Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CESIUM ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

862 records · Page 48

Analytical Results from Routine DSSHT and SEHT Monthly Samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 8B have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal for times when monosodium titanate (MST) is used. Even with no MST strike being performed there exists some small Pu and Sr removal, likely from filtration of fines containing these elements. The Cs removal continues to be excellent, with decontamination factors (DF) averaging 16,400. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior. SRNL recommends that a sample of the strip feed be analyzed for cation and anion content if a further decline in boron concentration is noted in future SEHT samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TH-A-204-01: Part I - Key Data for Ionizing-Radiation Dosimetry

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

TH-A-204-02: Part II - Worldwide Radiation Metrology

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

Enhanced prediction of Cs removal by CST from Hanford tank waste with K accountability

Abstract The treatment of Hanford tank waste is one of the most challenging environmental cleanup activities to date. To expedite the processing of liquid waste stored in underground tanks in Washington State it is necessary to remove the significant dose contributor, 137 Cs. Crystalline silicotitanate ion exchanger is currently used to remove 137 Cs from the aqueous phase of Hanford tank wastes in preparation for vitrification at the Waste Treatment and Immobilization Plant (WTP). Improving the understanding of potassium impacts on ion exchange behavior of Cs will help in the operation of a critical component of one of the most complex treatment processes in the world today. Optimization of this process can result in significant cost savings and less waste production. Toward this effort, a series of batch contact tests varied in potassium concentration were conducted to look at the impact of potassium concentration on Cs distribution. Experimental distribution ratios ( K d ) were compared to the distribution ratios predicted using the ZAM model. A significant underprediction of Cs capacity in the presence of potassium was seen with the existing model. A revision of the equilibrium constants was determined and provided a statistically better fit for determining the Cs K d values in tank waste matrices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Porosity, swelling, and composition evolution in high-burnup monolithic U-Mo fuel

The microstructural progression of very high-burnup (>8 × 10 21 fissions/cm 3 ) monolithic uranium-molybdenum (U-10wt.%Mo) was analyzed, providing crucial insights into the behavior of post-recrystallized nuclear fuel, where scant data exists. Three focused ion beam cuboids sourced from a fuel plate with varying local burnups of 8.86 × 10 21 , 9.05 × 10 21 , and 9.36 × 10 21 fissions/cm 3 were characterized. The porosity and composition of the samples were evaluated to characterize the evolution of the microstructure as a function of fission density and different locations on the fuel plate, while simultaneously isolating plate-specific parameters such as Zr diffusion barrier thickness, hot-isostatic-pressing conditions, enrichment, and reactor conditions. The porosity was segmented, and the three-dimensional distribution of the porosity was extrapolated from the two-dimensional segmentation. The composition was assessed and quantified using energy-dispersive X-ray spectroscopy areal mapping. The porosity fraction increased as a function of the burnup from 27.77±0.51, 35.12±1.54, and 37.71±0.44 % for 8.86 × 10 21 , 9.05 × 10 21 , and 9.36 × 10 21 fissions/cm 3 , respectively. When compared to literature, the porosity volume fraction plateaus at burnups greater than 6 × 10 21 fissions/cm 3 , while the pore size grows linearly as a function of fission density. The number of large pores increased in number density as a function of burnup, while the smallest pores (<0.3 µm) increased up to 9.05 × 10 21 fissions/cm 3 , followed by a decrease at 9.36 × 10 21 fissions/cm 3 . The delamination and cracking in the fuel plate propagated through an interconnected porosity sublayer identified ∼5 µm from the diffusion barrier. The local swelling of the specimens was within or near the prediction bounds of the Robinson-Williams model for local swelling. The fission products, strontium, barium, cerium, and cesium, precipitated into the pores, while neodymium accumulated adjacent to the pores. Furthermore, these findings have direct implications for the development of fuel performance codes and the accurate documentation of the microstructure evolution in high burnup U-Mo, thus enhancing the safety and efficiency of nuclear fuel usage.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Soft-hard acid-base interactions: probing coordination preferences of sulfur an selenium in mixed chalcophosphates in the family APbPS{sub 4-x}Se{sub x} (A = K, Rb, cs; x = 0-4).

