Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ASSESSMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

The Apache Longbow-Hellfire Missile Test at Yuma Proving Ground: Ecological Risk Assessment for Helicopter Overflight

A multi-stressor risk assessment was conducted at Yuma Proving Ground, Arizona, as a demonstration of the Military Ecological Risk Assessment Framework. The focus of the assessment was a testing program at Cibola Range, which involved an Apache Longbow helicopter firing Hellfire missiles at moving targets, M60-A1 tanks. This paper focuses on the wildlife risk assessment for the helicopter overflight. The primary stressors were sound and the view of the aircraft. Exposure to desert mule deer (Odocoileus hemionus crooki) was quantified using Air Force sound contour programs NOISEMAP and MR_NMAP, which gave very different results. Slant distance from helicopters to deer was also used as a measure of exposure that integrated risk from sound and view of the aircraft. Exposure-response models for the characterization of effects consisted of behavioral thresholds in sound exposure level or maximum sound level units or slant distance. Available sound thresholds were limited for desert mule deer, but a distribution of slant-distance thresholds was available for ungulates. The risk characterization used a weight-of-evidence approach and concluded that risk to mule deer behavior from the Apache overflight is uncertain, but that no risk to mule deer abundance and reproduction is expected.

43 PARTICLE ACCELERATORS↗

Assessment of doses in contaminated urban areas: modelling exercise based on Fukushima data

State-of-the-art dose assessment models were applied to estimate doses to the population in urban areas contaminated by the Fukushima Daiichi Nuclear Power Plant accident. Assessment results were compared among five models, and comparisons of model predictions with actual measurements were also made. Assessments were performed using both probabilistic and deterministic approaches. Predicted dose distributions for indoor and outdoor workers from a probabilistic approach were in good agreement with the actual measurements. In addition, when the models were applied to assess the doses to the representative person, based on a concept recommended by the International Commission on Radiological Protection and in the International Atomic Energy Agency Safety Standards, it was evident that doses to the representative person obtained with a deterministic approach were always higher than those obtained with a probabilistic approach using the same model.

dose assessment↗

Quantum-Inspired Power System Reliability Assessment

To enable an in-depth study of power system operation and planning, the assessment of standard reliability indices is inevitable. The Monte Carlo Simulation (MCS) approach is a broadly used method in replacing the analytical methods in reliability indices assessment. The accuracy of MCS, however, highly depends on the sampling size, and hence, a complicated system with large number of components requires a large sampling size and daunting computational effort. To address this shortcoming, we, in this paper attempt to take advantage of potentials of the quantum computing (QC) for power system reliability assessment by realizing the following contributions: 1) an innovative quantum model designed for reliability assessment; 2) a quantum circuit that achieves the quadratic speed up compared to the classical MCS method; 3) an efficient quantum amplitude estimation (QAE) algorithm to accurately evaluate the reliability indices. The accuracy and efficacy of the quantum reliability method are extensively verified and demonstrated on both radial and mesh distribution systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Risk Assessment of Rare Events in Power Systems With Uncertain Wind Generation and Loads

Risk assessment of rare events has become increasingly important in power system planning and operation with the increasing integration of renewable energy and the presence of system uncertainties. However, quantifying the risk posed by rare events via the traditional method, i.e., Monte Carlo sampling (MCS), incurs substantial computational expense stemming from the vast ensemble of power flow simulations. To accelerate the assessment, this paper proposes a Deep Neural Network (DNN)-kernelized vector-valued Gaussian Process (VVGP) approach with excellent computational efficiency while maintaining high accuracy. Consequently, serving as a surrogate model for the power flow solver, the DNN-kernelized VVGP enables significantly faster but accurate risk assessment compared to the power flow solver. The developed surrogate model evaluates low-order N - k events that contain more than 90% instances by adeptly capturing the topological features while the high-order N - k events are assessed via a power flow solver, thereby striking a balance between computational efficiency and uncertainty quantification accuracy. Moreover, the model incorporates a Support Vector Machine (SVM) classifier to resample concerning low-probability tail events to counteract the biases potentially introduced during the DNN-kernelized VVGP evaluations. Simulations conducted on the modified IEEE 24-bus, 118-bus, and European 1354-bus systems demonstrate that the proposed method maintains the accuracy benchmark set by MCS while significantly reducing computational demands in large-scale power systems as compared to other state-of-the-art methods.

