumer level granularity, DReAM works at a level of hierarchy above buildings, i.e. substations that supply heat to a group of buildings. This improves the overall DR scalability and reduce the computational complexity. In the first step of the proposed approach, mathematical models of individual substations and their downstream networks are abstracted into appropriately constructed low-complexity structural forms. In the second step, this abstracted information is employed by the utility to perform DR optimization that determines the optimal heat inflow to individual substations rather than buildings, in order to achieve the targeted objectives across the network. We validate the proposed DReAM framework through experimental results under different scenarios on a test network.

Bhattacharya, Saptarshi↗

Beyond Control: Enabling Smart Thermostats for Leakage Detection

Smart thermostats, with multiple sensory abilities, are becoming pervasive and ubiquitous, in both residential and commercial buildings. By analyzing occupants’ behavior, adjusting set temperature automatically, and adapting to temporal and spatial changes in the atmosphere, smart thermostats can maximize both - energy savings and user comfort. In this paper, we study smart thermostats for refrigerant leakage detection. Retail outlets, such as milk-booths and quick service restaurants set up cold-rooms to store perishable items. In each room, a refrigeration unit (akin to air-conditioners) is used to maintain a suitable temperature for the stored products. Often, refrigerant leaks through the coils (or valves) of the refrigeration unit which slowly diminishes the cooling capacity of the refrigeration unit while allowing it to be functional. Such leaks waste significant energy, risk occupants’ health, and impact the quality of stored perishable products. While store managers usually fail to sense the early symptoms of such leaks, current techniques to report refrigerant leakage are often not scalable. We propose Greina - to continuously monitor the readily available ambient information from the thermostat and timely report such leaks. We evaluate our approach on 74 outlets of a retail enterprise and results indicate that Greina can report the leakage a week in advance when compared to manual reporting

Jain, Milan↗

Gnu-RL: A Precocial Reinforcement Learning Solution for Building HVAC Control Using a Differentiable MPC Policy

Reinforcement learning (RL) was first demonstrated to be a feasible approach to controlling heating, ventilation, and air conditioning (HVAC) systems more than a decade ago. However, there has been limited progress towards a practical and scalable RL solution for HVAC control. While one can train an RL agent in simulation, it is not cost-effective to create a model for each thermal zone or building. Likewise, existing RL agents generally take a long time to learn and are opaque to expert interrogation, making them unattractive for real-world deployment. To tackle these challenges, we propose Gnu-RL: a novel approach that enables practical deployment of RL for HVAC control and re- quires no prior information other than historical data from exist- ing HVAC controllers. To achieve this, Gnu-RL adopts a recently- developed Differentiable Model Predictive Control (MPC) policy, which encodes domain knowledge on planning and system dynam- ics, making it both sample-efficient and interpretable. Prior to any interaction with the environment, a Gnu-RL agent is pre-trained on historical data using imitation learning, which enables it to match the behavior of the existing controller. Once it is put in charge of controlling the environment, the agent continues to improve its policy end-to-end, using a policy gradient algorithm. We evaluate Gnu-RL on both an EnergyPlus model and a real- world testbed. In both experiments, our agents were directly de- ployed in the environment after offline pre-training on expert demonstration. In the simulation experiment, our approach saved 6.6% energy compared to the best published RL result for the same environment, while maintaining a higher level of occupant comfort. Next, Gnu-RL was deployed to control the HVAC of a real-world conference room for a three-week period. Our results show that Gnu-RL saved 16.7% of cooling demand compared to the existing controller and tracked temperature set-point better.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electricity Pricing aware Deep Reinforcement Learning based Intelligent HVAC Control

Recently, deep reinforcement learning (DRL) based intelligent control of Heating, Ventilation, and Air Conditioning (HVAC) has gained a lot of attention due to DRL's ability to optimally control HVAC for minimizing operational cost while maintaining resident's comfort. The success of such DRL-based techniques largely depends on the articulation of the problem in terms of states, actions, and reward function. Inclusion of the electricity pricing information in the problem formulation can play an important role in saving the cost of HVAC operation. However, less attention has been given in the literature on formulating well-crafted state features based on electricity pricing. In this work, we propose an approach for training the DRL model with a specific focus on feature engineering based on electricity pricing. During training, we generate random but sufficiently realistic electricity price signals so that the pre-trained DRL model is robust and adaptive to the dynamic and variable electricity prices. The validation results are encouraging and show the potential of ≈12%-15% savings in the one day cost of HVAC operation, proving the usefulness of including electricity pricing related features as state features.

