Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ambient Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Alternative Setup for Long-Duration Low-Duty-Cycle 600°C Ambient Testing of SiC Integrated Circuits

A scalable, compact oven testbed system for simultaneously evaluating a multitude of high temperature integrated circuits (ICs) for prolonged operating times of up to 600 °C has been prototyped. The new testbed system enables long-duration high temperature testing in sufficient statistical quantities consistent with standard aerospace electronics engineering standards. This setup is comprised of multiple compact ovens housing chips or packages mounted to ceramic circuit boards. Each oven is a compact 15.2 cm length by 15.2 cm width by 12.7 cm depth with a maximum 400 Watts of heating power. The custom-made silicon oxide ceramic heating block inside each oven is based on a 3D printed design adapted for the easy insertion of the IC device under test (DUT). This innovative design provides the quick insertion of ICs with or without a ceramic package into a 600 °C environment by utilizing a movable 11.43 cm long ceramic substrate with electrical traces extending from the oven hot zone to external standard plastic-based board connectors. Another key oven design feature is the minimization of the DUT exposure to electromagnetic interference (EMI) by utilizing a filtered DC power source to reduce heating element noise. Additionally, the ovens can be configured in a parallel arrangement allowing global data monitoring over a single industrial RS422 serial port. This feature is important for scaling up to test multiple ICs semi-simultaneously. A USB serial port is provided to independently control the operating parameters of each oven such as the oven target temperature and oven ramp rate. The oven temperature can reach up to 600 °C with a confirmed +/- 4 °C maximum deviation across the test zone region. The ramp rate can be programmed from 1 °C/minute up to 10 °C/minute. Furthermore, a programmable switchboard is used to interface with the DUT. This switchboard comprises a National Instruments Peripheral Component Interconnect eXtension for Instrumentation (NI PXI) system and a breakout board to send and receive power, analog or digital test signals. By using this unique oven testbed system, a variety of ICs can now be tested in parallel using the same test components configured for a diverse set of requirements.

DC Powered Oven↗

The LDCE Particle Impact Experiment as flown on STS-46

Many materials and techniques have been developed by the authors to sample the flux of particles in Low Earth Orbit (LEO). Though regular in-site sampling of the flux in LEO the materials and techniques have produced data which compliment the data now being amassed by the Long Duration Exposure Facility (LDEF) research activities. Orbital debris models have not been able to describe the flux of particles with d sub p less than or = 0.05 cm, because of the lack of data. Even though LDEF will provide a much needed baseline flux measurement, the continuous monitoring of micron and sub-micron size particles must be carried out. A flight experiment was conducted on the Space Shuttle as part of the LDCE payload to develop an understanding of the Spatial Density (concentration) as a function of size (mass) for particle sizes 1 x 10(exp 6) cm and larger. In addition to the enumeration of particle impacts, it is the intent of the experiment that hypervelocity particles be captured and returned intact. Measurements will be performed post flight to determine the flux density, diameters, and subsequent effects on various optical, thermal control and structural materials. In addition to these principal measurements, the Particle Impact Experiment (PIE) also provides a structure and sample holders for the exposure of passive material samples to the space environment, e.g., thermal cycling, and atomic oxygen, etc. The experiment will measure the optical property changes of mirrors and will provide the fluence of the ambient atomic oxygen environment to other payload experimenters. In order to augment the amount of material returned in a form which can be analyzed, the survivability of the experiment as well as the captured particles will be assessed. Using Sandia National Laboratory's hydrodynamic computer code CTH, hypervelocity impacts on the materials which comprise the experiments have been investigated and the progress of these studies are reported.

