Ultrasonic determination of the elastic constants of the stiffness matrix for unidirectional fiberglass epoxy composites

The elastic constants of a fiberglass epoxy unidirectional composite are determined by measuring the phase velocities of longitudinal and shear stress waves via the through transmission ultrasonic technique. The waves introduced into the composite specimens were generated by piezoceramic transducers. Geometric lengths and the times required to travel those lengths were used to calculate the phase velocities. The model of the transversely isotropic medium was adopted to relate the velocities and elastic constants.

Marques, E. R. C.↗

Measurement of ice accretion using ultrasonic pulse echo techniques

Many figures are given to illustrate the measurement of ice deposition using ultrasonic pulse echo techniques. The basic concept is to measure the thickness of the ice by relating the pulse echo time to the speed of sound. The measurements are made in an icing research tunnel (IRT), where echo patterns are videotaped during icing exposures under a variety of conditions. Typical echo patterns for different types of ice are illustrated. A table summarizing the icing rates measured in the IRT, along with the presence or absence of surface water is also given.

Hansman, R. John, Jr.↗

Ray propagation path analysis of acousto-ultrasonic signals in composites

The most important result was the demonstration that acousto-ultrasonic (AU) energy introduced into a laminated graphite/resin propagates by two modes through the structure. The first mode, along the graphite fibers, is the faster. The second mode, through the resin matrix, besides being slower is also more strongly attenuated at the higher frequencies. This demonstration was accomplished by analyzing the time and frequency domain of the composite AU signal and comparing them to the same for a neat resin specimen of the same chemistry and geometry as the composite matrix. Analysis of the fine structure of AU spectra was accomplished by various geometrical strategies. It was shown that the multitude of narrow peaks associated with AU spectra are the effect of the many pulse arrivals in the signal. The shape and distribution of the peaks is mainly determined by the condition of nonnormal reflections of ray paths. A cepstrum analysis was employed which can be useful in detecting characteristic times. Analysis of propagation modes can be accomplished while ignoring the fine structure.

Kautz, Harold E.↗

Nondestructive ultrasonic characterization of two-phase materials

The development of ultrasonic methods for the nondestructive characterization of mechanical properties of two phase engineering materials are described. The primary goal was to establish relationships between the nonlinearity parameter and the percentage of solid solution phase in two phase systems such as heat treatable aluminum alloys. The acoustoelastic constant was also measured on these alloys. A major advantage of the nonlinearity parameter over that of the acoustoelastic constant is that it may be determined without the application of stress on the material, which makes the method more applicable to inservice nondestructive characterization. The results obtained on the heat treatable 7075 and the work hardenable 5086 and 5456 aluminum alloys show that both the acoustoelastic constant and the acoustic nonlinearity parameter change considerable with the volume fraction of second phase precipitates in these aluminum alloys. A mathematical model was also developed to relate the effective acoustic nonlinearity parameter to volume fraction of second phase precipitates in an alloy. The equation is approximated to within experimental error by a linear expression for volume fractions up to approx. 10%.

Salama, Kamel↗

Acousto-ultrasonic input-output characterization of unidirectional fiber composite plate by SH waves

A unidirectional fiberglass epoxy composite plate specimen is modelled as a homogeneous transversely isotropic continuum plate medium. Acousto-ultrasonic non-contact input-output characterization by tracing SH waves in the continuum is studied theoretically with a transmitting and receiving transducer located on the same face of the plate. It is found that the directional dependence of the phase velocity of the SH waves travelling in the transversely isotropic medium has a significant effect on the delay time as opposed to the phase velocity of the SH wave travelling in an isotropic medium.

Williams, James H., Jr.↗

Energy shadowing correction of ultrasonic pulse-echo records by digital signal processing

Attention is given to a numerical algorithm that, via signal processing, enables the dynamic correction of the shadowing effect of reflections on ultrasonic displays. The algorithm was applied to experimental data from graphite-epoxy composite material immersed in a water bath. It is concluded that images of material defects with the shadowing corrections allow for a more quantitative interpretation of the material state. It is noted that the proposed algorithm is fast and simple enough to be adopted for real time applications in industry.