Kurte, Kuldeep↗

Learning-based framework for sensor fault-tolerant building HVAC control with model-assisted learning

As people spend up to 87% of their time indoors, intelligent Heating, Ventilation, and Air Conditioning (HVAC) systems in buildings are essential for maintaining occupant comfort and reducing energy consumption. These HVAC systems in smart buildings rely 'on real-time sensor readings, which in practice often suffer from various faults and could also be vulnerable to malicious attacks. Such faulty sensor inputs may lead to the violation of indoor environment requirements (e.g., temperature, humidity, etc.) and the increase of energy consumption. While many model-based approaches have been proposed in the literature for building HVAC control, it is costly to develop accurate physical models for ensuring their performance and even more challenging to address the impact of sensor faults. In this work, we present a novel learning-based framework for sensor fault-tolerant HVAC control, which includes three deep learning based components for 1) generating temperature proposals with the consideration of possible sensor faults, 2) selecting one of the proposals based on the assessment of their accuracy, and 3) applying reinforcement learning with the selected temperature proposal. Moreover, to address the challenge of training data insufficiency in building-related tasks, we propose a model-assisted learning method leveraging an abstract model of building physical dynamics. Through extensive experiments, we demonstrate that the proposed fault-tolerant HVAC control framework can significantly reduce building temperature violations under a variety of sensor fault patterns while maintaining energy efficiency.

Xu, Shichao↗

Ontologies at Work: Analyzing Information Requirements for Model Predictive Control in Buildings

Model Predictive Control (MPC) has shown significant potential for improving energy efficiency, indoor air quality and occupant comfort of buildings. MPC-based control algorithms have also shown the ability to shift loads and optimize for multiple objectives, including but not limited to reducing the green-house gas emissions, energy costs and peak demand. However, one of the main implementation challenges of these control algorithms is the integration and configuration effort needed to deploy a supervisory MPC controller in a building. By assigning standardized references to information sources and control points in buildings, existing studies have shown that semantic ontologies and corresponding queries have the potential to ease the deployment of such controllers. Yet, the use of semantic information to ease the deployment processes of MPC controllers is still limited. In this paper, we review three MPC experiments and synthesize the information requirements of these optimization problems. We then turn to existing and upcoming semantic ontologies such as Brick, SAREF and ASHRAE Standard 223 to represent these requirements, evaluating their potential to support the implementation of an MPC controller. This investigation concludes with a discussion of existing opportunities and open questions that the community should explore to support more streamlined MPC implementations.

Prakash, Anand Krishnan↗

Existence of a Nonzero Worst‐Case ACH for Short‐Term Exposure in Ventilated Indoor Spaces

A well‐ventilated room is essential to reduce the risk of airborne transmission. As such, the scientific community sets minimum limits on ventilation with the idea that increased ventilation reduces pathogen concentration and thus reduces the risk of transmission. In contrast, the upper limit on ventilation is usually determined by human comfort and the need to reduce energy consumption. While average pathogen concentration decreases with increased ventilation, local concentration depends on multiple factors and may not follow the same trend, especially within short exposure times over large separation distances. Here, we show through experiments and high‐fidelity simulations the existence of a worst‐case ventilation where local pathogen concentration increases near the receiving host. This occurs during the type of meetings that were recommended during the pandemic (and in some cases solely authorized) with reduced occupancy adhering to social distancing and short exposure times below 20 minutes. We maintain that for cases of high occupancy and long exposure time, increased ventilation remains necessary.

