Pulse Strengthened and Laser Edge Sealed Vacuum Insulation Glazing

A scalable, low-cost processing strategy for glass strengthening and sealing is proposed to improve the thermal performance of insulating glass units and develop innovative window technologies. In this project, a combination of large area photonic processing, additive manufacturing, and laser encapsulation techniques is reported to realize a vacuum glazing technology to meet the cost, performance, reliability, and throughput demands. A modeling framework for evaluating the mechanical and thermal response was established to verify the structural deformation and thermal conductance. Micro-size glass frits in printing ink and a continuous-wave laser curing were employed to allow the formation of a hermetic bonding layer and led to improvement of glass edge sealing. Various sealing parameters, including laser traveling speed, spot diameter, and laser power were optimized. The water seepage and mechanical strength of the resulting glass-to-glass bonding were examined as well. These results showcase the development of a practical vacuum insulating glazing with several unique features through a combination of photonic processing, laser encapsulation, and additive manufacturing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Evaluation of CCS and NACS Reference Devices and Adapters

A review of NLR's work in charging system reliability for charging inlets, connectors, and adapters. The review includes a detailed discussion on (a) the development of a reference device for the thermal performance of charging connectors and adapters, (b) evaluation of charging adapters and their thermal warning and shutdown response, (c) implications of side-load from real-world implementations, and (d) strengthening the conformance evaluation for end caps based on field data.

33 ADVANCED PROPULSION SYSTEMS↗

A fixed tilt solar collector employing reversible vee-through reflectors and evaluated tube receivers for solar heating and cooling systems

The Vee-Trough/Evacuated Tube Collector (VTETC) was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrators, and the quasi-steady state thermal performance of the evacuated tube receivers. Tests were run to verify the mathematical analyses. Back-silvered glass mirror, Alzak, Aluminized Teflon, and Kinglux (electropolished aluminum reflectors) were tested. Additional tests were run at temperatures ranging from 80 to 190 C (176-374 F). For the glass mirror reflectors, peak efficiencies, based on aperture area and operating temperatures of 125 C (257 F), were over 40%. Efficiencies of about 40% were observed at temperatures of 150 C (302 F) and 30% at 175 C (347 F). Test data for several days, predicted daily useful heats, and efficiency values are presented for a full year. These theoretical values were then compared with actual data points for the same temperature range.

Selcuk, M. K.↗

PERFORMANCE ANALYSIS OF MECHANICAL DRAFT COOLING TOWER

Industrial processes use mechanical draft cooling towers (MDCT's) to dissipate waste heat by transferring heat from water to air via evaporative cooling, which causes air humidification. The Savannah River Site (SRS) has cross-flow and counter-current MDCT's consisting of four independent compartments called cells. Each cell has its own fan to help maximize heat transfer between ambient air and circulated water. The primary objective of the work is to simulate the cooling tower performance for the counter-current cooling tower and to conduct a parametric study under different fan speeds and ambient air conditions. The Savannah River National Laboratory (SRNL) developed a computational fluid dynamics (CFD) model and performed the benchmarking analysis against the integral measurement results to accomplish the objective. The model uses three-dimensional steady-state momentum, continuity equations, air-vapor species balance equation, and two-equation turbulence as the basic governing equations. It was assumed that vapor phase is always transported by the continuous air phase with no slip velocity. In this case, water droplet component was considered as discrete phase for the interfacial heat and mass transfer via Lagrangian approach. Thus, the air-vapor mixture model with discrete water droplet phase is used for the analysis. A series of parametric calculations was performed to investigate the impact of wind speeds and ambient conditions on the thermal performance of the cooling tower when fans were operating and when they were turned off. The model was also benchmarked against the literature data and the SRS integral test results for key parameters such as air temperature and humidity at the tower exit and water temperature for given ambient conditions. Detailed results will be published here.

42 ENGINEERING↗

Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management

Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272

thermodynamics↗

Nonlinear least squares - An aid to thermal property determination

Nonlinear least squares techniques can be used to determine effective thermal conductivity values from experimental data. Comparisons between measured and predicted conductivity values indicate that the analytically determined values can be used with confidence in performing thermal protection system analyses. A study was performed to compare the relative efficiencies of different minimizing techniques; techniques; the method of Peckham was the most efficient.

