Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Secondary Electron Emission from Dust and Its Effect on Charging

Hydrogen plasma is produced in a plasma chamber by striking discharge between incandescent tungsten filaments and the permanent magnetic cage [1], which is grounded. The magnetic cage has a full line cusped magnetic field geometry used to confine the plasma elements. A cylindrical Langmuir probe is used to study the plasma parameters in various discharge conditions. The charge accumulated on the dust particles is calculated using the capacitance model and the dust current is measured by the combination of a Faraday cup and an electrometer at different discharge conditions. It is found Secondary electron emission from dust having low emission yield effects the charging of dust particles in presence of high energetic electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The cyclotron laboratory and the RFQ accelerator in Bern

Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

07 ISOTOPE AND RADIATION SOURCES↗

Scanning cross-correlator for monitoring uniform 3D ellipsoidal laser beams

The specific features of experimental implementation of a cross-correlator with a scan rate above 1600 cm s{sup -1} and a spatial delay amplitude of more than 15 mm are considered. The possibility of measuring the width of femtosecond pulses propagating in a train 300 μs in duration with a repetition rate of 1 MHz is demonstrated. A time resolution of 300 fs for the maximum time window of 50 ps is attained. The cross-correlator is aimed at testing 3D pulses of a laser driver of an electron photo-injector. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the CMS detector for the CERN LHC Run 3

Since the initial data taking of the CERN LHC, the CMSexperiment has undergone substantial upgrades and improvements. Thispaper discusses the CMS detector as it is configured for the thirddata-taking period of the CERN LHC, Run 3, which started in2022. The entire silicon pixel tracking detector was replaced. A newpowering system for the superconducting solenoid was installed. Theelectronics of the hadron calorimeter was upgraded. All the muonelectronic systems were upgraded, and new muon detector stationswere added, including a gas electron multiplier detector. Theprecision proton spectrometer was upgraded. The dedicated luminositydetectors and the beam loss monitor were refurbished. Substantialimprovements to the trigger, data acquisition, software, andcomputing systems were also implemented, including a new hybridCPU/GPU farm for the high-level trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

StarDICE III: characterization of the photometric instrument with a collimated beam projector

The measurement of Type Ia supernovae magnitudes provides cosmological distances, which constrain dark energy parameters. Current and upcoming large photometric surveys require improved photometric calibration precision to reduce systematic uncertainties in cosmological constraints. The StarDICE experiment aims to establish accurate broad-band flux references for these surveys, targeting sub-percent precision in magnitude measurements. Achieving this requires precise filter bandpass measurements for both StarDICE and survey instruments with sub-nanometre accuracy. To this end, we developed the Collimated Beam Projector (CBP), an optical device for calibrating the throughput of astronomical telescopes and their filters. The CBP uses a tunable laser source and a reversed telescope to emit a parallel monochromatic light beam, continuously monitored in flux and wavelength. The CBP output flux is measured with a large-area photodiode calibrated relative to a NIST photodiode. Using CBP measurements, we derive the StarDICE telescope throughput and filter transmissions, anchoring them to NIST’s absolute calibration. After analysing systematic uncertainties, we achieved sub-nanometre accuracy for filter central wavelengths, measured filter transmission with ~0.5 per cent precision per 1 nm bin, and detected out-of-band leakages at a relative level of 10 –4 ⁠. Furthermore, we synthesized equivalent transmission for full pupil illumination from four sampled positions in the StarDICE telescope mirror, with ~0.2 nm accuracy for central wavelengths and 7 mmag for broad-band fluxes. This demonstrates our ability to characterize telescope throughput down to the millimagnitude, paving the way for future developments, such as the Rubin-CBP for measuring the LSST at Vera Rubin Observatory, and a portable CBP version for in-situ transmission monitoring.

Calibration↗

Inverse modeling of circular lattices via orbit response measurements in the presence of degeneracy

