Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Bioverse: A Simulation Framework to Assess the Statistical Power of Future Biosignature Surveys

Next-generation space observatories will conduct the first systematic surveys of terrestrial exoplanet atmospheres and search for evidence of life beyond Earth. While in-depth observations of the nearest habitable worlds may yield enticing results, there are fundamental questions about planetary habitability and evolution that can only be answered through population-level studies of dozens to hundreds of terrestrial planets. To determine the requirements for next-generation observatories to address these questions, we have developed Bioverse. Bioverse combines existing knowledge of exoplanet statistics with a survey simulation and hypothesis testing framework to determine whether proposed space-based direct imaging and transit-spectroscopy surveys will be capable of detecting various hypothetical statistical relationships between the properties of terrestrial exoplanets. Following a description of the code, we apply Bioverse to determine whether an ambitious direct imaging or transit survey would be able to determine the extent of the circumstellar habitable zone and study the evolution of Earth-like planets. Given recent evidence that Earth-sized habitable zone planets are likely much rarer than previously believed, we find that space missions with large search volumes will be necessary to study the population of terrestrial and habitable worlds. Moving forward, Bioverse provides a methodology for performing trade studies of future observatory concepts to maximize their ability to address population-level questions, including and beyond the specific examples explored here.

60 APPLIED LIFE SCIENCES↗

Threshold magnitudes for a multichannel correlation detector in background seismicity

Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannel waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.

54 ENVIRONMENTAL SCIENCES↗

Practical applications of the sigma factor alarm method within alpha CAMs utilizing either ROI, tail-fitting, or peak-fitting algorithms

Some test must be applied to the low-level count data from alpha continuous air monitors (CAMs) to determine if the count is statistically significant (i.e., significantly above background). The test should also automatically account for different levels of background (i.e., different ambient radon progeny concentrations). In other words, the method should be as sensitive as possible, automatically desensitizing when required, yet in such a manner as to not exceed some previously-chosen acceptable false-alarm rate. The test that has been historically utilized within many alpha CAMs to accomplish these goals is the so-called sigma factor approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical aspects of the sigma factor alarm method in alpha CAMs

Some test must be applied to the low-level count data from alpha continuous air monitors (CAMs) to determine if the count is statistically significant (i.e., different from background). The test should also automatically account for different levels of background (i.e., ambient radon progeny concentrations). The method should, in other words, be as sensitive as possible, automatically desensitize when required, but in such a manner as to not exceed a previously-chosen acceptable false-alarm rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

An evaluation of the variable-resolution CESM for modeling California's climate

In this paper, the recently developed variable-resolution option within the Community Earth System Model (VR-CESM) is assessed for long-term regional climate modeling of California at 0.25° (~ 28 km) and 0.125° (~ 14 km) horizontal resolutions. The mean climatology of near-surface temperature and precipitation is analyzed and contrasted with reanalysis, gridded observational data sets, and a traditional regional climate model (RCM)—the Weather Research and Forecasting (WRF) model. Statistical metrics for model evaluation and tests for differential significance have been extensively applied. VR-CESM tended to produce a warmer summer (by about 1–3°C) and overestimated overall winter precipitation (about 25%–35%) compared to reference data sets when sea surface temperatures were prescribed. Increasing resolution from 0.25° to 0.125° did not produce a statistically significant improvement in the model results. By comparison, the analogous WRF climatology (constrained laterally and at the sea surface by ERA-Interim reanalysis) was ~1–3°C colder than the reference data sets, underestimated precipitation by ~20%–30% at 27 km resolution, and overestimated precipitation by ~ 65–85% at 9 km. Overall, VR-CESM produced comparable statistical biases to WRF in key climatological quantities. Moreover, this assessment highlights the value of variable-resolution global climate models (VRGCMs) in capturing fine-scale atmospheric processes, projecting future regional climate, and addressing the computational expense of uniform-resolution global climate models.

