Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Vacuum laser acceleration of super-ponderomotive electrons using relativistic transparency injection

Abstract Intense lasers can accelerate electrons to very high energy over a short distance. Such compact accelerators have several potential applications including fast ignition, high energy physics, and radiography. Among the various schemes of laser-based electron acceleration, vacuum laser acceleration has the merits of super-high acceleration gradient and great simplicity. Yet its realization has been difficult because injecting free electrons into the fast-oscillating laser field is not trivial. Here we demonstrate free-electron injection and subsequent vacuum laser acceleration of electrons up to 20 MeV using the relativistic transparency effect. When a high-contrast intense laser drives a thin solid foil, electrons from the dense opaque plasma are first accelerated to near-light speed by the standing laser wave in front of the solid foil and subsequently injected into the transmitted laser field as the opaque plasma becomes relativistically transparent. It is possible to further optimize the electron injection/acceleration by manipulating the laser polarization, incident angle, and temporal pulse shaping. Our result also sheds light on the fundamental relativistic transparency process, crucial for producing secondary particle and light sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temporal development of ion beam mean charge state in pulsed vacuum arc ion sources

Vacuum arc ion sources, commonly also known as 'Mevva' ion sources, are used to generate intense pulsed metal ion beams. It is known that the mean charge state of the ion beam lies between 1 and 4, depending on cathode material, arc current, arc pulse duration, presence or absence of magnetic field at the cathode, as well as background gas pressure. A characteristic of the vacuum arc ion beam is a significant decrease in ion charge state throughout the pulse. This decrease can be observed up to a few milliseconds, until a ''noisy'' steady-state value is established. Since the extraction voltage is constant, a decrease in the ion charge state has a proportional impact on the average ion beam energy. This paper presents results of detailed investigations of the influence of arc parameters on the temporal development of the ion beam mean charge state for a wide range of cathode materials. It is shown that for fixed pulse duration, the charge state decrease can be reduced by lower arc current, higher pulse repetition rate, and reduction of the distance between cathode and extraction region. The latter effect may be associated with charge exchange processes in the discharge plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent progress in vacuum-ultraviolet polarization modulation spectroscopy using polarizing undulator at the TERAS BL5 beamline

Polarization modulation spectroscopy using an Onuki-type undulator is a useful technique for circular dichroism study in the vacuum-ultraviolet region. We have been developing the vacuum-ultraviolet circular dichroism (vuv-CD) spectroscopy in TERAS BL5 beamline at AIST. This paper describes recent improvements in our instrumentation and methods of analysis to achieve precise and absolute measurements. The CD signal is usually accompanied by experimental artifacts, and elimination of all possible artifacts is the key issue for making reliable measurements. After improving beamline optical system, light flux monitor, and undulator operation method, the base line shift of the CD spectrum is suppressed less than 3x10{sup -4}. Sample manipulation and data processing procedures are also described and absolute CD spectrum can be obtained even for linear anisotropic sample. These progresses lead to more quantitative comparison of experimental with calculation on vuv-CD spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacuum-UV negative photoion spectroscopy of SF{sub 5}CF{sub 3}

Ion pair formation, generically described as AB{yields}A{sup +}+B{sup -}, from vacuum-UV photoexcitation of trifluoromethyl sulfur pentafluoride, SF{sub 5}CF{sub 3}, has been studied by anion mass spectrometry using synchrotron radiation in the photon energy range of 10-35 eV. The anions F{sup -}, F{sub 2}{sup -}, and SF{sub x}{sup -} (x=1-5) are observed. With the exception of SF{sub 5}{sup -}, the anions observed show a linear dependence of signal with pressure, showing that they arise from ion pair formation. SF{sub 5}{sup -} arises from dissociative electron attachment, following photoionization of SF{sub 5}CF{sub 3} as the source of low-energy electrons. Cross sections for anion production are put on to an absolute scale by calibration of the signal strengths with those of F{sup -} from both SF{sub 6} and CF{sub 4}. Quantum yields for anion production from SF{sub 5}CF{sub 3}, spanning the range of 10{sup -7}-10{sup -4}, are obtained using vacuum-UV absorption cross sections. Unlike SF{sub 6} and CF{sub 4}, the quantum yield for F{sup -} production from SF{sub 5}CF{sub 3} increases above the onset of photoionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vacuum Insulator Development for the Dielectric Wall Accelerator

At Lawrence Livermore National Laboratory, we are developing a new type of accelerator, known as a Dielectric Wall Accelerator, in which compact pulse forming lines directly apply an accelerating field to the beam through an insulating vacuum boundary. The electrical strength of this insulator may define the maximum gradient achievable in these machines. To increase the system gradient, we are using 'High Gradient Insulators' composed of alternating layers of dielectric and metal for the vacuum insulator. In this paper, we present our recent results from experiment and simulation, including the first test of a High Gradient Insulator in a functioning Dielectric Wall Accelerator cell.