Maag, Carl R.↗

Pt/HTCC Alumina based Electronic Packaging System and Integration Processes for High Temperature Harsh Environment Applications

Electronic devices capable of operation at 500°C are required for long term Venus surface missions, as well as for in situ monitoring and control of next generation aeronautical engines. High temperature sensors and electronics can also find many applications in military, and energy and automobile industries. Various silicon carbide (SiC) sensors and electronic devices have been developed for operation at 500 °C, and a compatible packaging system is needed for long term test and deployment of these high temperature devices. High temperature co-fired ceramics (HTCC) alumina with platinum (Pt) conductor was proposed for high temperature electronic packaging. A prototype Pt/HTCC alumina packaging system including chip-level package and circuit board has been briefly reported previously for long-term electrical testing of SiC integrated circuits at 500 °C, and brief testing at much higher temperatures. HTCC alumina is an excellent dielectric material with acceptable dielectric constant and low dielectric loss over wide temperature and frequency ranges. Pt is chemically noble and can be co-fired with HTCC alumina in air ambient producing a viable electronic packaging material system for high temperature applications. This paper presents a more detailed description of this packaging system including prototype low power packages and circuit boards based on HTCC alumina and Pt metallization for 500°C and other harsh environment applications. The key technical considerations for chip-level packaging and circuit board assembly, including materials and processes for 500 °C durable wire-bonding and SiC die attach, and integration of multi-chip circuit boards, are presented. Experimental test results of this packaging approach applied to SiC integrated circuits at 500 °C and 700°C are discussed as well.

High temperature↗

Pt/HTCC Alumina based Electronic Packaging System and Integration Processes for High Temperature Harsh Environment Applications

Electronic devices capable of operation at 500°C are required for long term Venus surface missions, as well as for in situ monitoring and control of next generation aeronautical engines. High temperature sensors and electronics can also find many applications in military, and energy and automobile industries. Various silicon carbide (SiC) sensors and electronic devices have been developed for operation at 500 °C, and a compatible packaging system is needed for long term test and deployment of these high temperature devices. High temperature co-fired ceramics (HTCC) alumina with platinum (Pt) conductor was proposed for high temperature electronic packaging. A prototype Pt/HTCC alumina packaging system including chip-level package and circuit board has been briefly reported previously for long-term electrical testing of SiC integrated circuits at 500 °C, and brief testing at much higher temperatures. HTCC alumina is an excellent dielectric material with acceptable dielectric constant and low dielectric loss over wide temperature and frequency ranges. Pt is chemically noble and can be co-fired with HTCC alumina in air ambient producing a viable electronic packaging material system for high temperature applications. This paper presents a more detailed description of this packaging system including prototype low power packages and circuit boards based on HTCC alumina and Pt metallization for 500°C and other harsh environment applications. The key technical considerations for chip-level packaging and circuit board assembly, including materials and processes for 500 °C durable wire-bonding and SiC die attach, and integration of multi-chip circuit boards, are presented. Experimental test results of this packaging approach applied to SiC integrated circuits at 500 °C and 700°C are discussed as well.

electronic packaging↗

Impact of nitrate-enhanced leachate recirculation on gaseous releases from a landfill bioreactor cell

This study evaluates the impact of nitrate injection on a full scale landfill bioreactor through the monitoring of gaseous releases and particularly N{sub 2}O emissions. During several weeks, we monitored gas concentrations in the landfill gas collection system as well as surface gas releases with a series of seven static chambers. These devices were directly connected to a gas chromatograph coupled to a flame ionisation detector and an electron capture detector (GC-FID/ECD) placed directly on the field. Measurements were performed before, during and after recirculation of raw leachate and nitrate-enhanced leachate. Raw leachate recirculation did not have a significant effect on the biogas concentrations (CO{sub 2}, CH{sub 4} and N{sub 2}O) in the gas extraction network. However, nitrate-enhanced leachate recirculation induced a marked increase of the N{sub 2}O concentrations in the gas collected from the recirculation trench (100-fold increase from 0.2 ppm to 23 ppm). In the common gas collection system however, this N{sub 2}O increase was no more detectable because of dilution by gas coming from other cells or ambient air intrusion. Surface releases through the temporary cover were characterized by a large spatial and temporal variability. One automated chamber gave limited standard errors over each experimental period for N{sub 2}O releases: 8.1 {+-} 0.16 mg m{sup -2} d{sup -1} (n = 384), 4.2 {+-} 0.14 mg m{sup -2} d{sup -1} (n = 132) and 1.9 {+-} 0.10 mg m{sup -2} d{sup -1} (n = 49), during, after raw leachate and nitrate-enhanced leachate recirculation, respectively. No clear correlation between N{sub 2}O gaseous surface releases and recirculation events were evidenced. Estimated N{sub 2}O fluxes remained in the lower range of what is reported in the literature for landfill covers, even after nitrate injection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oh! I Slipped the Surly Bounds of Earth....and Ran into Space Weather!