17 WIND ENERGY↗

Criterion validity of wrist accelerometry for assessing energy intake via the intake-balance technique

Background: Intake-balance assessments measure energy intake (EI) by summing energy expenditure (EE) with concurrent change in energy storage (ΔES). Prior work has not examined the validity of such calculations when EE is estimated via open-source techniques for research-grade accelerometry devices. The purpose of this study was to test the criterion validity of accelerometry-based intake-balance methods for a wrist-worn ActiGraph device. Methods: Healthy adults (n = 24) completed two 14-day measurement periods while wearing an ActiGraph accelerometer on the non-dominant wrist. During each period, criterion values of EI were determined based on ΔES measured by dual X-ray absorptiometry and EE measured by doubly labeled water. A total of 11 prediction methods were tested, 8 derived from the accelerometer and 3 from non-accelerometry methods (e.g., diet recall; included for comparison). Group-level validity was assessed through mean bias, while individual-level validity was assessed through mean absolute error, mean absolute percentage error, and Bland–Altman analysis. Results: Mean bias for the three best accelerometry-based methods ranged from -167 to 124 kcal/day, versus -104 to 134 kcal/day for the non-accelerometry-based methods. The same three accelerometry-based methods had mean absolute error of 323–362 kcal/day and mean absolute percentage error of 18.1-19.3%, versus 353–464 kcal/day and 19.5-24.4% for the non-accelerometry-based methods. All 11 methods demonstrated systematic bias in the Bland–Altman analysis. Conclusions: Accelerometry-based intake-balance methods have promise for advancing EI assessment, but ongoing refinement is necessary. We provide an R package to facilitate implementation and refinement of accelerometry-based methods in future research (see paulhibbing.com/IntakeBalance).

60 APPLIED LIFE SCIENCES↗

Impact of Thermal Scattering Law on Similarity Assessment in Light-Water or Polyethylene-Moderated Systems

A collaborative effort between Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) is underway to provide a technical basis and methodology for the criticality safety community to use the sum of fractions (SoF) method for generating limits for mixtures of “selected actinide nuclides” included in the ANSI/ANS 8.15 standard. The PNNL scope in this project is to define a range of mixtures of 233 U, 235 U, and 239 Pu moderated with either light water or polyethylene and to examine the critical masses for these mixtures. The ORNL scope is primarily to provide validation support for these studies. More complete discussion of the project and its validation aspects will be presented at the upcoming International Conference on Nuclear Criticality Safety (ICNC) this Fall in Sendai, Japan. Clear differences in benchmark similarity to application systems as assessed by the integral parameter ck are noted in the validation studies performed as part of this project as a function of moderator. The c k value is a correlation coefficient that represents that amount of shared uncertainty in k eff due to cross sections between two systems. Individual nuclide-reaction contributions between the two systems can be simply summed to arrive at the total c k value. Specifically, the c k values for light-water–moderated solution experiments are higher for a water-moderated application than for a polyethylene-moderated application. This result is neither totally unexpected nor surprising, but the magnitude of the difference was difficult to anticipate. The TSUNAMI sequence, in the SCALE 6.2.4 code package developed by ORNL, was used to generate eigenvalues and reactivity effects with perturbation-theory based approach through sensitivity coefficients for all nuclides in the system with all reactions and energy groups. The TSUNAMI-Indices and Parameters (IP) sequence then uses the sensitivity data generated through TSUNAMI to generate relational parameters (i.e., c k ) to determine the degree of similarity between systems. One detail of the SCALE material and data implementation must be discussed at this point. Several thermal scattering laws (TSLs) are available for 1 H. SCALE uses a different nuclide ID number for each TSL; essentially, each version of 1 H is treated as a unique nuclide. For example, 1 H bound in water ( 1 H-H2O) is assigned the nuclide ID 1001, whereas 1 H bound in polyethylene (h-poly) is assigned the nuclide ID 9001001. The same cross section data are used for all reactions in 1 H, regardless of TSL, except for scattering below the TSL cutoff energy. TSUNAMI-IP treats different nuclide IDs as different nuclides; thus, no uncertainty is shared between 1 H-H2O and h-poly, despite much of the same data, including covariance data, being used for both nuclides. This presents a question: how much of the difference in assessed similarity between water- and polyethylene-moderated systems is due to the moderators, and how much is caused by the treatment of 1 H-H2O and h poly with cross section and covariance data. The extended edits generated by TSUANMI-IP allow for an investigation of this issue specifically, as well as a demonstration of the general techniques available within TSUNAMI to understand the results of the similarity assessment. This paper presents and analyzes the similarity assessment of both water- and polyethylene-moderated systems for a single benchmark: PST-002-001.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Geothermal Water Use: Life Cycle Water Consumption, Water Resource Assessment, and Water Policy Framework

This report examines life cycle water consumption for various geothermal technologies to better understand factors that affect water consumption across the life cycle (e.g., power plant cooling, belowground fluid losses) and to assess the potential water challenges that future geothermal power generation projects may face. Previous reports in this series quantified the life cycle freshwater requirements of geothermal power-generating systems, explored operational and environmental concerns related to the geochemical composition of geothermal fluids, and assessed future water demand by geothermal power plants according to growth projections for the industry. This report seeks to extend those analyses by including EGS flash, both as part of the life cycle analysis and water resource assessment. A regional water resource assessment based upon the life cycle results is also presented. Finally, the legal framework of water with respect to geothermal resources in the states with active geothermal development is also analyzed.

