Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Analyzing the Impact of System Reliability Events on Applications in the Titan Supercomputer

Extreme-scale computing systems employ Reliability, Availability and Serviceability (RAS) mechanisms and infrastructure to log events from multiple system components. In this paper, we analyze RAS logs in conjunction with the application placement and scheduling database, in order to understand the impact of common RAS events on application performance. This study conducted on the records of about 2 million applications executed on Titan supercomputer provides important insights for system users, operators and computer science researchers. Specifically, we investigate the impact of RAS events on application performance and its variability by comparing cases where events are recorded with corresponding cases where no events are recorded. Such a statistical investigation is possible since we observed that system users tend to execute their applications multiple times. Our analysis reveals that most RAS events do impact application performance, although not always. We also find that different system components affect application performance differently. In particular, our investigation includes the following components: parallel file system processor, memory, graphics processing units, system and user software issues. Our work establishes the importance of providing feedback to system users for increasing operational efficiency of extreme-scale systems.

Ashraf, Rizwan↗

DRIPS: Dynamic Rebalancing of Pipelined Streaming Applications on CGRAs

Coarse-grained reconfigurable arrays (CGRAs) provide higher flexibility than application-specific integrated circuits (ASICs) and higher efficiency than fine-grained reconfigurable devices such as Field Programmable Gate Arrays (FPGAs). However, CGRAs are generally designed to support offloading of a single kernel. While their design, based on communicating functional units, appears to naturally suit data streaming applications composed of multiple cooperating kernels, current approaches only statically partition the resources across application kernels. However, emerging streaming applications at the edge (scientific instruments, sensor networks, network processing) perform much more than digital signal processing and often are data and input dependent. This leads to extremely variable kernel execution times, severely impacting the throughput of the entire pipeline if resources are only statically allocated. Therefore, in this paper, we propose DRIPS — a coarse-grained, dynamically, and partially reconfigurable array for data-dependent streaming applications. We present a unified compiler framework to facilitate the mapping of a given streaming application onto the DRIPS CGRA architecture. The experimental results show that DRIPS achieves an average throughput improvement of 1.46$\times$ across a set of representative applications over a statically partitioned solution. The additional area overhead to enable dynamic rebalancing consumes 16.34% of the entire area for a 5x5 CGRA prototype.

Tan, Cheng↗

Balanced Coloring for Parallel Computing Applications

Graph coloring is used to identify subsets of independent tasks in parallel scientific computing applications. Traditional coloring heuristics aim to reduce the number of colors used as that number also corresponds to the number of parallel steps in the application. However, if the color classes produced have a skew in their sizes, utilization of hardware resources becomes inefficient, especially for the smaller color classes. Equitable coloring is a theoretical formulation of coloring that guarantees a perfect balance among color classes, and its practical relaxation is referred to as balanced coloring. In this paper, we revisit the problem of balanced coloring in the context of parallel computing. The goal is to achieve a balanced coloring of an input graph without increasing the number of colors that an algorithm oblivious to balance would have used. We propose and study multiple heuristics that aim to achieve such a balanced coloring, present parallelization approaches for multi-core and manycore architectures, and cross-evaluate their effectiveness with respect to the quality of balance achieved and performance. Furthermore, we study the impact of the proposed balanced coloring heuristics on a concrete application - viz. parallel community detection, which is an example of an irregular application. The thorough treatment of balanced coloring presented in this paper from algorithms to application is expected to serve as a valuable resource to parallel application developers who seek to improve parallel performance of their applications using coloring.

Balanced coloring, Tilera manycore architecture, c↗

Co-design for Particle Applications at Exascale

Co-design across the Exascale Computing Project (ECP) has been critical for both enabling science applications and bringing disparate communities together. Developing and porting applications to the various high-performance computing (HPC) architectures on pre-exascale and exascale computers has been quite challenging due to the diversity of hardware features and software stacks. The Co-design Center for Particle Applications (CoPA) has developed and enhanced the Cabana and PROGRESS/BML libraries to facilitate the creation of new particle applications, make existing particle applications exascale capable, and allow teams to explore new capabilities. Particle methods from atomistic, mesoscale, continuum, through cosmological scales have been built with Cabana, along with new possibilities for application coupling. Similarly, the PROGRESS/BML library has enabled quantum particle applications with linear algebra solvers to use advanced hardware. Across these CoPA-developed libraries, the co-design abstraction layer combines performance portability with math library support to facilitate separation of concerns and directly support science runs.