Over the past decade the concept of space weather has been introduced and matured in both the scientific community and popular press. Likewise the concept of space climatology recently also is being advanced. Closely linked to these concepts are their impacts on ground- and space-based technological systems; one such system commonly mentioned is manned space flight exemplified by the Space Shuttle and International Space Station (ISS). From a manned space flight perspective, space weather and space climatology have significant effects on the amount of radiation exposure received by humans in space from the ambient high-energy charged particles present in interplanetary space and trapped in the geomagnetosphere. Whereas the impact of space weather for most technological systems is usually discrete and well correlated in time, the principle impact of space weather and space climatology is to increase the probability of latent cancer formation in thetraveler cohort. In this regard, while space weather may be the dominating factor for a given mission, over the life of a long-term program such as the Space Shuttle or ISS space climatology is the controlling factor of latent cancer risk. Human radiation exposure enhancements associated with space weather disturbances has been a concern among scientist and mission controllers since the inception of manned spaceflight nearly forty years ago. This led NASA to develop, in conjunction with the Environmental Science Services Administration s Space Disturbance Forecast Center and the USAF/AWS, the Solar Particle Alert Network (SPAN)-the foundation of an initial U.S. space weather monitoring and forecasting service. Since Apollo, routine space flight operations have evolved to include the use of space weather and climatology data provided through a world-wide network of operational space weather data services to predict and recommend actions to minimize astronaut radiation exposures. NASA Space Radiation Analysis Group (SRAG) flight controllers use real-time space weather data to detect and assess the impact of solar particle events, outer electron belt enhancements, the formation of pseudo-stable additional trapped radiation belts, and the solar cycle modulation of trapped radiation belts and galactic cosmic rays. Energetic particle data from GOES spacecraft are automatically ingested from NOAA Space Environment Center data servers and used to drive a model for the estimating the exposure to astronauts from solar particle events. While adequate for current manned space flight support, the existing operational space weather support system requires improvements to address the anticipated evolution in both the character of manned missions as well as space flight operations management. Necessary space weather data improvements include: reliably available (near) real-time space weather data on a fixed schedule via redundant access methods that support autonomous data acquisition by computer systems behind enterprise firewalls; and rapid transition of promising research sensors into operational systems.

Golightly, Michael J.↗

Monitoring phase behavior of hydrogen confined in carbon nanopores by in-situ small angle neutron scattering technique

We report on the use of in-situ small angle neutron scattering (SANS) technique to study the phase behavior of hydrogen confined in narrow pores of ultramicroporous carbon (UMC) with a very large surface area (2630 m2/g) and pore volume (1.3 cm3/g). The effect of pore size and pressure on hydrogen adsorbed on UMC at room temperature and pressures up to ~200 bar were investigated. In a previous experiment, we have measured the density of adsorbed H2 gas in the nanopores and mesopores of polyfurfuryl alcohol-derived activated carbon (PFAC) by SANS techniques. Here, a comparative SANS study between the UMC and PFAC was conducted in order to further investigate the densification of H2 as a function of pore size and pressure. Initial results suggest that the density of confined H2 in both UMC and PFAC is considerably higher than that of the bulk hydrogen gas. The density is systematically higher in the narrow pores and decreases with increasing pore size. These results clearly demonstrate the advantage of adsorptive storage over compressed gas storage and emphasize the greater efficiency of micropores over mesopores in the adsorption process, which can be used to guide the development of new carbon adsorbents tailored for maximum H2 storage capacities at near-ambient temperatures.