54 ENVIRONMENTAL SCIENCES↗

Higher Biologically Effective Dose of Radiotherapy Is Associated With Improved Outcomes for Locally Advanced Non-Small Cell Lung Carcinoma Treated With Chemoradiation: An Analysis of the Radiation Therapy Oncology Group

Purpose: Patients treated with chemoradiotherapy for locally advanced non-small-cell lung carcinoma (LA-NSCLC) were analyzed for local-regional failure (LRF) and overall survival (OS) with respect to radiotherapy dose intensity. Methods and Materials: This study combined data from seven Radiation Therapy Oncology Group (RTOG) trials in which chemoradiotherapy was used for LA-NSCLC: RTOG 88-08 (chemoradiation arm only), 90-15, 91-06, 92-04, 93-09 (nonoperative arm only), 94-10, and 98-01. The radiotherapeutic biologically effective dose (BED) received by each individual patient was calculated, as was the overall treatment time-adjusted BED (tBED) using standard formulae. Heterogeneity testing was done with chi-squared statistics, and weighted pooled hazard ratio estimates were used. Cox and Fine and Gray's proportional hazard models were used for OS and LRF, respectively, to test the associations between BED and tBED adjusted for other covariates. Results: A total of 1,356 patients were analyzed for BED (1,348 for tBED). The 2-year and 5-year OS rates were 38% and 15%, respectively. The 2-year and 5-year LRF rates were 46% and 52%, respectively. The BED (and tBED) were highly significantly associated with both OS and LRF, with or without adjustment for other covariates on multivariate analysis (p < 0.0001). A 1-Gy BED increase in radiotherapy dose intensity was statistically significantly associated with approximately 4% relative improvement in survival; this is another way of expressing the finding that the pool-adjusted hazard ratio for survival as a function of BED was 0.96. Similarly, a 1-Gy tBED increase in radiotherapy dose intensity was statistically significantly associated with approximately 3% relative improvement in local-regional control; this is another way of expressing the finding that the pool-adjusted hazard ratio as a function of tBED was 0.97. Conclusions: Higher radiotherapy dose intensity is associated with improved local-regional control and survival in the setting of chemoradiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Turbidity Meter for Use at the Defense Waste Processing Facility

Savannah River Remediation’s (SRR’s) Defense Waste Processing Facility (DWPF) Laboratory currently tests for sludge carry-over into the Recycle Collection Tank (RCT) by evaluating the iron concentration in the Slurry Mix Evaporator Condensate Tank (SMECT) and relating this iron concentration to the amount of sludge solids present. A new method was proposed for detecting the amount of sludge in the SMECT that involves the use of an Optek turbidity sensor. Waste Services Laboratory (WSL) personnel conducted testing on two of these units following a test plan developed by Waste Solidification Engineering (WSE). Both Optek units (SN64217 and SN65164) use sensor model AF16-N and signal converter model series C4000. The sensor body of each unit was modified to hold a standard DWPF 12 cc sample vial, also known as a “peanut” vial. The purpose of this testing was to evaluate the use of this model of turbidity sensor, or meter, to provide a measurement of the sludge solids present in the SMECT based upon samples from that tank. During discussions of the results from this study by WSE, WSL, and Savannah River National Laboratory (SRNL) personnel, an upper limit on the acceptable level of solids in SMECT samples was set at 0.14 weight percent (wt%). A “go/no-go” decision criterion was to be developed for the critical turbidity response, which is expressed in concentration units (CUs), for each Optek unit based upon the 0.14 wt% solids value. An acceptable or a “go” decision for the SMECT should reflect the situation that there is an identified risk (e.g. 5%) for a CU response from the Optek unit to be less than the critical CU value when the solids content of the SMECT is actually 0.14 wt% or greater, while a “no-go” determination (i.e., an Optek CU response above the critical CU value, a conservative decision relative to risk) would lead to additional evaluations of the SMECT to better quantify the possible solids content of the tank. Subsequent to the issuance of the initial version of this report but under the scope of the original request for technical assistance, WSE asked for this report to be revised to include the “go/no-go” CU value corresponding to 0.28 wt% solids. It was this request that led to the preparation of Revision 1 of the report. The results for the 0.28 wt% solids value were developed following the same approach as that utilized for the 0.14 wt% solids value. A sludge simulant was used to develop standards for testing both Optek units and to determine the viability of a “go/no-go” CU response for each of the units. Statistical methods were used by SRNL to develop the critical CU value for the “go/no-go” decision for these standards for each Optek unit. Since only one sludge simulant was available for this testing, the sensitivity of these results to other simulants and to actual sludge material is not known. However, limited testing with samples from the actual DWPF process (both SRAT product samples and SMECT samples) demonstrated that the use of the “go/no-go” criteria developed from the sludge simulant testing was conservative for these samples taken from the sludge batch, Sludge Batch 7b, being processed at the time of this testing. While both of the Optek units performed very reliably during this testing, there were statistically significant differences (although small on a practical scale) between the two units. Thus, testing should be conducted on any new unit of this Optek model to qualify it before it is used to support the DWPF operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of vision and sound to classify feller-buncher operational state

