Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Analysis and experimental study on formation conditions of large-scale barrier-free diffuse atmospheric pressure air plasmas in repetitive pulse mode

Atmospheric air diffuse plasmas have enormous application potential in various fields of science and technology. Without dielectric barrier, generating large-scale air diffuse plasmas is always a challenging issue. This paper discusses and analyses the formation mechanism of cold homogenous plasma. It is proposed that generating stable diffuse atmospheric plasmas in open air should meet the three conditions: high transient power with low average power, excitation in low average E-field with locally high E-field region, and multiple overlapping electron avalanches. Accordingly, an experimental configuration of generating large-scale barrier-free diffuse air plasmas is designed. Based on runaway electron theory, a low duty-ratio, high voltage repetitive nanosecond pulse generator is chosen as a discharge excitation source. Using the wire-electrodes with small curvature radius, the gaps with highly non-uniform E-field are structured. Experimental results show that the volume-scaleable, barrier-free, homogeneous air non-thermal plasmas have been obtained between the gap spacing with the copper-wire electrodes. The area of air cold plasmas has been up to hundreds of square centimeters. The proposed formation conditions of large-scale barrier-free diffuse air plasmas are proved to be reasonable and feasible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robustness analysis of an air heating plant and control law by using polynomial chaos

This paper presents a robustness analysis of an air heating plant with a multivariable closed-loop control law by using the polynomial chaos methodology (MPC). The plant consists of a PVC tube with a fan in the air input (that forces the air through the tube) and a mass flux sensor in the output. A heating resistance warms the air as it flows inside the tube, and a thermo-couple sensor measures the air temperature. The plant has thus two inputs (the fan's rotation intensity and heat generated by the resistance, both measured in percent of the maximum value) and two outputs (air temperature and air mass flux, also in percent of the maximal value). The mathematical model is obtained by System Identification techniques. The mass flux sensor, which is nonlinear, is linearized and the delays in the transfer functions are properly approximated by non-minimum phase transfer functions. The resulting model is transformed to a state-space model, which is used for control design purposes. The multivariable robust control design techniques used is the LQG/LTR, and the controllers are validated in simulation software and in the real plant. Finally, the MPC is applied by considering some of the system's parameters as random variables (one at a time, and the system's stochastic differential equations are solved by expanding the solution (a stochastic process) in an orthogonal basis of polynomial functions of the basic random variables. This method transforms the stochastic equations in a set of deterministic differential equations, which can be solved by traditional numerical methods (That is the MPC). Statistical data for the system (like expected values and variances) are then calculated. The effects of randomness in the parameters are evaluated in the open-loop and closed-loop pole's positions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A comparison between spectra of runaway electron beams in SF{sub 6} and air

Runaway electron (RAE) with extremely high-energy plays important role on the avalanche propagation, streamer formation, and ionization waves in nanosecond-pulse discharges. In this paper, the generation of a supershort avalanche electron beam (SAEB) in SF{sub 6} and air in an inhomogeneous electric field is investigated. A VPG-30-200 generator with a pulse rise time of ∼1.6 ns and a full width at half maximum of 3–5 ns is used to produce RAE beams. The SAEBs in SF{sub 6} and air are measured by using aluminum foils with different thicknesses. Furthermore, the SAEB spectra in SF{sub 6} and air at pressures of 7.5 Torr, 75 Torr, and 750 Torr are compared. The results showed that amplitude of RAE beam current generated at the breakdown in SF{sub 6} was approximately an order of magnitude less than that in air. The energy of SAEB in air was not smaller than that in SF{sub 6} in nanosecond-pulse discharges under otherwise equal conditions. Moreover, the difference between the maximum energy of the electron distributions in air and SF{sub 6} decreased when the rise time of the voltage pulse increased. It was because the difference between the breakdown voltages in air and SF{sub 6} decreased when the rise time of the voltage pulse increased.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical study of turbulence-influence mechanism on arc characteristics in an air direct current circuit breaker

