Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Apertures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Coherent Mode Decomposition for Kolmogorov Optical Turbulence in a Finite Aperture

An analysis of the coherent mode decomposition of an optical field after propagation through atmospheric turbulence is presented. The coherent modes represent an ideal basis by which to decompose the field for design of mode-limited optical systems. Using the rotational symmetry of the Fredholm integral operator for Kolmogorov optical turbulence, it is shown that the coherent modes exhibit separable solutions classified by radial and azimuthal quantum numbers. The study of the coherent modes is then reduced that of the radial functions determined by the aperture-coherence diameter ratio and obscuration ratio. Analysis of the spectrum of eigenvalues yields sharp bounds on the efficiency of receivers using incoherent or coherent combining with mode-limited photonic devices in the presence of Kolmogorov turbulence. The effective number of modes needed to represent Kolmogorov optical turbulence is studied via the von Neumann entropy, purity, and largest eigenvalue, and the differences in the different definitions is discussed. The similarity of the coherent modes to linearly polarized (LP) fiber modes is quantified yielding a precise characterization of the maximum gain that can be achieved in mode-limited systems via mode shaping techniques. As a final application, a mode sorting technique is presented for optimally splitting power from atmospherically degraded light into a finite number of modes simultaneously maximizing total coupling efficiency and minimizing the average and instantaneous power ratio between channels.

free-space optical communication↗

Solar System Science With the Single Aperture Large Telescope for Universe Studies Space Observatory

Single Aperture Large Telescope for Universe Studies (SALTUS) is a NASA Astrophysics Probe Explorer (APEX)-class mission concept employing a robust far-infrared pointed space observatory. SALTUS comprises a 14-m inflatable reflector that provides 16× the sensitivity and 4× the angular resolution of Herschel, with a sunshield that radiatively cools the primary to 45 K, along with cryogenic detectors that collectively span the 34 to 660 μm far-infrared spectral range at high and moderate spectral resolutions. The high sensitivity and high spectral resolving power of the SALTUS heterodyne receivers enable both submillimeter and far-infrared observations of trace compounds comprising water and its isotopologues, hydrogen deuteride (HD), and a plethora of molecular species containing carbon, hydrogen, nitrogen, oxygen, phosphorus, or sulfur (CHNOPS), all of which are obscured by the Earth’s atmosphere. The high sensitivity and broadband spectral coverage of the SALTUS far-infrared grating spectrometer enables far-infrared observations of the lattice vibrational spectral signatures of ices and mineral grains contained within a wide variety of solar system targets, including comets, planetary atmospheres, near Enceladus’ plumes, and on the surfaces of icy moons, Jupiter trojans, centaurs, and Kuiper Belt objects. A key objective of SALTUS is to measure HDO∕H 2 O in both Jupiter family and Oort cloud comets. Additional observations will allow us to characterize the water torus around Saturn generated by its icy moon Enceladus, determine the source of stratospheric water in the giant planets, ascertain the time evolution of water on Venus, and search for H 2 O plumes on Europa, Ganymede, and Callisto. SALTUS will measure HD∕H 2 in all four giant planets to constrain models of their origin. SALTUS can also measure the abundance of CHNOPS-containing molecules and halides in the atmosphere of Venus and in the comae of comets. We review the extensive amount of solar system science achievable with SALTUS for both the Guaranteed Time Observation and the Guest Observer APEX mission observing programs.

Carrie M. Anderson↗

Commercial Synthetic Aperture Radar Data for Surface Deformation and Change

The commercial synthetic aperture radar (SAR) market is experiencing year-over-year growth and is currently capable of imaging anywhere in the world within an hour at X-band. Surface Deformation and Change (SDC) is a mission study at NASA to investigate innovative architectures beyond the NASA-ISRO SAR (NISAR) mission in the next decade. In this article we present preliminary findings on the technical capabilities of the currently available commercial SAR data, and investigate their applicability to SDC goals, such as imaging quality and retrieval of surface motion.

SAR↗

Apparatus, system and method for highlighting activity-induced change in multi-pass synthetic aperture radar imagery

Described herein are various technologies relating to constructing a differenced change product (DCP) image. A plurality of synthetic aperture radar (SAR) images of a scene are generated based upon radar signals directed towards and reflected off of the scene, and a plurality of coherence change detection (CCD) images of the scene are generated based upon the SAR images. The CCD images are registered with one another, and their pixel values re-scaled according to a monotonic mapping function. The DCP image is generated based upon a computed pixel-wise difference between a pair of the re-scaled CCD images. The DCP image identifies locations in the scene where human activity-induced change is likely to have occurred between a pair of SAR passes of the scene.