The synthesis and structures of the three new compounds, KPbPS{sub 1.84}Se{sub 2.16} (1), RbPbPS{sub 1.56}Se{sub 2.43} (2), and CsPbPS{sub 3.46}Se{sub 0.54} (3), are reported. The solid state structures of 1-3 consist of two-dimensional layers of [PbP(S/Se){sub 4}] separated by alkali metal ions. The structure of 1 was solved in the orthorhombic space group Pna2{sub 1}. Compounds 2 and 3 possess the CsSmGeS{sub 4} structure type, crystallizing in the orthorhombic space group P2{sub 1}2{sub 1}2{sub 1}. All compounds were refined as racemic twins. All chalcogen sites around the tetrahedrally coordinated P atoms show mixed S/Se occupancy; however, there is a preference for Se binding to Pb ions and S binding to alkali ions. A {sup 31}P magic angle spinning NMR study on 1 suggests that, in mixed seleno-/thiophosphates, all of the anions [PS{sub x}Se{sub 4-x}]{sup 3-} (x = 0, 1, 2, 3, 4) are present. The different amount of sulfur and selenium present in KPbPS{sub 1.84}Se{sub 2.16} (1), RbPbPS{sub 1.56}Se{sub 2.43} (2), and CsPbPS{sub 3.46}Se{sub 0.54} (3) is reflected in the solid state absorption spectra from which bandgaps of 2.2 eV were determined for 1 and 2, and a blue-shift to 2.5 eV was observed because of the higher sulfur-content in 3. Thermogravimetric analysis experiments indicated that, upon heating, compound 1 decomposes forming PbSe and sulfur together with other unidentified products. A Raman spectrum of compound 1 showed more bands than are usually observed in seleno- or thiophosphate salts and is another indicator of the mixed seleno-/thiophosphate anions found in 1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling the Hydrogeochemical Transport of Radionuclides through Engineered Barriers System in the Proposed LLW Disposal Site of Taiwan - 12082

A proposed site for final disposal of low-level radioactive waste located in Daren Township of Taitung County along the southeastern coast has been on the selected list in Taiwan. The geology of the Daren site consists of argillite and meta-sedimentary rocks. A mined cavern design with a tunnel system of 500 m below the surface is proposed. Concrete is used as the main confinement material for the engineered barrier. To investigate the hydrogeochemical transport of radionuclides through engineered barriers system, HYDROGEOCHEM5.0 model was applied to simulate the complex chemical interactions among radionuclides, the cement minerals of the concrete, groundwater flow, and transport in the proposed site. The simulation results showed that the engineered barriers system with the side ditch efficiently drained the ground water and lowered the concentration of the concrete degradation induced species (e.g., hydrogen ion, sulfate, and chloride). The velocity of groundwater observed at side ditch gradually decreased with time due to the fouling of pore space by the mineral formation of ettringite and thaumasite. The short half-life of Co-60, Sr-90 and Cs-137 significantly reduced the concentrations, whereas the long half-life of I-129(1.57x10{sup 7} years) and Am-241(432 years) remain stable concentrations at the interface of waste canister and concrete barrier after 300 years. The mineral saturation index (SI) was much less than zero due to the low aqueous concentration of radionuclide, so that the precipitation formation of Co-60, Sr-90, I-129, Cs-137 and Am-241 related minerals were not found. The effect of adsorption/desorption (i.e., surface complexation model) could be a crucial geochemical mechanism for the modeling of liquid-solid phase behavior of radionuclide in geochemically dynamic environments. Moreover, the development of advanced numerical models that are coupled with hydrogeochemical transport and dose assessment of radionuclide is required in the future. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solid Secondary Waste Form Testing Activities for the Integrated Disposal Facility Performance Assessment Support - 17567