97 MATHEMATICS AND COMPUTING↗

Algorithms for Balanced Graph Colorings with Applications in Parallel Computing

Graph coloring is used to identify subsets of independent tasks in parallel scientific computing applications. Traditional coloring heuristics aim to reduce the number of colors used as that number also corresponds to the number of parallel steps in the application. However, if the color classes produced have a skew in their sizes, utilization of hardware resources becomes inefficient, especially for the smaller color classes. Equitable coloring is a theoretical formulation of coloring that guarantees a perfect balance among color classes, and its practical relaxation is referred to as balanced coloring. In this paper, we revisit the problem of balanced coloring in the context of parallel computing. The goal is to achieve a balanced coloring of an input graph without increasing the number of colors that an algorithm oblivious to balance would have used. We propose and study multiple heuristics that aim to achieve such a balanced coloring for two variants of coloring problem, distance-1 coloring and partial distance-2 coloring (defined on a bipartite graph). We present parallelization approaches for multi-core and manycore architectures, and cross-evaluate their effectiveness with respect to the quality of balance achieved and performance. Furthermore, we study the impact of the proposed balanced coloring heuristics on a concrete application - viz. parallel community detection, which is an example of an irregular application. In addition, we propose several extensions to our balancing schemes and evaluate their balancing efficacy and performance characteristics. The thorough treatment of balanced coloring presented in this paper from algorithms to application is expected to serve as a valuable resource to parallel application developers who seek to improve parallel performance of their applications using coloring.

graph coloring, multithreaded algorithms↗

SU-E-J-04: Integration of Interstitial High Intensity Therapeutic Ultrasound Applicators On a Clinical MRI-Guided High Intensity Focused Ultrasound Treatment Planning Software Platform

Purpose: Interstitial high intensity therapeutic ultrasound (HITU) applicators can be used to ablate tissue percutaneously, allowing for minimally-invasive treatment without ionizing radiation [1,2]. The purpose of this study was to evaluate the feasibility and usability of combining multielement interstitial HITU applicators with a clinical magnetic resonance imaging (MRI)-guided focused ultrasound software platform. Methods: The Sonalleve software platform (Philips Healthcare, Vantaa, Finland) combines anatomical MRI for target selection and multi-planar MRI thermometry to provide real-time temperature information. The MRI-compatible interstitial US applicators (Acoustic MedSystems, Savoy, IL, USA) had 1–4 cylindrical US elements, each 1 cm long with either 180° or 360° of active surface. Each applicator (4 Fr diameter, enclosed within a 13 Fr flexible catheter) was inserted into a tissue-mimicking agar-silica phantom. Degassed water was circulated around the transducers for cooling and coupling. Based on the location of the applicator, a virtual transducer overlay was added to the software to assist targeting and to allow automatic thermometry slice placement. The phantom was sonicated at 7 MHz for 5 minutes with 6–8 W of acoustic power for each element. MR thermometry data were collected during and after sonication. Results: Preliminary testing indicated that the applicator location could be identified in the planning images and the transducer locations predicted within 1 mm accuracy using the overlay. Ablation zones (thermal dose ≥ 240 CEM43) for 2 active, adjacent US elements ranged from 18 mm × 24 mm (width × length) to 25 mm × 25 mm for the 6 W and 8 W sonications, respectively. Conclusion: The combination of interstitial HITU applicators and this software platform holds promise for novel approaches in minimally-invasive MRI-guided therapy, especially when bony structures or air-filled cavities may preclude extracorporeal HIFU.[1] Diederich et al. IEEE UFFFC 46.5 (1999): 1218.[2] Chopra et al. PMB 50.21 (2005): 4957. Funding support was provided by Philips Healthcare and in-kind support from Acoustic MedSystems Inc. Ari Partanen is a paid employee of Philips Healthcare. Goutam Ghoshal and Everette Clif Burdette are paid employees of Acoustic MedSystems Inc.

