Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Distribution Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Smart detection of indoor occupant thermal state via infrared thermography, computer vision, and machine learning

The ability to measure occupants’ thermal state in real time will enable major advances in the control of air conditioning systems. This study proposes predicting occupant thermal state by a combination of infrared thermography, computer vision, and machine learning. The approach (1) uses cheek, nose, and hand temperatures because they are least subject to blockage by hair, glasses, and clothing; (2) measures the distribution of skin temperatures within geometrically defined sub-areas of the face and hand; and (3) uses temperature differences within and between these areas to eliminate the effects of calibration drift that are unavoidable in thermal infrared (TIR) cameras. Two series of tests were conducted, respectively in an outdoor carport and an indoor environmental chamber, collecting a total of 48,422 sets of cheek, nose, and hand skin temperatures using a TIR camera and computer-vision technology, coupled with 715 subjective responses of thermal sensations. To predict occupant thermal state, Random Forest classification models were built using either absolute skin temperatures (the maximum and median temperatures of cheek and hand segments, and the temperature of the central spot on the nose), or intra- and inter-segment temperature differences of cheeks, hands, and nose. These measurements were found to accurately predict occupant thermal state. Using the maximum and median temperatures for cheek and nose, or for cheek and hand, predicts thermal state with an accuracy of 92–96%. In conclusion, using only the intra- and inter-segment temperature differences from cheek and nose is 83% accurate; adding the hand temperature differences increases the accuracy to 96%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Boreal lakes moderate seasonal and diurnal temperature variation and perturb atmospheric circulation: Analyses in the Community Earth System Model 1 (CESM1)

We used a lake thermal physics model recently coupled into the Community Earth System Model 1 (CESM1) to study the effects of lake distribution in present and future climate. Under present climate, correcting the large underestimation of lake area in CESM1 (denoted CCSM4 in the configuration used here) caused 1 °C spring decreases and fall increases in surface air temperature throughout large areas of Canada and the US. Simulated summer surface diurnal air temperature range decreased by up to 4 °C, reducing CCSM4 biases. These changes were much larger than those resulting from prescribed lake disappearance in some present-day permafrost regions under doubled-CO 2 conditions. Correcting the underestimation of lake area in present climate caused widespread high-latitude summer cooling at 850 hPa. Significant remote changes included decreases in the strength of fall Southern Ocean westerlies. We found significantly different winter responses when separately analysing 45-yr subperiods, indicating that relatively long simulations are required to discern the impacts of surface changes on remote conditions. We also investigated the surface forcing of lakes using idealised aqua-planet experiments which showed that surface changes of 2 °C in the Northern Hemisphere extra-tropics could cause substantial changes in precipitation and winds in the tropics and Southern Hemisphere. Shifts in the Inter-Tropical Convergence Zone were opposite in sign to those predicted by some previous studies. Zonal mean circulation changes were consistent in character but much larger than those occurring in the lake distribution experiments, due to the larger magnitude and more uniform surface forcing in the idealised aqua-planet experiments.

54 ENVIRONMENTAL SCIENCES↗

Comparison of experimental and theoretical thermal fatigue lives for five nickel base alloys

The alloys Nimonic 90, IN 100, coated IN 100, B 1900, coated B 1900, MAR M200, and MAR M200DS (directionally solidified) were studied. Maximum temperatures ranged from 770 C to 1120 C (1420 F to 2050 F). Specimen geometries included tapered disks, double-edged wedges, and cambered airfoils. The disks and wedges were heated and cooled in fluidized beds. The airfoil specimens were heated by a Mach 1 natural gas burner and rapid-air-cooled, with and without spanwise loading. Life calculations included two distinct failure modes: conventional low cycle fatigue and cyclic creep. Required material properties were limited to conventional thermal, tensile, and creep rupture data. The complete life calculation system included the calculation of transient temperature distributions, thermal strains, stresses, creep damage, fatigue damage, and cycles to first crack. Calculated lives were within a factor of two for 76 of the 86 data points analyzed. Cyclic creep accounted for 81% of all the calculated damage.