Solid secondary waste (SSW) that will be generated at the Waste Treatment and Immobilization Plant (WTP) and from other activities at the Hanford site is destined for disposal at the Integrated Disposal Facility (IDF). Construction of the IDF was undertaken based on a Performance Assessment (PA) performed in 2001. In 2016, a SSW data package was prepared to support the development of an updated PA (2017 IDF PA). There are many inputs required to support the IDF PA. Data needs were identified based on experience from the previous PAs and from the development of conceptual models and modeling approaches to be applied for the 2017 PA. Interactions with the IDF PA team and the inventory data package developer helped to focus detailed efforts on a few key waste streams, contaminants of concern, and disposal configurations that are expected to be the primary contributors to the dose resulting from SSW disposed at the IDF. The key waste streams include: High Efficiency Particulate Air (HEPA) filters, ion exchange resins, granular activated carbon, and Ag-mordenite. The key parameters addressed in the 2016 data package include: saturated hydraulic conductivity, moisture characteristic curves, effective diffusion coefficient, distribution coefficient and porosity. The IDF PA team also identified a set of key contaminants that are expected to be the primary concern for the PA calculations (Tc-99, I-129, Cs-137, Sr-90, uranium isotopes (and total uranium), chromium, mercury and nitrate). These contaminants were the focus of the SSW data package. Specific formulations had not been identified for cementitious materials that will be used to encapsulate or stabilize SSW, and no IDF-specific experiments had been conducted to obtain the data for the PA. Thus, for the 2016 SSW data package, recommended property values were provided for a range of representative candidate materials based on a review of existing literature. However, starting in FY17, IDF-specific experiments will be performed for Hanford SSW expected to contribute most significantly to the dose for the IDF. This paper will summarize the information obtained for the 2016 data package and the plans for further testing to refine key inputs for the IDF PA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wide-Temperature Electrolytes for Lithium-Ion Batteries

Formulating electrolytes with solvents of low freezing points and high dielectric constants is a direct approach to extend the service temperature range of lithium (Li)-ion batteries (LIBs), for which propylene carbonate (PC), ethyl methyl carbonate (EMC), diethyl carbonate (DEC), methyl butyrate (MB) are excellent candidates. In this work, we report such low temperature electrolyte formulations by optimizing the content of ethylene carbonate (EC) in the EC-PC-EMC ternary solvent system with LiPF6 salt and CsPF6 additive. An extended service temperature range from 40°C to 60°C was obtained in LIBs with lithium nickel cobalt aluminum mixed oxide (LiNi0.80Co0.15Al0.05O2, NCA) as cathode and graphite as anode. The discharge capacities at low temperatures and the cycle life at room and elevated temperatures were systematically investigated in association with the ionic conductivity and phase transition behaviors. The most promising electrolyte formulation was identified as 1.0 M LiPF6 in EC-PC-EMC (1:1:8 by wt.) with 0.05 M CsPF6, which was demonstrated in both coin cells of graphite||NCA and 1 Ah pouch cells of graphite||LiNi1/3Mn1/3Co1/3O2. This optimized electrolyte enables excellent wide-temperature performances, as evidenced by the 68% capacity retention at 40C and C/5 rate, and nearly identical stable cycle life at room and elevated temperatures up to 60C.

25 ENERGY STORAGE↗

Penetration of Fission Products Ions into Complex Solids and the Effect of Ionic Wash Methods

During washing of radiologically impacted building surfaces, penetration of radionuclide ions into complex solids associated with these surfaces may occur. This study investigates the penetration of Cs-137, Sr-85, and Eu-152 solutions into numerous common building materials and radionuclide behavior when these materials were exposed to a static bath or low-pressure flow of tap water, 0.1 M potassium chloride (KCl), and 0.5 M KCl. The decontamination efficacy and the depth profile for residual contamination were measured to determine the conditions under which applying a wash solution has benefit compared to physically removing the surface material. On asphalt, 70-80% of the radionuclides were found to be within 0.02 mm of the surface. Concrete is more porous than asphalt, and 80% of the radionuclides were within 0.2 mm of the surface for Cs-137 and Eu-152 and 50-80% for Sr-85. Water effectively removed all contaminants from hard nonporous surfaces. Finally, this paper illustrates that a wash penalty factor concept-defined as ratio of the depth at which 50% of the radioactivity is found in the washed sample divided by the depth at which 50% of radioactivity is found in the control-can serve as a way to quantify whether the wash method increases the depth at which contamination penetrates into the material and thus the material becomes more difficult to decontaminate.

building materials↗

The Use of Subsurface Barriers to Support Treatment of Metals and Reduce the Flux of Tritium to Fourmile Branch at the Savannah River Site in South Carolina - 13358