adsorption↗

Evolution of lower hybrid turbulence in the ionosphere

Three-dimensional evolution of the lower hybrid turbulence driven by a spatially localized ion ring beam perpendicular to the ambient magnetic field in space plasmas is analyzed. It is shown that the quasi-linear saturation model breaks down when the nonlinear rate of scattering by thermal electron is larger than linear damping rates, which can occur even for low wave amplitudes. The evolution is found to be essentially a three-dimensional phenomenon, which cannot be accurately explained by two-dimensional simulations. An important feature missed in previous studies of this phenomenon is the nonlinear conversion of electrostatic lower hybrid waves into electromagnetic whistler and magnetosonic waves and the consequent energy loss due to radiation from the source region. This can result in unique low-amplitude saturation with extended saturation time. It is shown that when the nonlinear effects are considered the net energy that can be permanently extracted from the ring beam is larger. The results are applied to anticipate the outcome of a planned experiment that will seed lower hybrid turbulence in the ionosphere and monitor its evolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermally Conductive Backsheets (TCB) for Reduced Operating Temperatures

The performance of photovoltaic (PV) modules is primarily influenced by the plane of array (POA) irradiance and their operating temperature. The lower the module operating temperature, the higher is its performance. Increasing a module’s operating temperature reduces its power output due to an increase in the semiconductor’s intrinsic carrier density, leading to a reduction in the open-circuit voltage and, subsequently, reducing the maximum power point voltage. Reducing the operating temperature lowers the levelized cost of energy (LCOE) via increased energy production (i.e., more kilowatt hour over the life of the asset) and increased service lifetime (years in the field). The module operating temperature is dictated by the weather parameters and the thermal properties of module construction materials. The primary weather parameters influencing the PV module temperature are: the ambient temperature (directly related), irradiance (directly related), and wind speed (inversely related). The primary thermal properties of module construction materials influencing the PV module temperature are: the optical transmissivity and thermal conductivity of superstrate, the thermal conductivity of substrate, the thermal conductivity of encapsulant and the efficiency of the encapsulated solar cells. The primary goal of this study is to reduce the operating temperature of PV modules using thermally conductive backsheet (TCB) substrates developed by the industry. The temperature of PV modules installed in a large multi-MW plant can also be influenced by their physical locations in the plants due to the influence of wind direction. A thermal mapping of PV plants has also been investigated and presented in this study. The most commonly used PV backsheet material has been polyvinyl fluoride (DuPont trade name “Tedlar”)-based backsheet, which typically has three layers: Tedlar–polyethylene terephthalate (PET)–Tedlar (TPT). The primary goal of this project is to reduce the module operating temperature below the benchmark TPT backsheet temperature using newly developed TCBs by the industry. The overall approach of this project involves six focus areas: i) select and procure one TPT and thirteen promising TCBs available in the industry; ii) construct a large number of 1-cell and 9-cell modules using benchmark TPT and selected TCBs [all other construction materials are fixed and they are: glass superstrate, EVA encapsulant, mono-Si cell and junction box]; iii) to identify best performing TCBs, monitor the long-term field operating temperatures of the constructed modules which are installed in three climatic conditions (hot-low wind [Mesa, AZ], hot-high wind [Maricopa County, AZ] and temperate [Cumberland County, NC]; iv) to identify the most durable TCB, perform extended accelerated reliability testing of modules constructed with best three TCBs and benchmark TPT; v) to predict module temperature, develop physical and empirical thermal models with and without thermal properties of all construction materials in the modules, respectively; and vi) to determine the influence of wind speed and direction on the module operating temperature in a plant, and perform thermal mapping of PV modules in two large PV plants [Maricopa County, AZ and Cumberland County, NC]. The key achievements of this project are listed below: Backsheet selection: 14 backsheets were procured after an extensive literature and industry search. Finally, based on the thermal and other selection criteria, 1 TPT and 4 thermally conductive backsheets were selected for this project. Fabrication of mini modules: 50 one-cell modules were fabricated in year 1 for thermal performance evaluation. The module design was changed to nine-cell module at start of year 2 to mimic commercial design. 