Construction & Building Technology↗

Building Energy Management Open Source Software

This is the repository for Building Energy Management Open Source Software (BEMOSS), which is an open source operating system that is engineered to improve sensing and control of equipment in small- and medium-sized commercial buildings. BEMOSS offers the following key features: (1) Open source, open architecture – BEMOSS is an open source operating system that is built upon VOLTTRON – a distributed agent platform developed by Pacific Northwest National Laboratory (PNNL). BEMOSS was designed to make it easy for hardware manufacturers to seamlessly interface their devices with BEMOSS. Software developers can also contribute to adding additional BEMOSS functionalities and applications. (2) Plug & play – BEMOSS was designed to automatically discover supported load controllers (including smart thermostats, VAV/RTUs, lighting load controllers and plug load controllers) in commercial buildings. (3) Interoperability – BEMOSS was designed to work with load control devices form different manufacturers that operate on different communication technologies and data exchange protocols. (4) Cost effectiveness – Implementation of BEMOSS deemed to be cost-effective as it was built upon a robust open source platform that can operate on a low-cost single-board computer, such as Odroid. This feature could contribute to its rapid deployment in small- or medium-sized commercial buildings. (5) Scalability and ease of deployment – With its multi-node architecture, BEMOSS provides a distributed architecture where load controllers in a multi-floor and high occupancy building could be monitored and controlled by multiple single-board computers hosting BEMOSS. This makes it possible for a building engineer to deploy BEMOSS in one zone of a building, be comfortable with its operation, and later on expand the deployment to the entire building to make it more energy efficient. (6) Ability to provide local and remote monitoring – BEMOSS provides both local and remote monitoring ability with role-based access control. (7) Security – In addition to built-in security features provided by VOLTTRON, BEMOSS provides enhanced security features, including BEMOSS discovery approval process, encrypted core-to-node communication, thermostat anti-tampering feature and many more. (8) Support from the Advisory Committee – BEMOSS was developed in consultation with an advisory committee from the beginning of the project. BEMOSS advisory committee comprises representatives from 22 organizations from government and industry.

Source record↗

Retro-Commissioning Sensor Suitcase

This software package is the Graphic User Interface (GUI) software component for the Sensor Suitcase Retro-Commissioning project, which is a sensor and analysis system to support monitoring-based retro-commissioning of small commercial buildings, performed by non-experts. Small commercial buildings typically do not have the budgets or business economics to allow investing in energy efficiency enhancements the building retro-commissioning provides. In addition, they do not have in-house staff with expertise in building systems who can perform building retro-commissioning or identify energy efficiency improvement opportunities. The solution to this problem is to develop a turn-key hardware/software solution (the RCx Sensor Suitcase) that can be used by non-experts to automatically generate low and no-cost energy efficiency rec commendations that will improve building operating costs, occupant comfort and building energy performance. This is a joint project between Lawrence Berkeley National Laboratory, leading the development of the software and analysis elements, and Pacific Northwest National Laboratory (PNNL), leading the development of the hardware and sensor elements with an associated table-based configuration support tool. The project is funded by the U.S. Department of Energy. This software package was developed as a proof-of-concept prototype for the sensor suitcase software component. The software component was developed with a Microsoft Excel spreadsheet which reads the sensor data and calls a MATLAB DLL to analyze the sensor data.

Lin, Guanjing↗

EnergyPlus Version 7

EnergyPlus is a whole building energy simulation program that engineers, architects and researchers use to model energy and water use in buildings. Modeling the performance of a building with EnergyPlus enables building professionals to optimize the building design to use less energy and water. Each version of EnergyPlus is tested extensively before release. EnergyPlus models heating, cooling, lighting, ventilation, other energy flows, and water use. EnergyPlus includes many innovation simulation capabilities: time-steps less than an hour, modular systems and plant integrated with heat balance-based zone simulation, multizone air flow, thermal comfort, water use, natural ventilation, and photovoltaic systems. EnergyPlus runs on the Windows, Macintosh, and Linux platforms. Free add-ons and other third party software products are available for use with EnergyPlus.