Spera, D. A.↗

Calculation of the magnetic field in the active zone of a hysteresis clutch

The initial distribution of magnetic induction in the armature stationary was calculated relative to the polar system of a hysteresis clutch. Using several assumptions, the problem is reduced to calculating the static magnetic field in the ferromagnetic plate with finite and continuous magnetic permeability placed in the air gap between two identical, parallel semiconductors with rack fixed relative to the tooth or slot position.

Ermilov, M. A.↗

Experimental Setup and Parameters for Testing Uncoated and EBC-Coated CMCs under Thermal Gradients Induced by Laser Heating and Backside Air Cooling

An experimental setup to induce through thickness thermal gradients in ceramic matrix composite (CMC) specimens without and with an applied environmental barrier coating (EBC) is described in detail. Components of the experimental set up include a laser for the heat source on the front of the specimen, a cooling air nozzle on the back of the specimen with pyrometers to measure temperatures on both sides, and a full-field thermal image camera to ensure uniformity of the temperature distribution in the gage section of the specimen. Test specimen is loaded in a servohydraulic system, which can superimpose either static or dynamic loads on the specimen to investigate creep and fatigue behaviors of CMCs under through thickness thermal gradient conditions. Mechanical strains on the front and backsides of the test specimen were measured during the thermal gradient tests with superimposed mechanical loading using two contact extensometers. Selected through thickness thermal gradient test results generated with the experimental setup under different nominal front side temperatures and multiple constant laser power levels on uncoated and EBC coated CMCs and procedures used to generate those results are described in this report. Two examples of tests conducted using the test system on uncoated CMCs under creep and sustained-peak, low-cycle fatigue with through thickness thermal gradient conditions are provided.

ceramic matrix composite, environmental barrier co↗

Double-sided LCLC-compensated topology for capacitive power transfer

A double-sided LCLC-compensated network is proposed for a capacitive power transfer (CPT) system. In one design, four metal plates are used to form two power transmitting and receiving capacitors and the LCLC network is used to compensate the capacitors. In the second design, two extra metal plates are used to couple with the previous four plates at the transmitting and receiving side, respectively, which forms the capacitor-integrated structure. The circuit parameter values are tuned to achieve zero voltage switching (ZVS) of the input side switches. There is also a CLLC topology proposed, which is a similar variation of LCLC circuit. A 3.3 kW input power capacitive power transfer prototype is designed and built. The experiment results show that the proposed CPT system can transfer 3.1 kW output power through an air gap distance of 70 mm with a dc-to-dc efficiency of 92.1%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of the Potential Environmental Impacts from Large-Scale Use and Production of Hydrogen in Energy and Transportation Applications

The purpose of this project is to systematically identify and examine possible near and long-term ecological and environmental effects from the production of hydrogen from various energy sources based on the DOE hydrogen production strategy and the use of that hydrogen in transportation applications. This project uses state-of-the-art numerical modeling tools of the environment and energy system emissions in combination with relevant new and prior measurements and other analyses to assess the understanding of the potential ecological and environmental impacts from hydrogen market penetration. H 2 technology options and market penetration scenarios will be evaluated using energy-technology-economics models as well as atmospheric trace gas projections based on the IPCC SRES scenarios including the decline in halocarbons due to the Montreal Protocol. Specifically we investigate the impact of hydrogen releases on the oxidative capacity of the atmosphere, the long-term stability of the ozone layer due to changes in hydrogen emissions, the impact of hydrogen emissions and resulting concentrations on climate, the impact on microbial ecosystems involved in hydrogen uptake, and criteria pollutants emitted from distributed and centralized hydrogen production pathways and their impacts on human health, air quality, ecosystems, and structures under different penetration scenarios

08 HYDROGEN↗

Representative elementary volume estimation for porosity, moisture saturation, and air-water interfacial areas in unsaturated porous media: Data quality implications

