Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACCURACY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Evaluation of factors determining the accuracy of linearized subsonic panel methods

A systematic evaluation of the factors determining the accuracy of linearized subsonic panel methods is presented. In particular, the constant and quadratically varying doublet panel methods are compared for thin and thick surface modelings in two and three dimensions. The sensitivity of results to panel edge and control point locations is studied for both of the methods. The first order convergence of the quadratic doublet method near network edges and the subsequent effect on the Kutta condition is investigated. Results from a quadratic doublet method specifically designed for a vector processing computer are shown.

Thomas, J. L.↗

Assessment of relative error sources in IR DIAL measurement accuracy

An assessment is made of the role the various error sources play in limiting the accuracy of infrared differential absorption lidar measurements used for the remote sensing of atmospheric species. An overview is presented of the relative contribution of each error source including the inadequate knowledge of the absorption coefficient, differential spectral reflectance, and background interference as well as measurement errors arising from signal fluctuations.

Menyuk, N.↗

Measuring Tracking Accuracy of CCD Imagers

Tracking accuracy and resolution of charge-coupled device (CCD) imaging arrays measured by instrument originally developed for measuring performance of star-tracking telescope. Operates by projecting one or more artifical star images on surface of CCD array, moving stars in controlled patterns, and comparing star locations computed from CCD outputs with those calculated from step coordinates of micropositioner.

Stanton, R. H.↗

Aerodynamic coefficient identification package dynamic data accuracy determinations: Lessons learned

The errors in the dynamic data output from the Aerodynamic Coefficient Identification Packages (ACIP) flown on Shuttle flights 1, 3, 4, and 5 were determined using the output from the Inertial Measurement Units (IMU). A weighted least-squares batch algorithm was empolyed. Using an averaging technique, signal detection was enhanced; this allowed improved calibration solutions. Global errors as large as 0.04 deg/sec for the ACIP gyros, 30 mg for linear accelerometers, and 0.5 deg/sec squared in the angular accelerometer channels were detected and removed with a combination is bias, scale factor, misalignment, and g-sensitive calibration constants. No attempt was made to minimize local ACIP dynamic data deviations representing sensed high-frequency vibration or instrument noise. Resulting 1sigma calibrated ACIP global accuracies were within 0.003 eg/sec, 1.0 mg, and 0.05 deg/sec squared for the gyros, linear accelerometers, and angular accelerometers, respectively.

Heck, M. L.↗

Update and review of accuracy assessment techniques for remotely sensed data

Research performed in the accuracy assessment of remotely sensed data is updated and reviewed. The use of discrete multivariate analysis techniques for the assessment of error matrices, the use of computer simulation for assessing various sampling strategies, and an investigation of spatial autocorrelation techniques are examined.

Congalton, R. G.↗

Analysis of Subpixel Registration Accuracy

Geometric and probabilistic models for subpixel accuracy are developed. The geometric models bound the error in offset estimation using the pixels in an observed digital straight line. One probabilistic model bounds the estimate of error offset for continuous images. The other model bounds the error for discrete images given that one is in the correct pixel.

Lavine, D.↗

An assessment of the accuracy of orthotropic photoelasticity

The accuracy of orthotropic photoelasticity was studied. The study consisted of both theoretical and experimental phases. In the theoretical phase a stress-optic law was developed. The stress-optic law included the effects of residual birefringence in the relation between applied stress and the material's optical response. The experimental phase had several portions. First, it was shown that four-point bending tests and the concept of an optical neutral axis could be conveniently used to calibrate the stress-optic behavior of the material. Second, the actual optical response of an orthotropic disk in diametral compression was compared with theoretical predictions. Third, the stresses in the disk were determined from the observed optical response, the stress-optic law, and a finite-difference form of the plane stress equilibrium equations. It was concluded that orthotropic photoelasticity is not as accurate as isotropic photoelasticity. This is believed to be due to the lack of good fringe resolution and the low sensitivity of most orthotropic photoelastic materials.

Hyer, M. W.↗

An evaluation of the accuracy of some radar wind profiling techniques

Major advances in Doppler radar measurement in optically clear air have made it feasible to monitor radial velocities in the troposphere and lower stratosphere. For most applications the three dimensional wind vector is monitored rather than the radial velocity. Measurement of the wind vector with a single radar can be made assuming a spatially linear, time invariant wind field. The components and derivatives of the wind are estimated by the parameters of a linear regression of the radial velocities on functions of their spatial locations. The accuracy of the wind measurement thus depends on the locations of the radial velocities. The suitability is evaluated of some of the common retrieval techniques for simultaneous measurement of both the vertical and horizontal wind components. The techniques considered for study are fixed beam, azimuthal scanning (VAD) and elevation scanning (VED).

Koscielny, A. J.↗

Improvements to the Photometric response and positional accuracy of the Yale PDS 2020G microdensitometer

The necessity to incorporate several hardware changes to optimize the Yale PDS 2020G microdensitometer for photometric and astrometric research are discussed. The properties of a new high speed photometer and a positional calibration system are described. The new photometer incorporates a high speed logarithmic analog to digital converter with more than 10 times the resolution of the former system and a cycle time of approximately 50 usec. The positional calibration system monitors the drunkenness of the stages with respect to fixed index lines and enables the correction of the +/- 5 micro stage errors to an accuracy of better than 1 micro.