The Savannah River Site (SRS) produced tritium, plutonium, and special nuclear materials for national defense, medicine, and the space programs. Acidic groundwater plumes containing metals, metallic radionuclides, non-metallic radionuclides and tritium sourced from the F and H Area Seepage Basins have impacted the surface water of Fourmile Branch on SRS. Tritium releases from Fourmile Branch have impacted the water quality within areas of the Savannah River adjacent to the SRS, and this circumstance has been an ongoing regulatory concern. The F and H Area Seepage Basins operated until 1988 for the disposition of deionized acidic waste water from the F and H Separations Facilities. The waste water contained dilute nitric acid and low concentrations of non-radioactive metals, and radionuclides, with the major isotopes being Cs-137, Sr-90, U-235, U-238, Pu-239, Tc-99, I-129, and tritium. The tritium concentration in the waste water was relatively elevated because there is not a practicable removal method in water. The acid content of the waste water during the operational period of the basins was equal to 12 billion liters of nitric acid. The seepage basins were closed in 1988 and backfilled and capped by 1991. The plumes associated with the F and H basins cover an area of nearly 2.4 square kilometers (600 acres) and discharge along ∼2,600 meters of Fourmile Branch. The acidic nature of the plumes and their overall discharge extent along the branch represent a large challenge with respect to reducing contaminant flux to Fourmile Branch. The introduction of nitric acid into the groundwater over a long time effectively reduced the retardation of metal migration from the basins to the groundwater and in the groundwater to Fourmile Branch, because most negatively charged surfaces on the aquifer materials were filled with hydrogen ion. Two large pump and treat systems were constructed in 1997 and operated until 2003 in an attempt to capture and control the releases to Fourmile Branch. The operating cost, including waste disposal, for the two systems was ∼$1.3 M/month. Both systems employed reinjection of tritiated water up gradient of the extraction, and produced large quantities of waste from non-tritium isotopes and metals removal prior to reinjection. Both systems were determined to be ineffective and potentially detrimental with respect to limiting the flux of contaminants to Fourmile Branch. After it became apparent that there was very little benefit to continued operation of the systems, and the staggering cost of operations was recognized by the SRS and regulators, a new remedy was developed. The new system uses vertical subsurface barriers to redirect groundwater flow to limit the transport of contaminants to the stream. The barriers were constructed of acid resistant grout using deep soil mixing techniques. The grout mixture used low swelling clay, fly ash, and sodium hydroxide to form a pozzolana material with low permeability and low strength. The SRS and regulators agreed to a series of remedial goals, with the first goal to reduce tritium flux to the stream by 70% and bring constituents other than tritium to groundwater protection standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hot-Isostatic Pressing of Sellafield SIXEP Sand/Clinoptilolite Wastes - 18281

Clinoptilolite is an ion-exchange material currently in use at the SIXEP plant (Sellafield, UK) to remove radioactive Cs and Sr from aqueous solution. Clinoptilolite material exists in a granular form that requires consolidation prior to disposal in a Geological Disposal Facility (GDF). The existing baseline treatment technology is to produce cementitious waste packages, which is not ideal due to the large increase in waste volume and poor quality of the wasteform produced. Hot-Isostatic Pressing (HIPing) has been investigated as an alternative treatment method to immobilise this material. This paper presents the results of an investigation that illustrates the capability to process clinoptilolite into a durable, monolithic glass-ceramic wasteform, which should be considered suitable for GDF disposal. The product of HIPing SIXEP sand /clinoptilolite materials is a dense vitreous wasteform with a small quantity of crystalline inclusions, primarily in the form of quartz/cristobalite. Under PCT testing the wasteform produced was shown to be at least an order of magnitude more durable than glasses currently used for the immobilisation of High-Level Wastes (HLW). It was calculated that the treatment of SIXEP sand/clinoptilolite wastes using HIP technology will provide at least a 6.3-fold reduction in the number of waste packages which require management and disposal. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Response of lithium formate EPR dosimeters at photon energies relevant to the dosimetry of brachytherapy