This paper focuses on the numerical investigation of arc characteristics in an air direct current circuit breaker (air DCCB). Using magneto-hydrodynamics (MHD) theory, 3D laminar model and turbulence model are constructed and calculated. The standard k-epsilon model is utilized to consider the turbulence effect in the arc chamber of the DCCB. Several important phenomena are found: the arc column in the turbulence-model case is more extensive, moves much more slowly than the counterpart in the laminar-model case, and shows stagnation at the entrance of the chamber, unlike in the laminar-model case. Moreover, the arc voltage in the turbulence-model case is much lower than in the laminar-model case. However, the results in the turbulence-model case show a much better agreement with the results of the breaking experiments under DC condition than in the laminar-model case, which is contradictory to the previous conclusions from the arc researches of both the low-voltage circuit breaker and the sulfur hexafluoride (SF6) nozzle. First, in the previous air-arc research of the low-voltage circuit breaker, it is assumed that the air plasma inside the chamber is in the state of laminar, and the laminar-model application gives quite satisfactory results compared with the experiments, while in this paper, the laminar-model application works badly. Second, the turbulence-model application in the arc research of the SF6-nozzle performs much better and gives higher arc voltage than the laminar-model application does, whereas in this paper, the turbulence-model application predicts lower arc voltage than the laminar-model application does. Based on the analysis of simulation results in detail, the mechanism of the above phenomena is revealed. The transport coefficients are strongly changed by turbulence, which will enhance the arc diffusion and make the arc volume much larger. Consequently, the arc appearance and the distribution of Lorentz force in the turbulence-model case substantially differ from the arc appearance and the distribution of Lorentz force in the laminar-model case. Thus, the moving process of the arc in the turbulence-model case is slowed down and slower than in the laminar-model case. Moreover, the more extensive arc column in the turbulence-model case reduces the total arc resistance, which results in a lower arc voltage, more consistent with the experimental results than the arc voltage in the laminar-model case. Therefore, the air plasma inside this air DCCB is believed to be in the turbulence state, and the turbulence model is more suitable than the laminar model for the arc simulation of this kind of air DCCB.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the proton-air inelastic cross section at {radical}(s){approx_equal}2 TeV from the EAS-TOP experiment

The proton-air inelastic cross section ({sigma}{sub p-air}{sup inel}) is measured at {radical}(s){approx_equal}2 TeV at the EAS-TOP extensive air shower experiment by studying the absorption length of cosmic ray proton primaries cascades reaching the maximum development at the observation level. Primary energies, in the region E{sub 0}=(1.5 divide 2.5){center_dot}10{sup 15} eV, are selected through the EAS muon number (N{sub {mu}}), and proton originated cascades at maximum development are selected by means of the shower size (N{sub e}). The observed absorption length ({lambda}{sub obs}) is a convolution of the proton-air interaction length ({lambda}{sub p-air}) and of the shower and detector fluctuations. The conversion factor k={lambda}{sub obs}/{lambda}{sub int} is obtained by means of simulations performed with the CORSIKA code and the QGSJET II and SIBYLL interaction models. The obtained value of the p-air inelastic cross section at {radical}(s){approx_equal}2 TeV is {sigma}{sub p-air}{sup inel}=338{+-}21(stat){+-}19(syst)-28(syst) mb. The statistical and systematic uncertainties, as well as the relationships with the pp (pp) total cross section measurements are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-194: Analyzing the Effect of Range Shifter Air Gap On TPS Dose Modeling Accuracy in Superficial PBS Proton Therapy

