Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Modis TEB Electronic Crosstalk Correction Update and Impact on L1B Product Uncertainty

The MODIS instruments on board the Terra and Aqua satellites have been in operation for over 22 and 20 years, respectively. The instruments’ calibration accuracy has been maintained, even with instrument degradation. Electronic crosstalk in the thermal emissive bands (TEB) is a known issue with an increasing impact on the calibration and product. The Terra MODIS photovoltaic (PV) longwave infrared (LWIR) bands crosstalk corrections have been applied in Collection 6.1 (C6.1). However, the electronic crosstalk contamination for some detectors in the mid-wave infrared(MWIR) bands and the Aqua PVLWIR bands affect the Level-1B(L1B) product’s measurement accuracy and image quality. In Collection 7 (C7), crosstalk corrections for select detectors in the Terra and Aqua MWIR and Aqua PV LWIR bands are applied. The entire mission crosstalk coefficients for the select detectors and bands are derived from scheduled lunar observations and populated in the form of look-up tables (LUTs). The Aqua PV-LWIR bands exhibit similar downward crosstalk trends as the Terra PV-LWIR bands, especially in recent years. The crosstalk coefficients and their trends provide a guideline for the correction application. Earth measurement analyses before and after the correction provide contamination and correction assessments. It has been shown that the product quality is enhanced with the crosstalk correction applied in C7. For C7, the crosstalk coefficient uncertainty is derived from the fit residuals between the measured values and a linear fit over a three-year sliding window. The uncertainty propagation is modeled and applied in the total uncertainty calculation intheL1B product. The TEB electronic cross talk LUT shave been processed over the entire Terra and Aqua MODIS missions. This paper presents the C7 crosstalk correction, as well as its assessment and uncertainty propagation algorithm to the TEB uncertainty.

Tiejun Chang↗

AERACEPT (AErosol Rapid Analysis Combined Entry Probe/sonde Technology) for the Nephele Venus Cloud Mission Concept

Nephele is a small atmospheric probe mission concept to determine whether the Venus clouds contain organic matter. Nephele complements larger missions that seek to conduct Venus atmospheric analyses, such as DAVINCI, Venera-D, and the Morning Star missions, by directly sampling and analyzing cloud and haze particles. AERACEPT is an aerosol sampling technology designed to minimize the mass, volume, and complexity required for in situ planetary atmosphere characterization. A single aeroshell functions as a combined entry vehicle, descent probe, and instrumented sonde, combining recent advances in thermal protection materials with heritage technology from planetary and airborne science. The velocity of descent drives aerosol through inlets embedded in the aeroshell’s thermal protection material; inertial separation isolates the particles from the gas stream; and the particle capture surface doubles as the analysis substrate. This method can work without heat shield separation, descent control, or active sample handling; these advantages trade against a smaller sample volume, higher risk of sample heating, and shorter time for analysis and data return. AERACEPT further benefits from modeling of the internal and external flow to understand the particle capture efficiency and bias for size and concentration distributions. AERACEPT is well suited for a Venus mission such as Nephele, where a passive descent trajectory is both subsonic over the altitudes of interest and provides sufficient velocity and pressure differential for the particle sizes of interest. A thermal and flow toolchain developed in-house (Traj→ DPLR→ PATO→ openFOAM) was used to model an 80-cm aeroshell with science operations 63–39 km. These models indicate that AERACEPT will provide ~24 µL accumulated sample of particles ≥ 0.2 µm, substantially above the 2 µL threshold requirement. The worst-case particle heating will be ~14 K above ambient, for the smallest particles at the lowest altitude; most particles will experience ≤ 1 K rise, at which almost all analytes of interest will be unaffected. Plasma jet testing of a small-scale aeroshell-material inlet was recently conducted to validate the thermal model parameters; wind tunnel testing to validate the flow model parameters is underway.

