Synoptic planetary imaging with the LST high-resolution camera

The value of synoptic imaging of the planets is illustrated. Advantages of the large space telescope, as compared with ground based telescopes, planetary orbiters, and flybys are discussed. Desirable LST camera parameters and observing strategies are considered from the standpoint of synoptic imaging.

Baum, W. A.↗

Study of Permanent Magnet Focusing for Astronomical Camera Tubes

A design is developed of a permanent magnet assembly (PMA) useful as the magnetic focusing unit for the 35 and 70 mm (diagonal) format SEC tubes. Detailed PMA designs for both tubes are given, and all data on their magnetic configuration, size, weight, and structure of magnetic shields adequate to screen the camera tube from the earth's magnetic field are presented. A digital computer is used for the PMA design simulations, and the expected operational performance of the PMA is ascertained through the calculation of a series of photoelectron trajectories. A large volume where the magnetic field uniformity is greater than 0.5% appears obtainable, and the point spread function (PSF) and modulation transfer function(MTF) indicate nearly ideal performance. The MTF at 20 cycles per mm exceeds 90%. The weight and volume appear tractable for the large space telescope and ground based application.

Long, D. C.↗

Investigation of Facsimile Camera-spectrometer Capability in the 1.0 to 2.7 Micron Spectral Range

The capability of the facsimile camera augmented with a filter-spectrometer to provide scientifically valuable information in the 1.0 to 2.7 microns spectral range was investigated for a future planetary lander mission to Mars. A computer model was used to evaluate tradeoffs between signal-to-noise ratio, spatial and spectral resolution, and the number of spectral channels. Spectral absorption features resulting from water and chemical variations found in pyroxenes were used to represent scientific information of interest to biologists and geologists. Expected output data from a filter-spectrometer is illustrated which indicates that important information pertaining to water content and chemical composition can be obtained using six to eight spectral channels with 0.3 degree spatial resolution.

Kelly, W. L., IV↗

Camera memory study for large space telescope

Specifications were developed for a memory system to be used as the storage media for camera detectors on the large space telescope (LST) satellite. Detectors with limited internal storage time such as intensities charge coupled devices and silicon intensified targets are implied. The general characteristics are reported of different approaches to the memory system with comparisons made within the guidelines set forth for the LST application. Priority ordering of comparisons is on the basis of cost, reliability, power, and physical characteristics. Specific rationales are provided for the rejection of unsuitable memory technologies. A recommended technology was selected and used to establish specifications for a breadboard memory. Procurement scheduling is provided for delivery of system breadboards in 1976, prototypes in 1978, and space qualified units in 1980.

Hoffman, C. P.↗

Station coordinates in the standard earth 3 system and radiation-pressure perturbations from ISAGEX camera data

Simultaneous and individual camera observations of GEOS 1, GEOS 2, Pageos, and Midas 4 obtained during the International Satellite Geodesy Experiment are utilized to determine station coordinates. The Smithsonian Astrophysical Observatory Standard Earth III system of coordinates is used to tie the geometrical network to a geocentric system and as a reference for calculating satellite orbits. A solution for coordinates combining geometrical and dynamical methods is obtained, and a comparison between the solutions and terrestrial data is made. The radiation-pressure and earth-albedo perturbations for Pageos are very large, and Pageos' orbits are used to evaluate the analytical treatment of these perturbations. Residual effects, which are probably of interest to aeronomists, remain in the Pageos orbits.

Gaposchkin, E. M.↗

Electronic magnification for astronomical camera tubes

Definitions, test schemes, and analyses used to provide variable magnification in the image section of the television sensor for large space telescopes are outlined. Experimental results show a definite form of magnetic field distribution is necessary to achieve magnification in the range 3X to 4X. Coil systems to establish the required field shapes were built, and both image intensifiers and camera tubes were operated at high magnification. The experiments confirm that such operation is practical and can provide satisfactory image quality. The main problem with such a system was identified as heating of the photocathode due to concentration of coil power dissipation in that vicinity. Suggestions for overcoming this disadvantage are included.

Vine, J.↗

A technique for constructing spectral reflectance curves from Viking lander camera multispectral data

A technique for evaluating the construction of spectral reflectance curves from multispectral data obtained with the Viking lander cameras is presented. The multispectral data is limited to 6 channels in the wave-length range 0.4 to 1.1 microns, and several of the channels suffer from appreciable out-of-band response. The technique represents the estimated reflectance curves as a linear combination of known basic functions with coefficients determined to minimize the error in the representation, and it permits all channels, with and without out-of-band response, to contribute equally valid information. The technique is evaluated for known spectral reflectance curves of 8 materials felt likely to be present on the Martian surface. The technique provides an essentially exact fit if the the reflectance curve has no pronounced maxima and minima. Even if the curve has pronounced maxima and minima, the fit is good and reveals the most dominant features. Since only 6 samples are available some short period features are lost. This loss is almost certainly due to undersampling rather than out-of-band channel response.

Park, S. K.↗

DC drive system for cine/pulse cameras

Camera-drive functions are separated mechanically into two groups which are driven by two separate dc brushless motors. First motor, a 90 deg stepper, drives rotating shutter; second electronically commutated motor drives claw and film transport. Shutter is made of one piece but has two openings for slow and fast exposures.

Gerlach, R. H.↗

Development of a drive system for a sequential space camera

An electronically commutated dc motor is reported for driving the camera claw and magazine, and a stepper motor is described for driving the shutter with the two motors synchronized electrically. Subsequent tests on the breadboard positively proved the concept, but further development beyond this study should be done. The breadboard testing also established that the electronically commutated motor can control speed over a wide dynamic range, and has a high torque capability for accelerating loads. This performance suggested the possibility of eliminating the clutch from the system while retaining all of the other mechanical features of the DAC, if the requirement for independent shutter speeds and frame rates can be removed. Therefore, as a final step in the study, the breadboard shutter and shutter drive were returned to the original DAC configuration, while retaining the brushless dc motor drive.