The number and location of beam position monitors (BPMs) and steerers with respect to the quadrupoles in a circular lattice can lead to degeneracy in the context of fitting linear optics and extracting lattice information from measured closed orbits. Furthermore, the measurement uncertainties due to the imperfection of BPMs and steerers can be propagated by the fitting process in ways that prohibit the successful extraction of discrepancies between lattice elements in the real machine and their description in the corresponding model. We systematically studied the influence of the placement of BPMs and steerers on the reconstruction of linear optics and corresponding lattice information. The derivative of orbit response coefficients with respect to the quadrupole strengths, the Jacobian, is derived as an analytical formula. This analytical version of the Jacobian is used to further derive the theoretical limitations of fitting linear optics from closed orbits in terms of the placement of BPMs and steerers. It is further demonstrated that when evaluating the Jacobian during the fitting procedure, the analytical version can be used in place of the conventional finite-difference computation. This allows for greatly improved efficiency when computing the Jacobian during each iteration of the fitting procedure. The approach is tested with large-scale simulations and the findings are verified by measurement data taken on SIS18 synchrotron at GSI Helmholtz Centre for Heavy Ion Research. The presented methods are of general nature and can be applied to other accelerator lattices as well. The fitting procedure by using the analytical Jacobian is tested in conjunction with various methods for mitigating quasidegeneracy and the results agree with those obtained by using the conventional Jacobian via finite-difference approximation.

47 OTHER INSTRUMENTATION↗

Approximating the near-edge mass absorption coefficients for Ni using an ultra-thin bimetal foil

In an effort to improve the characteristics of a fluorescing metal-foil-based beam position monitor, a new bimetal ultra-thin (0.98/0.67 µm) Ti–Ni foil was introduced to replace an existing single-element ultra-thin 0.5 µm thick Cr foil. During characterization it was determined that absorption measurements on the bimetal foil could be used to fit the Ni mass absorption coefficients accurately in the vicinity of the Ni K edge. Comparison with experimental results from the literature demonstrated that the fitting procedure produced coefficients with uncertainties of the order of ±1%. Once determined, these fit coefficients allowed the thickness of an independently mounted 8 µm thick Ni foil to be computed from absorption measurements instead of relying on a tool-based measurement of the foil thickness. Using the 8 µm thick foil, a continuous map of Ni mass absorption coefficients was produced at 1 eV resolution throughout the near-edge region. Lastly, this high-resolution map marks a significant improvement over the existing NIST XCOM or FFAST database mass absorption coefficients, which have estimated errors of 10–20% for the near-edge region.

36 MATERIALS SCIENCE↗

FemtoMAX – an X-ray beamline for structural dynamics at the short-pulse facility of MAX IV

The FemtoMAX beamline facilitates studies of the structural dynamics of materials. Such studies are of fundamental importance for key scientific problems related to programming materials using light, enabling new storage media and new manufacturing techniques, obtaining sustainable energy by mimicking photosynthesis, and gleaning insights into chemical and biological functional dynamics. The FemtoMAX beamline utilizes the MAX IV linear accelerator as an electron source. The photon bursts have a pulse length of 100 fs, which is on the timescale of molecular vibrations, and have wavelengths matching interatomic distances (Å). The uniqueness of the beamline has called for special beamline components. This paper presents the beamline design including ultrasensitive X-ray beam-position monitors based on thin Ce:YAG screens, efficient harmonic separators and novel timing tools.

laser↗

Alignment and Testing of a Telecentric Zoom Lens Used for the Cygnus X-ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm (for future operations). All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Alignment of the optical elements was accomplished using counter propagating laser beams and monitoring the retro-reflections and steering collections of laser spots. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure, and can be used in either vertical or horizontal orientation.

zoom lens, telecentric lens design, optical metrol↗

Spill-to-spill and daily proton energy consistency with a new accelerator control system

The Loma Linda University proton accelerator has had several upgrades installed including synchrotron dipole power supplies and a system for monitoring the beam energy. The consistency of the energy from spill-to-spill has been tested by measuring the depth ionization at the distal edge as a function of time. These measurements were made with a minimally equipped beamline to reduce interference from confounding factors. The consistency of the energy over several months was measured in a treatment room beamline using an ionization chamber based daily quality assurance device. The results showed that the energy of protons delivered from the accelerator (in terms of water equivalent range) was consistent from spill-to-spill to better than {+-}0.03 mm at 70, 155, and 250 MeV and that the energy check performed each day in the treatment room over a several month period was within {+-}0.11 mm ({+-}0.06 MeV) at 149 MeV. These results are within the tolerances required for the energy stacking technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-587: Monte Carlo Versus Ray-Tracing for Treatment Planning Involving CNS Tumors On the MultiPlan System for CyberKnife Radiosurgery