AERACEPT↗

CCN data from TAMU TRACER campaign in the Houston TX region from July to September 2022

During TRACER, the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V) was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and a Davis Rotating Uniform size-cut Monitor (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Onboard the ROAM-V, aerosol samples are drawn through a shared isokinetic inlet at a flow rate ranging from 3.5 to 7.0 LPM. A portion of this flow is directed through a cyclone impactor (Brechtel, Inc. Model SCC 0.732) and 0.5 LPM is directed to the CCN. To calculate particle losses, we used a two-step method. First, the measured SMPS size distributions were used to calculate particle loss through the inlet during sampling. Second, the corrected SMPS data was used to calculate the average of the total losses per scan down the CCN line. Then, the correction was applied to the CCN data. This calculation was done separately for each deployment location due to changes in the measured size distributions between locations. Particle loss from diffusion (based on Kesten, 1991 and Gormley, 1949), inertial impaction in 90-degree bends (based on Aerosol Measurement, 2011 and Crane, 1977), and cyclone impactor efficiency (based on Dirgo, 1985) were included in the loss calculation. When the SMPS was not sampling at a location (in the case of an instrument malfunction or operator error), the reported CPC data was corrected with an average of the total losses for the entire campaign at the specified deployment location (e.g., if we needed to correct Galveston data, then the average of all calculated losses at Galveston was taken). These flatline corrections were used for all data on 22/07/13, 22/07/20, 22/07/22, and the data from Galveston on 22/08/09. The supersaturation uncertainty is estimated conservatively at +/- 0.03%, where variation in the inlet temperature, pressure, and calibration technique prevents a more accurate measurement. Confidence in the reported supersaturation measurements is based on a pre-campaign calibration (following the methods from our previous work and Deng, 2014 based on Rose, 2008) in addition to inter-comparisons with the DOE for two days (22/08/18 and 22/09/01) where TAMU was co-located with AMF1. The inter-comparisons show good agreement between our instrument and the DOEs instrument on both days at all supersaturations. After the last inter-comparison on 22/09/01, there was no indication of a malfunction by our instrument through the rest of the campaign. Unfortunately, the instrument was dropped during demobilization. A post-campaign calibration was conducted, which showed a substantial departure from the pre-campaign calibration. The drop may have damaged the instrument’s ability to produce the desired supersaturations. Therefore, we do consider the data after 22/09/01 to be correct, but it should be used with caution. The CCN counter sampled for 3 minutes at each supersaturation setpoint (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%). At the end of a cycle, the instrument was set to 0.01% supersaturation for 5 minutes. The data is comprised of the last 60 seconds of each supersaturation set point (0.2, 0.4, 0.6, 0.8, 1.0, and 1.2%) to ensure the instrument stabilized and was able to reach thermal equilibrium. We removed the data during the periods where there were operational difficulties, setup, or maintenance. This data was collected for ARM Field Campaign AFC07055 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Rose et. al. Calibration and Measurement Uncertainties of a Continuous-Flow Cloud Condensation Nuclei Counter (DMT-CCNC): CCN Activation of Ammonium Sulfate and Sodium Chloride Aerosol Particles in Theory and Experiment. Atmos. Chem. Phys., 8, 1153-1179, 2008. Deng et. al. Using Raman Microspectroscopy to Determine Chemical Composition and Mixing State of Airborne Marine Aerosols over the Pacific Ocean. Aerosol Science and Technology, Vol 48, Issue 2, 2014. Kesten et. al. Calibration of a TSI Model 3025 Ultrafine Condensation Particle Counter. Aerosol Science and Technology, 15:2, 107-111, 1991. Gormley et. al. Diffusion from a Stream Flowing through a Cylindrical Tube. Proceedings of the Royal Irish Academy, Vol 52, 163-169, 1948. Aerosol Measurement: Principles, Techniques, and Applications, Third Edition. John Wiley & Sons, Inc, 2011. Crane et. al. Inertial Deposition of Particles in a Bent Pipe. Journal of Aerosol Science, Vol 8, 161-170, 1977. Dirgo et. al. Cyclone Collection Efficiency: Comparison of Experimental Results with Theoretical Predictions. Aerosol Science and Technology, 4:4, 401-415, 1985.