Kishoni, D.↗

Measurement of the degree of cure in epoxies with ultrasonic velocity

The use of ultrasonic longitudinal velocity values to measure the degree of cure (defined for an epoxide system as the concentration of epoxide/amine bonds divided by the initial epoxide concentration) in epoxy resins is investigated. The experimental setup used to measure the changes in longitudinal velocity with time is described, together with the technique used to calculate the degree of cure from the acoustic data, using the principle of additive module. Measurements were done with diglycidyl ether of bisphenol A epoxy resin cured with an amine adduct agent. Good qualitative agreement was shown between the time dependence of the acoustically measured degree of cure and the predicted rate of reaction.

Winfree, W. P.↗

Correlation of Ultrasonic Polar Backscatter with the Deply Technique for Assessment of Impact Damage in Composite Laminates

Ultrasonic polar backscatter, a quantitative NDE technique introduced by O'Donnell and Miller (1981), was used to characterize impact damages in a 16-ply graphite-epoxy laminate. The results were correlated with the results obtained by the destructive deply technique of Freeman (1984). The size, shape, and orientation of damage correlated well between the polar backscatter technique and the deply technique. There was good quantitative correlation between the areas of damage indicated by the two techniques, suggesting that the polar backscatter technique is sensitive to specific orientations of damage. The polar backscatter technique provides a good qualitative image of the size and shape of the largest zone of damage in each of the principal orientations; a quantitative estimate of the extent of these largest damage zones can then be obtained.

Blodgett, E. D.↗

Three-Dimensional Ultrasonic Imaging Of The Cornea

Proposed technique generates pictures of curved surfaces. Object ultrasonically scanned in raster pattern generated by scanning transmitter/receiver. Receiver turned on at frequent intervals to measure depth variations of scanned object. Used for medical diagnoses by giving images of small curved objects as cornea. Adaptable to other types of reflection measurementsystems such as sonar and radar.

Heyser, Rrichar C.↗

Transply crack density detection by acousto-ultrasonics

The acousto-ultrasonic method was applied to a PMR-15 8-harness, satin Celion 3000 fabric composite to determine the extent of transply cracking. A six-ply 0/90 laminate was also subjected to mechanical loading, which induced transply cracking. The stress wave factor (SWF) is defined as the energy contained in the received signal from a 2.25-MHz center frequency transducer. The correlation of the SWF with transply crack density is shown.

Hemann, John H.↗

Acousto-ultrasonic input-output characterization of unidirectional fiber composite plate by SV waves

A unidirectional fiberglass epoxy compostie specimen is modelled as a homogeneous transversely isotropic continuum plate medium. Acousto-ultrasonic noncontact input-output characterization is studied theoretically with a transmitting and a receiving transducer located on the same face of the plate. The single reflection problem for an incident SV wave at a plane boundary in transversely isotropic medium is analyzed. An obliquely incident SV wave results in a reflected SV wave and a reflected P wave for an angle of incidence of the incident SV wave less than the critical angle. Otherwise, there exists only an SV wave in the medium as the reflected P wave degenerates into a surface wave travelling parallel to the plane boundary. The amplitude ratio of the reflected SV wave is -1 when the angle of incidence is greater than or = the critical angle. The directional dependence of the phase velocity of the SV wave propagating in the transversely isotropic medium has a significant effect on the delay time, as opposed to the directional independence of the phase velocity of a shear wave propagating in an isotropic medium. The displacements associated with the SV wave in the plate and which may be detected by the noncontact receiving transducer are approximated by an asymptotic solution for an infinite transversely isotropic medium subjected to a harmonic point load.