Achieving a representative elementary volume (REV) has become a de facto criterion for demonstrating the quality of {mu}CT measurements in porous media systems. However, the data quality implications of an REV requirement have not been previously examined. In this work, deterministic REVs for porosity, moisture saturation (S{sub W}), and air-water interfacial area (A{sub I}) were estimated using a set of 49 {mu}CT images of eight unsaturated homogeneous porous media with heterogeneity in moisture distributions present in varying degrees. Estimated porosity REVs were <8 mm{sup 3} for all cases, smaller than typical CT image sizes ({approx}100 mm{sup 3}). Estimated S{sub W} and A{sub I} REVs were <55 mm{sup 3} for cases with homogeneous moisture distributions but could not be estimated for cases with heterogeneous moisture distributions, due to the absence of a distinct 'REV plateau' within the maximum imaged volume. Conventionally, S{sub W} and A{sub I} data from such non-REV cases would be excluded. The implications of excluding data on the basis of REV were examined by comparing A{sub I}-S{sub W} data measured on image windows of increasing size against the expected linear A{sub I}-S{sub W} relationship. At measurement scales exceeding porosity REV, random fluctuations in A{sub I}-S{sub W} data were excluded, even for cases containing heterogeneous moisture distributions. In contrast, requiring measurement scales to exceed S{sub W} and A{sub I} REV appeared overly restrictive and resulted in visible loss of reliable A{sub I}-S{sub W} data. We attribute these findings to overestimation of REVs due to inherently problematic estimation of deterministic REVs in real systems. Implications of these findings for ensuring CT data quality and the efficient use of CT data are discussed.

99 GENERAL AND MISCELLANEOUS↗

Ozone and aerosol changes during the 1991-1992 airborne Arctic stratospheric expedition

Stratospheric ozone and aerosol distributions were measured across the wintertime Arctic vortex from January to March 1992 with an airborne lidar system as part of the 1992 Airborne Arctic Stratospheric Expedition (AASE II). Aerosols from the Mount Pinatubo eruption were found outside and inside the vortex with distinctly different distributions that clearly identified the dynamics of the vortex. Changes in aerosols inside the vortex indicated advection of air from outside to inside the vortex below 16 kilometers. No polar stratospheric clouds were observed and no evidence was found for frozen volcanic aerosols inside the vortex. Between January and March, ozone depletion was observed inside the vortex from 14 to 20 kilometers with a maximum average loss of about 23 percent near 18 kilometers.

Browell, Edward V.↗

Preliminary analysis of pilot ratings of 'part line' information importance

With the introduction of digital datalink communications into the Air Traffic Control (ATC) system, there is concern over the potential loss of situational awareness by flight crews due to the reduction in the 'Party Line Information' (PLI). This information is available to the pilot by overhearing communications between ATC and other aircraft. A survey was distributed to determine current PLI use by several pilot operational groups, experience levels and geographic regions. The survey identified numerous important elements. PLI was rated the highest for operations near or on approach to the airport. Several significant variations were found between pilots from different operational groups and experience levels. Traffic and weather information were the most frequently cited as information required to obtain global situation awareness.

Pritchett, Amy↗

Preliminary analysis of graphite dust releasing behavior in accident for HTR

The behavior of the graphite dust is important to the safety of High Temperature Gas-cooled Reactors. This study investigated the flow of graphite dust in helium mainstream. The analysis of the stresses acting on the graphite dust indicated that gas drag played the absolute leading role. Based on the understanding of the importance of gas drag, an experimental system is set up for the research of dust releasing behavior in accident. Air driven by centrifugal fan is used as the working fluid instead of helium because helium is expensive, easy to leak which make it difficult to seal. The graphite particles, with the size distribution same as in HTR, are added to the experiment loop. The graphite dust releasing behavior at the loss-of-coolant accident will be investigated by a sonic nozzle. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Health and Climate Benefits of Economic Dispatch in China’s Power System