54 ENVIRONMENTAL SCIENCES↗

Compact, Deep-Penetrating Geothermal Heat Flow Instrumentation for Lunar Landers

Geothermal heat flow is obtained as a product of the two separate measurements of geothermal gradient in, and thermal conductivity of, the vertical soi/rock/regolith interval penetrated by the instrument. Heat flow measurements are a high priority for the geophysical network missions to the Moon recommended by the latest Decadal Survey [I] and previously the International Lunar Network [2]. The two lunar-landing missions planned later this decade by JAXA [3] and ESA [4] also consider geothermal measurements a priority.

Nagihara, S.↗

The Geostationary Fourier Transform Spectrometer

The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for an earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. The GeoFTS instrument is a half meter cube size instrument designed to operate in geostationary orbit as a secondary "hosted" payload on a commercial geostationary satellite mission. The advantage of GEO is the ability to continuously stare at a region of the earth, enabling frequent sampling to capture the diurnal variability of biogenic fluxes and anthropogenic emissions from city to continental scales. The science goal is to obtain a process-based understanding of the carbon cycle from simultaneous high spatial resolution measurements of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) many times per day in the near infrared spectral region to capture their spatial and temporal variations on diurnal, synoptic, seasonal and interannual time scales. The GeoFTS instrument is based on a Michelson interferometer design with a number of advanced features incorporated. Two of the most important advanced features are the focal plane arrays and the optical path difference mechanism. A breadboard GeoFTS instrument has demonstrated functionality for simultaneous measurements in the visible and IR in the laboratory and subsequently in the field at the California Laboratory for Atmospheric Remote Sensing (CLARS) observatory on Mt. Wilson overlooking the Los Angeles basin. A GeoFTS engineering model instrument is being developed which will make simultaneous visible and IR measurements under space flight like environmental conditions (thermal-vacuum at 180 K). This will demonstrate critical instrument capabilities such as optical alignment stability, interferometer modulation efficiency, and high throughput FPA signal processing. This will reduce flight instrument development risk and show that the GeoFTS design is mature and flight ready.

Carbon exchanges↗

Mechanical Design and Operation of a Novel Lunar Environment Structural Test Rig (LESTR)

The Lunar Environment Structural Test Rig (LESTR) was developed to address a critical gap in mechanical property data for metal alloy wire materials under lunar-relevant conditions down to 40 K. Conventional aerospace material databases provide thermophysical properties for bulk metals over a wide temperature range, but validated mechanical and physical property data below 77 K, particularly for small-diameter wires, remain limited and are generally the exception rather than the rule. These conditions are essential for Artemis mission hardware such as shape memory alloy (SMA) rover tires. LESTR’s design requirements were to combine a high-stiffness electrodynamic load frame with closed- cycle cryogenic cooling, high-vacuum capability (10–6 torr), and noncontact optical strain measurement to enable tensile, four-point bend, and fatigue testing of wires or other materials and geometries at temperatures from 40 to 125 K. These considerable requirements were merged with the need to lower the barrier of testing for the end user as measured in terms of cost-per-test cycle, safety improvement, and reduction in upkeep costs associated with state-of-the-art solutions associated with cryomechanical material characterization. The system incorporates modular gripping and alignment fixtures; precision thermal management using cryocoolers and embedded heaters; and integrated instrumentation for displacement, load, temperature, and vacuum control. Calibration procedures establish correlations between tooling and specimen temperature, ensuring accurate thermal conditions across the design envelope unbound by cryofluid conditions in heritage immersion-based test systems. Initial validation tests using Inconel (Special Metals Corp.) wire demonstrated accurate ultimate strength and post-yield behavior. The load frame operation was also verified under representative service conditions, including thermal cycling and prolonged fatigue loading. By generating mechanical property data at ultralow temperatures, LESTR fills a critical gap in existing materials databases and provides a scalable platform for iterative alloy development and durability assessment for planetary hardware. This capability supports NASA’s long-term objectives for surface exploration by enabling design confidence for components operating in extreme cryogenic environments.