Sharpsteen, J. T.↗

Development of a drive system for a sequential space camera

Breadboard models of single and dual motor drives for the shutter, claw and magazine of a space camera system were designed and tested. The single motor technique utilizes a single electronically commutated motor to drive the claw and shutter without resorting to a solenoid actuated clutch for pulse operation. Shutter speed is established by a combination of the cinemode speed and the opening of the conventional DAC two piece shutter. Pulse mode operation is obtained by applying power at a fixed clock rate and removing power at an appropriate point in the mechanical cycle such that the motor comes to rest by system friction. The dual motor approach utilizes a stepper motor to drive the shutter and an electronically commutated dc motor to drive the claw and magazine functions. The motors are synchronized electronically.

Sharpsteen, J. T.↗

Station coordinates in the Standard Earth III system derived by using camera data from ISAGEX

Simultaneous and individual camera observations of Geos 1, Geos 2, Pageos, and Midas 4 obtained during the International Satellite Geodesy Experiment are used to determine station coordinates. The Smithsonian Astrophysical Observatory Standard Earth III system of coordinates is utilized to tie the geometrical network to a geocentric system and as a reference for calculating satellite orbits. The normal systems for geometrical and dynamical solutions are combined.

Gaposchkin, E. M.↗

ATS-6 - Television camera reflector monitor

A black and white television camera was used to observe the 9-m-diameter reflector after deployment to assure proper configuration. It also observes the reflector periodically to assure that no anomalies go undetected. It has been sending excellent pictures which verify that the reflector deployed properly and remains in good shape.

Patterson, G.↗

Fine particles on Mars - Observations with the Viking 1 lander cameras

Drifts of fine-grained sediment are present in the vicinity of the Viking 1 lander. Many drifts occur in the lees of large boulders. Morphologic analysis indicates that the last dynamic event was one of general deflation for at least some drifts. Particle cohesion implies that there is a distinct small-particle upturn in the threshold velocity-particle size curve; the apparent absence of the most easily moved particles (150 micrometers in diameter) may be due to their preferential transport to other regions or their preferential collisional destruction. A twilight rescan with lander cameras indicates a substantial amount of red dust with mean radius on the order of 1 micrometer in the atmosphere.

Mutch, T. A.↗

Cubic spline reflectance estimates using the Viking lander camera multispectral data

A technique was formulated for constructing spectral reflectance estimates from multispectral data obtained with the Viking lander cameras. The output of each channel was expressed as a linear function of the unknown spectral reflectance producing a set of linear equations which were used to determine the coefficients in a representation of the spectral reflectance estimate as a natural cubic spline. The technique was used to produce spectral reflectance estimates for a variety of actual and hypothetical spectral reflectances.

Park, S. K.↗

Evaluation of a large format image tube camera for the shuttle sortie mission

A large format image tube camera of a type under consideration for use on the Space Shuttle Sortie Missions is evaluated. The evaluation covers the following subjects: (1) resolving power of the system (2) geometrical characteristics of the system (distortion etc.) (3) shear characteristics of the fiber optic coupling (4) background effects in the tube (5) uniformity of response of the tube (as a function of wavelength) (6) detective quantum efficiency of the system (7) astronomical applications of the system. It must be noted that many of these characteristics are quantitatively unique to the particular tube under discussion and serve primarily to suggest what is possible with this type of tube.

Tifft, W. C.↗

Space telescope optical telescope assembly/scientific instruments. Phase B: Preliminary design and program definition study. Volume 2A. focal plane camera

Trade studies were conducted to ensure the overall feasibility of the focal plane camera in a radial module. The primary variable in the trade studies was the location of the pickoff mirror, on axis versus off-axis. Two alternatives were: (1) the standard (electromagnetic focus) SECO submodule, and (2) the MOD 15 permanent magnet focus SECO submodule. The technical areas of concern were the packaging affected parameters of thermal dissipation, focal plane obscuration, and image quality.

Source record↗

Measurement of insulation integrity of IUE camera tube facsimiles by partial discharges method and diffusion of gases through various silicone rubbers

Several dummy tubes imitating the IUE Camera System design were encapsulated with Solithane 2, Conathane EN-11, Green and Black Hysols and SMRD 432. Various flaws were purposefully placed in some of these. Partial discharge testing in vacuum under direct voltage conditions was carried once a week for 12 weeks, 15 kv dc being applied during normal working hours for 40 hours duration per week. None of the units showed much damage during this time judging by the P.D. energy histograms. A more complete mathematical presentation is given on diffusion and permeation than previously. Measurements of diffusion constants for various silicone rubbers are carried out by the Time-Lag method and compared to other determinations in the literature. Calculations of the time required for diffusion through a thick wall are demonstrated in the long time approximation and for dimensions pertaining to void and wall sizes of a delamination problem in the LANDSAT-C vidicon tubes. An actual delaminated LANDSAT-C tube and some facsimiles are immersed in vacuum for long periods and tested for catastrophic breakdown due to diffusion of gas, by application of high voltage.

Bever, R. S.↗

The Viking Orbiter cameras' potential for photometric measurement

Although photometry of Mars is not listed as a major mission objective, the Viking Project has provided the Orbiter Imaging Team with cameras exhibiting significant improvement in photometric measurement as compared with past Mariners. Sample calibration data are described, together with predicted performance capabilities.

Thorpe, T. E.↗