Wireless Deployable Fresnel Rings Signal Booster
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The future discoveries in the field of High Energy Physics are led by the development of new types of accelerators. Around the world, there are a lot of researchers that are studying some possible designs for the future accelerators and some of them are considering the use of alternating current inside the superconducting magnets in order to have better efficiency. The work described in this report tries to compare some superconducting magnets made of different materials and to understand which one of them can be considered for its better performance working in a variable magnetic field. For this goal, becomes really important to control the temperature of the coil, and, as visible in the next chapter, to relate this parameter to the frequency of the magnetic field, in order to find, as will be named, the critical frequency .
The NOvA experiment’s most recent search for eV-scale sterile neutrinos under a 3+1 model simultaneously analyses muon neutrino and neutral current datasets from the NuMI beam at it's Near ($\sim$1 km baseline) and Far (810 km baseline) detectors to look for oscillations consistent with a sterile neutrino. The analysis is systematically limited in the region of parameter space where $\Delta m^{2}_{41} $>~1 eV^2$. This region of parameter space is preferred by sterile neutrino interpretations of current experimental anomalies and so improving sensitivity here is high-priority. The Near Detector’s position on-site at Fermilab means that it is also able to observe neutrinos from a second neutrino beam, the BNB, 160 mrad off-axis. This data probes a similar L/E to the NuMI data, but using a different neutrino energy, and being subject to different beam-related uncertainties. Jointly analysing these datasets can help us to constrain our systematic uncertainties, improving our sensitivity. NOvA has been taking BNB data since 2015, but has not yet analysed these data. This poster will present first sensitivities from the combined analysis of the BNB and NuMI datasets.
Synchrotron light cna be produced from a relativistic particle beam circulating in a storage ring at extremely high intensity and brilliance over a large spectral region reaching from the far infrared regime to hard x-rays. The particles, either electrons or positrons, radiate as they are deflected in the fields of the storage ring bending magnets or of magnets specially optimized for the production of synchrotron light. The synchrotron light being very intense and well collimated in the forward direction has become a major tool in a large variety of research fields in physics, chemistry, material science, biology, and medicine.
This dissertation presents a search for v μ and $\bar{v}$ μ disappearance with the MiniBooNE experiment in the Δm 2 region of a few eV 2 . Disappearance measurements in this oscillation region constrain sterile neutrino models and CPT violation in the lepton sector. Fits to the shape of the v μ and $\bar{v}$ μ energy spectra reveal no evidence for disappearance in either mode. This is the first test of $\bar{v}$ μ disappearance between Δm 2 = 0.1 - 10 eV 2 . In addition, prospects for performing a joint analysis using the SciBooNE detector in conjunction with MiniBooNE are discussed.
A Gold ion with charge eQ has N = 197 Nucleons, Z = 79 Protons, and (Z-Q) electrons. (Here Q is an integer and e is the charge of a single proton.) The mass is m = au - Qm{sub e} + E{sub b}/c{sup 2} (1) where a = 196.966552 is the relative atomic mass [1, 2] of the neutral Gold atom, u = 931.494013 MeV/c{sup 2} is the unified atomic mass unit [3], and m{sub e}c{sup 2} = .510998902 MeV is the electron mass [3]. E{sub b} is the binding energy of the Q electrons removed from the neutral Gold atom. This amounts to 0.332 MeV for the helium-like gold ion (Q = 77) and 0.517 MeV for the fully stripped ion. For the Au{sup 31+} ion we have E{sub b} = 13.5 keV. These numbers are given in Ref. [4].
A Gold ion with charge eQ has N = 197 Nucleons, Z = 79 Protons, and (Z-Q) electrons. (Here Q is an integer and e is the charge of a single proton.) The mass is m = au - Qm{sub e} + E{sub b}/c{sup 2} (1) where a = 196.966552 is the relative atomic mass [1, 2] of the neutral Gold atom, u = 931.494013 MeV/c{sup 2} is the unified atomic mass unit [3], and m{sub e}c{sup 2} = .510998902 MeV is the electron mass [3]. E{sub b} is the binding energy of the Q electrons removed from the neutral Gold atom. This amounts to 0.332 MeV for the helium-like gold ion (Q = 77) and 0.517 MeV for the fully stripped ion. For the Au{sup 31+} ion we have E{sub b} = 13.5 keV. These numbers are given in Ref. [4]. The deuteron mass [3] is 1875.612762(75) MeV/c{sup 2}.
Study of techniques for reliability evaluation of solid-propellant rocket motor designs
Calorimeters for measuring radiation and convective heating on airborne vehicles
Explore the source record for details and available documents.
Destructive testing of scale model saturn i launch vehicle
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Aerodynamic damping of Saturn-Apollo vehicles dominated by separated flow
A relatively simple injection-guidance system used in conjunction with post-injection midcourse correction will be adequate for lunar and interplanetary missions.
Explore the source record for details and available documents.
Explore the source record for details and available documents.