Lee, J. F.↗

LANDSAT Scene-to-scene Registration Accuracy Assessment

Initial results obtained from the registration of LANDSAT-4 data to LANDSAT-2 MSS data are documented and compared with results obtained from a LANDSAT-2 MSS-to-LANDSAT-2 scene-to-scene registration (using the same LANDSAT-2 MSS data as the base data set in both procedures). RMS errors calculated on the control points used in the establishment of scene-to-scene mapping equations are compared to error computed from independently chosen verification points. Models developed to estimate actual scene-to-scene registration accuracy based on the use of electrostatic plots are also presented. Analysis of results indicates a statistically significant difference in the RMS errors for the element contribution. Scan line errors were not significantly different. It appears that a modification to the LANDSAT-4 MSS scan mirror coefficients is required to correct the situation.

Anderson, J. E.↗

Geometric Accuracy of LANDSAT-4 MSS Image Data

Analyses of the LANDSAT-4 MSS image data of North Georgia provided by the EDC in CTT-p formats reveal that errors of approximately + or - 30 m in the raw data can be reduced to about + or - 55 m based on rectification procedures involving the use of 20 to 30 well-distributed GCPs and 2nd or 3rd degree polynomial equations. Higher order polynomials do not appear to improve the rectification accuracy. A subscene area of 256 by 256 pixels was rectified with a 1st degree polynomial to yield an RMSE sub xy value of + or - 40 m, indicating that USGS 1:24,000 scale quadrangle-sized areas of LANDSAT-4 data can be fitted to a map base with relatively few control points and simple equations. The errors in the rectification process are caused by the spatial resolution of the MSS data, by errors in the maps and GCP digitizing process, and by displacements caused by terrain relief. Overall, due to the improved pointing and attitude control of the spacecraft, the geometric quality of the LANDSAT-4 MSS data appears much improved over that of LANDSAT-1, -2 AND -3.

Welch, R.↗

Improvements in the accuracy and stability of algorithms for the small-disturbance and full-potential equations applied to transonic flows

Numerical techniques that improve the accuracy and stability of algorithms for the small disturbance and full potential equations used to calculate transonic flows are described. For the small disturbance equation, the algorithm improvements are: (1) the use of monotone switches in the type dependent finite differencing, and (2) the use of stable and simple second order accurate spatial differencing; these improvements are for steady and unsteady transonic flows. For the steady full potential equation, the improvement is in the use of a monotone switch in the type dependent finite differencing of an approximate factorization (AF2) algorithm. All these improvements are implemented in present computer codes by making minor coding modifications.

Goorjian, P. M.↗

Accuracy of Three Dimensional Solid Finite Elements

The results of a study to determine the accuracy of the three dimensional solid elements available in NASTRAN for predicting displacements is presented. Of particular interest in the study is determining how to effectively use solid elements in analyzing thick optical mirrors, as might exist in a large telescope. Surface deformations due to thermal and gravity loading can be significant contributors to the determination of the overall optical quality of a telescope. The study investigates most of the solid elements currently available in either COSMIC or MSC NASTRAN. Error bounds as a function of mesh refinement and element aspect ratios are addressed. It is shown that the MSC solid elements are, in general, more accurate than their COSMIC NASTRAN counterparts due to the specialized numerical integration used. In addition, the MSC elements appear to be more economical to use on the DEC VAX 11/780 computer.

Case, W. R.↗

Leak detector for spacecraft testing with high accuracy

It is convenient to measure the leak rate of spacecraft when the spacecraft is kept in its container and the increment of tracer gas, mostly noble gases, in the container air is measured as function of time. In order to meet the specification of the new voluminous spacecraft, a leak detector with high accuracy is required. This is made difficult, because of the natural abundance of noble gases in air, which mean a considerable background exists. A leak detector is described which allows the measurement of an increment of the concentration of a few % using reference gas.

Saenger, G.↗

Meteorological accuracy requirements for aerobraking orbital transfer vehicles

Accuracy requirements for the prediction of atmospheric density for a transfer mission from geosynchronous orbit to low earth orbit using an aerobraking orbital transfer vehicle are presented. Uniform density variations such as would occur seasonally and diurnally were considered as well as density 'pockets' similar to what may have been observed on some of the Space Shuttle Orbiter entry flights. Variations in the lift-to-drag ratio from 0.3 to 1.5 were evaluated, with the values of the ratio of the vehicle weight to the product of the aerodynamic lift coefficient and the aerodynamic reference area ranging from 20 to 100 lb/sq ft. The results of the study indicated no problems for the range of lift-to-drag ratio values considered for uniform density variations of at least + or - 50 percent. However, density 'pockets' created problems if variations of + or - 30 percent from nominal occurred over altitude ranges of 1,000 to 10,000 ft.

Skalecki, L. M.↗

Accuracy and directional sensitivity of the single-wire technique

Multi-orientation of a single-hot-wire is a novel way to measure the three time-mean velocities, the three turbulent normal stresses, and the three turbulent shear stresses. The present study focuses on the accuracy and directional sensitivity of the technique with respect to mean flow velocity orientation to the probe. Results demonstrate relative insensitivity, indicating that the method is a useful cost-effective tool for turbulent flows of unknown dominant flow direction.

Lilley, D. G.↗

Accuracy of relative positioning by interferometry with GPS Double-blind test results

MITES (Miniature Interferometer Terminals for Earth Surveying) observations conducted on December 17 and 29, 1980, are analyzed. It is noted that the time span of the observations used on each day was 78 minutes, during which five satellites were always above 20 deg elevation. The observations are analyzed to determine the intersite position vectors by means of the algorithm described by Couselman and Gourevitch (1981). The average of the MITES results from the two days is presented. The rms differences between the two determinations of the components of the three vectors, which were about 65, 92, and 124 m long, were 8 mm for the north, 3 mm for the east, and 6 mm for the vertical. It is concluded that, at least for short distances, relative positioning by interferometry with GPS can be done reliably with subcentimeter accuracy.

Counselman, C. C., III↗