Purpose: To investigate experimentally the energy dependence of the detector response of lithium formate EPR dosimeters for photon energies below 1 MeV relative to that at {sup 60}Co energies. High energy photon beams are used in calibrating dosimeters for use in brachytherapy since the absorbed dose to water can be determined with high accuracy in such beams using calibrated ion chambers and standard dosimetry protocols. In addition to any differences in mass-energy absorption properties between water and detector, variations in radiation yield (detector response) with radiation quality, caused by differences in the density of ionization in the energy imparted (LET), may exist. Knowledge of an eventual deviation in detector response with photon energy is important for attaining high accuracy in measured brachytherapy dose distributions. Methods: Lithium formate EPR dosimeters were irradiated to known levels of air kerma in 25-250 kV x-ray beams and in {sup 137}Cs and {sup 60}Co beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free in air into values of mean absorbed dose to the detectors were made using EGSnrc MC simulations and x-ray energy spectra measured or calculated for the actual beams. The signals from the detectors were measured using EPR spectrometry. Detector response (the EPR signal per mean absorbed dose to the detector) relative to that for {sup 60}Co was determined for each beam quality. Results: Significant decreases in the relative response ranging from 5% to 6% were seen for x-ray beams at tube voltages {<=}180 kV. No significant reduction in the relative response was seen for {sup 137}Cs and 250 kV x rays. Conclusions: When calibrated in {sup 60}Co or MV photon beams, corrections for the photon energy dependence of detector response are needed to achieve the highest accuracy when using lithium formate EPR dosimeters for measuring absorbed doses around brachytherapy sources emitting photons in the energy range of 20-150 keV such as {sup 169}Yb and electronic sources.

61 RADIATION PROTECTION AND DOSIMETRY↗

New hypodiphosphates of the alkali metals: Synthesis, crystal structure and vibrational spectra of the hypodiphosphates(IV) M{sub 2}[(H{sub 2}P{sub 2}O{sub 6})(H{sub 4}P{sub 2}O{sub 6})] (M=Rb and Cs)

The new hypodiphosphates(IV) Rb{sub 2}[(H{sub 2}P{sub 2}O{sub 6})(H{sub 4}P{sub 2}O{sub 6})] (1) and Cs{sub 2}[(H{sub 2}P{sub 2}O{sub 6})(H{sub 4}P{sub 2}O{sub 6})] (2) were synthesized by soft chemistry reactions from aqueous solutions of hypophosphoric acid and the corresponding heavy alkali-metal carbonates. Their crystal structures were determined by single crystal X-ray diffraction. Both compounds crystallize isotypic in the triclinic space group P-1 with one formula unit in the unit cell. The structures are built up by discrete (H{sub 2}P{sub 2}O{sub 6}){sup 2-} and (H{sub 4}P{sub 2}O{sub 6}) units in staggered conformation for the P{sub 2}O{sub 6} skeleton and the corresponding alkali-metal cations. In the (H{sub 2}P{sub 2}O{sub 6}){sup 2-} ion the hydrogen atoms are in a 'trans-trans' conformation. O{center_dot}H-O hydrogen bonds between the (H{sub 2}P{sub 2}O{sub 6}){sup 2-} and (H{sub 4}P{sub 2}O{sub 6}) groups consolidate the structures into a three-dimensional network. The FT-Raman and {sup 31}P and {sup 1}H and MAS NMR spectra of the title compounds have been recorded and interpreted, especially with respect to their assignment to the (H{sub 2}P{sub 2}O{sub 6}){sup 2-} and (H{sub 4}P{sub 2}O{sub 6}) groups. Thermogravimetric data of 2 have been interpreted in terms of a thermal decomposition model. - Graphical Abstract: The layered compounds Rb{sub 2}[(H{sub 2}P{sub 2}O{sub 6})(H{sub 4}P{sub 2}O{sub 6})] and Cs{sub 2}[(H{sub 2}P{sub 2}O{sub 6})(H{sub 4}P{sub 2}O{sub 6})] have been synthesized and investigated. Both crystallize isotypic. The structures are built up by discrete (H{sub 2}P{sub 2}O{sub 6}){sup 2-} and (H{sub 4}P{sub 2}O{sub 6}) units and the corresponding alkali-metal cations. Highlights: Black-Right-Pointing-Pointer Synthesis and single-crystal structure of new alkali hypodiphosphates. Black-Right-Pointing-Pointer Structures are characterized by [(H{sub 2}P{sub 2}O{sub 6})(H{sub 4}P{sub 2}O{sub 6})]{sup 2-} units and M{sup +} cations. Black-Right-Pointing-Pointer (H{sub 2}P{sub 2}O{sub 6}){sup 2-} and (H{sub 4}P{sub 2}O{sub 6}) units are linked by short hydrogen bonds. Black-Right-Pointing-Pointer Both compounds are characterized by {sup 31}P MAS-NMR spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LABORATORY OPTIMIZATION TESTS OF TECHNETIUM DECONTAMINATION OF HANFORD WASTE TREATMENT PLANT LOW ACTIVITY WASTE OFF-GAS CONDENSATE SIMULANT