Liao, Peter↗

New acousto-ultrasonic techniques applied to aerospace materials

The use of an NdYAG pulsed laser for generating ultrasonic waves for NDE in resin matrix composites was investigated. A study was conducted of the use of the 1.064 micron wavelength NdYAG pulsed laser with the neat, unreinforced resin as well as graphite fiber/polymer composite specimens. In the case of the neat resins it was found that, at normal incidence, about 25 percent of the laser pulse energy was reflected at the incident surface. An attenuation coefficient for the polyimide resin, PMR-15 was determined to be approximately 5.8 np/cm. It was found in energy balance studies that graphite fiber/polymer specimens attenuate the laser beam more than do neat resins. The increase absorption is in the graphite fibers. The occurrence of laser induced surface damage was also studied. For the polymer neat resin, damage appears as pit formation over a small fraction of the pulse impact area and discoloration over a larger part of the area. A damage threshold was inferred from observed damage as a function of pulse energy. The 600 F cured PMR-15 and PMR-11 exhibit about the same amount of damage for a given laser pulse energy. The damage threshold is between 0.06 and 0.07 J/sq cm.

Kautz, Harold E.↗

Acousto-ultrasonics as a monitor of material anisotropy

This paper discusses experimental results obtained by performing the acousto-ultrasonic (AU) method at various azimuthal angles on the surface of fiber-reinforced composite plates. The use of an IBM-PC/data-acquisition board to obtain a digitized AU signal to be analyzed by specially developed software is described. An introduction is given to the use of AU parameters to quantify information evidenced in amplitude/frequency plots. A description of how the parameters are obtained by calculating various spectral moments and the area under particular ranges of the spectral density curve is presented. Results are given from voltage/time plots, amplitude/frequency plots, and plots showing the variation of calculated AU parameters with azimuthal angle. Finally, how the variation of AU parameters with azimuthal angle may be related to variation in material properties with azimuthal angle is discussed.

Duke, J. C., Jr.↗

Physical principles of ultrasonic non-destructive evaluation of advanced composites

Results are presented from the continued investigations into the use of ultrasonic measurement techniques for the detection and characterization of porosity. The effects that bleeder cloth impressions (left after the cure process) have on the capability of polar backscatter to interrogate volume effects such as porosity are described. Some preliminary data regarding a comparison of phase sensitive and phase insensitivie detection for materials characterization is presented.

Miller, James G.↗

Ultrasonic depth gauge for liquids under high pressure

An ultrasonic depth gauge 20 for liquids under high pressure is comprised of a transducer assembly 21 and a supporting electronics unit 22. The transducer assembly is mounted into the bottom wall of a storage vessel 12 with its resonating surface directly exposed to the highly pressurized liquid 13 in the vessel. The transducer assembly consists of a conventional transducer element 38 rigidly bonded to the inside wall of a bored out conventional high-pressure plug 30 thereby forming a composite resonator 50. The element and the plug wall resonate as one upon electrical excitation of the element while the transducer element is completely shielded from any exposure to the liquid under high pressure. The composite resonator sends a vibration up to the surface of the liquid where it is reflected back to the composite resonator. The supporting electronics unit measures the vibrations round-trip transit time which is proportional to the depth 15 of the liquid.

Allan J Zuckerwar↗

Pulse shaping and extraction of information from ultrasonic reflections in composite materials

The application of ultrasonic inspection to the nondestructive testing of composite materials is examined with reference to specific examples including monitoring of epoxy curing, evaluation of impact damage in a graphite/epoxy laminate, and monitoring of a repaired area in a composite wing plate. Signal processing methods are described which improve time resolution, facilitating identification of discrete echoes corresponding to events in the material.

Kishoni, Doron↗

Screening of metal matrix composites using ultrasonic C-scans

Ultrasonic C-scans can be used to find some types of defects in continuous fiber-reinforced metal matrix composites such as boron/aluminum composites. These defects are related to the fatigue behavior and fracture location of each inspected specimen. The C-scan technique determined the relative amount of defects in boron/aluminum composites. The defects were primarily identified as gaps in the fiber spacing. Those specimens with higher defect densities had shorter fatigue lives, lower fatigue endurance limits, and greater reductions in the elastic unloading modulus (that is, stiffness) because of fatigue cycling. This type of data could be used to set accept/reject levels for a composite panel based on C-scan indications.

Johnson, W. S.↗