Purpose: MultiPlan, the treatment planning system for the CyberKnife Robotic Radiosurgery system offers two approaches to dose computation, namely Ray-Tracing (RT), the default technique and Monte Carlo (MC), an option. RT is deterministic, however it accounts for primary heterogeneity only. MC on the other hand has an uncertainty associated with the calculation results. The advantage is that in addition, it accounts for heterogeneity effects on the scattered dose. Not all sites will benefit from MC. The goal of this work was to focus on central nervous system (CNS) tumors and compare dosimetrically, treatment plans computed with RT versus MC. Methods: Treatment plans were computed using both RT and MC for sites covering (a) the brain (b) C-spine (c) upper T-spine (d) lower T-spine (e) L-spine and (f) sacrum. RT was first used to compute clinically valid treatment plans. Then the same treatment parameters, monitor units, beam weights, etc., were used in the MC algorithm to compute the dose distribution. The plans were then compared for tumor coverage to illustrate the difference if any. All MC calculations were performed at a 1% uncertainty. Results: Using the RT technique, the tumor coverage for the brain, C-spine (C3–C7), upper T-spine (T4–T6), lower T-spine (T10), Lspine (L2) and sacrum were 96.8%, 93.1%, 97.2%, 87.3%, 91.1%, and 95.3%. The corresponding tumor coverage based on the MC approach was 98.2%, 95.3%, 87.55%, 88.2%, 92.5%, and 95.3%. It should be noted that the acceptable planning target coverage for our clinical practice is >95%. The coverage can be compromised for spine tumors to spare normal tissues such as the spinal cord. Conclusion: For treatment planning involving the CNS, RT and MC appear to be similar for most sites but for the T-spine area where most of the beams traverse lung tissue. In this case, MC is highly recommended.

60 APPLIED LIFE SCIENCES↗

Propagation of microwave beams through the stagnation zone in an inhomogeneous plasma

A study is made of the microwave beam evolution due to passing through the stagnation zone, where the group velocity vanishes, thus making the paraxial approximation for the wavefield inappropriate. An extension to the standard beam tracing technique is suggested that allows one to calculate the microwave beam parameters on either branch of its path apart from the stagnation zone, omitting the calculation of the wavefield inside it. Application examples of the extended technique are presented for the case of microwave reflection from the upper hybrid resonance layer in a tokamak plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LCLS RF Station Anomaly Candidates, SLAC, Nov 2020 to Dec 2020, Version 1

The data consists of radio-frequency (RF) station process variables (amplitude and amplitude-mean-out-of-tolerance bit) and beam position monitor (BPM) values for about a month of Linac Coherent Light Source (LCLS) time. The data is all from normal conducting hard X-ray operation. The dataset contains roughly 5000 anomaly “candidates.” For each candidate, we include 3.5 minutes of data from the 82 RF stations and ~20 seconds of data from 4 BPMs. We also include several CSV files with additional information and labels for each candidate.

43 PARTICLE ACCELERATORS↗

LBNL BPM Firmware (CAL-BPM) v1.0

CAL-BPM is the firmware code base of the Advanced Light Source (ALS) Beam Position Monitor (BPM) Field Programmable Gate Array (FPGA) based electronics.

Norum, William↗

PyEmittance

PyEmittance is a tool for the adaptive measurement of beam emittance (e.g. of an electron beam at OTR/YAG beam profile monitors) using a single quadrupole scan developed at SLAC National Accelerator Laboratory. The Twiss parameters and the 'Bmag' match parameter can also be obtained. It can be used in different beamlines/machines by defining machine-specific configuration files.

Miskovich, Sara A.↗

Transverse Beam Emittance Measurement by Undulator Radiation Power Noise

Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is unknown, this parameter can be determined from the measured magnitude of these power fluctuations. In this contribution, we report the results of our experiment at the Integrable Optics Test Accelerator (IOTA) storage ring, where we carried out an absolute measurement (no free parameters or calibration) of a small vertical emittance (5–15 nm rms) of a flat beam by this new method, under conditions, when the small vertical emittance is unresolvable by a conventional synchrotron light beam size monitor.

43 PARTICLE ACCELERATORS↗

Tunable Q-Factor Gas-Filled RF Cavity

Fermilab is the main institution to produce the most powerful and wide-spectrum neutrino beam. From that respective, a radiation robust beam diagnostic system is a critical element in order to maintain the quality of the neutrino beam. Within this context, a novel radiation-resistive beam profile monitor based on a gas-filled RF cavity has been proposed. The goal of this measurement is to study a tunable Q-factor RF cavity to determine the accuracy of the RF signal as a function of the quality factor. Specifically, the measurement error of the Q-factor in the RF calibration is investigated. Then, the RF system will be improved to minimize signal error.

43 PARTICLE ACCELERATORS↗