60 APPLIED LIFE SCIENCES↗

Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model

Purpose: Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. Methods: Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. Results: Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and −3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4–40 mm long and 4–28 mm wide for the planar transducer applicator (1–13 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1–24 mm and 2–7 mm, respectively (1–7 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil’s coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5–7 W/cm{sup 2} applied intensity and 6–16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. Conclusions: This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.

60 APPLIED LIFE SCIENCES↗

SU-F-T-23: Correspondence Factor Correction Coefficient for Commissioning of Leipzig and Valencia Applicators with the Standard Imaging IVB 1000

Purpose: To determine the correction factor of the correspondence factor for the Standard Imaging IVB 1000 well chamber for commissioning of Elekta’s Leipzig and Valencia skin applicators. Methods: The Leipzig and Valencia applicators are designed to treat small skin lesions by collimating irradiation to the treatment area. Published output factors are used to calculate dose rates for clinical treatments. To validate onsite applicators, a correspondence factor (CFrev) is measured and compared to published values. The published CFrev is based on well chamber model SI HDR 1000 Plus. The CFrev is determined by correlating raw values of the source calibration setup (Rcal,raw) and values taken when each applicator is mounted on the same well chamber with an adapter (Rapp,raw). The CFrev is calculated by using the equation CFrev =Rapp,raw/Rcal,raw. The CFrev was measured for each applicator in both the SI HDR 1000 Plus and the SI IVB 1000. A correction factor, CFIVB for the SI IVB 1000 was determined by finding the ratio of CFrev (SI IVB 1000) and CFrev (SI HDR 1000 Plus). Results: The average correction factors at dwell position 1121 were found to be 1.073, 1.039, 1.209, 1.091, and 1.058 for the Valencia V2, Valencia V3, Leipzig H1, Leipzig H2, and Leipzig H3 respectively. There were no significant variations in the correction factor for dwell positions 1119 through 1121. Conclusion: By using the appropriate correction factor, the correspondence factors for the Leipzig and Valencia surface applicators can be validated with the Standard Imaging IVB 1000. This allows users to correlate their measurements with the Standard Imaging IVB 1000 to the published data. The correction factor is included in the equation for the CFrev as follows: CFrev= Rapp,raw/(CFIVB*Rcal,raw). Each individual applicator has its own correction factor, so care must be taken that the appropriate factor is used.

60 APPLIED LIFE SCIENCES↗

SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specified treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-07: Dosimetric Characterization of a New HDR Multi-Channel Esophageal Applicator for Brachytherapy

Purpose: To characterize the dose distribution of a new multi-channel esophageal applicator for brachytherapy HDR treatment, and particularly the effect of the presence of air or water in the applicator’s expansion balloon. Methods: A new multi-channel (6) inflatable applicator for esophageal HDR has been developed in house and tested in a simple water phantom. CT image sets were obtained under several balloon expansions (80ml of air, 50 cc of water), and channel loadings and used with the Oncentra (Elekta) planning system based on TG43 formalism. 400 cGy was prescribed to a plane 1cm away from the applicator. Planar dose distributions were measured for that plane and one next to the applicator using Gafchromic EBT3 film and scanned by a Vidar VXR-12 film digitizer. Film and TPS generated dose distributions of film were sent to OmniPro I’mRT (iba DOSIMETRY) for analysis. 2D dose profiles in both X and Y directions were compared and gamma analysis performed. Results: Film dose measurement of the air-inflated applicator is lower than the TPS calculated dose by as much as 60%. Only 80.8% of the pixels passed the gamma criteria (3%/3mm). For the water-inflated applicator, the measured film dose is fairly close to the TPS calculated dose (typically within <3%). 99.84% of the pixels passed the gamma criteria (3%/3mm). Conclusion: TG43 based calculations worked well when water was used in the expansion balloon. However, when air is present in that balloon, the neglect of heterogeneity corrections in the TG43 calculation results in large differences between calculated and measured doses. This could result in severe underdosing when used in a patient. This study illustrates the need for a TPS with an advanced algorithm which can account for heterogeneity. Supported by Innovations Department, Cleveland Clinic.