The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrification mission duration and quantity of glass waste. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to acceptable concentrations in the LAW glass, and diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task examines the potential treatment of this stream to remove radionuclides and subsequently disposition the decontaminated stream elsewhere, such as the Effluent Treatment Facility (ETF), for example. The treatment process envisioned is very similar to that used for the Actinide Removal Process (ARP) that has been operating for years at the Savannah River Site (SRS), and focuses on using mature radionuclide removal technologies that are also compatible with longterm tank storage and immobilization methods. For this new application, testing is needed to demonstrate acceptable treatment sorbents and precipitating agents and measure decontamination factors for additional radionuclides in this unique waste stream. The origin of this LAW Off-Gas Condensate stream will be the liquids from the Submerged Bed Scrubber (SBS) and the Wet Electrostatic Precipitator (WESP) from the LAW melter off-gas system. The stream is expected to be a dilute salt solution with near neutral pH, and will likely contain some insoluble solids from melter carryover. The soluble components are expected to be mostly sodium and ammonium salts of nitrate, chloride, and fluoride. This stream has not been generated yet and will not be available until the WTP begins operation, but a simulant has been produced based on models, calculations, and comparison with pilot-scale tests. One of the radionuclides that is volatile and expected to be in greatest abundance in this LAW Off-Gas Condensate stream is Technetium-99 ({sup 99}Tc). Technetium will not be removed from the aqueous waste in the Hanford WTP, and will primarily end up immobilized in the LAW glass by repeated recycle of the off-gas condensate into the LAW melter. Other radionuclides that are low but are also expected to be in measurable concentration in the LAW Off-Gas Condensate are {sup 129}I, {sup 90}Sr, {sup 137}Cs, {sup 241}Pu, and {sup 241}Am. These are present due to their partial volatility and some entrainment in the off-gas system. This report discusses results of optimized {sup 99}Tc decontamination testing of the simulant. Testing examined use of inorganic reducing agents for {sup 99}Tc. Testing focused on minimizing the quantity of sorbents/reactants added, and minimizing mixing time to reach the decontamination targets in this simulant formulation. Stannous chloride and ferrous sulfate were tested as reducing agents to determine the minimum needed to convert soluble pertechnetate to the insoluble technetium dioxide. The reducing agents were tried with and without sorbents. The sorbents, hydroxyapatite and sodium oxalate, were expected to sorb the precipitated technetium dioxide and facilitate removal. The Phase 1 tests examined a broad range of conditions and used the initial baseline simulant. The Phase 2 tests narrowed the conditions based on Phase 1 results, and used a slightly modified simulant. Test results indicate that excellent removal of {sup 99}Tc was achieved using SnCl{sub 2} as a reductant, and was effective with or without sorption onto hydroxyapatite. This reaction worked even in the presence of air (which could oxidize the stannous ion) and at room temperature. This process was very effective at neutral pH, with a Decontamination Factor (DF) >199 in one hour with only 1 g/L of SnCl{sub 2}. Prior work had shown that it was much less effective at alkaline pH. The only deleterious effect observed was that the chromium co-precipitates with the {sup 99}c during the SnCl{sub 2} reduction. This effect was anticipated, and would have to be considered when managing disposition paths of this stream. Reduction using FeSO{sub 4} was not effective at removing {sup 99}Tc, but did remove the Cr. Chromium is present due to partial volatility and entrainment in the off-gas, and is highly oxidizing, so would be expected to react with reducing agents more quickly than pertechnetate. Testing showed that sufficient reducing agent must be added to completely reduce the chromium before the technetium is reduced and removed. Other radionuclides are also present in this off-gas condensate stream. To enable sending this stream to the Hanford ETF, and thereby divert it from the recycle where it impacts the LAW glass volume, several of these also need to be removed. Samples from optimized conditions were also measured for actinide removal in order to examine the effect of the Tc-removal process on the actinides. Plutonium was also removed by the SnCl{sub 2} precipitation process. Results of this separation testing indicate that sorption/precipitation is a viable concept and has the potential to decontaminate the {sup 99}Tc from the stream, allowing it to be diverted away from WTP and thus eliminating the impact of the recycled halides and sulfate on the LAW glass volume. Based on the results, a possible treatment scenario could involve the use of a reductive precipitation agent (SnCl{sub 2}) with or without sorbent at neutral pH to remove the Tc. Although hydroxyapatite was not necessary to effect the {sup 99}Tc removal, it may be beneficial in solid-liquid separations. Other testing will examine removal of the other radionuclides. This testing was the second phase of testing, which aimed at optimizing the process by examining the minimum amount of reductant needed and the minimum reaction time. Although results indicated that SnCl{sub 2} was effective, further work on a pH-adjusted Fe(SO{sub 4}) mixture are needed. Additional tasks are needed to examine removal of the other radionuclides, solid-liquid separation technologies, slurry rheology measurements, composition variability impacts, corrosion and erosion, and slurry storage and immobilization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV)

