Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Recent evolutions in the LTDP CDF project

In the latest years, CNAF (the national center of the Italian Institute for Nuclear Physics INFN dedicated to Research and Development on Information and Communication Technologies) has been working on the Long Term Data Preservation (LTDP) project for the CDF experiment, active at Fermilab from 1990 to 2011. The main aims of the project are to protect the most relevant part of the CDF RUN-2 data collected between 2001 and 2011 and already stored on tape at CNAF (4 PB), as well as to ensure the availability and the access to the analysis facility to those data over time. Lately, the CDF database, hosting information about CDF datasets such as their structure, file locations and metadata, has been imported from Fermilab to CNAF. Also, the Sequential Access via Metadata (SAM) station data handling tool for CDF data management, that allows to manage data transfers and to retrieve information from the CDF database, has been properly installed and configured at CNAF. This was a fundamental step in the perspective of a complete decommissioning of CDF services on Fermilab side. An access system has been designed and tested to submit CDF analysis jobs, using CDF software distributed via CERN Virtual Machine File System (CVMFS) and requesting delivery of CDF files stored on CNAF tapes, as well as data present only on Fermilab storage archive. Moreover, the availability and the correctness of all CDF data stored on CNAF tapes has been verified. This paper describes all these recent evolutions in detail, presenting the future plans for the LTDP project at CNAF.

Fornari, Federico↗

Indicator-directed Dynamic Power Management for Iterative Workloads on GPU-Accelerated Systems

Modern high-performance and warehouse computing centers show strong interest in minimizing system power consumption while satisfying customers’ quality of service (QoS). Dynamic voltage and frequency scaling (DVFS) is effective for achieving this goal. Nevertheless, automating the process online and making it transparent to users must address three major challenges: (1) Complexity — today’s hardware components (e.g., CPUs, GPUs, memory, network, etc.) can be configured in several or dozens of frequency/voltage states for satisfying divergent system demands. Given their combination and the emergence of heterogeneity, searching the optimal configuration in the design space online can be timing consuming. (2) QoS guarantee — user-defined objectives such as power constraint and performance target must be monitored, predicted and ensured at the best effort. (3) Adaptability — various known and unknown workloads run on systems. Workloads characteristics should be quickly determined and configurations dynamically adjusted in accord with workloads and QoS. In this work, we focus on applications exhibiting an interesting feature – iterative or periodic, which is common among conventional HPC and emerging machine learning workloads. We propose an online dynamic power-performance (ODPP) management framework to dynamically adjust GPU DVFS configurations to meet performance and power objectives and constraints, without any code annotation or intrusion. Particularly, ODPP extracts the performance and power indicators for applications from their resources utilization profiles in a short episode. It further automatically constructs an accurate model that infers from the indicators how the application's performance and power vary with GPU core and memory frequencies. Aided with the model, for both seen and unseen applications, ODPP can quickly determine the most appropriate DVFS configuration for their execution. We evaluate ODPP on an NVIDIA GPU using multiple exascale computing (ECP) and deep learning applications.

Zou, Pengfei↗

Predicting runtime and resource utilization of jobs on integrated cloud and HPC systems

Recent advances in virtualization technologies used in cloud computing offer performance that closely approaches bare-metal levels. Combined with specialized instance types and high-speed networking services for cluster computing, cloud platforms have become a compelling option for high-performance computing (HPC). However, most current batch job schedulers in HPC systems are designed for homogeneous clusters and make decisions based on limited information about jobs and system status. Scientists typically submit computational jobs to these schedulers with a requested runtime that is often over- or under-estimated. More accurate runtime predictions can help schedulers make better decisions and reduce job turnaround times. Here, they can also support decisions about migrating jobs to the cloud to avoid long queue wait times in HPC systems.

97 MATHEMATICS AND COMPUTING↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrodialysis: An effective methodology to purify the leachate of spent Li-ion batteries

The electrification of transportation and the transition of society towards low or net-zero carbon emissions has led to a skyrocketing global demand for Li-ion batteries. After a service life of three to ten years, Li-ion batteries have less than 80 % of their initial capacities and draw near to the end of their lives for practical utilization. Due to potential supply chain shortages and the value embodied in Li-ion batteries, it is imperative to recycle them, to recover the materials, and to improve the circularity and the sustinability of the industry. How to cost-effectively purify spent batteries while reducing time, energy, and waste emissions is a challenge faced by Li-ion battery recyclers. The first electrochemical membrane reactor reported in our group hasa high selectivity towards lower Cu 2+ , Al 3+ and Fe 3+ ions (<5 ppm) and retains >95% of the Ni 2+ , Co 2+ and Mn 2+ ions in the leachate. An advanced electrochemical membrane reactor was developed in this study. Further, not only does the new reactor have the same selectivity as the original reactor, but other advantages including a faster leachate processing rate (up to 10X faster). The advanced reactor can also directly generate acid at the anode side; eliminating the reactor restoration step. The prominent advantages that this electrodialysis technology has over chemical-precipitation methods include: (1) ion recovery efficiencies do not diminish after removing the impurities, Ni 2+ , Co 2+ and Mn 2+ , even at a higher initial Ni 2+ ion concentrations; in comparison, chemical precipitation has Ni 2+ , Co 2+ and Mn 2+ ion recovery efficiencies reduced significantly when the initial Ni 2+ , Co 2+ and Mn 2+ ion concentrations increase. (2) electrodialysis does not change the concentrations of Ni 2+ , Co 2+ and Mn 2+ ions significantly, but chemical precipitation could reduce Ni 2+ and Co 2+ ions to less than half of their initial values. Through electro-dialyzing the leachate, the H 2 evolution reaction mechanism was found to switch from the Volmer-acid Heyrovsky mechanism to the Volmer-alkaline Heyrovsky mechanism at a pH of around 3.7.