60 APPLIED LIFE SCIENCES↗

Design and testing of a phantom and instrumented gynecological applicator based on GaN dosimeter for use in high dose rate brachytherapy quality assurance

Purpose: High dose rate brachytherapy (HDR-BT) is widely used to treat gynecologic, anal, prostate, head, neck, and breast cancers. These treatments are typically administered in large dose per fraction (>5 Gy) and with high-gradient-dose-distributions, with serious consequences in case of a treatment delivery error (e.g., on dwell position and dwell time). Thus, quality assurance (QA) or quality control (QC) should be systematically and independently implemented. This paper describes the design and testing of a phantom and an instrumented gynecological applicator for pretreatment QA and in vivo QC, respectively. Methods: The authors have designed a HDR-BT phantom equipped with four GaN-based dosimeters. The authors have also instrumented a commercial multichannel HDR-BT gynecological applicator by rigid incorporation of four GaN-based dosimeters in four channels. Specific methods based on the four GaN dosimeter responses are proposed for accurate determination of dwell time and dwell position inside phantom or applicator. The phantom and the applicator have been tested for HDR-BT QA in routine over two different periods: 29 and 15 days, respectively. Measurements in dwell position and time are compared to the treatment plan. A modified position–time gamma index is used to monitor the quality of treatment delivery. Results: The HDR-BT phantom and the instrumented applicator have been used to determine more than 900 dwell positions over the different testing periods. The errors between the planned and measured dwell positions are 0.11 ± 0.70 mm (1σ) and 0.01 ± 0.42 mm (1σ), with the phantom and the applicator, respectively. The dwell time errors for these positions do not exhibit significant bias, with a standard deviation of less than 100 ms for both systems. The modified position–time gamma index sets a threshold, determining whether the treatment run passes or fails. The error detectability of their systems has been evaluated through tests on intentionally introduced error protocols. With a detection threshold of 0.7 mm, the error detection rate on dwell position is 22% at 0.5 mm, 96% at 1 mm, and 100% at and beyond 1.5 mm. On dwell time with a dwell time threshold of 0.1 s, it is 90% at 0.2 s and 100% at and beyond 0.3 s. Conclusions: The proposed HDR-BT phantom and instrumented applicator have been tested and their main characteristics have been evaluated. These systems perform unsupervised measurements and analysis without prior treatment plan information. They allow independent verification of dwell position and time with accuracy of measurements comparable with other similar systems reported in the literature.

60 APPLIED LIFE SCIENCES↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

Roll-up of validation results to a target application.

Suites of experiments are preformed over a validation hierarchy to test computational simulation models for complex applications. Experiments within the hierarchy can be performed at different conditions and configurations than those for an intended application, with each experiment testing only part of the physics relevant for the application. The purpose of the present work is to develop methodology to roll-up validation results to an application, and to assess the impact the validation hierarchy design has on the roll-up results. The roll-up is accomplished through the development of a meta-model that relates validation measurements throughout a hierarchy to the desired response quantities for the target application. The meta-model is developed using the computation simulation models for the experiments and the application. The meta-model approach is applied to a series of example transport problems that represent complete and incomplete coverage of the physics of the target application by the validation experiments.

Hills, Richard Guy↗

High Performance Computing Metrics to Enable Application-Platform Communication

Sandia has invested heavily in scientific/engineering application development and in the research, development, and deployment of large scale HPC platforms to support the computational needs of these applications. As application developers continually expand the capabilities of their software and spend more time on performance tuning of applications for these platforms, HPC platform resources are at a premium as they are a heavily shared resource serving the varied needs of many users. To ensure that the HPC platform resources are being used effciently and perform as designed, it is necessary to obtain reliable data on resource utilization that will allow us to investigate the occurrence, severity, and causes of performance-affecting contention between applications. The work presented in this paper was an initial step to determine if resource contention can be understood and minimized through monitoring, modeling, planning and infrastructure. This paper describes the set of metric definitions, identified in this research, that can be used as meaningful and potentially actionable indicators of performance-affecting contention between applications. These metrics were verified using the observed slowdown of IOR, IMB, and CTH in operating scenarios that forced contention. This paper also describes system/application monitoring activities that are critical to distilling vast amounts of data into quantities that hold the key to understanding for an application's performance under production conditions and that will ultimately aid in Sandia's efforts to succeed in extreme-scale computing.