Curry, D. M.↗

Nonlinear least squares - An aid to thermal property determination.

Nonlinear least squares techniques can be used to determine effective thermal conductivity values from experimental data. Comparisons between measured and predicted conductivity values indicate that the analytically determined values can be used with confidence in performing thermal protection system analyses. A study was performed to compare the relative efficiencies of different minimizing techniques; the method of Peckham was the most efficient.

Curry, D. M.↗

Design and performance of a Cryogenic Heat Pipe Experiment (CRYOHP)

The Cryogenic Heat Pipe Experiment which is designed to demonstrate the thermal performance of two different axially grooved oxygen heat pipes in microgravity is discussed. The CRYOHP is manifested for flight aboard STS-53. The first heat pipe design is based on an extrapolated 0-g transport capability of about 20 W-m with oxygen in the range of 80-100 K. The second heat pipe design permits 0-g 'dry-out' in the CRYOHP and offers improved ground testability for 1-g correlation.

Beam, Jerry↗

Transient Heater Analysis for Orion Thermal Vacuum Testing

The Space Environments Complex (SEC) at NASA's Plum Brook Station is currently being prepared to perform thermal vacuum testing of the Orion spacecraft. This thermal vacuum, or T-VAC test will be run for a period of 60 days, which will be the longest such test ever conducted at SEC. The Orion Crew Module (CM) and Service Module (SM) will undergo T-VAC testing in SEC's Space Simulation Vacuum Chamber to ensure the functionality of these systems in a high vacuum environment at extremely cold temperatures. The T-VAC test setup in SEC was modeled and simulated in Thermal Desktop. The initial results from thermal analysis showed areas on the chamber floor to reach very low temperatures, which were below the minimum operating range of certain hardware located on or near the chamber floor. These hardware including elastomeric seals on the GN2 piping, bearing pads and O-rings are essential to both test and the operation of the SEC facility, and must be kept well above -20°F throughout the duration of the T-VAC test. Thus, further analysis was conducted to include the placement of patch heaters on the chamber floor in an effort to increase the temperature near colder areas on the floor. The results and findings from this analysis showed that using these heaters will result in a favorable temperature distribution on the chamber floor. This paper will discuss the methods used in the analysis, and the results obtained to determine the optimal configuration of these heaters on the chamber floor.

Wilhite, Jarred↗

Transient Heater Analysis for Orion Thermal Vacuum Testing

The Space Environments Complex (SEC) at NASA’s Plum Brook Station is currently being prepared to perform thermal vacuum testing of the Orion spacecraft. This thermal vacuum, or T-VAC test will be run for a period of 60 days, which will be the longest such test ever conducted at SEC. The Orion Crew Module (CM) and Service Module (SM) will undergo T-VAC testing in SEC’s Space Simulation Vacuum Chamber to ensure the functionality of these systems in a high vacuum environment at extremely cold temperatures. The T-VAC test setup in SEC was modeled and simulated in Thermal Desktop. The initial results from thermal analysis showed areas on the chamber floor to reach very low temperatures, which were below the minimum operating range of certain hardware located on or near the chamber floor. These hardware including elastomeric seals on the GN2 piping, bearing pads and O-rings are essential to both test and the operation of the SEC facility, and must be kept well above -20°F throughout the duration of the T-VAC test. Thus, further analysis was conducted to include the placement of patch heaters on the chamber floor in an effort to increase the temperature near colder areas on the floor. The results and findings from this analysis showed that using these heaters will result in a favorable temperature distribution on the chamber floor. This paper will discuss the methods used in the analysis, and the results obtained to determine the optimal configuration of these heaters on the chamber floor.

Wilhite, Jarred↗

Thermal management for a motor feeder

Provided are embodiments for a feeder cooling tube, a system and method for performing thermal management. Embodiments include a feeder cooling tube having an inner tube arranged to define a path to flow a fluid through a length of the inner tube, wherein the fluid is provided to remove heat, and an outer tube arranged to enclose the inner tube which defines an area. Embodiments also include one or more feeder cables arranged between the inner tube and the outer tube, and a plurality of cooling struts, wherein each cooling strut of the plurality of cooling struts extends from a surface of the inner tube to a surface of the outer tube.