43 PARTICLE ACCELERATORS↗

Plasma expansion into vacuum with charge separation effect

Plasma expansion into vacuum and resultant ion acceleration are studied theoretically. A new self-similar solution is found to describe free expansion of a finite plasma mass into vacuum with a full account of charge separation effects. It is argued that the normalized plasma size {lambda} R/{lambda}{sub D} plays the dominant role in determining the whole ion energy spectrum and thus the maximum ion kinetic energy, where R and {lambda}{sub D} are the plasma scale length and the Debye length, respectively. The analytical model is compared with experiments to show excellent agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Boundary effects of electromagnetic vacuum fluctuations on charged particles

The nature of electromagnetic vacuum fluctuations in the presence of the boundary is investigated from their effects on the dynamics of charged particles. These effects may be observable via the velocity fluctuations of the charge particles near the conducting plate, where the effects of vacuum fluctuations are found to be anisotrpoic. The corresponding stochastic equation of motion for the charged particle is also derived under the semiclassical approximation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear Propagation of Crossing Electromagnetic Waves in Vacuum due to Photon-Photon Scattering

We review the theory for photon-photon scattering in vacuum, and some of the proposals for its experimental search, including the results of our recent works on the subject. We then describe a very simple and sensitive proposal of an experiment and discuss how it can be used at the present (HERCULES) and the future (ELI) ultrahigh power laser facilities either to find the first evidence of photon-photon scattering in vacuum, or to significantly improve the current experimental limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

False Vacuum in the Supersymmetric Mass Varying Neutrino Model

We discuss the vacuum structure of the scalar potential in a supersymmetric Mass Varying Neutrinos model. The observed dark energy density is identified with the false vacuum energy and the dark energy scale of order (10{sup -3} eV){sup 4} is understood by gravitationally suppressed supersymmetry breaking scale, F(TeV{sup 2})/M{sub pl}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scanning Kelvin-probe study of the hydrogen-terminated diamond surface in ultrahigh vacuum

Atomic-force and Kelvin-probe microscopies were employed in ultrahigh vacuum to image the surface topography and contact potential of the hydrogen-terminated and unterminated surfaces of diamond. A variation of about 25 meV in the contact potential was measured on a length scale of 20 nm and ascribed to differently orientated surface domains resulting from hydrogen-plasma processing of the sample. Shifts in the work function arising from sample heating in vacuum and the adsorption of C{sub 60} were measured. The Fermi level was found to be 0.7 and 1.1 eV below the valence band maximum for C{sub 60} coverages of 1 and 4 monolayer, respectively.

36 MATERIALS SCIENCE↗

Vacuum-compatible pulse selector for free-electron laser

We developed a vacuum-compatible pulse selector for a free-electron laser. A rotating cylinder with eight apertures in a vacuum is driven by a closed-loop stepping motor system through a magnetically coupled rotary feedthrough. A field programmable gate array is used to synchronize the cylinder rotation with a trigger signal of the accelerator at a maximum repetition rate of 60 Hz. We achieved to select specific pulses from a continuous pulse train of the SPring-8 Compact SASE Source.

43 PARTICLE ACCELERATORS↗

Surface modification of magnetic recording media by filtered cathodic vacuum arc

Surface modification of a magnetic recording medium was accomplished by filtered cathodic vacuum arc (FCVA). The carbon overcoat of thin-film disks was removed by Ar{sup +} ion sputter etching in vacuum to prevent oxidation of the exposed magnetic medium, which was then modified by FCVA carbon plasma under conditions of zero and -100 V pulsed substrate bias. Monte Carlo simulations performed with the T-DYN code, x-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and surface force microscopy (SFM) provided insight into carbon implantation profiles, surface chemical composition, roughness, and nanomechanical properties of the surface-treated magnetic medium. The dependence of surface modification on the FCVA treatment conditions is discussed in the context of T-DYN, XPS, AFM, and SFM results. The findings of this study demonstrate the potential of FCVA to provide overcoat-free magnetic recording media exhibiting oxidation resistance and enhanced nanomechanical properties.

36 MATERIALS SCIENCE↗

Velocity map imaging using an in-vacuum pixel detector

The use of a new type in-vacuum pixel detector in velocity map imaging (VMI) is introduced. The Medipix2 and Timepix semiconductor pixel detectors (256x256 square pixels, 55x55 {mu}m{sup 2}) are well suited for charged particle detection. They offer high resolution, low noise, and high quantum efficiency. The Medipix2 chip allows double energy discrimination by offering a low and a high energy threshold. The Timepix detector allows to record the incidence time of a particle with a temporal resolution of 10 ns and a dynamic range of 160 {mu}s. Results of the first time application of the Medipix2 detector to VMI are presented, investigating the quantum efficiency as well as the possibility to operate at increased background pressure in the vacuum chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of multicomponent ion beams by a vacuum arc ion source with compound cathode