Wetter, Michael↗

Predictive Control of Residential Heat Pump Water Heaters [SWR-13-35]

Heat pump water heaters (HPWH) in the United States typically feature both a heat pump and at least one electric resistance element for heating. The heat pump is much more efficient than the element but cannot heat the water as quickly. The combination of these two heat sources makes HPWH a perfect candidate for implementing advanced control algorithms to achieve additional energy savings. NREL's Predictive Control of Residential Heat Pump Water Heaters introduces a novel predictive control method that provides optimal setpoint profile for both heat sources based on the patterns discovered from users' hot water use data. A simulation study indicates the Predictive Control of Residential Heat Pump Water Heaters is able to achieve significant energy savings without impacting users' thermal comfort.

Christensen, Dane↗

foresee™ (SWR-17-15)

foresee™ is a home energy management system (HEMS) that provides a user centric energy automation solution for residential building occupants. Built upon advanced control and machine learning algorithms, foresee™ intelligently manages the home appliances and distributed energy resources (DERs) such as photovoltaics and battery storage in a home. Unlike existing HEMS in the market, foresee™ provides a tailored home automation solution for individual occupants by learning and adapting to their preferences on cost, comfort, convenience and carbon. foresee™ improves not only the energy efficiency of the home but also its capability to provide grid services such as demand response. Highly reliable demand response services are likely to be incentivized by utility companies, making foresee™ economically viable for most homes.

Source record↗

Targeted Energy Management System Toolset

TEMST integrates advanced sensor systems with advanced computational intelligence, e.g. neural networks and fuzzy arithmetic, to enable effective energy management while minimizing negative human comfort consequences and promoting improved occupant satisfaction. Preliminary work suggests that energy cost reductions above ten percent are easily achievable. In addition to optimizing existing Energy Management Systems (EMS), the proposed toolset will be both resilient and secure in order to proactively maintain a safe level of operational normalcy in response to anomalies and malicious actions.

Rieger, CraigG.↗

Co-simulation Framework for Community-scale Building-grid Integration [SWR-21-75]

Distributed energy resources (DERs), including rooftop solar, energy storage, and flexible loads, are gaining popularity as costs decline and as building owners and utilities realize their benefits. DERs can improve distribution system efficiency, help prevent the need for expensive grid upgrades, and increase the resilience of local communities. However, they can also cause difficulties in grid operations and can require controls to achieve their benefits. To address this challenge, NREL researchers have developed a community-scale solution that assesses the impacts of DERs and their control strategies on a distribution system. The framework has been shown to reduce solar photovoltaic (PV) curtailment to 0%, mitigate the adverse impact of solar variability on the distribution voltage, and provide up to 5-day critical load support during emergency events. Utilizing 5 different modules representing the feeder, buildings, home energy management systems, an aggregator, and a utility controller, NREL expects this simulation technology to play a critical role in the continued integration of DERs. According to the Energy Information Administration (EIA), solar curtailments accounted for 94% of the total energy curtailed in the California Independent System Operator (CAISO) in 2020. By enabling Independent System Operators (ISOs) and utility operators to bring solar curtailments to 0%, the electrical grid can become less dependent on fossil-fueled power generation sources. NREL's co-simulation framework contains five major components: Distribution Feeder Model: describes the distribution feeder topology using OpenDSS, including the locations of all DERs. Residential Building Model: simulates a large number of buildings at a high resolution using OCHRETM. The model is equipped to control equipment based on signals from an external module. The model includes major household appliances such as HVAC and a water heater, non-dispatchable load models, a distributed PV system, and a home battery system. Home Energy Management System: optimizes the controls for the devices in a home using foreseeTM. The control can adjust based on the user preferences including cost, comfort, and convenience. In hierarchical control scenarios, where the houses follow signals from an aggregator, the home energy management system provides a flexibility band with a range of power and follows the dispatch signals received from aggregator. Community-Level Aggregator: solves for optimal energy dispatch based on the flexibility bands received from each home and the grid service signal received from the utility controller. Utility-Level Controller: provides grid signals for voltage control using Distributed Energy Resources (DERs), such as solar systems, in the community.

Balamurugan, Sivasathya Pradha↗