Productivity measures in logging involve simultaneous recognition and classification of event occurrence and timing, and the volume of stems being handled. In full-tree felling systems these measurements are difficult to implement in an autonomous manner because of the unfavorable working environment and the abundance of confounding extraneous events. This paper proposed a vision method that used a lowcost camera to recognize feller-buncher operational events including tree cutting and piling. It used a fine K-nearest neighbors (fKNN) algorithm as the final classifier based on both audio and video features derived from short video segments as inputs. The classifier’s calibration accuracy exceeds 94%. The trained model was tested on videos recorded under various conditions. The overall accurate rates for short segments were greater than 89%. Comparisons were made between the human- and algorithm derived event detection rates, events’ durations, and inter-event timing using continuously recorded videos taken during feller operation. Video results between the fKNN model and manual observation were similar. Statistical comparison using the Kolmogorov–Smirnov test to evaluate measured parameters’ distributions (manual versus automated event duration and inter-event timing) did not show significant differences with the lowest P-value among all Kolmogorov–Smirnov tests equal to 0.12. Here the result indicated the feasibility and potential of using the method for the automatic time study of drive-to-tree feller bunchers.

97 MATHEMATICS AND COMPUTING↗

Evaluating Optical Classification for Fermi Blazar Candidates with a Statistical Method Using Broadband Spectral Indices

We aim to test whether a blazar candidate of uncertain type (BCU) in the third Fermi catalog of active galactic nuclei (3LAC) can be potentially classified as a BL Lac object or a flat-spectrum radio quasar (FSRQ) by performing a statistical analysis of its broadband spectral properties. We find that 34% of the radio-selected BCUs (583 BCUs) are BL Lac-like and 20% are FSRQ-like, at a 90% level of confidence. Similarly, 77.3% of the X-ray-selected BCUs (176 BCUs) are evaluated as BL Lac-like and 6.8% may be FSRQ-like sources. And 88.7% of the BL Lac-like BCUs that have synchrotron peak frequencies available are high synchrotron peaked BL Lacs in the X-ray-selected BCUs. The percentages are accordingly 62% and 7.3% in the sample of 124 optically selected BCUs. The high ratio of the number of BL Lac-like sources to the number of FSRQ-like BCUs in the X-ray-selected and optically selected BCU samples is due to selection effects. Examining the consistency between our evaluation and spectroscopic identification case by case with a sample of 78 radio-selected BCUs, it is found that the statistical analysis and its resulting classifications agree with the results of the optical follow-up spectroscopic observations. Our observation campaign for high-|ρ{sub s}| BCUs selected with our method, i.e., |ρ{sub s}|>0.8, is ongoing.

79 ASTRONOMY AND ASTROPHYSICS↗

3D radiated power analysis of JET SPI discharges using the Emis3D forward modeling tool