Purpose: Treatment planning systems (TPS) may not accurately model superficial dose distributions of range shifted proton pencil beam scanning (PBS) treatments. Numerous patient-specific QA tests performed on superficially treated PBS plans have shown a consistent overestimate of dose by the TPS. This study quantifies variations between TPS planned dose and measured dose as a function of range shifter air gap and treatment depths up to 5 cm. Methods: PBS treatment plans were created in the TPS to uniformly irradiate a volume of solid water. One plan was created for each range shifter position analyzed, and all plans utilized identical dose optimization parameters. Each optimized plan was analyzed in the TPS to determine the planned dose at varying depths. A PBS proton therapy system with a 3.5 cm lucite range shifter delivered the treatment plans, and a parallel plate chamber embedded in RW3 solid water measured dose at shallow depths for each air gap. Differences between measured and planned doses were plotted and analyzed. Results: The data show that the TPS more accurately models superficial dose as the air gap between the range shifter and patient surface decreases. Air gaps less than 10 cm have an average dose difference of only 1.6%, whereas air gaps between 10 and 20 cm differ by 3.0% and gaps greater than 20 cm differ by 4.4%. Conclusion: This study has shown that the TPS is unable to accurately model superficial dose with a large range shifter air gap. Dose differences greater than 3% will likely cause QA failure, as many institutions analyze patient QA with a 3%/3mm gamma analysis. For superficial PBS therapy, range shifter positions should be chosen to keep the air gap less then 10 cm when patient setup and gantry geometry allow.

60 APPLIED LIFE SCIENCES↗

Effect of air on energy and rise-time spectra measured by proportional gas counter

Air exerts a negative effect on radiation detection using a gas counter because oxygen contained in air has a high electron attachment coefficient and can trap electrons from electron-ion pairs created by ionization from incident radiation in counting gas. This reduces radiation counts. The present study examined the influence of air on energy and rise-time spectra measurements using a proportional gas counter. In addition, a decompression procedure method was proposed to reduce the influence of air and its effectiveness was investigated. For the decompression procedure, the counting gas inside the gas counter was decompressed below atmospheric pressure before radiation detection. For the spectrum measurement, methane as well as various methane and air mixtures were used as the counting gas to determine the effect of air on energy and rise-time spectra. Results showed that the decompression procedure was effective for reducing or eliminating the influence of air on spectra measurement using a proportional gas counter. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active suppression of air refractive index fluctuation using a Fabry-Perot cavity and a piezoelectric volume actuator

Air refractive index fluctuation ({Delta}n{sub air}) is one of the largest uncertainty sources in precision interferometry systems that require a resolution of nanometer order or less. We introduce a method for the active suppression of {Delta}n{sub air} inside a normal air-environment chamber using a Fabry-Perot cavity and a piezoelectric volume actuator. The temporal air refractive index (n{sub air}) at a local point is maintained constant with an expanded uncertainty of {approx}4.2x10{sup -9} (k=2), a sufficiently low uncertainty for precise measurements unaffected by {Delta}n{sub air} to be made inside a chamber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-precision diode-laser-based temperature measurement for air refractive index compensation

We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements, it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlen equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilizes direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well-matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially nonhomogeneous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using a 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NYSEG Seneca Compressed Air Energy Storage (CAES) Demonstration Project