42 ENGINEERING↗

The Simons Observatory: Modeling Optical Systematics in the Large Aperture Telescope

We present geometrical and physical optics simulation results for the Simons Observatory Large Aperture Telescope. This work was developed as part of the general design process for the telescope; allowing us to evaluate the impact of various design choices on performance metrics and potential systematic effects. The primary goal of the simulations was to evaluate the final design of the reflectors and the cold optics which are now being built. We describe non-sequential ray tracing used to inform the design of the cold optics, including absorbers internal to each optics tube. We discuss ray tracing simulations of the telescope structure that allow us to determine geometries that minimize detector loading and mitigate spurious near-field effects that have not been resolved by the internal baffling. We also describe physical optics simulations, performed over a range of frequencies and field locations, that produce estimates of monochromatic far field beam patterns which in turn are used to gauge general optical performance. Finally, we describe simulations that shed light on beam sidelobes from panel gap diffraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Holdup Determinations Using Coded-Aperture Gamma-Ray Imaging

Passive gamma-ray imaging can be used to create images of distributed nuclear materials. Inherently quantitative, the images provide a means to directly determine the amount of nuclear material in the imager’s field of view. However, to take advantage of quantitative imaging, one must correct for changes to the imager’s efficiency across the image. This paper presents work on detailed calibration of a coded-aperture imager based on a portable, mechanically cooled, high-purity germanium detector. This enables the use of gamma-ray imaging as a tool to determine nuclear holdup. By applying the calibrations to images of small amounts of distributed 235U, quantity estimates within a few percent of the actual amounts present were obtained, validating the approach.

Ziock, Klaus-Peter↗

Overview of the Optical Design of the CMB-S4 Large Aperture Telescopes and Camera Optics

CMB-S4, the next-generation CMB observatory, will deploy hundreds of thousands of detectors to enable mapping the millimeter-wavelength sky with unprecedented speed. The large aperture telescopes for CMB-S4 consist of six-meter diameter crossed Dragone designs and a five-meter diameter three-mirror anastigmat. The two-mirror crossed Dragone design requires astigmatism corrections in the refractive optics to achieve diffraction-limited performance. We present biconic lens corrections for the CMB-S4 crossed Dragone camera optics and compare these designs to the camera optics for the three mirror anastigmat, as the optical designs of the cameras for these telescopes are being prototyped.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Whole-scene, one-sided backscatter x-ray imaging with coded apertures

X-ray radiography can be an important diagnostic for emergency response, providing timely diagnostic information about a suspect object. However, there are situations where similar information would be better obtained with a one-sided imaging technique. X-ray backscatter imaging is a proven technology that could provide such information, but current implementations have drawbacks that render it unsuitable for emergency response. We are exploring the use of coded-aperture imaging to create one-sided images, targeting a key benefit: implementation requiring minimal additional resources, bypassing logistics issues. We present results demonstrating the feasibility of this approach.

Ziock, Klaus-Peter [ORNL]↗

The NASA Airborne Synthetic Aperture Radar System

None given. (From introduction): ...we will briefly describe the instrument characteristics, the evolution of the various radar modes, the instrument performance and improvement in the knowledge of the positioning and attitude information of the radar. In addition, we will summarize the [rogress of the data processing effort, especially in the interferometry processing. Finally, we will address the issue of processing and calibrating the cross-track interferometry (XTI) data.

radar radar↗

Large aperture and durable glass-engraved optical metasurfaces using nanoparticle etching masks: prospects and future directions

Abstract Metasurfaces (MSs), or surfaces consisting of engineered spatially oriented sub-wavelength elements—also known as meta-atoms—are quickly becoming a burgeoning field of interest due to their seemingly unparalleled control over the propagation of light. This article will discuss the emergence of a MS technology that is based on dewetting thin metal films to form dry etching masks for MS fabrication. The novelty this process presents is the ability to spatially vary mask features—which translates into spatially varying index of the finished surface—in a way that, rather than writing subwavelength elements one-by-one, writes entire areas at once to provide a route to easily scale the process up to meter-sized optics. Glass-engraved MSs have shown to be laser damage resistant, with damage thresholds close to the parent substrate damage thresholds. Furthermore, these surfaces have proven to be mechanically durable and capable of handling normal loads two orders of magnitude higher than that of an average fingerprint pressure. This indicates that accidental handling contact is not detrimental to the MS optical performance. Also discussed are the foreseeable technological challenges, potential solutions for those obstacles, and some currently unexplored directions for future efforts.

47 OTHER INSTRUMENTATION↗

Design of B1pF-A Large Aperture Dipole Magnet for EIC

The design of interaction region (IR) magnets for the Electron Ion Collider (EIC), demands tight boundary conditions on the magnet design given by the high field requirements and the proximity of electron and hadron beams within a common yoke and resultant crosstalk. Here, this article discusses the electromagnetic design of the superconducting collared magnet B1pF. The magnet will be built as the prototype for several collared magnets (dipoles and quadrupoles) for the hadron beam in the forward direction of the IR. The magnet design is based on a single layer coil with an inner diameter of 300 mm over a slot length of 3 m. The magnet produces an integral field of 10.34 T.m at a current of 11.9 kA to produce a nominal field of about 3.96 T at its center. Given by the common Rutherford cable parameters, the magnet will be used as a baseline for optimization of all the collared magnets. The article further discusses yoke optimizations, quench analysis, coil end design and efforts on fine tuning of field quality.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