China’s power system is highly regulated and uses an “equal-share” dispatch approach. However, market mechanisms are being introduced to reduce generation costs and improve system reliability. Here, we quantify the climate and human health impacts brought about by this transition, modeling China’s power system operations under economic dispatch. We find that significant reductions in mortality related to air pollution (11%) and CO 2 emissions (3%) from the power sector can be attained by economic dispatch, relative to the equal-share approach, through more efficient coal-powered generation. Additional health and climate benefits can be achieved by incorporating emission externalities in electricity generation costs. However, the benefits of the transition to economic dispatch will be unevenly distributed across China and may lead to increased health damage in some regions. Our results show the potential of dispatch decision-making in electricity generation to mitigate the negative impacts of power plant emissions with existing facilities in China.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-F-SPS-02: Accuracy of the Small Field Dosimetry Using the Monte Carlo and Sequential Dose Calculation Algorithms of Multiplan Treatment Planning System Within and Beyond Heterogeneous Media for Cyberknife M6 Unit

Purpose: In small field geometries, the electronic equilibrium can be lost, making it challenging for the dose-calculation algorithm to accurately predict the dose, especially in the presence of tissue heterogeneities. In this study, dosimetric accuracy of Monte Carlo (MC) advanced dose calculation and sequential algorithms of Multiplan treatment planning system were investigated for small radiation fields incident on homogeneous and heterogeneous geometries. Methods: Small open fields of fixed cones of Cyberknife M6 unit 100 to 500 mm2 were used for this study. The fields were incident on in house phantom containing lung, air, and bone inhomogeneities and also homogeneous phantom. Using the same film batch, the net OD to dose calibration curve was obtained using CK with the 60 mm fixed cone by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. The dosimetric accuracy of MC and sequential algorithms in the presence of the inhomogeneities was compared against EBT3 film dosimetry Results: Open field tests in a homogeneous phantom showed good agreement between two algorithms and film measurement For MC algorithm, the minimum gamma analysis passing rates between measured and calculated dose distributions were 99.7% and 98.3% for homogeneous and inhomogeneous fields in the case of lung and bone respectively. For sequential algorithm, the minimum gamma analysis passing rates were 98.9% and 92.5% for for homogeneous and inhomogeneous fields respectively for used all cone sizes. In the case of the air heterogeneity, the differences were larger for both calculation algorithms. Overall, when compared to measurement, the MC had better agreement than sequential algorithm. Conclusion: The Monte Carlo calculation algorithm in the Multiplan treatment planning system is an improvement over the existing sequential algorithm. Dose discrepancies were observed for in the presence of air inhomogeneities.

60 APPLIED LIFE SCIENCES↗

Techno-Economic Analysis of a Microgrid System for Rural Communities in the United States

Access to running water has been a pressing issue in many developing countries across the globe, and also continues to be a problem in some rural areas in the United States. Today, more than two million Americans living in rural areas lack access to basic water supply and infrastructure. Rural communities tend to be located in environmentally fragile areas with poor economic conditions, making access to appropriate, low-cost technology for clean water supply and sanitation more challenging. In addition, many of the water resources located in these areas are being jeopardized by climate change in recent years. This research proposes a photovoltaic (PV)-battery microgrid system for powering water pumps in off-grid areas in an effort to identify economically and technologically feasible solution to the problems. Utilizing the HOMER Pro software, developed by the U.S. National Renewable Energy Laboratory (NREL), the case of the Navajo Nation is examined by analyzing the effects of this region's air temperature on the life and performance of battery storage and the economics of the proposed microgrid system.