Pal, Debabrata↗

Mechanical, Fire Retardant, Water Absorption and Soil Biodegradation Properties of Poly(3-hydroxy-butyrate-co-3-valerate) Nanofilms

Biopolymers provide potential substitution to synthetic polymers derived from scarce petroleum materials which are not environmental friendly and biodegradable. However, there exists challenging or unanswered questions for biopolymers to be used in biomedical, film packaging, automobile, construction and commercial industries such as their mechanical performance, thermal and fire retardancy, and durability when exposed to water. In this study, we investigated one such potential biopolymer, poly(3-hydroxy-butyrate-co-3-valerate) (PHBV) for the aforementioned properties. At first, 0–15 wt% halloysite nanotubes (HNTs) was dispersed in PHBV polymer using ultrasonication process in presence of chloroform solvent. The solvent was then evaporated and PHBV/HNTs films were prepared by solution casting method. PHBV films without HNTs (neat) were also prepared for baseline comparison. Thermogravimetric analysis (TGA) and tensile tests were then performed to study the thermal and mechanical properties of these films. The horizontal burning test (HBT) was also carried out to investigate the fire retardancy behavior. Finally, the water absorption and soil biodegradability behavior of these composites were investigated by submerging the films in water and Alabama soil conditions. PHBV films with 3 wt% loading showed optimum enhancement in thermal stability and tensile properties. In contrast, films with 10–15 wt% HNTs loading showed superior fire-retardancy, better water resistance and faster soil degradation over neat counterpart.

54 ENVIRONMENTAL SCIENCES↗

Thermal control surfaces experiment (SOO69) flight systems performance

The thermal control surfaces experiment (TCSE) was the most complex hardware system aboard the Long Duration Exposure Facility (LDEF). The TCSE system consists of a scanning spectroreflectometer that measured test samples mounted on a rotatable carousel assembly. A microprocessor based data system controlled all aspects of TCSE system operation. Power was provided by four primary batteries. Flight measurement and housekeeping data were stored on a tape recorder for postflight analysis. The TCSE is a microcosm of complex electro-optical payloads being developed by NASA, DoD, and the aerospace community. The TCSE provides valuable data on the performance of these systems in space. The TCSE flight system and its excellent performance on the LDEF mission are described. A few operational anomalies were encountered and are discussed. Initial post-flight tests show that the TCSE system remains functional although some degradation in the optical measurements were observed. The results of these tests are also presented.

Wilkes, Donald R.↗

Improved Manufacturability and Throughput of Ultra- Transparent, Super-Insulating Aerogels

AeroShield Materials produces a novel silica aerogel material with exemplary thermal performance and unprecedented optical clarity, offering the potential for super-insulating fenestration and insulated glass to reduce thermal losses in the built environment by billions of dollars every year. One of the most significant challenges facing AeroShield today is the total amount of time that is required to produce large monolithic aerogel samples. This overall process can require as much as 144 hours total, which can significantly hinder scale-up to an economically viable product. The purpose of this Phase 1 research was to continue development of our novel aerogel manufacturing process to reduce material processing time by up to 10x, greatly improving product throughput and reducing cost. AeroShield’s manufacturing process can be divided into 4 major stages, each with their own distinct set of parameters and time requirements. Under this Phase 1 award, AeroShield was able to identify and optimize a number of these parameters, including molding materials, solvent rinse conditions, critical point drying time, and annealing conditions. AeroShield also performed thorough analyses on how these optimized parameters affected important final characteristics of the gels, including optical clarity, thermal conductivity, and dimensional stability. This campaign culminated in the production of laboratory scale aerogel samples using significantly lower process times of both 36 and 18 total hours, which represent Phase 1 Target and Stretch goals. In order to achieve widespread market adoption, monolithic sheets of the aerogel material must be made to industry-standard sizes (8’ x 12’) at a cost that provides 5-7 year or less breakeven energy savings for consumers (<$2 sq/ft). The work performed under this Phase 1 award shows that time and materials required to make aerogel samples, which make up a significant portion of their overall cost, can be greatly reduced without sacrificing quality. AeroShield plans to use these optimized processes to produce larger, product-relevant sized aerogels in order to achieve target final material costs.

