Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

MACH 3: Past and future approaches to intelligent tutoring

In 1986, the U.S. Army Research Institute created an intelligent tutoring system as a proof-of-concept for artificial intelligence applications in Army training. The Maintenance Aid Computer HAWK Intelligent Institutional Instructor (MACH 3) taught student mechanics to maintain and troubleshoot the AN/MPQ-57 High Power Illuminator Radar (HPIR) of the HAWK Air Defense Missile System. In 1989, TRADOC Analysis Command compared the effectiveness of MACH 3 to traditional paper-based troubleshooting drills. For the study, all students received lecture and hands-on training as usual. However, during troubleshooting drills, students traced faults using either MACH 3 or the traditional paper-based method. Class records showed that the MACH 3 group completed significantly more troubleshooting tasks and progressed through tasks of greater difficulty than the paper-based group. Upon completion of training, students took written, practical, and oral essay tests. Mean test scores showed that students performed similarly regardless of the drill method used. However, significantly different standard deviations showed that the MACH 3 group performed more consistently than the paper-based group. Furthermore, significantly different time measures showed that the MACH 3 group reached faster troubleshooting solutions on the actual radar transmitter than the paper-based group. We will present the study results and discuss how updating the design of the MACH 3 can include desktop computing in a virtual environment.

Acchione-Noel, Sylvia↗

Nozzle Flow with Vibrational Nonequilibrium

Flow of nitrogen gas through a converging-diverging nozzle is simulated. The flow is modeled using the Navier-Stokes equations that have been modified for vibrational nonequilibrium. The energy equation is replaced by two equations. One equation accounts for energy effects due to the translational and rotational degrees of freedom, and the other accounts for the affects due to the vibrational degree of freedom. The energy equations are coupled by a relaxation time which measures the time required for the vibrational energy component to equilibrate with the translational and rotational energy components. An improved relaxation time is used in this thesis. The equations are solved numerically using the Steger-Warming flux vector splitting method and the Implicit MacCormack method. The results show that uniform flow is produced outside of the boundary layer. Nonequilibrium exists in both the converging and diverging nozzle sections. The boundary layer region is characterized by a marked increase in translational-rotational temperature. The vibrational temperature remains frozen downstream of the nozzle, except in the boundary layer.

Landry, John Gary↗

Development of a real-time transport performance optimization methodology

The practical application of real-time performance optimization is addressed (using a wide-body transport simulation) based on real-time measurements and calculation of incremental drag from forced response maneuvers. Various controller combinations can be envisioned although this study used symmetric outboard aileron and stabilizer. The approach is based on navigation instrumentation and other measurements found on state-of-the-art transports. This information is used to calculate winds and angle of attack. Thrust is estimated from a representative engine model as a function of measured variables. The lift and drag equations are then used to calculate lift and drag coefficients. An expression for drag coefficient, which is a function of parasite drag, induced drag, and aileron drag, is solved from forced excitation response data. Estimates of the parasite drag, curvature of the aileron drag variation, and minimum drag aileron position are produced. Minimum drag is then obtained by repositioning the symmetric aileron. Simulation results are also presented which evaluate the affects of measurement bias and resolution.

Gilyard, Glenn↗

A LiF silicon sandwich counter to measure water content of planetary surfaces

The neutron counter proposed here has a long history and was commercially available in a somewhat different form. This counter would be suitable for a rover or lander since it requires a rather long measuring time for each placement. It consists of two silicon wafer charged-particle counters with a layer of Li-6F deposited on the inner surface of one. The neutron detecting reaction is Li-6(n,H-3)He-4 in which the alpha particle and the triton are emitted from the Li-6 deposit back to back. If one of the detectors sees the alpha particle, the other will see the triton. This allows one to use a coincidence technique that virtually eliminates all background. The signals from each detector can be added together so that the total energy of the reaction, Q=4.6 MeV and the kinetic energy of the neutron, can be recorded.

Drake, D. M.↗

The Flux and Energy Spectra of the Protons in the Inner Van Allen Belt

A cylindrical stack of G-5 nuclear emulsions housed in the payload section of a four-stage research rocket was flown into the northern edge of the inner Van Allen belt on September 19, 1960. The experimental design permitted, for the first time, measurements of the particle fluxes and energy spectra as functions of position along the rocket trajectory. Eight points along the trajectory have been selected for analysis. Results are presented herein for three of these points, and they are discussed in the light of various theories on the trapped radiation.