97 MATHEMATICS AND COMPUTING↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks [Slides]

This presentation discusses Nuclear Criticality Safety (NCS) and how designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear experiments. The presentation poses the question of how this analysis can be performed and states that the answer lies in matching new nuclear experiments with existing benchmark experiments using similarity metrics. By increasing the criticality safety of the application in this work, higher mass limits could be used in PF-4 operations. Additionally, the presentation discusses MCNP6.2®, Whisper-1.1, the software that can be used in this analysis. Also discussed is the fact that International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks rarely match new nuclear applications and that there are significant differences in given set of materials and/or geometry. If there are no benchmarks that match the application, the presentation discusses the possibility of creating new benchmarks. In conclusion, this work presents a Gaussian process (GP) optimization scheme that was used to generate new benchmarks with the highest sensitivity-based similarity metrics to user-defined nuclear applications. The Gaussian process optimization successfully designed 3 new experimental benchmarks that were highly correlated to the application of interest and had k eff values near critical. Optimization over c k,i-r has shown that investigating specific isotope reactions for different applications is crucial to designing benchmark experiments. Partial contribution from Pu dominates c k similarity metric. Future work includes testing new stand-alone similarity metrics or new combinations of similarity metrics as the design criterion of this optimization – design criterion is application dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Large Scale Extrusion Deposition for Structural Applications

Large Scale Extrusion Deposition (LSED) is an evolving additive manufacturing (AM) technology that research, such as that taking place at Oak Ridge National Laboratory (ORNL) and companies like Local Motors, are continuing to utilize and develop new applications. A major LSED application of interest has been molds and tooling as it allows for much shorter production time and lower cost. However, interest has been expanding into using LSED for more structural applications due to more frequent use of high performing polymer composites as feedstock. The use of LSED for structural applications is of particular interest to Local Motors as it is currently being used to create commercially viable, energy efficient electric vehicles. LSED offers a unique opportunity when compared to traditional manufacturing methods as it can significantly reduce the number of components necessary, while decreasing embodied energy and carbon emissions. Even with these benefits however, it is important that LSED is properly understood from a structural aspect as this field has not been as heavily researched as tooling. To ensure a high level of safety and repeatability is an essential responsibility of a manufacturer whose products are structural in nature. As such it is important to understand the materials and LSED process to make structural objects that the manufacturer can be confident in. The main goals of this project were to: develop and investigate materials that are of interest for structural LSED applications, further develop and understand the current machines used in LSED and develop simulations tools of LSED and the mechanical properties of the created structure. Material development focused on composite materials that have high mechanical properties and are stable in a variety of environments. The materials were tested to determine their as printed mechanical and thermal properties as these are necessary for simulations. Once the materials were investigated thoroughly, it allowed for simulations to be performed to compare to experimental data with simulations. Materials were also vetted to determine candidates for multi-material printing. The machine development focused around the areas of process monitoring, non-destructive evaluation, and quality control. Finally, the goal of the simulations was to develop a realistic model of printed structures, including in-process simulation and dynamic simulation. The routes to get to some of these goals and the depth in which they were investigated changed throughout the project due to personnel changes and the COVID-19 pandemic. This project resulted in many valuable results such as the development of an nondestructive evaluation (NDE) technique for interlayer defects, proof of simulation for warpage in simple parts, the development and utilization of a profilometer to monitor a print for defects or inconsistencies, thorough investigation of a material used commercially for structural LSED applications and valuable experimental data on the applicability and advantages of multi-material crush structures versus their neat counterparts by creation and testing of samples.