20 nine-cell modules were fabricated in year 2 for thermal performance evaluation. 28 four-cell modules were fabricated in year 3 for accelerated stress-testing. Thermal conductivity of backsheets: Year 1 TCBs showed at least 8% higher thermal conductivities than TPT. Year 2 and 3 TCBs showed at least 20% higher thermal conductivities than TPT. Installation of mini PV modules at three sites: 6 one-cell modules and 8 nine-cell modules were installed at AZ-1 site [Mesa, AZ]. 12 one-cell modules and 6 nine-cell modules were installed at each of two powerplants (AZ-2 [Maricopa County, AZ] and NC sites). Nominal operating cell temperatures (NOCT) of mini PV modules: NOCT of TCBs were observed to be lower than TPT with differences as high as 2°C. Comparison of thermal performance: The median operating temperature of one-cell modules was found to be reduced by 2°C by using TCB_A modules compared to TPT modules on several days in a month for few months in a year. The median temperature improvement of 4oC was achieved at several instances on a few days, but not all days, in a year using multiple TCBs compared to TPT. The final project milestone of achieving median temperature improvement of 5oC was achieved at several instances on a few days, but not all days, in a year using TCB_A compared to TPT. Empirical thermal model (without the need of construction material properties): Empirical thermal model for one-cell module was developed based on the input data of irradiance, wind speed and ambient temperatures. The primary input data differentiator for temperature differences between TPT and TCBs appears to be the irradiance level (solar gain). Accelerated durability testing: 20 four-cell modules using 4 backsheets (1 TPT and 3 TCBs) were exposed to Damp Heat 1000 hours (8 modules), UV/Thermal cycling (50 cycles)/Humidity freeze (10 cycles) test sequence (8 modules) and UV Weathering for qualification (8 modules). All the modules with four selected backsheets passed the stress tests per the retest guidelines of IEC 61215 standard for the backsheet change. Simplified comparative LCOE analysis: Using backsheet-specific power degradation levels in the accelerated tests (for TCB_A and TPT only), efficiency, service lifetime and assuming same cost for all backsheets, the LCOE of modules using TCB_A is determined to be lower than TPT. Due to lower operating temperature of TCB_A-based modules compared to TPT-based modules, the operating efficiency and service life of TCB_A-based modules are calculated to be higher than TPT-based modules. Temperature mapping of PV power plants: A distinct temperature difference (as high as 4°C) has been observed between the modules located in various parts of a single PV plant.

14 SOLAR ENERGY↗

A comprehensive analysis of transient pressure and rate data from CO 2 storage projects in a depleted pinnacle reef oil field complex, Michigan, USA

Pressure and rate data are commonly recorded as part of a basic monitoring program in CCS projects. This paper discusses the application of multiple analytical techniques to interpret pressure and rate transient data from CO 2 injection and storage operations. The techniques of interest, i.e., injection-falloff analysis, injectivity/productivity index analysis and pressure pulse arrival time analysis, are commonly used in the oil and gas industry to assess reservoir properties, but not well known in the CCS literature (especially the last two). Injection-falloff analysis involves log-log pressure derivative plotting for the falloff data and history-matching of the entire injection-falloff sequence to determine permeability. In the injectivity/productivity index analysis, rate-normalized pressure buildup is plotted against material balance time or ratio of cumulative injection to injection rate to determine the injectivity index (ratio of injection rate to stabilized pressure buildup) which can be related to the permeability-thickness product. The arrival time analysis identifies the arrival of a pressure disturbance (~0.1 psi change from ambient) to determine the hydraulic diffusivity from which permeability can be estimated. The applicability of these techniques is demonstrated via illustrative examples from multiple wells in different pinnacle carbonate reefs undergoing CO 2 -EOR in Northern Michigan. The paper ends with a discussion of the relative merits of each interpretive technique, as well as recommendations that could be useful for other field projects.