Abstract Precise values for radiated energy in tokamak disruption experiments are needed to validate disruption mitigation techniques for burning plasma tokamaks like ITER and SPARC. Control room analysis of radiated power ( P rad ) on JET assumes axisymmetry, since fitting 3D radiation structures with limited bolometry coverage is an under-determined problem. In mitigated disruptions, radiation is toroidally asymmetric and 3D, due to fast-growing 3D MHD modes and localized impurity sources. To address this problem, Emis3D adopts a physics motivated forward modeling (‘guess and check’) approach, comparing experimental bolometry data to synthetic data from user-defined radiation structures. Synthetic structures are observed with the Cherab modeling framework and a best fit chosen using a reduced χ 2 statistic. 2D tomographic inversion models are tested, as well as helical flux tubes and 3D MHD simulated structures from JOREK. Two nominally identical pure neon shattered pellet injection (SPI) mitigated discharges in JET are analyzed. 2D tomographic inversions with added toroidal freedom are the best fits in the thermal quench (TQ) and current quench (CQ). In the pre-TQ, 2D reconstructions are statistically the best fits, but are likely over-optimized and do not capture the 3D radiation structure seen in fast camera images. The next-best pre-TQ fits are helical structures that extend towards the high-field side, consistent with an impurity flow under the magnetic nozzle effect also observed in JOREK simulations. Whole-disruption radiated fractions of 0.98 + 0.03 / − 0.29 and 1.01 + 0.02 / − 0.17 are found, suggesting that the stored energy may have been fully mitigated by each SPI, although mitigation efficiencies well below ITER and SPARC requirements for high energy pulses are still within the large uncertainties. Emis3D is also used to validate JOREK SPI simulations, and confirms improvements in matching experiment from changes to impurity modeling. Time-dependent toroidal peaking factors are calculated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Defect Characterization for Material Assurance in Metal Additive Manufacturing (FY15-0664)

No industry-wide standards yet exist for minimum properties in additively manufactured (AM) metals. While AM alloys such as 17-4 precipitation hardened stainless steel have been shown to have average properties that can be comparable to wrought or cast product, they suffer from inconsistent performance. Variability in the feedstock powder, feature sizes, thermal history, and laser performance can lead to unpredictable surface finish, chemistry, phase content, and defects. To address this issue, rapid, efficient, high-throughput mechanical testing and data analysis was developed, providing profound statistical insight into the stochastic variability in properties. With this new approach, 1000’s of comprehensive tensile tests can be performed for the cost of 10’s of conventional tests. This new high-throughput approach provides a material qualification pathway that is commensurate with the quick turn-around benefit of AM.

36 MATERIALS SCIENCE↗

SU-D-202-03: Statistical Segmentation On Quantitative CT for Assessing Spatial Tumor Response During Radiation Therapy Delivery

Purpose: Develop a method to segment regions of interest (ROIs) in tumor with statistically similar Hounsfield unit (HU) values and/or HU changes during chemoradiation therapy (CRT) delivery, to assess spatial tumor treatment response based on daily CTs during CRT delivery. Methods: Generate a three region map of ROIs with differential HUs, by sampling neighboring voxels around a selected voxel and comparing to the mean of the entire ROI using a t-test. The cumulative distribution function, P, is calculated from the t-test. The P value is assigned to be the value at the selected voxel, and this is repeated over all voxels in the initial ROI. Three regions are defined as: (1-P) < 0.00001 (mid region), and 0.00001 < (1-P) (mean greater than baseline and mean lower than baseline). The test is then expanded to compare daily CT sets acquired during routine CT-guided RT delivery using a CT-on-rails. The first fraction CT is used as the baseline for comparison. We tested 15 pancreatic head tumor cases undergoing CRT, to identify the ROIs and changes corresponding to normal, fibrotic, and tumor tissue. The obtained ROIs were compared with MRI-ADC maps acquired pre- and post-CRT. Results: The ROIs in 13 out of 15 patients’ first fraction CTs and pre-CRT MRIs matched the general region and slices covered, as well as in 6 out of the 9 patients with post-CRT MRIs. The high HU region designated by the t-test was seen to correlate with the tumor region in MR, and these ROIs are positioned within the same region over the course of treatment. In patients with poorly delineated tumors in MR, the t-test was inconclusive. Conclusion: The proposed statistical segmentation technique shows the potential to identify regions in tumor with differential HUs and HU changes during CRT delivery for patients with pancreas head cancer.