Compressed Air Energy Storage (CAES) is a hybrid energy storage and generation concept that has many potential benefits especially in a location with increasing percentages of intermittent wind energy generation. The objectives of the NYSEG Seneca CAES Project included: for Phase 1, development of a Front End Engineering Design for a 130MW to 210 MW utility-owned facility including capital costs; project financials based on the engineering design and forecasts of energy market revenues; design of the salt cavern to be used for air storage; draft environmental permit filings; and draft NYISO interconnection filing; for Phase 2, objectives included plant construction with a target in-service date of mid-2016; and for Phase 3, objectives included commercial demonstration, testing, and two-years of performance reporting. This Final Report is presented now at the end of Phase 1 because NYSEG has concluded that the economics of the project are not favorable for development in the current economic environment in New York State. The proposed site is located in NYSEG’s service territory in the Town of Reading, New York, at the southern end of Seneca Lake, in New York State’s Finger Lakes region. The landowner of the proposed site is Inergy, a company that owns the salt solution mining facility at this property. Inergy would have developed a new air storage cavern facility to be designed for NYSEG specifically for the Seneca CAES project. A large volume, natural gas storage facility owned and operated by Inergy is also located near this site and would have provided a source of high pressure pipeline quality natural gas for use in the CAES plant. The site has an electrical take-away capability of 210 MW via two NYSEG 115 kV circuits located approximately one half mile from the plant site. Cooling tower make-up water would have been supplied from Seneca Lake. NYSEG’s engineering consultant WorleyParsons Group thoroughly evaluated three CAES designs and concluded that any of the designs would perform acceptably. Their general scope of work included development of detailed project construction schedules, capital cost and cash flow estimates for both CAES cycles, and development of detailed operational data, including fuel and compression energy requirements, to support dispatch modeling for the CAES cycles. The Dispatch Modeling Consultant selected for this project was Customized Energy Solutions (CES). Their general scope of work included development of wholesale electric and gas market price forecasts and development of a dispatch model specific to CAES technologies. Parsons Brinkerhoff Energy Storage Services (PBESS) was retained to develop an air storage cavern and well system design for the CAES project. Their general scope of work included development of a cavern design, solution mining plan, and air production well design, cost, and schedule estimates for the project. Detailed Front End Engineering Design (FEED) during Phase 1 of the project determined that CAES plant capital equipment costs were much greater than the $\$$125.6- million originally estimated by EPRI for the project. The initial air storage cavern Design Basis was increased from a single five million cubic foot capacity cavern to three, five million cubic foot caverns with associated air production wells and piping. The result of this change in storage cavern Design Basis increased project capital costs significantly. In addition, the development time required to complete the three cavern system was estimated at approximately six years. This meant that the CAES plant would initially go into service with only one third of the required storage capacity and would not achieve full capability until after approximately five years of commercial operation. The market price forecasting and dispatch modeling completed by CES indicated that the CAES technologies would operate at only 10 to 20% capacity factors and the resulting overall project economics were not favorable for further development. As a result of all of these factors, the Phase 1 FEED developed an installed CAES plant cost estimate of approximately $\$$2,300/KW for the 210MW CAES 1A and 2 cycles. The capital cost for the 136 MW CAES 1 cycle was even higher due to the lower generating capacity of the cycle. Notably, the large equipment could have generated additional capacity (up to 270MW) which would have improved the cost per KW; however, the output was limited by the night time transmission system capability. The research herein, therefore, is particular to the site-specific factors that influenced the design and the current and forecasted generation mix and energy prices in Upstate New York and may not necessarily indicate that CAES plants cannot be economically constructed in other places in New York State or the world.

25 ENERGY STORAGE↗

Low-Flow Liquid Desiccant Air Conditioning: General Guidance and Site Considerations

Dehumidification or latent cooling in buildings is an area of growing interest that has been identified as needing more research and improved technologies for higher performance. Heating, ventilating, and air-conditioning (HVAC) systems typically expend excessive energy by using overcool-and-reheat strategies to dehumidify buildings. These systems first overcool ventilation air to remove moisture and then reheat the air to meet comfort requirements. Another common strategy incorporates solid desiccant rotors that remove moisture from the air more efficiently; however, these systems increase fan energy consumption because of the high airside pressure drop of solid desiccant rotors and can add heat of absorption to the ventilation air. Alternatively, liquid desiccant air-conditioning (LDAC) technology provides an innovative dehumidification solution that: (1) eliminates the need for overcooling and reheating from traditional cooling systems; and (2) avoids the increased fan energy and air heating from solid desiccant rotor systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of Vehicle Air Conditioning Pull-Down Period

Air conditioner usage was characterized for high heat-load summer conditions during short driving trips using a 2009 Ford Explorer and a 2009 Toyota Corolla. Vehicles were parked in the sun with windows closed to allow the cabin to become hot. Experiments were conducted by entering the instrumented vehicles in this heated condition and driving on-road with the windows up and the air conditioning set to maximum cooling, maximum fan speed and the air flow setting to recirculate cabin air rather than pull in outside humid air. The main purpose was to determine the length of time the air conditioner system would remain at or very near maximum cooling power under these severe-duty conditions. Because of the variable and somewhat uncontrolled nature of the experiments, they serve only to show that for short vehicle trips, air conditioning can remain near or at full cooling capacity for 10-minutes or significantly longer and the cabin may be uncomfortably warm during much of this time.