25 ENERGY STORAGE↗

Meteorological services annual data report for 2019

This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2019. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

54 ENVIRONMENTAL SCIENCES↗

Meteorological services annual data report for 2020

This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2020. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

54 ENVIRONMENTAL SCIENCES↗

Meteorological Services Annual Data Report for 2021

This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2021. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

54 ENVIRONMENTAL SCIENCES↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Meteorological Services Annual Data Report for 2022

This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2022. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

54 ENVIRONMENTAL SCIENCES↗

Meteorological Services Annual Data Report for 2023

This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2023. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

54 ENVIRONMENTAL SCIENCES↗

Meteorological Services Annual Data Report for 2024

This document presents the meteorological data collected at Brookhaven National Laboratory (BNL) by Meteorological Services (Met Services) for the calendar year 2024. The purpose is to publicize the data sets available to emergency personnel, researchers and facility operations. Met services has been collecting data at BNL since 1949. Data from 1994 to the present is available in digital format. Data is presented in monthly plots of one-minute data. This allows the reader the ability to peruse the data for trends or anomalies that may be of interest to them. Full data sets are available to BNL personnel and to a limited degree outside researchers. The full data sets allow plotting the data on expanded time scales to obtain greater details (e.g., daily solar variability, inversions, etc.).

54 ENVIRONMENTAL SCIENCES↗

Impedance-Based Prediction of SSR-Generated Harmonics in Doubly-Fed Induction Generators

Doubly-fed induction generators (DFIGs) are prone to subsynchronous resonance (SSR) with series-compensated transmission lines and experiencing SSR-generated harmonics of wide-ranging magnitudes. This paper presents a large-signal impedance-based approach for the prediction of the magnitude of SSR-generated harmonics in DFIGs. Note that the large-signal impedance of a network shows variation in its impedance response with the magnitude of perturbation at its terminals. It is discovered in this paper that the impedance of a series-compen- sated transmission line starts changing with the magnitude of SSR because of the metal-oxide varistor-based protection of series capacitors in the line. The changing line impedance halts the growth of the SSR beyond a certain point, where the DFIG forms a limit-cycle mode and emits harmonics at the SSR frequency. The discovered role of the protection of series capacitors in SSR not only enables the prediction of SSR-generated harmonics but also can be used for the timely detection of an SSR event to avoid system disruption and sudden loss of bulk generation. The large- signal impedance-based prediction of SSR-generated harmonics in DFIG-based wind and hydro generators is demonstrated using numerical simulations of a 2.5-MVA, 690-V DFIG supplying to a series-compensated transmission line.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Evolving radon diffusion through earthen barriers at uranium waste disposal sites

Field measurements of Rn-222 fluxes from the tops and bottoms of compacted clay radon barriers were used to calculate effective Rn diffusion coefficients (D Rn ) at four uranium waste disposal sites in the western United States to assess cover performance after more than 20 years of service. Values of D Rn ranged from 7.4 × 10 -7 to 6.0 × 10 -9 m 2 /s, averaging 1.42 × 10 -7 . Water saturation (S W ) from soil cores indicated that there was relatively little control of D Rn by S W , especially at higher moisture levels, in contrast to estimates from most steady-state diffusion models. Further, this is attributed to preferential pathways intrinsic to construction of the barriers or to natural process that have developed over time including desiccation cracks, root channels, and insect burrows in the engineered earthen barriers. A modification to some models in which fast and slow pathway D Rn values are partitioned appears to give a good representation of the data; 4% of the fast pathway was needed to fit the data regression. For locations with high S w and highest D Rn (and fluxes) at each site, the proportion of fast pathway ranged from 1.7% to 34%, but for many locations with lower fluxes, little if any fast pathway was needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hierarchical Control of Utility-Scale Solar PV Plants for Mitigation of Generation Variability and Ancillary Service Provision

This paper presents a hierarchical control system to mitigate the variability of solar photovoltaic (PV) power plant and provide ancillary services to the electric grid without the need for additional non-solar resources. With coordinated management of each inverter in the system, the control system commands the power plant to proactively curtail a small fraction of its instantaneous maximum power potential, which gives the plant enough headroom to ramp up production from the overall power plant, for a service such as regulation reserve. This control system is practical for continuously changing cloud cover conditions in partially cloudy days. A case study from a site in Hawaii with one-second resolution solar irradiance data is used to verify the efficacy of the proposed control system. The proposed control algorithm is subsequently compared with the alternative control technology from the literature, the grouping control algorithm; the results show that the proposed hierarchical control system is over 10 times more effective in reducing generator mileage to support power fluctuations from solar PV power plants.

14 SOLAR ENERGY↗

Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States

This report is one in a series of Electrification Futures Study (EFS) publications. The EFS is a multiyear research project to explore potential widespread electrification in the future energy system of the United States. Electrification is defined as the substitution of electricity for direct combustion of non-electricity-based fuels used to provide similar services. The EFS is specifically designed to examine electric technology advancement and adoption for end uses in the major economic sectors of the United States, electricity consumption growth and load profiles, future power system infrastructure development and operations, and economic and environmental implications of electrification. Because of the expansive scope and the multiyear duration of the study, research findings and supporting data will be published as a series of reports, with each report being released on its own time frame.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