60 APPLIED LIFE SCIENCES↗

Antimicrobial resistance of enteric pathogens in the Military Health System, 2009 – 2019

Abstract Background Acute diarrhea (AD) can have significant impacts on military troop readiness. Medical providers must understand current trends of enteropathogen antimicrobial resistance (AMR) in service members (SMs) to inform proper, timely treatment options. However, little is known of enteric pathogen profiles across the Military Health System (MHS). The primary objectives of this study were to identify gaps in enteric pathogen surveillance within the MHS, describe the epidemiology of AMR in enteric pathogens, and identify trends across the MHS both within the Continental United States (CONUS) and outside of the Continental United States (OCONUS). Methods Health Level 7 (HL7)-formatted laboratory data were queried for all specimens where Salmonella , Shigella , and Campylobacter species, as well as Shiga toxin-producing Escherichia coli ( E. coli ) (STEC) were isolated and certified between 1 January 2009 - 31 December 2019. Antibiotic susceptibility testing (AST) results were queried and summarized where available. Descriptive statistics were calculated for each organism by specimen source, year, and susceptibility testing availability. Results Among a total of 13,852 enteric bacterial isolates, 11,877 (86%) were submitted from CONUS locations. Out of 1479 Shigella spp. and 6755 Salmonella spp. isolates, 1221 (83%) and 5019 (74%), respectively, reported any susceptibility results through the MHS. Overall, only 15% of STEC and 4% of Campylobacter spp. specimens had AST results available. Comparing AST reporting at CONUS versus OCONUS locations, AST was reported for 1175 (83%) and 46 (78%) of Shigella isolates at CONUS and OCONUS locations, respectively, and for 4591 (76%) and 428 (63%) of Salmonella isolates at CONUS and OCONUS locations, respectively. Conclusions This study revealed inconsistent enteropathogen AST conducted across the MHS, with differing trends between CONUS and OCONUS locations. Additional work is needed to assess pathogen-specific gaps in testing and reporting to develop optimal surveillance that supports the health of the force.

Ashbaugh, Hayley↗

Assessing Air Velocity Distribution in Three Sizes of Commercial Broiler Houses During Tunnel Ventilation

Abstract. Convective cooling is a critical management strategy for maintaining an environment that promotes production efficiency, thermal comfort, and animal well-being in commercial broiler houses. Variations in house size, design, and equipment configuration contribute greatly to the air velocity distribution within the facility. This study assessed total airflow, air velocity distribution, and quantified the floor area in three facilities experiencing insufficient air velocity for maintenance of production efficiency, thermal comfort, and animal well-being. Test facility 1 was an 18.3 × 170.7 m solid side-wall broiler house, test facility 2 was a 15.24 × 144.8 m solid side-wall broiler house, and test facility 3 was a 12.19 × 121.9 m curtain side-wall broiler house. Total airflow of each facility, measured with a Fan Assessment and Numeration System, was 512,730, 389,495, and 329,270 m 3 h -1 for test facilities 1, 2, and 3, respectively. Air velocity distribution patterns were characterized in each house with a Scalable Environment Assessment System (SEAS) and spatial statistics. The air velocity distributions within the test facilities were variable, with notable maxima immediately downstream of the tunnel inlets, which serve as a well-defined vena contracta, and local minima near the leading end of the evaporative pads and the exhaust fans. Equipment within the facilities had an impact on the air velocity distribution by creating reduced cross-sectional areas that resulted in localized increases in air velocity. The percentage of total bird-level floor area in each facility experiencing air velocities below 1.5 m s -1 was 14.3%, 20.7%, and 10.0% for test facilities 1, 2, and 3, respectively. The effective design velocity (V ed ) was calculated from total airflow using the measured building cross-sectional area. The V ed measured 2.97, 2.45, and 2.34 m s -1 for test facilities 1, 2, and 3, respectively. Mean cross-sectional air velocity (V cs ) was calculated from SEAS data and normalized using each facility’s V ed to account for differences in building size for comparison. Test facility 1, the largest of the three houses, generated substantially higher V cs /V ed than test facilities 2 and 3. Test facilities 2 and 3 maintained a larger proportion of V cs above V ed than test facility 1. Test facility 1 showed 26.5% of the total house length below V ed , while test facilities 2 and 3 had only 20.8% and 17.5%, respectively, of the total house length below V ed . The lower-velocity regions were due to the length of the evaporative cooling pad inlet and the use of tunnel doors, and the exhaust fan placement on the side-walls in test facility 1 created an additional pronounced low-velocity area. Placement of tunnel ventilation fans on the end-wall of the facility, rather than the side-wall, eliminated the low-velocity region at the exhaust end of the facility. Modifications to current practices for broiler production facility construction and evaporative cooling pad inlet installation would be required to minimize the low-velocity region at the inlet end of these facilities. Consideration of house width and physical arrangement of the air inlets, tunnel fans, and internal equipment are critical for improving the uniformity of air velocity in commercial broiler houses. Keywords: Air velocity, Anemometer, Broiler house, FANS, Tunnel ventilation.