42 ENGINEERING↗

SRS environmental air surveillance program 1954-2015: General trends

The radiological monitoring program at SRS was established under the DuPont Company in June 1951 and was used as a measurement of the effectiveness of plant controls and as an authoritative record of environmental conditions surrounding the plant. It also served as a method of demonstrating compliance with applicable federal regulations and guidance. This document serves as a general summary of changes made specifically to the environmental air monitoring program since its inception, and a discussion of the general trends seen in the air monitoring program at SRS from 1954 to 2015. Initially, the environmental air surveillance program focused not only on releases from SRS but also on fallout from various weapons testing performed through the end of 1978. Flypaper was used to measure the amount of fallout in the atmosphere during this period, and was present at each of the 10 monitoring stations. By 1959, all site stacks were included in the air monitoring program to determine their contribution to the airborne radioactivity onsite, and the number of air surveillance samplers rose to 18. This trend of an increased number of sampling locations continued to a peak of 35 sampling locations before shifting to a downward trend in the mid-1990s. In 1962, 4 outer-range samplers were placed in Savannah and Macon, GA, and in Greenville and Columbia, SC. Until 1976, air samplers were simply placed around the perimeter of the various operation locations (after 1959, this included stacks to determine their contribution to the airborne radioactivity), with the intent of creating as representative a distribution as possible of the air surrounding operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LA100 Equity Strategies. Chapter 11: Truck Electrification for Improved Air Quality and Health

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This report focuses on truck electrification as a means to improve air quality and health in traffic and air quality disadvantaged communities. It also identifies potential strategies to more equitably distribute air quality benefits from electrification of trucks, defined here as heavy-duty vehicles over 8,500 pounds (lbs) gross vehicle weight. Specifically, NREL analyzed 1) baseline air pollutant emissions, 2) emissions reductions associated with incremental increases in electrification of three types of heavy-duty trucks in 2035, and 3) resultant changes to air pollutant concentrations for selected census tracts along major roadways in disadvantaged and non-disadvantaged communities for comparison. In addition, NREL analyzed the impact of estimated pollutant concentrations on several health effects and the distribution of those health effects by disadvantaged community status. NREL's analysis is complemented by a University of California Los Angeles (UCLA) analysis of air quality benefits from transportation electrification, which included light-duty vehicles (Chapter 15) and evaluated regional air-quality changes across Los Angeles. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mass transfer coefficients, kL, and air-CO2 ingassing rates in 3.4 m2 and 1-acre raceway ponds.