LESTR↗

Orbiter thermal protection system

The major material and design challenges associated with the orbiter thermal protection system (TPS), the various TPS materials that are used, the different design approaches associated with each of the materials, and the performance during the flight test program are described. The first five flights of the Orbiter Columbia and the initial flight of the Orbiter Challenger provided the data necessary to verify the TPS thermal performance, structural integrity, and reusability. The flight performance characteristics of each TPS material are discussed, based on postflight inspections and postflight interpretation of the flight instrumentation data. Flights to date indicate that the thermal and structural design requirements for the orbiter TPS are met and that the overall performance is outstanding.

Dotts, R. L.↗

A thermal canister experiment for the Space Shuttle

An experiment will be described which, if successful, will demonstrate the feasibility of using a heat pipe thermal canister to control the temperature of a wide variety of instruments operating in the bay of the NASA Space Shuttle. The experiment will be launched in December 1979 as part of the fourth orbital flight test of the Shuttle. Predictions indicate that the canister can provide an environment controlled to + or - 1 C over the range of 0 C to 30 C for conductively and radiatively coupled instruments with internal power dissipations of approximately 100 to 400 watts. This is the most ambitious thermal control program yet attempted which uses heat pipes as the primary control element. The outcome of this experiment will have far reaching implications for instruments which are operated in the Shuttle bay.

Mcintosh, R.↗

Cryogenic Thermal Distortion Model Validation for the JWST ISIM Structure

The James Webb Space Telescope (JWST) is a large, infrared-optimized space telescope consisting of an Optical telescope element (OTE), Integrated science instrument module (ISIM), a Spacecraft, and a Sunshield. The Integrated Science Instrument Module (ISIM) consists of the JWST science instruments (NIRCam, MIRI, NIRSpec), a fine guidance sensor (FGS), the ISIM Structure, and thermal and electrical subsystems. JWST's instruments are designed to work primarily in the infrared range of the electromagnetic spectrum, and the instruments and telescope operate at cryogenic temperatures (approximately 35 K for the instruments).

Johnston, John↗

Advanced Thermal Simulator Testing: Thermal Analysis and Test Results

Work at the NASA Marshall Space Flight Center seeks to develop high fidelity, electrically heated thermal simulators that represent fuel elements in a nuclear reactor design to support non-nuclear testing applicable to the development of a space nuclear power or propulsion system. Comparison between the fuel pins and thermal simulators is made at the outer fuel clad surface, which corresponds to the outer sheath surface in the thermal simulator. The thermal simulators that are currently being tested correspond to a SNAP derivative reactor design that could be applied for Lunar surface power. These simulators are designed to meet the geometric and power requirements of a proposed surface power reactor design, accommodate testing of various axial power profiles, and incorporate imbedded instrumentation. This paper reports the results of thermal simulator analysis and testing in a bare element configuration, which does not incorporate active heat removal, and testing in a water-cooled calorimeter designed to mimic the heat removal that would be experienced in a reactor core.

Bragg-Sitton, Shannon M.↗

Thermal conductance of two interface materials and their applications in space systems

The temperature control of spacecraft and instrument systems and subsystems requires heat transfer interface materials that possess good thermal and structural characteristics, among other properties, to respond to the vacuum environment of space. These materials must be easy to apply to, and remove from, the surfaces where they are applied, and must be able to withstand power dissipation extremes, and be used for different clamping configurations and pressures. Silicone based greases, used in the past, tend to migrate and to contaminate nearby surfaces. Bare metal to metal contact offers low thermal conductance and difficulties in estimating the actual heat transfer. Several polymeric materials containing different thermal conductive compounds and structural reinforcements were prepared to overcome grease and metal problems. Two polymeric materials were evaluated: Cho-Therm 1671 elastomer; and the CV-2946, a conductive RTV silicone. Tests were done to learn more about these products. Results indicate that the tightly bolted, torqued fixtures did not buckle or distort, and provided optimum thermal conductance. Fixtures simulating actual spacecraft configuration suffered bowing and separating.