This paper presents the results of time-of-flight mass spectrometry studies of the elemental and mass-to-charge state compositions of metal ion beams produced by a vacuum arc ion source with compound cathode (WC-Co{sub 0.5}, Cu-Cr{sub 0.25}, Ti-Cu{sub 0.1}). We found that the ion beam composition agrees well with the stoichiometric composition of the cathode material from which the beam is derived, and the maximum ion charge state of the different plasma components is determined by the ionization capability of electrons within the cathode spot plasma, which is common to all components. The beam mass-to-charge state spectrum from a compound cathode features a greater fraction of multiply charged ions for those materials with lower electron temperature in the vacuum arc cathode spot, and a smaller fraction for those with higher electron temperature within the spot. We propose a potential diagram method for determination of attainable ion charge states for all components of the compound cathodes.

43 PARTICLE ACCELERATORS↗

DIFFRACTION STUDY ON THE THERMAL STABILITY OF Ti{sub 3}SiC{sub 2}/TiC/TiSi{sub 2} COMPOSITES IN VACUUM

Titanium silicon carbide (Ti{sub 3}SiC{sub 2}) possesses a unique combination of properties of both metals and ceramics, for it is thermally shock resistant, thermally and electrically conductive, damage tolerant, lightweight, highly oxidation resistant, elastically stiff, and mechanically machinable. In this paper, the effect of high vacuum annealing on the phase stability and phase transitions of Ti{sub 3}SiC{sub 2}/TiC/TiSi{sub 2} composites at up to 1550 deg. C was studied using in-situ neutron diffraction. The role of TiC and TiSi{sub 2} on the thermal stability of Ti{sub 3}SiC{sub 2} during vacuum annealing is discussed. TiC reacts with TiSi{sub 2} between 1400-1450 deg. C to form Ti{sub 3}SiC{sub 2}. Above 1400 deg. C, decomposition of Ti{sub 3}SiC{sub 2} into TiC commenced and the rate increased with increased temperature and dwell time. Furthermore, the activation energy for the formation and decomposition of Ti{sub 3}SiC{sub 2} was determined.

36 MATERIALS SCIENCE↗

Simple filtered repetitively pulsed vacuum arc plasma source

A very simple design of cathodic filtered vacuum arc plasma source is proposed. The source without filter has only four components and none of them require precise machining. The source operates in a repetitively pulsed regime, and for laboratory experiments it can be used without water cooling. Despite the simple construction, the source provides high ion current at the filter outlet reaching 2.5% of 400 A arc current, revealing stable operation in a wide pressure range from high vacuum to oxygen pressure up to more than 10{sup -2} mbar. There is no need in complicated power supply system for this plasma source, only one power supply can be used to ignite the arc, to provide the current for the arc itself, to generate the magnetic field in the filter, and provide its positive electric biasing without any additional high power resistance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacuum Studies of a Prototype Composite Coil Dewar for HTSC Transformers

Oak Ridge National Laboratory (ORNL) is collaborating with Waukesha Electric Systems (WES) to develop a high-temperature superconducting (HTSC) utility power transformer with primary and secondary coils cooled by liquid nitrogen. Since the vacuum-insulated cryogenic coil dewar surrounds the magnetic core limb and cannot form a shorted turn, non-conductive materials are required. Two test vessels and a small prototype dewar have been fabricated by Scorpius Space Launch Company with epoxy/fiberglass composites, using their proprietary PRESSURMAXX vessel technology. The effects of pumping time, bakeout temperature, and cryogenic vessel temperature on vacuum outgassing rates have been investigated. Outgassing rates of the individual materials used in vessel construction have also been measured. The results will be scaled up to determine the required pumping capacity for a full-size 25-MVA commercial transformer dewar.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Technical Aspects of a New in Vacuum Transfocator at ESRF Beamline ID11

A tunable X-Ray focusing apparatus based on compound refractive lenses (CRL), referred to as a transfocator, has been installed for monochromatic beam (IAT in air transfocator) two years ago in the second optics hutch at ID11 at the ESRF. By varying the number of lenses in the beam, the energy focused and the focal length can be varied continuously throughout a large range of energies and distances.Based the success of the IAT, an in-vacuum transfocator (IVT) has now been built and installed at ID11.The aim of this poster is to describe and show the mechanical and technical solutions used to design and manufacture this new IVT.The IVT was installed last January in the first optics hutch at ID11. The IVT consists of nine water cooled cartridges containing 1, 2, 4, 8, 16, 32 Be lenses, and 32 and 64 Al lenses, and a protective aperture of Oe 900 {mu}m. The mechanical design is based on a system of pneumatically actuated cartridges with an auto positioning on two stainless steel rods. The vacuum vessel has translations and rotations perpendicular to the beam direction in order to align the axis of the cartridges with the x-ray beam.

43 PARTICLE ACCELERATORS↗