The US DOE 2016 Billion Ton Update (Langholtz 2016) projected that CO2 in flue-gas from power plants or similar sources would limit U.S. algal biofuel potential to under 5 billion gallons gasoline equivalent (gge) per year, due to lack of sufficient land, water and other requirements near such flue gas sources. 2nd generation carbon capture technologies are proposed to overcome this constraint (Davis 2017), and could expand this resource potential nearly 10-fold, assuming CO2 costs near the future, 2025 DOE NETL, goal of $40/metric ton CO2. An alternative pathway is the direct uptake of air CO2 into the algal ponds through an increase in the air-CO2 transfer rate resulting from the reaction of CO2 with hydroxide ions. However, such a ‘chemical enhancement’ in mass transfer depends on a high pH in the culture, and, by extension, the ability of microalgae to maintain high rates of carbon assimilation under such conditions. Abiotic experiments characterized the air-CO2 mass-transfer rate in 1-acre and 3.4 m2 raceway ponds as a function of pH, with rates approaching 10 g C/m2-day at pH 12 in the brackish water tested, equivalent to a biomass productivity potential of near 20 g AFDW/m2-day (@ 0.47 g C/g AFDW). The mass transfer rate was found to be nearly independent of the mass-transfer coefficient, indicating that at turbulence levels achievable in typical raceway ponds, the system is reaction rate, rather than diffusion limited. In biotic trials with an unknown green microalga, biomass productivity in ponds receiving CO2 from only direct surface air-CO2 exchange averaged 5 +/- 0.5 g AFDW/m2-day in August - September central California conditions, about half-that of experimental controls fertilized with supplemental CO2. pH in the air-only treatment reached a maximum of 10.5, supporting a model predicted air-CO2 ingassing rate between 2-3 g C/m2-day, consistent with the observed biomass carbon assimilation rate. Results suggest that unique alkaliphilic strains are required if reliant on direct in-pond air-CO2 transfer for algal inorganic carbon supply, and that reaching an economically viable biomass productivity will require strains that thrive at pH 11 and above.

09 BIOMASS FUELS↗

Verification of Energy Reduction Effect through Control Optimization of Supply Air Temperature in VRF-OAP System

This paper developed an algorithm that controls the supply air temperature in the variable refrigerant flow (VRF), outdoor air processing unit (OAP) system, according to indoor and outdoor temperature and humidity, and verified the effects after applying the algorithm to real buildings. The VRF-OAP system refers to a heating, ventilation, and air conditioning (HVAC) system to complement a ventilation function, which is not provided in the VRF system. It is a system that supplies air indoors by heat treatment of outdoor air through the OAP, as a number of indoor units and OAPs are connected to the outdoor unit in the VRF system simultaneously. This paper conducted experiments with regard to changes in efficiency and the cooling capabilities of each unit and system according to supply air temperature in the OAP using a multicalorimeter. Based on these results, an algorithm that controlled the temperature of the supply air in the OAP was developed considering indoor and outdoor temperatures and humidity. The algorithm was applied in the test building to verify the effects of energy reduction and the effects on indoor temperature and humidity. Loads were then changed by adjusting the number of conditioned rooms to verify the effect of the algorithm according to various load conditions. In the field test results, the energy reduction effect was approximately 15–17% at a 100% load, and 4–20% at a 75% load. However, no significant effects were shown at a 50% load. The indoor temperature and humidity reached a comfortable level.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Impact of the AIRS Spatial Response on Channel-to-Channel and Multi-Instrument Data Analyses

The Atmospheric Infrared Sounder (AIRS) measures the infrared spectrum in 2378 channels between 3.7 and 15.4 microns with a very high spectral resolution of approximately 1200. AIRS footprints are approximately 1.1 by 0.6 degrees. Because AIRS is a grating spectrometer, each channel has a unique spatial response. Image rotation due to the scan mirror causes these spatial responses to rotate. In effect, each channel has 90 spatial responses, one for each scene footprint in the scan line. Although the spatial response for most channels is symmetric and nearly uniform, some channels have significantly asymmetric response. This paper reviews and describes the prelaunch measurements that characterized the spatial response functions. Next, it describes the conversion of the ground-based results into footprint-specific response functions valid in flight. Then we describe the postlaunch validation of the measurements, including centroid location, axes orientations, and a check on the full two-dimensional response functions. This latter check involves comparison of AIRS data with that of the Moderate Resolution Imaging Spectrometer (MODIS), which flies on the same platform as AIRS. An important result is that AIRS/MODIS brightness temperature comparisons are significantly improved (scatter reduced) when the AIRS spatial response is explicitly taken into account. Finally, a status report is given on attempts to fully verify the prelaunch measurements by deriving the AIRS spatial response from flight data alone.

preflight calibaration↗