Scialdone, J. J.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

Gaier, James R.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10-8 Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust stimulant processing capabilities: heating and cooling while stirring in order to degas and remove absorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions, and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples

Gaier, James R.↗

Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar

A simulation chamber has been developed to test the performance of thermal control surfaces under dusty lunar conditions. The lunar dust adhesion bell jar (LDAB) is a diffusion pumped vacuum chamber (10(exp -8) Torr) built to test material samples less than about 7 cm in diameter. The LDAB has the following lunar dust simulant processing capabilities: heating and cooling while stirring in order to degas and remove adsorbed water; RF air-plasma for activating the dust and for organic contaminant removal; RF H/He-plasma to simulate solar wind; dust sieving system for controlling particle sizes; and a controlled means of introducing the activated dust to the samples under study. The LDAB is also fitted with an in situ Xe arc lamp solar simulator, and a cold box that can reach 30 K. Samples of thermal control surfaces (2.5 cm diameter) are introduced into the chamber for calorimetric evaluation using thermocouple instrumentation. The object of this paper is to present a thermal model of the samples under test conditions and to outline the procedure to extract the absorptance, emittance, and thermal efficiency from the pristine and sub-monolayer dust covered samples.

Gaier, James R.↗

Hawai’i Climate: Utilizing NASA Earth Observations to Assess Thermal Stress Impacts on Coastal Hawaiian Fishponds

Hawaiian fishponds (loko i’a), ancient aquaculture systems created over 1500 years ago, historically served to harvest prized native fish species. Colonization-induced changes in land management have reduced active loko i’a from over 500 to ~20, destabilizing nearshore ecosystems and diminishing native Hawaiian cultural traditions. In recent decades, efforts to restore loko i’a have intensified as part of a broader emphasis on preserving Hawaiian cultural identity. Anthropogenic-induced climate change threatens these systems, particularly through the increase in frequency and magnitude of marine heatwaves. Though largely unexplored, these events are effectively studied utilizing remote sensing via Earth observations. Leveraging this technique enables autonomous extraction of water quality parameters to inform fishpond management. This study examined seven loko i’a across the main Hawaiian Islands (Hawai’i Island, Moloka’i, Maui, O’ahu, Kaua’i). Sea surface temperature and normalized difference chlorophyll index measurements were derived in fishponds utilizing Landsat 8 Thermal Infrared Sensor Thermal Infrared Sensor and Sentinel-2 MultiSpectral Instrument between 2013 to 2023, while regional patterns in temperature and chlorophyll-a were observed via Aqua’s Moderate Resolution Imaging Spectroradiometer (2002-2021). Employing these sensors, we focused analysis around the 2015 and 2019 marine heatwaves in the Pacific. We observed a heat stress gradient across the archipelago, creating thermally sheltered and unsheltered fishponds, yet identified no notable localized relationships between temperature and chlorophyll-a. Additionally, we applied pre-determined thermal maxima for culturally significant fish species (Striped Mullet: Mugil cephalus; Milkfish: Chanos Chanos) to assess historical habitat suitability within fishponds. While the direct impacts of marine heatwaves on loko i’a ecology are unknown, temperature patterns observed in this study are cause for concern.

Raz Wachtel↗

Charge collection in h -BN neutron detectors at elevated temperatures

Many of the neutron detector applications are in the environments with harsh conditions such as high temperatures. We report here the measurements of charge collection parameters of hexagonal boron nitride (h-BN) detectors at elevated temperatures, including the electron mobility-lifetime product (μτ) and surface recombination field (s/μ). It was found that μτ is increased, while s/μ is decreased as temperature increases. The temperature dependence of the surface recombination field (s/μ) revealed that electrons trapped in the surface states tend to thermally activate to the bulk region at higher temperatures with an activation energy of about 0.22 eV, leading to a reduction in the density of the charged surface states at elevated temperatures. Consequently, the charge collection efficiency is enhanced at elevated temperatures due to a reduced surface recombination field and increased electron mobility-lifetime product. The results suggested that h-BN neutron detectors are favorable for high temperature operation.

47 OTHER INSTRUMENTATION↗