42 ENGINEERING↗

Phenols and hydroxy-PAHs (arylphenols) as tracers for coal smoke particulate matter: source tests and ambient aerosol assessments

Source tests were conducted to analyze and characterize diagnostic key tracers for emissions from burning of coals with various ranks. Coal samples included lignite from Germany, semibituminous coal from Arizona, USA, bituminous coal from Wales, UK and sample from briquettes of semibituminous coal, bituminous coal and anthracite from China. Ambient aerosol particulate matter was also collected in three areas of China and a background area in Corvallis, OR (U.S.) to confirm the presence of tracers specific for coal smoke. The results showed a series of aliphatic and aromatic hydrocarbons and phenolic compounds, including PAHs and hydroxy-PAHs as the major tracers, as well as a significant unresolved complex mixture (UCM) of compounds. The tracers that were found characteristic of coal combustion processes included hydroxy-PAHs and PAHs. Atmospheric ambient samples from Beijing and Taiyuan, cities where coal is burned in northern China, revealed that the hydroxy-PAH tracers were present during the wintertime, but not in cities where coal is not commonly used (e.g., Guangzhou, South China). Thus, the mass of hydroxy-PAHs can be apportioned to coal smoke and the source strength modeled by summing the proportional contents of EC (elemental carbon), PAHs, UCM and alkanes with the hydroxy-PAHs. 36 refs., 2 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Quantifying energy and mass transfer in crop canopies: sensors for measurement of temperature and air velocity

Here we report on the in situ performance of inexpensive, miniature sensors that have increased our ability to measure mass and energy fluxes from plant canopies in controlled environments: 1. Surface temperature. Canopy temperature measurements indicate changes in stomatal aperture and thus latent and sensible heat fluxes. Infrared transducers from two manufacturers (Exergen Corporation, Newton, MA; and Everest Interscience, Tucson, AZ, USA) have recently become available. Transducer accuracy matched that of a more expensive hand-held infrared thermometer. 2. Air velocity varies above and within plant canopies and is an important component in mass and energy transfer models. We tested commercially-available needle, heat-transfer anemometers (1 x 50 mm cylinder) that consist of a fine-wire thermocouple and a heater inside a hypodermic needle. The needle is heated and wind speed determined from the temperature rise above ambient. These sensors are particularly useful in measuring the low wind speeds found within plant canopies. 3. Accurate measurements of air temperature adjacent to plant leaves facilitates transport phenomena modeling. We quantified the effect of radiation and air velocity on temperature rise in thermocouples from 10 to 500 micrometers. At high radiation loads and low wind speeds, temperature errors were as large as 7 degrees C above air temperature.

NASA Program CELSS↗

Contrasting stream nitrate and sulfate response to recovery from experimental watershed acidification