Naugle, John E.↗

Distribution of Halon-1211 in the Upper Troposphere and Lower Stratosphere and the 1994 Total Bromine Budget

We report here on the details of the first, in situ, real-time measurements of H-1211 (CBrClF2) and sulfur hexafluoride (SF6) mixing ratios in the stratosphere up to 20 km. Stratospheric air was analyzed for these gases and others with a new gas chromatograph, flown aboard a National Aeronautics and Space Administration ER-2 aircraft as part of the Airborne Southern Hemisphere Ozone Experiment/Measurements for Assessing the Effects of Stratospheric Aircraft mission conducted in 1994. The mixing ratio of SF6, with its nearly linear increase in the troposphere, was used to estimate the mean age of stratospheric air parcels along the ER-2 flight path. Measurements of H-1211 and mean age estimates were then combined with simultaneous measurements of CFC-11 (CCl3F), measurements of brominated compounds in stratospheric whole air samples, and records of tropospheric organic bromine mixing ratios to calculate the dry mixing ratio of total bromine in the lower stratosphere and its partitioning between organic and inorganic forms. We estimate that the organic bromine-containing species were almost completely photolyzed to inorganic species in the oldest air parcels sampled. Our results for inorganic bromine are consistent with those obtained from a photochemical, steady state model for stratospheric air parcels with CFC- I I mixing ratios greater than 150 ppt. For stratospheric air parcels with CFC-11 mixing ratios less than 50 ppt (mean age greater than or equal to 5 years) we calculate inorganic bromine mixing ratios that are approximately 20% less than the photo-chemical, steady state model. There is a 20% reduction in calculated ozone loss resulting from bromine chemistry in old air relative to some previous estimates as a result of the lower bromine levels.

Wamsley, P. R.↗

Structural Loading on the QCM/SAW Instrument Aboard the ER-2 Used for Atmospheric Testing

Several experiments have been proposed to capture and evaluate samples of the atmosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) / surface acoustical wave (SAW) instrument installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000-70,000 feet. The primary use of the ER-2 is by NASA for Earth resources to test new sensor systems before being placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above the sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. The purpose of some of the experiments is to extinct data from the atmosphere around the ER-2. For the current CSTEA flight experiment, the housing of the QCM is in a frame that connects to an outer pod that attaches to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM output data is based on the determination of beat frequencies between a pair of oscillators (one coated, the second uncoated, according to the chemical reaction being monitored). A structural analysis of this system can indicate whether potential resonances may exist between the (higher) structural modal frequencies and the beat frequencies. In addition undesirable deformations may result due to maximum expected static or dynamic loads during typical flight conditions. If the deformations are excessive they may adversely affect the accuracy the instrumentation output.

Bainum, Peter M.↗

Controlling Chaos Via Knowledge of Initial Condition for a Curved Structure

Nonlinear response of a flexible curved panel exhibiting bifurcation to fully developed chaos is demonstrated along with the sensitivity to small perturbation from the initial conditions. The response is determined from the measured time series at two fixed points. The panel is forced by an external nonharmonic multifrequency and monofrequency sound field. Using a low power time-continuous feedback control, carefully tuned at each initial condition, produces large long-term effects on the dynamics toward taming chaos. Without the knowledge of the initial conditions, control may be achieved by destructive interference. In this case, the control power is proportional to the loading power. Calculation of the correlation dimension and the estimation of positive Lyapunov exponents, in practice, are the proof of chaotic response.

Maestrello, L.↗

Solid-Liquid Interface Characterization Hardware

The objective is to develop enabling technology to characterize the solid-liquid interface during directional solidification to unprecedented levels with real-time measurement hardware. Existing x-ray imaging hardware is combined with compact Seebeck furnaces and thermal profiling hardware, under development, to accomplish the measurements. Furnace thermal profiles are continuously measured in addition to the sample characteristics.