15 GEOTHERMAL ENERGY↗

The State of In Vitro Science for Use in Bioaccumulation Assessments for Fish

Through the concerted evaluations of thousands of commercial substances for the qualities of persistence, bioaccumulation, and toxicity as a result of the United Nations Environment Program’s Stockholm Convention, it has become apparent that fewer empirical data are available on bioaccumulation than other endpoints and that bioaccumulation models were not designed to accommodate all chemical classes. Due to the number of chemicals that may require further assessment, in vivo testing is cost prohibitive and discouraged due to the large number of animals needed. Although in vitro systems are less developed and characterized for fish, multiple high-throughput in vitro assays have been used to explore the dietary uptake and elimination of pharmaceuticals and other xenobiotics by mammals. While similar processes determine bioaccumulation in mammalian species, a review of methods to measure chemical bioavailability in fish screening systems, such as chemical biotransformation or metabolism in tissue slices, perfused tissues, fish embryos, primary and immortalized cell lines, and subcellular fractions, suggest quantitative and qualitative differences between fish and mammals exist. Using in vitro data in assessments for whole organisms or populations requires certain considerations and assumptions to scale data from a test tube to a fish, and across fish species. Also, different models may incorporate the predominant site of metabolism, such as the liver, and significant presystemic metabolism by the gill or gastrointestinal system to help accurately convert in vitro data into representative whole-animal metabolism and subsequent bioaccumulation potential. The development of animal alternative tests for fish bioaccumulation assessment is framed in the context of in vitro data requirements for regulatory assessments in Europe and Canada.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Bottom-up Representation of Industrial Energy Efficiency Technologies in Integrated Assessment Models for the Iron and Steel Sector

Adoption of efficient end-use technologies is one of the key measures for reducing greenhouse gas (GHG) emissions. With the working of energy programs and policies on carbon regulation, how to effectively analyze and manage the costs associated with GHG reductions become extremely important for the industry and policy makers around the world. Energy-climate (EC) models are often used for analyzing the costs of reducing GHG emissions (e.g., carbon emission) for various emission-reduction measures, because an accurate estimation of these costs is critical for identifying and choosing optimal emission reduction measures, and for developing related policy options to accelerate market adoption and technology implementation. However, accuracies of assessing of GHG-emission reduction costs by taking into account the adoption of energy efficiency technologies will depend on how well these end-use technologies are represented in integrated assessment models (IAM) and other energy-climate models. In this report, we first conduct brief overview on different representations of end-use technologies (mitigation measures) in various energy-climate models, followed by problem statements, and a description of the basic concepts of quantifying the cost of conserved energy including integrating non-regrets options. A non-regrets option is defined as a GHG reduction option that is cost effective, without considering their additional benefits related to reducing GHG emissions. Based upon these, we develop information on costs of mitigation measures and technological change. These serve as the basis for collating the data on energy savings and costs for their future use in integrated assessment models. In addition to descriptions of the iron and steel making processes, and the mitigation measures identified in this study, the report includes tabulated databases on costs of measure implementation, energy savings, carbon-emission reduction, and lifetimes. The cost curve data on mitigation measures are available over time, which allows an estimation of technological change over a decade-long historical period. In particular, the report will describe new treatment of technological change in energy-climate modeling for this industry sector, i.e., assessing the changes in costs and energy-savings potentials via comparing 1994 and 2002 conservation supply curves. In this study, we compared the same set of mitigation measures for both 1994 and 2002 -- no additional mitigation measure for year 2002 was included due to unavailability of such data. Therefore, the estimated potentials in total energy savings and carbon reduction would most likely be more conservative for year 2002 in this study. Based upon the cost curves, the rate of change in the savings potential at a given cost can be evaluated and be used to estimate future rates of change that can be the input for energy-climate models. Through characterizing energy-efficiency technology costs and improvement potentials, we have developed and presented energy cost curves for energy efficiency measures applicable to the U.S. iron and steel industry for the years 1994 and 2002. The cost curves can change significantly under various scenarios: the baseline year, discount rate, energy intensity, production, industry structure (e.g., integrated versus secondary steel making and number of plants), efficiency (or mitigation) measures, share of iron and steel production to which the individual measures can be applied, and inclusion of other non-energy benefits. Inclusion of other non-energy benefits from implementing mitigation measures can reduce the costs of conserved energy significantly. In addition, costs of conserved energy (CCE) for individual mitigation measures increase with the increases in discount rates, resulting in a general increase in total cost of mitigation measures for implementation and operation with a higher discount rate. In 1994, integrated steel mills in the U.S. produced 55.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Review of Natural Phenomena Hazard (NPH) Assessments for the DOE Hanford Site