Improvements in air quality have led to ecosystem recovery from acidic deposition, but the mechanisms and trajectories of this recovery are not fully understood. Here, we present long-term stream response and recovery data for paired watersheds at the Bear Brook Watershed in Maine (BBWM) during declining ambient SO 4 and NO 3 in precipitation. East Bear (EB) received ambient deposition from 1989 to 2018; West Bear (WB) received artificially elevated N+S from 1989 to 2016. The WB treatment was discontinued after 2016, the beginning of the recovery from both the experimental N+S and ambient decline. Stream SO 4 in WB gradually declined after the treatment ended, from ~147 µeq L -1 in 2010-16 to ~126 µeq L -1 in 2017-18. The declining S inputs induced desorption of SO 4 from soil phase surfaces, with stream loss far exceeding precipitation input. At the current rate of recovery, it will be many decades before the WB stream returns to pre-treatment SO 4 concentrations. In contrast, NO 3 is only weakly adsorbed in soil, and WB stream NO 3 concentrations rapidly declined from ~39 µeq L -1 in 2010-16 to ~5 µeq L -1 in 2017-18, comparable to the N-limited EB stream. The acid anions are strongly coupled to base cation chemistry in streams, and there was a distinct hysteretic response of Ca and Mg to the chronic acidification, as (Ca+Mg) increased rapidly during the initial years, followed by declining values due to depletion of the soil exchange complex. This 30-year monitoring study (1989-2019) provides insights into recovery mechanisms from acidic deposition and highlights the role of abiotic processes in soil that mediate nutrient cycling and retention. Finally, documenting the rapid response of N alongside the slower recovery for S identifies the temporal resolution necessary for other whole-watershed recovery studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overcharge investigation of large format lithium-ion pouch cells with Li(Ni 0.6 Co 0.2 Mn 0.2 )O 2 cathode for electric vehicles: Thermal runaway features and safety management method

The overcharge-induced thermal runaway features of large format commercial lithium-ion batteries with Li(Ni 0.6 Co 0.2 Mn 0.2 )O 2 (NCM622) cathode for electric vehicles under different current rates (C-rates) have been systematically studied at ambient temperature. The overcharge process is characterized as four stages. The temperature rise and the maximum temperature of the battery surface don't increase in proportion to the applied C-rates. However, with the increase of C-rates, the crest voltage of voltage curve rises linearly. When the voltage reaches approximately 5.1 V, a new voltage plateau appears in the cases below 2C. It is not sufficient that the temperature sensor is placed only near the terminal tab for most battery packs of EVs. In addition, the accumulated heat analysis demonstrates that side reactions dominate the temperature rise and contribute to most of the accumulated heat before thermal runaway. To mitigate the impact of overcharge and avoid the thermal runaway risk, a safety management method is proposed. Furthermore, the sharp drop in voltage before thermal runaway also provides a feasible approach to forewarn the users of the impending risk. These results are important for building safer batteries and providing information for the safety monitoring function of the battery management system (BMS).

25 ENERGY STORAGE↗

Electrical Charging Hazards Originating from the Surface (ECHOS): Understanding the Martian Electro-Meteorological Environment

In 1999, the NASA/Human Exploration and Development of Space (HEDS) enterprise selected a number of payloads to fly to the Martian surface in an 03 opportunity (prior to the MPL loss). Part of a proposed experiment, ECHOS, was selected to specifically understand the electrical charging hazards from tribocharged dust in the ambient atmosphere, in dust devils, and in larger storms. It is expected that Martian dust storms become tribocharged much like terrestrial dust devils which can possess almost a million elementary charges per cubic centimeter. The ECHOS package features a set of instruments for measuring electric effects: a radio to detect AC electric fields radiating from discharges in the storm,a DC electric field system for sensing electrostatic fields from concentrations of charged dust grains, and a lander electrometer chain for determining the induced potential on its body and MAV (Mars Ascent Vehicle) during the passages of a charged dust storm. Given that electricity is a systemic process originating from wind-blown dust, we also proposed to correlate the electrical measurements with fundamental fluid/meteorological observations, including wind velocity and vorticity, temperature, and pressure. Triboelectricity will also affect local chemistry, and chemical-sensing devices were also considered a feature of the package. The primary HEDS objectives of the ECHOS sensing suite is to discover and monitor the natural electrical hazards associated with dust devils and storms, and determine their enviro-effectiveness on human systems. However, ECHOS also has a strong footprint in the overarching science objectives of the Mars Surveyor Program.