Purpose: High energy photon beams are used in calibrating dosimeters for use in brachytherapy since absorbed dose to water can be determined accurately and with traceability to primary standards in such beams, using calibrated ion chambers and standard dosimetry protocols. For use in brachytherapy, beam quality correction factors are needed, which include corrections for differences in mass energy absorption properties between water and detector as well as variations in detector response (intrinsic efficiency) with radiation quality, caused by variations in the density of ionization (linear energy transfer (LET) -distributions) along the secondary electron tracks. The aim of this work was to investigate experimentally the detector response of LiF:Mg,Ti thermoluminescent dosimeters (TLD) for photon energies below 1 MeV relative to {sup 60}Co and to address discrepancies between the results found in recent publications of detector response. Methods: LiF:Mg,Ti dosimeters of formulation MTS-N Poland were irradiated to known values of air kerma free-in-air in x-ray beams at tube voltages 25-250 kV, in {sup 137}Cs- and {sup 60}Co-beams at the Swedish Secondary Standards Dosimetry Laboratory. Conversions from air kerma free-in-air into values of mean absorbed dose in the dosimeters in the actual irradiation geometries were made using EGSnrc Monte Carlo simulations. X-ray energy spectra were measured or calculated for the actual beams. Detector response relative to that for {sup 60}Co was determined at each beam quality. Results: An increase in relative response was seen for all beam qualities ranging from 8% at tube voltage 25 kV (effective energy 13 keV) to 3%-4% at 250 kV (122 keV effective energy) and {sup 137}Cs with a minimum at 80 keV effective energy (tube voltage 180 kV). The variation with effective energy was similar to that reported by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with our values being systematically lower by 2%-4%. Compared to the results by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], the relative detector response as a function of effective energy differed in both shape and magnitude. This could be explained by the higher maximum read-out temperature (350 deg. C) used by Nunn et al.[Med. Phys. 35, 1861-1869 (2008)], allowing light emitted from high-temperature peaks with a strong LET dependence to be registered. Use of TLD-100 by Davis et al.[Radiat. Prot. Dosim. 106, 33-43 (2003)] with a stronger super-linear dose response compared to MTS-N was identified as causing the lower relative detector response in this work. Conclusions: Both careful dosimetry and strict protocols for handling the TLDs are required to reach solid experimental data on relative detector response. This work confirms older findings that an over-response relative to {sup 60}Co exists for photon energies below 200-300 keV. Comparison with the results from the literature indicates that using similar protocols for annealing and read-out, dosimeters of different makes (TLD-100, MTS-N) differ in relative detector response. Though universality of the results has not been proven and further investigation is needed, it is anticipated that with the use of strict protocols for annealing and read-out, it will be possible to determine correction factors that can be used to reduce uncertainties in dose measurements around brachytherapy sources at photon energies where primary standards for absorbed dose to water are not available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