The purpose of this review is to assess the need for updating Natural Phenomena Hazard (NPH) assessments for the DOE's Hanford Site, as required by DOE Order 420.1B Chapter IV, Natural Phenomena Hazards Mitigation, based on significant changes in state-of-the-art NPH assessment methodology or site-specific information. This review is an update and expansion to the September 2010 review of PNNL-19751, Review of Natural Phenomena Hazard (NPH) Assessments for the Hanford 200 Areas (Non-Seismic).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

2010 Manufacturing Readiness Assessment Update to the 2008 Report for Fuel Cell Stacks and Systems for the Backup Power and Materials Handling Equipment Markets

In 2008, the National Renewable Energy Laboratory (NREL), under contract to the US Department of Energy (DOE), conducted a manufacturing readiness assessment (MRA) of fuel cell systems and fuel cell stacks for back-up power and material handling applications (MHE). To facilitate the MRA, manufacturing readiness levels (MRL) were defined that were based on the Technology Readiness Levels previously established by the US Department of Energy (DOE). NREL assessed the extensive existing hierarchy of MRLs developed by Department of Defense (DoD) and other Federal entities, and developed a MRL scale adapted to the needs of the Fuel Cell Technologies Program (FCTP) and to the status of the fuel cell industry. The MRL ranking of a fuel cell manufacturing facility increases as the manufacturing capability transitions from laboratory prototype development through Low Rate Initial Production to Full Rate Production. DOE can use MRLs to address the economic and institutional risks associated with a ramp-up in polymer electrolyte membrane (PEM) fuel cell production. In 2010, NREL updated this assessment, including additional manufacturers, an assessment of market developments since the original report, and a comparison of MRLs between 2008 and 2010.

08 HYDROGEN↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transformer Efficiency Assessment - Okinawa, Japan

The US Army Engineering & Support Center, Huntsville (USAESCH), and the US Marine Corps Base (MCB), Okinawa, Japan retained Idaho National Laboratory (INL) to conduct a Transformer Efficiency Assessment of “key” transformers located at multiple military bases in Okinawa, Japan. The purpose of this assessment is to support the Marine Corps Base, Okinawa in evaluating medium voltage distribution transformers for potential efficiency upgrades. The original scope of work included the MCB providing actual transformer nameplate data, manufacturer’s factory test sheets, electrical system data (kWh), demand data (kWd), power factor data, and electricity cost data. Unfortunately, the MCB’s actual data is not available and therefore making it necessary to de-scope the original assessment. Note: Any similar nameplate data, photos of similar transformer nameplates, and basic electrical details from one-line drawings (provided by MCB) are not a replacement for actual load loss test data. It is recommended that load measurements are performed on the high and low sides of transformers to better quantify actual load losses, demand data, and power factor data. We also recommend that actual data, when available, be inserted by MCB Okinawa where assumptions have been made and then the LCC analysis updated. This report covers a generalized assessment of modern U.S. transformers in a three level efficiency category, Low-Level efficiency, Medium-Level efficiency, and High-Level efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RELAP5-3D Developmental Assessment: Comparison of Versions 4.0.3is and 2.4.2is

Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.0.3is and 2.4.2is. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Developmental Assessment: Comparison of Versions 4.1.3is and 4.0.3is

Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.1.3is and 4.0.3is. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Developmental Assessment: Comparison of Versions 4.2.1i and 4.1.3i

Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.2.1i and 4.1.3i. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RELAP5-3D Developmental Assessment: Comparison of Versions 4.3.4i and 4.2.1i

Figures have been generated comparing the parameters used in the developmental assessment of the RELAP5-3D code using versions 4.3.4i and 4.2.1i. The figures, which are the same as those used in Volume III of the RELAP5-3D code manual, compare calculations using the semi-implicit solution scheme with available experiment data. These figures provide a quick, visual indication of how the code predictions changed between these two code versions and can be used to identify cases in which the assessment judgment may need to be changed in Volume III of the code manual. Changes to the assessment judgments made after reviewing all of the assessment cases are also provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