Farrell, W. M.↗

Helmet-Mounted Display Research Capabilities of the NASA/Army Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL)

The Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) is a UH-60A Black Hawk helicopter that is being modified by the US Army and NASA for flight systems research. The principal systems that are being installed in the aircraft are a Helmet Mounted Display (HMD) and imaging system, and a programmable full authority Research Flight Control System (RFCS). In addition, comprehensive instrumentation of both the rigid body of the helicopter and the rotor system is provided. The paper will describe the capabilities of these systems and their current state of development. A brief description of initial research applications is included. The wide (40 X 60 degree) field-of-view HMD system has been provided by Kaiser Electronics. It can be configured as a monochromatic system for use in bright daylight conditions, a two color system for darker ambients, or a full color system for use in night viewing conditions. Color imagery is achieved using field sequential video and a mechanical color wheel. In addition to the color symbology, high resolution computer-gene rated imagery from an onboard Silicon Graphics Reality Engine Onyx processor is available for research in virtual reality applications. This synthetic imagery can also be merged with real world video from a variety of imaging systems that can be installed easily on the front of the helicopter. These sensors include infrared or tv cameras, or potentially small millimeter wave radars. The Research Flight Control System is being developed for the aircraft by a team of contractors led by Boeing Helicopters. It consists of a full authority high bandwidth fly-by-wire actuators that drive the main rotor swashplate actuators and the tail rotor actuator in parallel. This arrangement allows the basic mechanical flight control system of the Black Hawk to be retained so that the safety pilot can monitor the operation of the system through the action of his own controls. The evaluation pilot will signal the fly-by-wire actuators through the flight computer from electrical sidearm controllers located in the right hand cockpit. The system will have very substantial input/output capacity and impressive computational power. These systems are installed in the aircraft using predominantly a MIL-STD 1553B data bus architecture. Sensor data from the RFCS, the basic aircraft and rotor system instrumentation including navigation information, and the HMD system are easily exchanged among user systems, or are available at the systems operator station located in the cabin for real time monitoring or data recording.

Jacobsen, R. A.↗

Underwater Noise Measurements around a Tidal Turbine in a Busy Port Setting

Acoustic emissions from current energy converters remain an environmental concern for regulators because of their potential effects on marine life and uncertainties about their effects stemming from a lack of sufficient observational data. Several recent opportunities to characterize tidal turbine sound emissions have begun to fill knowledge gaps and provide a context for future device deployments. In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire’s Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory’s Triton Field Trials (TFiT) described in this Special Issue, this effort provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites.

tidal turbine↗

Fracture detection and imaging through relative seismic velocity changes using distributed acoustic sensing and ambient seismic noise

Fracture systems are important pathways for fluid and solute transport and exert a critical influence on the hydraulic properties of aquifers and reservoirs. Therefore, detailed knowledge of fracture locations, connections, and evolution is crucial for both groundwater and energy applications (e.g., enhanced geothermal, oil and gas recovery, carbon sequestration, and wastewater injection). The innovative combination of distributed acoustic sensing (DAS) and ambient seismic noise techniques has the potential to detect and characterize fracture systems at high-spatial and temporal resolution without an active source. To test this, we conducted a multiphysics field experiment at Blue Canyon Dome, New Mexico. A novel energetic material developed by Sandia National Laboratories was used to generate fractures in two separate stimulations. Ambient noise was recorded before and after each stimulation using fiber-optic cables installed in the outer annulus of four boreholes surrounding the stimulation hole at a radius of 1.2 m. The Python package MSNoise was used to compute crosscorrelations and measure changes in velocity between each time period relative to the initial (prestimulation) time period. The majority of channel pairs showed a velocity reduction (average –3% relative velocity change) following both stimulations. We used a 3D Bayesian tomography approach to resolve spatial variations by utilizing differences between channel pairs. Results showed that the greatest velocity reduction was concentrated near the center of the test area and suggested the presence of a near-vertical fracture, oriented northeast to southwest for depths >19 m below ground surface and extending slightly to the southwest corner. Finally, these results were generally consistent with crosshole seismic tomography time-lapse images. DAS technology provides valuable sensing capability and — when used with a passive seismic approach — shows great promise for monitoring and characterization of fractured-rock systems.

58 GEOSCIENCES↗