36 MATERIALS SCIENCE↗

CEED-MS8:Initial Integration of CEED Software in ECP Applications

Key components of CEED software development involve fast finite element operator storage and evaluation, architecture optimizations, performant algorithms for all orders, global kernels for finite element operators, efficient use of the memory sub-system, optimal data locality and motion, enhanced scalability and parallelism, and fast tensor contractions. As ultimate goals of the project, CEED is exploring and identifying the best algorithms for the full range of discretizations and applying algorithmic and software development to support ECP applications’ needs. In this milestone we report on the initial integration of CEED software in the selected first-wave ECP/CEED apps and the continued exploration of other ECP applications as second-wave (milestone CEED-MS23) and third-wave (milestone CEED-MS35) ECP/CEED application candidates. An extensive evaluation of various approaches for GPU acceleration of the CEED computational motives is also a major focus of the report, both in the settings of CEED’s Nekbone and Laghos miniapps, as well as versions of CEED’s bake-off problems (introduced in milestone CEED-MS6). The first-wave ECP applications targeted for coupling with CEED software include the ExaSMR and MARBL applications. We also report on near-term collaboration with the seed-funded Urban Systems project, as well as engagements with ACME, ExaAM, GEOS and the Application Assessment and Proxy App projects. The ExaSMR project involves coupled thermal-hydraulics/neutronics, with the latter based on Monte Carlo methods and the former based on high-order discretizations of the Navier-Stokes and energy equations for accurate simulation of turbulent transport. The project requires fast and efficient turbulence simulation capabilities that will scale to exascale platforms. Work within CEED will ensure that all aspects of the Nek5000 workflow scale to the target problem space, which involves > 10 10 degrees of freedom in typical production runs. CEED’s goal is to provide implementations that perform with maximum attainable efficiency and deliver low turn-around times. A deliverable for this milestone is beta-release of the GPU-based variant of Nek5000. MARBL is targeting high-energy-density physics problems, including single fluid multi-material hydrodynamics and radiation/magnetic diffusion simulation, with applications in inertial confined fusion, pulsed power experiments, and equation of state/material strength analysis. The code uses high-order methods based arbitrary Lagrangian-Eulerian, direct Eulerian, and unstructured adaptive mesh refinement. A deliverable for this milestone is collaboration with MARBL for improved performance based on partially-assembled operators. The Urban exascale project is planning to couple real-time data with high performance simulations to study particulate transport in cities. Nek5000 will be used for large eddy and RANS (Reynolds-averaged Navier-Stokes) simulations of turbulent transport in these domains. Areas where the CEED team is aiding the Urban Canyon group include creating high-order meshes for urban geometries and developing boundary conditions appropriate for simulations close to real-life urban conditions. The software artifacts delivered as part of this milestone include GPU-enabled versions of the Nekbone and Laghos miniapps, which are provided through the CEED website, http://ceed.exascaleproject.org and the CEED GitHub organization, http://github.com/ceed. In addition to details and results from the above R&D efforts, in this document we are also reporting on other project-wide activities performed in Q4 of FY17, including: the CEED first annual meeting and participation of CEED researchers in a variety of outreach activities.

97 MATHEMATICS AND COMPUTING↗

Development of High-efficiency and Cost-effective Forged Ingot Niobium Technology for Science Frontiers and Accelerator Applications