battery↗

Quiet Cruise Efficient Short Take-off and Landing Subsonic Transport System

This NASA funded study conceived a revolutionary airplane concept to enable future traffic growth by using regional air space. This requires a very quiet airplane with STOL capability. Starting with a Blended Wing Body that is cruise efficient with inherent low noise characteristics from forward noise shielding and void of aft downward noise reflections, integration of embedded distributed propulsion enables incorporation of the revolutionary concept for jet noise shielding. Embedded distributed propulsion also enables incorporation of a fan bleed internally blown flap for quiet powered lift. The powered lift provides STOL capability for operation at regional airports with rapid take-off and descent to further reduce flyover noise. This study focused on configuring the total engine noise shielding STOL concept with a BWB airplane using the Boeing Phantom Works WingMOD multidisciplinary optimization code to define a planform that is pitch controllable. The configuration was then sized and mission data developed to enable NASA to assess the flyover and sideline noise. The foundational technologies needed are identified including military dual use benefits.

Kawai, Ron↗

Effects of cooling system parameters on heat transfer in PAFC stack

Analytical and experimental study for the effects of cooling system parameters on the heat transfer and temperature distribution in the electrode plates of a phosphoric acid fuel-cell has been conducted. An experimental set-up that simulates the operating conditions prevailing in a phosphoric-acid fuel-cell stack was designed and constructed. The set-up was then used to measure the overall heat transfer coefficient, the thermal contact resistance, and the electrode temperature distribution for two different cooling plate configurations. Two types of cooling plate configurations, serpentine and straight, were tested. Air, water, and oil were used as coolants. Measurements for the heat transfer coefficient and the thermal contact resistance were made for various flow rates ranging from 16 to 88 Kg/hr, and stack clamping pressure ranging from O to 3448 Kpa. The experimental results for the overall heat transfer coefficient were utilized to derive mathematical relations for the overall heat transfer coefficient as a function of stack clamping pressure and Reynolds number for the three coolants. The empirically derived formulas were incorporated in a previously developed computer program to predict electrodes temperature distribution and the performance of the stack cooling system. The results obtained were then compared with those available in the literature. The comparison showed maximum deviation of +/- 11%.

Abdul-Aziz, Ali A.↗

Slow Dynamics Model of Compressed Air Energy Storage and Battery Storage Technologies for Automatic Generation Control

Increasing variable generation penetration and the consequent increase in short-term variability makes energy storage technologies look attractive, especially in the ancillary market for providing frequency regulation services. This paper presents slow dynamics model for compressed air energy storage and battery storage technologies that can be used in automatic generation control studies to assess the system frequency response and quantify the benefits from storage technologies in providing regulation service. The paper also represents the slow dynamics model of the power system integrated with storage technologies in a complete state space form. The storage technologies have been integrated to the IEEE 24 bus system with single area, and a comparative study of various solution strategies including transmission enhancement and combustion turbine have been performed in terms of generation cycling and frequency response performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Traffic Flow Management Decision Making

A generalized approach is proposed to support integrated traffic flow management decision making studies at both the U.S. national and regional levels. It can consider tradeoffs between alternative optimization and heuristic based models, strategic versus tactical flight controls, and system versus fleet preferences. Preliminary testing was accomplished by implementing thirteen unique traffic flow management models, which included all of the key components of the system and conducting 85, six-hour fast-time simulation experiments. These experiments considered variations in the strategic planning look-ahead times, the replanning intervals, and the types of traffic flow management control strategies. Initial testing indicates that longer strategic planning look-ahead times and re-planning intervals result in steadily decreasing levels of sector congestion for a fixed delay level. This applies when accurate estimates of the air traffic demand, airport capacities and airspace capacities are available. In general, the distribution of the delays amongst the users was found to be most equitable when scheduling flights using a heuristic scheduling algorithm, such as ration-by-distance. On the other hand, equity was the worst when using scheduling algorithms that took into account the number of seats aboard each flight. Though the scheduling algorithms were effective at alleviating sector congestion, the tactical rerouting algorithm was the primary control for avoiding en route weather hazards. Finally, the modeled levels of sector congestion, the number of weather incursions, and the total system delays, were found to be in fair agreement with the values that were operationally observed on both good and bad weather days.

Grabbe, Shon R.↗