Peters, Palmer N.↗

Structural Analysis of the QCM Aboard the ER-2

As a result of recent supersonic transport (SST) studies on the effect they may have on the atmosphere, several experiments have been proposed to capture and evaluate samples of the stratosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000 - 70,000 feet. The ER-2 is primarily used by NASA for Earth resources to test new sensor systems before they are placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. Some of the experiments are designed to extract data from the atmosphere around the ER-2. For the current flight experiment, the QCM is housed in a frame that is connected to an outer pod that is attached to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM is a frequency induced instrument. Therefore, a structural analysis of the instrument within the frame is imperative to determine if resonance and/or undesirable deformations occur.

Jones, Phyllis D.↗

Combustion Sensors: Gas Turbine Applications

This report documents efforts to survey the current research directions in sensor technology for gas turbine systems. The work is driven by the current and future requirements on system performance and optimization. Accurate real time measurements of velocities, pressure, temperatures, and species concentrations will be required for objectives such as combustion instability attenuation, pollutant reduction, engine health management, exhaust profile control via active control, etc. Changing combustor conditions - engine aging, flow path slagging, or rapid maneuvering - will require adaptive responses; the effectiveness of such will be only as good as the dynamic information available for processing. All of these issues point toward the importance of continued sensor development. For adequate control of the combustion process, sensor data must include information about the above mentioned quantities along with equivalence ratios and radical concentrations, and also include both temporal and spatial velocity resolution. Ultimately these devices must transfer from the laboratory to field installations, and thus must become low weight and cost, reliable and maintainable. A primary conclusion from this study is that the optics-based sensor science will be the primary diagnostic in future gas turbine technologies.

Human, Mel↗

Interaction of Porosity with a Planar Solid/Liquid Interface

In this paper, an investigation of the interaction between gas porosity and a planar solid/liquid (SL) interface is reported. A two-dimensional numerical model able to accurately track sharp SL interfaces during solidification of pure metals and alloys is proposed. The finite difference method and a rectangular undeformed grid are used for computation. The SL interface is described through the points of intersection with the grid lines. Its motion is determined by the thermal and solute gradients at each particular point. Changes of the interface temperature because of capillarity or solute redistribution as well as any perturbation of the thermal and solute field produced by the presence of non-metallic inclusions can be computed. To validate the model, the dynamics of the interaction between a gas pore and a solidification front in metal alloys was observed using a state of the art X-ray Transmission Microscope. The experiments included observation of the distortion of the SL interface near a pore, real-time measurements of the growth rate and the change in shape of the porosity during interaction with an advancing SL interface in pure Al and Al-0.25 wt% Au alloy. In addition, porosity induced solute segregation patterns surrounding a pore were also quantified.

Catalina, Adrian V.↗

Detecting Near-Surface Water and Hydrate Minerals on Mars from a Rover, Penetrator, or Borehole: The HYDRA Instrument

One of the major goals of near term NASA Mars exploration is to identify exact locations of near-surface water or hydrated minerals on Mars. Evidence for the existence of recent nearsurface water on Mars underscores the need for developing instrumentation that can identify water or hydrated minerals very near the surface. Further encouraging evidence of surface and near-surface water and hydrate minerals on Mars comes from neutron spectrometer measurements aboard Mars Odyssey. Preliminary results show very large regions of high hydrogen content poleward of 60 deg. latitude, as well as interesting features closer to the equator. However, spatial resolution from orbit is very poor, approx. 400 km. The next logical step is to use in-situ or near-surface investigations to map in detail some of the most interesting features. Relatively simple instrumentation based on He-3 gas proportional counters were shown to be highly successful on the Lunar Prospector mission in identifying even low levels of enhanced hydrogen abundances. Here we discuss HYDRA, a water- and hydrate-sensing instrument currently being developed under the NASA Mars Instrument Development Program (MIDP). HYDRA is based on Lunar Prospector technology, and is intended as a rover body-mounted instrument, or an instrument on an aerobot, penetrator, hard lander on the surface of Mars, or for borehole stratigraphy applications. Our proposed instrument would be ideal for such platforms as it would be small (less than 7 cm diameter by 10 cm long), low mass (less than 500 g), low power (less than 1W), and have a low data volume per measurement. We use neutron spectrometry (a) because of its proven ability to uniquely detect and quantify hydrogen abundance, and (b) because the resources required by this approach (weight, power, size, telemetry bandwidth, and measurement time) are extremely low. This compact neutron spectrometer package, comprised of two small He-3 gas proportional counters, offers superior sensitivity, extensive flight heritage, and inherent ruggedness. These tubes have survived approx. 1500 g's of acceleration in penetrator tests. In a landed application, HYDRA would help address many topics of interest to the Mars Exploration and Astrobiology communities: (a) nature and origin of stratified deposits; (b) water cycle(s) and temporal changes; (c) early water oceans, aquifers, precipitation; (d) current extent/location/state of water; (e) polar cap processes and temporal changes; (f) where extremeophiles could survive on Mars; (g) paleoclimate surface signatures and modeling; (h) strategies for future Mars exploration.