Development of Forged Ingot Niobium Technology: Worlds science frontier programs and SRF accelerator applications demand high performance and cost-effective SRF accelerator technology [1-8]. Fine-grain (FG) and Large-grain (LG) ingot niobium technologies have been very well developed and implemented in all the present-day accelerator projects. However, forged ingot niobium technology which is the focus of this development proposal will be much more cost-effective and expected to have several technical advantages. FG niobium sheet production is very complex involving more than ten processing steps making them prone to contamination. As a result, they are very expensive to produce and require stringent QA procedure to be ready for SRF cavity production. The accelerating cavity process steps are also numerous and require strict procedures in order to achieve high accelerating gradients and quality factors needed for science frontier programs. LG niobium disc production, directly sliced from the ingot, is relatively simple and straight forward to keep surface cleanness. The disc production cost is significantly low compared to FG niobium sheet production. However, there are (some) draw backs due to non-homogeneity of the grain boundary distribution, resulting in non-uniform mechanical properties and complex cavity fabrication, although the LG cavities achieve the expected high-gradient performance goals with lower cost. Medium-grain (MG) niobium disk production may be realized with a new approach/process, the disc directly sliced from the forged ingot, involves a simpler process steps contributing major production cost reduction [9]. These discs are expected to be superior as they tend to be homogenous with uniform sub millimeter grains and mechanical properties. We are eagerly looking forward to developing the forged ingot niobium SRF accelerator technology for the benefit of the world-wide science frontier programs, green energy subcritical nuclear energy systems and a wide variety of industrial applications including the production of radio isotopes and nuclear transmutation applications. Measurement of thermal characteristics of the forged ingot niobium: Measurement of the thermal diffusivity, D, of superconducting MG niobium is important to be understood in comparison with FG sheet and LG disc, as well as that of advanced composite material of Nb3Sn film sputtered on forged ingot Nb, which will be determined using transient pump-probe thermo-modulation [10,11]. Transient thermo-modulation is based on using an ultrafast laser pulse to heat the superconducting materials by a few K, then a synchronized laser pulse probes the reflectance of the heated material. For thin films on a substrate (e.g, 100-nm Nb3Sn on Nb), it takes <100 ps for the heat to reach the substrate by diffusion. Therefore, an ultrafast method is needed to probe D of the studied material. D will be measured from room temperature to liquid helium temperatures. Fundamental Research: The increase of rf loss in SRF cavities is related to trapping of residual magnetic field during the cavity cool-down. The study suggested that the micro structure plays the role in flux trapping sensitivity. The research includes the flux trapping and expulsion study as forged ingot niobium goes through several mechanical deformations, crystallization leading to the optimal SRF cavity performance. Furthermore, the cavity made from FG, MG, and LG sheet/disc will be compared to understand the optimal re-crystallization temperature that cavity needed to be heat treated which minimize the flux trapping and increase SRF cavity performance. References: 1. S. Belomestnykh, Overview of recent SRF developments for ERLs, presented at the SRF 2015, Whistler, BC, Canada (2015). 2. A. Yamamoto, M. Yamanaka and G. Myneni, Ingot Nb based SRF Technology for the International Linear Collider, in Science and Technology of Ingot Niobium for Superconducting Radio Frequency Applications, AIP Conf. Proc. 1687, 030005-1 ? 03005-6, 2015 3. Report of the Workshop on Energy and Environmental Applications of Accelerators, DOE Workshop Report. https://science.osti.gov/-/media/hep/pdf/Reports/2020/CASM_WorkshopReport.pdf? la=en&hash=AEB0B318ED0436B1C5FF4EE0FDD6DEB84C2F15B2 4. G. Ciovati, et al., Design of a cw, low-energy, high-power superconducting linac for environmental applications, Phys. Rev. Accel. Beams 21, 091601 (2018). 5. P. Dhakal, et al., Effect of high temperature heat treatments on the quality factor of a large-grain superconducting radio-frequency niobium cavity, Phys. Rev. ST Accel. Beams 16, 042001 (2013). 6. P. Kneisel et al., Review of ingot niobium as a material for superconducting radio frequency accelerating cavities, Nuclear Instruments and Methods in Physics Research A 774, 133 (2015). 7. G. Ciovati, P. Dhakal, and G. R, Myneni, Superconducting radio-frequency cavities made from medium and low-purity niobium ingots, Supercond. Sci. Technol. 29, 064002 (2016). 8. M. Drury et al., commissioning of the prototype C75 cavities in a CEBAF cryomodule, in Proc. of IPAC 2018, Vancouver, BC, Canada (2018) 9. Feasibility of forged-ingot niobium disc and SRF cavity fabrication technology recently demonstrated in cooperation of ATI, BSCE, and KEK (2020). 10. Hani E. Elsayed-Ali, ?Measurements of heat transport in thin films by ultrafast laser-based techniques,? 3rd International Conference on Thermal Issues in Emerging Technologies Theory and Applications, Cairo, Egypt, pp. 347 ? 350 (2010). DOI: 10.1109/ThETA17616.2010 11. W. M. G. Ibrahim, H. E. Elsayed-Ali, M. Schinn, and C. A. Bonner, Jr., ?Ultrafast investigation of electron dynamics in multilayer metals,? Int. J. Heat and Mass Transfer, 47(10?11), 2261?2268 (2004).

Myneni, G.↗