Agriculture↗

Lagrangian conditional statistics and flow topology in edge plasma turbulence

Lagrangian statistics and particle transport in edge plasma turbulence are investigated using the Hasegawa–Wakatani model and its modified version. The latter shows the emergence of pronounced zonal flows. Different values of the adiabaticity parameter are considered. The main goal is to characterize the role of coherent structures, i.e., vortices and zonal flows, and their impact on the Lagrangian statistics of particles. Computationally intensive long time simulations following ensembles of test particles over hundreds of eddy turnover times are considered in statistically stationary turbulent flows. The flow topology is characterized using the Lagrangian Okubo–Weiss criterion in order to split the flow into topologically different domains. In elliptic and hyperbolic regions, the probability density functions (PDFs) of the residence time have self-similar algebraic decaying tails. However, in the intermediate regions, the PDFs exhibit exponentially decaying tails. Topologically conditioned PDFs of the Lagrangian velocity, and acceleration and density fluctuations are likewise computed. The differences between the classical Hasegawa–Wakatani system and its modified version are assessed, and the role of zonal flows is highlighted. Here, the density flux spectrum, which characterizes the contributions of different length scales, is studied, and its inertial scaling is found to be in agreement with predictions based on dimensional arguments. Analyzing the angular change of particle tracers at different time scales, corresponding to coarse grained curvature, completes the study, and these multiscale geometric statistics quantify the directional properties of the particle motion in different flow regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens [Interlaboratory round robin study on axial tensile properties of SiC/SiC tubes]

An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it was found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.

36 MATERIALS SCIENCE↗

Simple and statistically sound recommendations for analysing physical theories

Physical theories that depend on many parameters or are tested against data from many different experiments pose unique challenges to statistical inference. Many models in particle physics, astrophysics and cosmology fall into one or both of these categories. These issues are often sidestepped with statistically unsound ad hoc methods, involving intersection of parameter intervals estimated by multiple experiments, and random or grid sampling of model parameters. Whilst these methods are easy to apply, they exhibit pathologies even in low-dimensional parameter spaces, and quickly become problematic to use and interpret in higher dimensions. In this article we give clear guidance for going beyond these procedures, suggesting where possible simple methods for performing statistically sound inference, and recommendations of readily-available software tools and standards that can assist in doing so. Our aim is to provide any physicists lacking comprehensive statistical training with recommendations for reaching correct scientific conclusions, with only a modest increase in analysis burden. Furthermore, our examples can be reproduced with the code publicly available at Zenodo.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fusing geophysical signatures of locally recorded surface explosions to improve blast detection

We recorded acoustic, seismic and radio-frequency signatures of 70 solid charge (~2–12 kg) surface explosions (shots) at local distances (0.1–1.5 km) to determine if such signals could be fused for blast monitoring. We observed that each geophysical signature was sufficiently repeatable between similar shots to be identifiable with multichannel correlation detectors. Using template signals from a large explosion, we then processed heavily contaminated data recording a smaller shot with these detectors, and missed or marginally detected the resultant target signals. By then fusing the p-values of these statistics through Fisher's combined probability test, we clearly identified the same explosion signals at thresholds consistent with the false alarm on noise rates of the correlation detectors. This resulting Fisher test thereby provided high-probability detections, zero false alarms and higher theoretical detection capability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