Wilke, Kyle↗

Performance analysis of a latent heat storage system with phase change material for new designed solar collectors in greenhouse heating

The continuous increase in the level of greenhouse gas emissions and the rise in fuel prices are the main driving forces behind the efforts for more effectively utilize various sources of renewable energy. In many parts of the world, direct solar radiation is considered to be one of the most prospective sources of energy. In this study, the thermal performance of a phase change thermal storage unit is analyzed and discussed. The storage unit is a component of ten pieced solar air collectors heating system being developed for space heating of a greenhouse and charging of PCM. CaCl{sub 2}6H{sub 2}O was used as PCM in thermal energy storage with a melting temperature of 29 C. Hot air delivered by ten pieced solar air collector is passed through the PCM to charge the storage unit. The stored heat is utilized to heat ambient air before being admitted to a greenhouse. This study is based on experimental results of the PCM employed to analyze the transient thermal behavior of the storage unit during the charge and discharge periods. The proposed size of collectors integrated PCM provided about 18-23% of total daily thermal energy requirements of the greenhouse for 3-4 h, in comparison with the conventional heating device. (author)

14 SOLAR ENERGY↗

Distribution of air-water mixtures in parallel vertical channels as an effect of the header geometry

Uneven phase distribution in heat exchangers is a cause of severe reductions in thermal performances of refrigeration equipment. To date, no general design rules are available to avoid phase separation in manifolds with several outlet channels, and even predicting the phase and mass distribution in parallel channels is a demanding task. In the present paper, measurements of two-phase air-water distributions are reported with reference to a horizontal header supplying 16 vertical upward channels. The effects of the operating conditions, the header geometry and the inlet port nozzle were investigated in the ranges of liquid and gas superficial velocities of 0.2-1.2 and 1.5-16.5 m/s, respectively. Among the fitting devices used, the insertion of a co-axial, multi-hole distributor inside the header confirmed the possibility of greatly improving the liquid and gas flow distribution by the proper selection of position, diameter and number of the flow openings between the supplying distributor and the system of parallel channels connected to the header. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SURFACE MODIFICATION OF ZIRCALOY-4 SUBSTRATES WITH NICKEL ZIRCONIUM INTERMETALLICS

Surfaces of Zircaloy-4 (Zr-4) substrates were modified with nickel-zirconium (NiZr) intermetallics to tailor oxidation performance for specialized applications. Surface modification was achieved by electroplating Zr-4 substrates with nickel (Ni) and then performing thermal treatments to fully react the Ni plating with the substrates, which resulted in a coating of NiZr intermetallics on the substrate surfaces. Both plating thickness and thermal treatment were evaluated to determine the effects of these fabrication parameters on oxidation performance and to identify an optimal surface modification process. Isothermal oxidation tests were performed on surface-modified materials at 290°, 330°, and 370°C under a constant partial pressure of oxidant (i.e., 1 kPa D2O in dry Ar at 101 kPa) for 64 days. Test results revealed an enhanced, transient oxidation rate that decreased asymptotically toward the rate of the Zr-4 substrate. Oxidation kinetics were analyzed from isothermal weight gain data, which were correlated with microstructure, hydrogen pickup, strength, and hardness.

Intermetallic↗

Helical Fins for Concentrated Solar Receivers: Design Optimization and Entropy Analysis

Concentrated solar power (CSP) with thermal energy storage (TES) has the potential to achieve grid parity. This can be realized by operating CSP systems at temperatures above 700 °C with high-efficiency sCO 2 power cycles. However, operating CSP systems at such temperatures poses several challenges, among which the design of solar receivers to accommodate increased thermal loads is critical. To this end, this work explores and optimizes various swirl-inducing internal fin designs for solar receiver tubes. These fin designs not only improve the thermal performance of receiver tubes but also levelize temperature unevenness caused by non-uniform thermal loading. In this work, the geometric parameters of the fin designs are optimized to maximize the Nusselt number with a constraint on the friction factor. This optimization, however, is computationally intensive, requiring hundreds of simulation calls to computational fluid dynamics (CFD) models. Here, to circumvent this problem, surrogate models are used to approximate the simulation outputs needed during the optimization. In addition, this study also examines the fin designs from an entropy generation perspective. To this end, the entropy contributions from thermal and viscous effects are quantitatively compared while varying the operational Reynolds number.

14 SOLAR ENERGY↗