R C Elphic↗

Planets Around Neutron Stars

The objective of this proposal was to continue investigations of neutron star planetary systems in an effort to describe and understand their origin, orbital dynamics, basic physical properties and their relationship to planets around normal stars. This research represents an important element of the process of constraining the physics of planet formation around various types of stars. The research goals of this project included long-term timing measurements of the planets pulsar, PSR B1257+12, to search for more planets around it and to study the dynamics of the whole system, and sensitive searches for millisecond pulsars to detect further examples of old, rapidly spinning neutron stars with planetary systems. The instrumentation used in our project included the 305-m Arecibo antenna with the Penn State Pulsar Machine (PSPM), the 100-m Green Bank Telescope with the Berkeley- Caltech Pulsar Machine (BCPM), and the 100-m Effelsberg and 64-m Parkes telescopes equipped with the observatory supplied backend hardware.

Wolszczan, Alexander↗

Radio Frequency Telemetry System for Sensors and Actuators

The present invention discloses and teaches apparatus for combining Radio Frequency (RF) technology with novel micro-inductor antennas and signal processing circuits for RF telemetry of real time, measured data, from microelectromechanical system (MEMS) sensors, through electromagnetic coupling with a remote poweringheceiving device. Such technology has many applications, but is especially useful in the biomedical area.

Rainee N Simons↗

Interaction of Porosity with a Planar Solid/Liquid Interface

In this article, an investigation of the interaction between gas porosity and a planar solid/liquid (SL) interface is reported. A two-dimensional numerical model able to accurately track sharp SL interfaces during solidification of pure metals and alloys is proposed. The finite-difference method and a rectangular undeformed grid are used for computation. The SL interface is described through the points of intersection with the grid lines. Its motion is determined by the thermal and solute gradients at each particular point. Changes of the interface temperature because of capillarity or solute redistribution as well as any perturbation of the thermal and solute field produced by the presence of non-metallic inclusions can be computed. To validate the model, the dynamics of the interaction between a gas pore and a solidification front in metal alloys was observed using a state of the art X-ray transmission microscope (XTM). The experiments included observation of the distortion of the SL interface near a pore, real-time measurements of the growth rate, and the change in shape of the porosity during interaction with the SL interface in pure Al and Al-0.25 wt pct Au alloy. In addition, porosity-induced solute segregation patterns surrounding a pore were also quantified.

Catalina, Adrian V.↗

Torque Transient of Magnetically Drive Flow for Viscosity Measurement

Viscosity is a good indicator of structural changes for complex liquids, such as semiconductor melts with chain or ring structures. This paper discusses the theoretical and experimental results of the transient torque technique for non-intrusive viscosity measurement. Such a technique is essential for the high temperature viscosity measurement of high pressure and toxic semiconductor melts. In this paper, our previous work on oscillating cup technique was expanded to the transient process of a magnetically driven melt flow in a damped oscillation system. Based on the analytical solution for the fluid flow and cup oscillation, a semi-empirical model was established to extract the fluid viscosity. The analytical and experimental results indicated that such a technique has the advantage of short measurement time and straight forward data analysis procedures

Ban, Heng↗

Novel diode laser-based sensors for gas sensing applications

The development of compact spectroscopic gas sensors and their applications to environmental sensing will be described. These sensors employ mid-infrared difference-frequency generation (DFG) in periodically poled lithium niobate (PPLN) crystals pumped by two single-frequency solid state lasers such as diode lasers, diode-pumped solid state, and fiber lasers. Ultrasensitive, highly selective, and real-time measurements of several important atmospheric trace gases, including carbon monoxide, nitrous oxide, carbon dioxide, formaldehyde [correction of formaldehye], and methane, have been demonstrated.

NASA Discipline Life Sciences Technologies↗